Benjamin Mappin-Kasirer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Benjamin Mappin-Kasirer has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Amin Madani
Department of Surgery, University of Toronto, Toronto, Canada
1 shared publication - Gerald M. Fried
Department of Surgery, McGill University, Montreal, QC, Canada
1 shared publication - Kosar Khwaja
McGill University Health Centre
1 shared publication - Liane S. Feldman
McGill University
1 shared publication - Melina C. Vassiliou
Steinberg-Bernstein Centre for Minimally Invasive Surgery and Innovation, McGill University Health Centre, 1650, Cedar Avenue, L9. 313, Montreal, QC, H3G 1A4, Canada.
1 shared publication - Paola Fata
Division of Trauma and General Surgery, McGill University Health Centre, Montreal General Hospital Site, Montreal, Canada
1 shared publication
Latest Publications
- 22 June 2016
- Published by Springer Nature in Surgical Endoscopy
- Vol. 31 (2) , 861-871
Biologic mesh for repair of ventral hernias in contaminated fields: long-term clinical and patient-reported outcomes
Background Guidelines recommend biologic prosthetics for ventral hernia repair (VHR) in contaminated fields, yet long-term and patient-reported data are limited. We aimed to determine the long-term rate of hernia recurrence, and other clinical and patient-reported outcomes following the use of porcine small intestine submucosa (PSIS) for VHR in a contaminated field. Methods Consecutive patients undergoing open VHR with PSIS mesh in a contaminated field from 2004 to 2014 were prospectively evaluated for hernia recurrence and other post-operative complications. Multivariate logistic and Cox regression analyses identified predictors of hernia recurrence and surgical site infection. Patient-reported outcomes were evaluated using SF-36, Hernia-Related Quality-of-Life Survey (HerQLes) and Body Image Questionnaire instruments. Results Forty-six hernias were repaired in clean-contaminated [16 (35 %)], contaminated [11 (24 %)] and dirty [19 (41 %)] fields. Median follow-up was 47 months [interquartile range: 31–79] and all patients had greater than 12-month follow-up. Sixteen patients (35 %) were not re-examined. Incidence of surgical site events and surgical site infection were 43 % (n = 20) and 56 % (n = 25), respectively. American Society of Anesthesiologists score 3 or greater was an independent predictor of surgical site infection (odds ratio 5.34 [95 % confidence interval 1.01–41.80], p = 0.04). Hernia recurrence occurred in 61 % (n = 28) with a median time to diagnosis of 16 months [interquartile range 8–26]. After bridged repair, 16 of 18 patients (89 %) recurred, compared to 12 of 28 (43 %) when fascia was approximated (p < 0.01). Bridged repair was an independent predictor of recurrence (odds ratio 10.67 [95 % confidence interval 2.42–76.08], p < 0.01). Patients with recurrences had significantly worse scores on the SF-36 mental health component and self-perceived body image, whereas HerQLes scores were similar. Conclusions Hernia recurrences and wound infections are high with the use of biologic PSIS mesh in contaminated surgical fields. Careful consideration is warranted using this approach.
- 22 June 2016
- Published by Springer Nature in Surgical Endoscopy
- Vol. 31 (2) , 861-871
Biologic mesh for repair of ventral hernias in contaminated fields: long-term clinical and patient-reported outcomes
Background Guidelines recommend biologic prosthetics for ventral hernia repair (VHR) in contaminated fields, yet long-term and patient-reported data are limited. We aimed to determine the long-term rate of hernia recurrence, and other clinical and patient-reported outcomes following the use of porcine small intestine submucosa (PSIS) for VHR in a contaminated field. Methods Consecutive patients undergoing open VHR with PSIS mesh in a contaminated field from 2004 to 2014 were prospectively evaluated for hernia recurrence and other post-operative complications. Multivariate logistic and Cox regression analyses identified predictors of hernia recurrence and surgical site infection. Patient-reported outcomes were evaluated using SF-36, Hernia-Related Quality-of-Life Survey (HerQLes) and Body Image Questionnaire instruments. Results Forty-six hernias were repaired in clean-contaminated [16 (35 %)], contaminated [11 (24 %)] and dirty [19 (41 %)] fields. Median follow-up was 47 months [interquartile range: 31–79] and all patients had greater than 12-month follow-up. Sixteen patients (35 %) were not re-examined. Incidence of surgical site events and surgical site infection were 43 % (n = 20) and 56 % (n = 25), respectively. American Society of Anesthesiologists score 3 or greater was an independent predictor of surgical site infection (odds ratio 5.34 [95 % confidence interval 1.01–41.80], p = 0.04). Hernia recurrence occurred in 61 % (n = 28) with a median time to diagnosis of 16 months [interquartile range 8–26]. After bridged repair, 16 of 18 patients (89 %) recurred, compared to 12 of 28 (43 %) when fascia was approximated (p < 0.01). Bridged repair was an independent predictor of recurrence (odds ratio 10.67 [95 % confidence interval 2.42–76.08], p < 0.01). Patients with recurrences had significantly worse scores on the SF-36 mental health component and self-perceived body image, whereas HerQLes scores were similar. Conclusions Hernia recurrences and wound infections are high with the use of biologic PSIS mesh in contaminated surgical fields. Careful consideration is warranted using this approach.