HTHui-Yun Tseng

Hui-Yun Tseng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hui-Yun Tseng has a total of 3 co-authors. Here are the top co-authors by number of shared publications:

  • Han-Sun Chiang

    Graduate Institute of Biomedical and Pharmaceutical Science, Fu Jen Catholic University, New Taipei City 242062, Taiwan

    2 shared publications
  • Hui-Ling Lin

    Department of Respiratory Therapy, Collage of Medicine, Chang Gung University, Taoyuan, Taiwan

    1 shared publication
  • Shih-Hsing Yang

    Department of Chest Medicine, Fu Jen Catholic University Hospital, Fu Jen Catholic University, New Taipei City, Taiwan; Department of Respiratory Therapy, Fu Jen Catholic University, New Taipei City, Taiwan

    1 shared publication

Latest Publications

  • In Vitro Evaluation of Aerosol Delivery by Hand-Held Mesh Nebulizers in an Adult Spontaneous Breathing Lung Model

    by Hui-Yun Tseng, Hui-Ling Lin, Han-Sun Chiang

    Background: Drug inhalation is common mode of treatment for chronic obstructive pulmonary disease (COPD). The aim of this study was to evaluate the efficiency of aerosol devices in a simulated COPD adult lung model using five commercially available hand-held mesh nebulizers. Materials and Methods: Five nebulizers (PARI VELOX®, Omron NE-U22, Aeroneb® Go, APEX PY001, and Pocket Air®) were tested with a unit dose of 5.0 mg/2.5 mL salbutamol. An in vitro lung model (compliance: 0.06 L/cm H2O, resistance: 20 cm H2O/L/sec) was constructed to simulate parameters (tidal volume of 500 mL, respiratory rate of 15 breaths/min, inspiratory time of 1 second) of an adult patient with COPD. A bacterial filter was attached at the bronchi level for drug collection, referring as inhaled mass. After nebulization, the inhaled mass (%), dose remaining on each component (%), particle size characteristics, and nebulizer performances were analyzed. Particle size characteristics were analyzed using an 8-stage Anderson Cascade Impactor. The salbutamol particles deposited were eluted and analyzed using a spectrophotometer at 276 nm. The inhaled mass (%), dose remaining on each component (%), particle size distribution, and nebulizer performance were statistically analyzed using analysis of variance (ANOVA) with Sheffee post hoc tests. Results: Pocket Air and APEX PY001 showed the greatest inhaled mass and the lowest dose in the mouthpiece connection. The largest and smallest mass median aerodynamic diameters were found with Omron NE-U22 and PARI VELOX, respectively. In addition, the output rate and inhaled aerosol rate (IAR) of PARI VELOX were higher than those of other nebulizers. Conclusions: This study showed that the performance of commercially available mesh nebulizers varied. Aerosol particles deposited on different auxiliary equipment directly influenced the output rate and IAR of the mesh nebulizer. Clinical validation of the drug IAR is necessary to avoid overdose and reduce drug wastage.


  • Open Access

    Impact of Oxygen Concentration Delivered via Nasal Cannula on Different Lung Conditions: A Bench Study

    by Hui-Yun Tseng, Shih-Hsing Yang, Han-Sun Chiang

    Background: Measuring the fraction of inspired oxygen (FiO2) is challenging in spontaneously breathing patients with impaired respiratory mechanics during low-flow nasal cannula. Our study investigates the FiO2 with varied tidal volume (VT) and respiratory rate (RR) among different lung mechanics and provides equations to estimate the FiO2. Methods: Two training and test lungs were used in this study, and the three lung mechanics (normal (R5/C60), restrictive (R20/C80), obstructive (R5/C40)) were designed. Spontaneous breathing with VT (300, 500, and 700 mL) and RR (10, 20, and 30 breaths/min) was simulated. The flow rate of the nasal cannula was set to 1, 3, and 5 L per minute (LPM), and the FiO2 was measured at the carina. Results: The lowest and highest FiO2 were evident during high (700 mL) and low VT (300 mL), respectively, among normal, restrictive, and obstructive lung models. As RR increases, this decreases the FiO2. However, we found that VT and oxygen flow rate are the principal factors influencing measured FiO2 by multiple linear regression analysis. Conclusions: Our data suggest that the actual FiO2 is never as high in spontaneously breathing patients as that estimated. VT and oxygen flow rate had a substantial impact on the FiO2.