Thaísa Pinheiro Silva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Thaísa Pinheiro Silva has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Matheus Lima Oliveira
Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Brazil
7 shared publications - Deborah Queiroz Freitas
Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, Brazil
6 shared publications Christiano Oliveira-Santos
Department of Diagnosis and Oral Health, University of Louisville School of Dentistry, Louisville, KY, USA
5 shared publicationsDeborah Queiroz Freitas
Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil
5 shared publications- Maria Fernanda Silva Andrade-Bortoletto
Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, Brazil
5 shared publications - Caio Alencar-Palha
University of Campinas Department of Oral Diagnosis, Piracicaba Dental School Piracicaba, SP, Brazil – Limeira Avenue, 901, Piracicaba, São Paulo, Brazil, 13414-903
4 shared publications
Latest Publications
- 30 October 2026
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
Diagnostic accuracy of 3 cone-beam CT protocols and metal artifact reduction tool for detecting the second canal of mandibular incisors adjacent to a zirconia implant
Objective: To compare the diagnostic accuracy of 3 cone beam computed tomography (CBCT) acquisition protocols, 1 low-resolution (LR) and 2 high-resolution (HR) protocols, using a metal artifact reduction tool (MAR) for detecting a second canal in mandibular incisors adjacent to a zirconia implant. Material and methods: Twenty single-rooted mandibular incisors were included, 12 with 1 canal and 8 with 2 canals confirmed by micro-CT. The roots and a zirconia implant were placed into the alveolar sockets of the right and left mandibular central incisors of a dry human mandible, respectively. In total, 240 CBCT scans were obtained using FOV 5 × 5 cm, 90 kVp, with and without an implant, for each root. The variable parameters included the MAR tool, 1 LR-protocol (0.2 mm voxel, 5 mA), and 2 HR-protocols (0.085 mm voxel, 4 and 10 mA). Five calibrated examiners independently evaluated the scans. An ordinal cumulative link mixed model (CLMM) with crossed random intercepts for roots and examiners was used for data analysis (α = 5%). Results: The CLMM revealed a significant main effect for implant presence (P = .049) and canal status (P < .001), but not for protocol (P = .135) or MAR (P = .392). Significant protocol x canal status (P < .001) and implant x canal status (P < .001) interactions were found, whereas MAR interactions were not significant (P > .05). In 2-canal roots, the zirconia implant significantly induced false-negative shifts under HR-4 (P < .0001) and LR (P < .0001) protocols, whereas HR-10 preserved sensitivity (P = .7760). In single-canal roots, implants induced false-positive shifts in HR-10 (P = .0011) and HR-4 (P = .0011). Conclusion: Zirconia implants impair second canal detection via false-negative and false-positive errors. High-resolution CBCT (HR-10) should be prioritized to preserve diagnostic sensitivity, whereas MAR offers no clinical benefit and cannot compensate for reduced resolution or exposure. Advances in knowledge: CBCT diagnostic performance near zirconia implants relies on acquisition protocol rather than MAR activation. High-resolution CBCT (HR-10) mitigates implant-induced false negatives, whereas lower-resolution or lower-milliamperage protocols compromise diagnostic accuracy.
- 30 October 2026
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
Diagnostic accuracy of 3 cone-beam CT protocols and metal artifact reduction tool for detecting the second canal of mandibular incisors adjacent to a zirconia implant
Objective: To compare the diagnostic accuracy of 3 cone beam computed tomography (CBCT) acquisition protocols, 1 low-resolution (LR) and 2 high-resolution (HR) protocols, using a metal artifact reduction tool (MAR) for detecting a second canal in mandibular incisors adjacent to a zirconia implant. Material and methods: Twenty single-rooted mandibular incisors were included, 12 with 1 canal and 8 with 2 canals confirmed by micro-CT. The roots and a zirconia implant were placed into the alveolar sockets of the right and left mandibular central incisors of a dry human mandible, respectively. In total, 240 CBCT scans were obtained using FOV 5 × 5 cm, 90 kVp, with and without an implant, for each root. The variable parameters included the MAR tool, 1 LR-protocol (0.2 mm voxel, 5 mA), and 2 HR-protocols (0.085 mm voxel, 4 and 10 mA). Five calibrated examiners independently evaluated the scans. An ordinal cumulative link mixed model (CLMM) with crossed random intercepts for roots and examiners was used for data analysis (α = 5%). Results: The CLMM revealed a significant main effect for implant presence (P = .049) and canal status (P < .001), but not for protocol (P = .135) or MAR (P = .392). Significant protocol x canal status (P < .001) and implant x canal status (P < .001) interactions were found, whereas MAR interactions were not significant (P > .05). In 2-canal roots, the zirconia implant significantly induced false-negative shifts under HR-4 (P < .0001) and LR (P < .0001) protocols, whereas HR-10 preserved sensitivity (P = .7760). In single-canal roots, implants induced false-positive shifts in HR-10 (P = .0011) and HR-4 (P = .0011). Conclusion: Zirconia implants impair second canal detection via false-negative and false-positive errors. High-resolution CBCT (HR-10) should be prioritized to preserve diagnostic sensitivity, whereas MAR offers no clinical benefit and cannot compensate for reduced resolution or exposure. Advances in knowledge: CBCT diagnostic performance near zirconia implants relies on acquisition protocol rather than MAR activation. High-resolution CBCT (HR-10) mitigates implant-induced false negatives, whereas lower-resolution or lower-milliamperage protocols compromise diagnostic accuracy.
- Open Access
- 26 September 2026
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 30 (10) , 476
Can vision-language models estimate patient age? evidence from panoramic radiographs
Objective: To explore the performance and limitations of three vision-language models (VLMs) in estimating chronological age from panoramic radiographs. Materials and Methods: A sample of 140 panoramic radiographs from individuals aged 7 to 20 years was uploaded to three VLMs: ChatGPT-4o, Microsoft Copilot Fast, and Microsoft Copilot Deep. Each VLM was independently prompted to estimate chronological age based on dental eruption patterns. The results were compared with the individuals’ chronological ages. Statistical analysis included agreement within ± 1 year percentage calculation, and one-way analysis of variance to compare estimated and chronological ages (α = 0.05). Results: All three VLMs demonstrated low agreement in age estimation, with overall performance below 35%. Slightly better agreement was observed in individuals aged 9–10 years. The models showed greater deviations from chronological age at the extremes of the age range (7–8 and 17–20 years). No correct estimations were recorded for individuals aged 7, 17, 18, 19, and 20 years for ChatGPT-4o, 15 and 20 years for Microsoft Copilot Fast, and 20 years for Microsoft Copilot Deep. Conclusions: The evaluated VLMs showed limited agreement in estimating chronological age from panoramic radiographs. Therefore, their application in clinical and forensic contexts cannot currently be recommended. Clinical Relevance: Understanding the potential applications and limitations of VLMs as an auxiliary tool in image interpretation is imperative to its use in clinical scenarios.
- 26 September 2026
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 30 (10) , 476
Open AccessCan vision-language models estimate patient age? evidence from panoramic radiographs
Objective: To explore the performance and limitations of three vision-language models (VLMs) in estimating chronological age from panoramic radiographs. Materials and Methods: A sample of 140 panoramic radiographs from individuals aged 7 to 20 years was uploaded to three VLMs: ChatGPT-4o, Microsoft Copilot Fast, and Microsoft Copilot Deep. Each VLM was independently prompted to estimate chronological age based on dental eruption patterns. The results were compared with the individuals’ chronological ages. Statistical analysis included agreement within ± 1 year percentage calculation, and one-way analysis of variance to compare estimated and chronological ages (α = 0.05). Results: All three VLMs demonstrated low agreement in age estimation, with overall performance below 35%. Slightly better agreement was observed in individuals aged 9–10 years. The models showed greater deviations from chronological age at the extremes of the age range (7–8 and 17–20 years). No correct estimations were recorded for individuals aged 7, 17, 18, 19, and 20 years for ChatGPT-4o, 15 and 20 years for Microsoft Copilot Fast, and 20 years for Microsoft Copilot Deep. Conclusions: The evaluated VLMs showed limited agreement in estimating chronological age from panoramic radiographs. Therefore, their application in clinical and forensic contexts cannot currently be recommended. Clinical Relevance: Understanding the potential applications and limitations of VLMs as an auxiliary tool in image interpretation is imperative to its use in clinical scenarios.
- 18 February 2026
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 55 (5) , 439-449
Detection of misfits at the abutment-crown interface: comparison between stationary intraoral tomosynthesis and periapical radiography acquired with different vertical angulations
Objectives: To compare the diagnostic accuracy of stationary intraoral tomosynthesis (s-IOT) with periapical radiography (PA) for misfit detection at the abutment-crown interface, across different misfit magnitudes and vertical angulations. Methods: Twenty prototype sets of maxillae and mandibles with implants placed in the maxillary central incisor region were used, and ceramic copings were fabricated. Misfits of 50, 100, and 150 μm were simulated by interposing 50-μm-thick polyester strips at the abutment-crown interface. The group without +simulated misfit had no strips. PA and s-IOT images were acquired using 3 different vertical X-ray tube angulations: perpendicular to the implant (0°), positioned inferiorly (−10°), and superiorly (+10°). Five oral radiologists evaluated 480 images using a 5-point scale. The area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were analysed using repeated measures ANOVA and Tukey’s post-hoc test (α = 5%). Results: No significant differences were observed between PA and s-IOT (P > .05). AUC at 50 µm was significantly lower than 100 µm for all vertical angulations, and than 150 µm for −10° and +10° (P < .05); 100 µm was also lower than 150 µm for +10° (P < .05). +10° showed lower AUC than 0° and −10° at 50 µm, than 0° at 100 µm, and than −10° at 150 µm (P < .05). Sensitivity increased with misfit magnitude; 100 µm and 150 µm were higher than 50 µm for −10° and +10° (P < .05). +10° showed lower sensitivity than 0° at 50 µm and −10° at 150 µm (P < .05). Specificity varied only by vertical angulation; 0° showed the lowest values (P < .05). Conclusion: PA and s-IOT demonstrated comparable performance, +10° exhibited the lowest accuracy, and larger misfits were more easily detected. Advances in knowledge: s-IOT provides additional bucco-lingual information; however, PA demonstrated comparable diagnostic accuracy in detecting misfits at the abutment-crown interface while exposing patients to lower radiation doses. Additionally, when ideal parallelism cannot be achieved, directing the X-ray beam towards the implant apex, rather than the prosthetic crown, may optimize misfit detection.
- 18 February 2026
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 55 (5) , 439-449
Detection of misfits at the abutment-crown interface: comparison between stationary intraoral tomosynthesis and periapical radiography acquired with different vertical angulations
Objectives: To compare the diagnostic accuracy of stationary intraoral tomosynthesis (s-IOT) with periapical radiography (PA) for misfit detection at the abutment-crown interface, across different misfit magnitudes and vertical angulations. Methods: Twenty prototype sets of maxillae and mandibles with implants placed in the maxillary central incisor region were used, and ceramic copings were fabricated. Misfits of 50, 100, and 150 μm were simulated by interposing 50-μm-thick polyester strips at the abutment-crown interface. The group without +simulated misfit had no strips. PA and s-IOT images were acquired using 3 different vertical X-ray tube angulations: perpendicular to the implant (0°), positioned inferiorly (−10°), and superiorly (+10°). Five oral radiologists evaluated 480 images using a 5-point scale. The area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were analysed using repeated measures ANOVA and Tukey’s post-hoc test (α = 5%). Results: No significant differences were observed between PA and s-IOT (P > .05). AUC at 50 µm was significantly lower than 100 µm for all vertical angulations, and than 150 µm for −10° and +10° (P < .05); 100 µm was also lower than 150 µm for +10° (P < .05). +10° showed lower AUC than 0° and −10° at 50 µm, than 0° at 100 µm, and than −10° at 150 µm (P < .05). Sensitivity increased with misfit magnitude; 100 µm and 150 µm were higher than 50 µm for −10° and +10° (P < .05). +10° showed lower sensitivity than 0° at 50 µm and −10° at 150 µm (P < .05). Specificity varied only by vertical angulation; 0° showed the lowest values (P < .05). Conclusion: PA and s-IOT demonstrated comparable performance, +10° exhibited the lowest accuracy, and larger misfits were more easily detected. Advances in knowledge: s-IOT provides additional bucco-lingual information; however, PA demonstrated comparable diagnostic accuracy in detecting misfits at the abutment-crown interface while exposing patients to lower radiation doses. Additionally, when ideal parallelism cannot be achieved, directing the X-ray beam towards the implant apex, rather than the prosthetic crown, may optimize misfit detection.
- 10 February 2026
- Published by Elsevier in Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
- Vol. 142 (1) , 130-139
Image distortion in stationary intraoral tomosynthesis from different high-density materials
- 10 February 2026
- Published by Elsevier in Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
- Vol. 142 (1) , 130-139
Image distortion in stationary intraoral tomosynthesis from different high-density materials
- 21 January 2026
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 39 (5) , 4686-4694
Evaluation of ChatGPT–4 and Microsoft Copilot for Third-Molar Assessment on Panoramic Radiographs
To assess the performance of two AI chatbot assistants in identifying the presence and classifying the position of third molars on panoramic radiographs. A total of 114 third molars from 100 panoramic radiographs were evaluated consensually by three examiners and independently by two AI chatbot assistants (ChatGPT–4 and Microsoft Copilot). They were asked to provide descriptions regarding the orientation of the third molar’s long axis, level of bone inclusion, space between the lower second molar and the mandibular ramus, and proximity of the third molar to the mandibular canal or maxillary sinus. Keywords generated by the AI chatbot assistants were compared to those used by the examiners and scored as 0 (incorrect), 0.5 (partially correct), or 1 (correct). Mean scores and standard deviations were calculated for each parameter and compared using the Wilcoxon test (α = 0.05). Mean scores across the four parameters ranged from 0.08 to 0.30 (SD = 0.42–0.44) for ChatGPT–4 and from 0.25 to 0.31 (SD = 0.42–0.47) for Microsoft Copilot. The only significant difference in performance between the AI chatbots was observed in the space between the lower second molar and ramus, in favor of Microsoft Copilot (p < 0.05). Overall performance scores were 0.22 (SD = 0.42) for ChatGPT–4 and 0.28 (SD = 0.46) for Microsoft Copilot. Furthermore, hallucinations such as classifying absent teeth were also observed. Both ChatGPT–4 and Microsoft Copilot demonstrate generally low performance in accurately identifying and classifying the position of third molars on panoramic radiographs.
- 21 January 2026
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 39 (5) , 4686-4694
Evaluation of ChatGPT–4 and Microsoft Copilot for Third-Molar Assessment on Panoramic Radiographs
To assess the performance of two AI chatbot assistants in identifying the presence and classifying the position of third molars on panoramic radiographs. A total of 114 third molars from 100 panoramic radiographs were evaluated consensually by three examiners and independently by two AI chatbot assistants (ChatGPT–4 and Microsoft Copilot). They were asked to provide descriptions regarding the orientation of the third molar’s long axis, level of bone inclusion, space between the lower second molar and the mandibular ramus, and proximity of the third molar to the mandibular canal or maxillary sinus. Keywords generated by the AI chatbot assistants were compared to those used by the examiners and scored as 0 (incorrect), 0.5 (partially correct), or 1 (correct). Mean scores and standard deviations were calculated for each parameter and compared using the Wilcoxon test (α = 0.05). Mean scores across the four parameters ranged from 0.08 to 0.30 (SD = 0.42–0.44) for ChatGPT–4 and from 0.25 to 0.31 (SD = 0.42–0.47) for Microsoft Copilot. The only significant difference in performance between the AI chatbots was observed in the space between the lower second molar and ramus, in favor of Microsoft Copilot (p < 0.05). Overall performance scores were 0.22 (SD = 0.42) for ChatGPT–4 and 0.28 (SD = 0.46) for Microsoft Copilot. Furthermore, hallucinations such as classifying absent teeth were also observed. Both ChatGPT–4 and Microsoft Copilot demonstrate generally low performance in accurately identifying and classifying the position of third molars on panoramic radiographs.
- Open Access
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 40
Humanization of AI-generated abstracts in oral radiology: Role of chatbots and dedicated platforms
The rise of generative artificial intelligence (AI) in scientific writing has prompted the development of platforms designed to "humanize" AI-generated text by rephrasing content to reduce its detectability as machine-generated. This study aimed to evaluate the performance of chatbots and dedicated platforms in humanizing AI-generated abstracts. Thirty high-impact scientific articles published in dentomaxillofacial radiology journals were selected. The Methodology and Results sections of each abstract were used to prompt two chatbots—ChatGPT and Gemini—to generate complete abstracts. These AI-generated abstracts were then humanized using the same chatbots along with two dedicated platforms: HumanizeAI and StealthWriter. The percentage of AI-generated content was determined for all abstracts (n = 330), including the original human-written abstracts, using GPTZero. AI detection rates were compared using two-way analysis of variance followed by Tukey's post hoc test (α = 0.05). The results showed that original abstracts and AI-generated abstracts humanized by HumanizeAI and StealthWriter exhibited significantly lower GPTZero detection rates (p < 0.05), whereas abstracts generated or humanized by chatbots showed significantly higher detection rates (p < 0.05). In conclusion, chatbot-generated scientific abstracts humanized by dedicated platforms exhibit low AI detection rates, whereas those humanized by chatbots exhibit considerably higher detection levels. Educators must prepare students with critical appraisal skills to identify AI-generated content and uphold academic integrity, ensuring that AI serves as a complementary tool rather than a means of misrepresentation.
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 40
Open AccessHumanization of AI-generated abstracts in oral radiology: Role of chatbots and dedicated platforms
The rise of generative artificial intelligence (AI) in scientific writing has prompted the development of platforms designed to "humanize" AI-generated text by rephrasing content to reduce its detectability as machine-generated. This study aimed to evaluate the performance of chatbots and dedicated platforms in humanizing AI-generated abstracts. Thirty high-impact scientific articles published in dentomaxillofacial radiology journals were selected. The Methodology and Results sections of each abstract were used to prompt two chatbots—ChatGPT and Gemini—to generate complete abstracts. These AI-generated abstracts were then humanized using the same chatbots along with two dedicated platforms: HumanizeAI and StealthWriter. The percentage of AI-generated content was determined for all abstracts (n = 330), including the original human-written abstracts, using GPTZero. AI detection rates were compared using two-way analysis of variance followed by Tukey's post hoc test (α = 0.05). The results showed that original abstracts and AI-generated abstracts humanized by HumanizeAI and StealthWriter exhibited significantly lower GPTZero detection rates (p < 0.05), whereas abstracts generated or humanized by chatbots showed significantly higher detection rates (p < 0.05). In conclusion, chatbot-generated scientific abstracts humanized by dedicated platforms exhibit low AI detection rates, whereas those humanized by chatbots exhibit considerably higher detection levels. Educators must prepare students with critical appraisal skills to identify AI-generated content and uphold academic integrity, ensuring that AI serves as a complementary tool rather than a means of misrepresentation.
- Open Access
- 1 January 2026
- Published by XMLink in Imaging Science in Dentistry
- Vol. 56 (3) , 291
Comparison between dual-angle periapical technique and cone-beam computed tomography in the identification of a second canal in mandibular incisors in the presence of a zirconia implant: An in vitro study
Andrade-Bortoletto MF, et al. Imaging Sci Dent. 2026 ;56:e29. https://doi.org/10.5624/isd.20260111
- 1 January 2026
- Published by XMLink in Imaging Science in Dentistry
- Vol. 56 (3) , 291
Open AccessComparison between dual-angle periapical technique and cone-beam computed tomography in the identification of a second canal in mandibular incisors in the presence of a zirconia implant: An in vitro study
Andrade-Bortoletto MF, et al. Imaging Sci Dent. 2026 ;56:e29. https://doi.org/10.5624/isd.20260111
- 25 November 2025
- Published by Elsevier in Journal of Forensic and Legal Medicine
- Vol. 117, 103045
Age estimation based on Demirjian's method using third molars in individuals from Southeastern Brazil
- 25 November 2025
- Published by Elsevier in Journal of Forensic and Legal Medicine
- Vol. 117, 103045
Age estimation based on Demirjian's method using third molars in individuals from Southeastern Brazil
- Open Access
- 10 October 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-9
Populational influence on cephalometric landmark identification: performance of two AI-driven software programs in Brazilian and Korean images
Objective: To assess the performance of cephalometric landmark identification performed by two AI-driven software programs in images from different populations (Brazilian and Korean). Methods: Sixty lateral cephalometric radiographs (30 Brazilian and 30 Korean) were analyzed. The Brazilian images were acquired using the Orthophos XG 5/Ceph device, while the Korean images were obtained from the International Symposium on Biomedical Imaging 2015 database. Images of patients with permanent dentition were included, excluding those with poor head positioning or severe craniofacial deformities. Twenty cephalometric landmarks were identified by two examiners used as the reference standard. Two AI-driven software programs, CefBot™ (Brazil) and WebCeph™ (Korea), automatically identified the same landmarks. Coordinate values for each landmark were measured using ImageJ, and the data were analyzed with Analysis of Variance and Dunnett’s post-hoc test. Results: The Brazilian software showed high accuracy in identifying landmarks on Brazilian images (90%) but was less precise on Korean images (80%), with significant discrepancies in the Glabella, Menton L, Basion, and Orbitale landmarks. Similarly, the Korean software had a higher accuracy in its own population (95%) than in another population (85%), with notable inaccuracies in the Menton L, Basion, and Porion landmarks. Conclusion: Discrepancies in the identification of specific landmarks, such as Glabella and Menton L, suggest that the accuracy of the software may be influenced by the training process itself and by the population origin of the training data.
- 10 October 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-9
Open AccessPopulational influence on cephalometric landmark identification: performance of two AI-driven software programs in Brazilian and Korean images
Objective: To assess the performance of cephalometric landmark identification performed by two AI-driven software programs in images from different populations (Brazilian and Korean). Methods: Sixty lateral cephalometric radiographs (30 Brazilian and 30 Korean) were analyzed. The Brazilian images were acquired using the Orthophos XG 5/Ceph device, while the Korean images were obtained from the International Symposium on Biomedical Imaging 2015 database. Images of patients with permanent dentition were included, excluding those with poor head positioning or severe craniofacial deformities. Twenty cephalometric landmarks were identified by two examiners used as the reference standard. Two AI-driven software programs, CefBot™ (Brazil) and WebCeph™ (Korea), automatically identified the same landmarks. Coordinate values for each landmark were measured using ImageJ, and the data were analyzed with Analysis of Variance and Dunnett’s post-hoc test. Results: The Brazilian software showed high accuracy in identifying landmarks on Brazilian images (90%) but was less precise on Korean images (80%), with significant discrepancies in the Glabella, Menton L, Basion, and Orbitale landmarks. Similarly, the Korean software had a higher accuracy in its own population (95%) than in another population (85%), with notable inaccuracies in the Menton L, Basion, and Porion landmarks. Conclusion: Discrepancies in the identification of specific landmarks, such as Glabella and Menton L, suggest that the accuracy of the software may be influenced by the training process itself and by the population origin of the training data.
- 24 June 2025
- Published by Springer Nature in Oral Radiology
- Vol. 42 (1) , 51-59
Comparison of image quality between intraoral radiographic images using wall-mounted and handheld dental X-ray units
To compare the quality of intraoral radiographic images of two types of dental detectors using wall-mounted and handheld dental X-ray units. Six intraoral dental radiographic images of a Dental Digital Quality Assurance radiographic phantom (Dental Imaging Consultants LLC, San Antonio, TX) were acquired with two types of dental receptors: photostimulable phosphor (PSP) receptor (CS 7600 digital system, Carestream Dental, Rochester, New York, United States) under two conditions, filtered and unfiltered; and a complementary metal oxide semiconductor (CMOS) sensor (RGV 6200, Carestream Dental, Rochester, New York, United States) using handheld (Nomad Pro 2; Kavo Kerr, Biberach, Germany) and wall-mounted (Midmark Preva DC Intraoral X-ray, Midmark Corporation, Illinois, United States) dental X-ray units. Spatial and contrast resolutions and percentage of radiographic contrast were evaluated. Then, radiographic images of an acrylic block were obtained under the same conditions and brightness, noise, and uniformity were assessed. Values were compared between the devices and the digital systems with Analysis of Variance (P < 0.05). There were no differences in spatial and contrast resolutions between dental X-ray units and detectors. Handheld dental X-ray units provide significantly higher radiographic contrast (P < 0.001) and lower brightness, noise, and uniformity (P < 0.001) regardless of the digital system used. Compared to a wall-mounted dental X-ray unit, the handheld device provides higher radiographic contrast and lower brightness, noise, and uniformity regardless of the digital system used.
- 24 June 2025
- Published by Springer Nature in Oral Radiology
- Vol. 42 (1) , 51-59
Comparison of image quality between intraoral radiographic images using wall-mounted and handheld dental X-ray units
To compare the quality of intraoral radiographic images of two types of dental detectors using wall-mounted and handheld dental X-ray units. Six intraoral dental radiographic images of a Dental Digital Quality Assurance radiographic phantom (Dental Imaging Consultants LLC, San Antonio, TX) were acquired with two types of dental receptors: photostimulable phosphor (PSP) receptor (CS 7600 digital system, Carestream Dental, Rochester, New York, United States) under two conditions, filtered and unfiltered; and a complementary metal oxide semiconductor (CMOS) sensor (RGV 6200, Carestream Dental, Rochester, New York, United States) using handheld (Nomad Pro 2; Kavo Kerr, Biberach, Germany) and wall-mounted (Midmark Preva DC Intraoral X-ray, Midmark Corporation, Illinois, United States) dental X-ray units. Spatial and contrast resolutions and percentage of radiographic contrast were evaluated. Then, radiographic images of an acrylic block were obtained under the same conditions and brightness, noise, and uniformity were assessed. Values were compared between the devices and the digital systems with Analysis of Variance (P < 0.05). There were no differences in spatial and contrast resolutions between dental X-ray units and detectors. Handheld dental X-ray units provide significantly higher radiographic contrast (P < 0.001) and lower brightness, noise, and uniformity (P < 0.001) regardless of the digital system used. Compared to a wall-mounted dental X-ray unit, the handheld device provides higher radiographic contrast and lower brightness, noise, and uniformity regardless of the digital system used.