  • Diagnostic accuracy of 3 cone-beam CT protocols and metal artifact reduction tool for detecting the second canal of mandibular incisors adjacent to a zirconia implant

    by Maria Fernanda Silva Andrade-Bortoletto, Thaísa Pinheiro Silva, Marcela Tarosso Réa, Renata Maira de Souza Leal, Débora Costa Ruiz, Deborah Queiroz Freitas

    Objective: To compare the diagnostic accuracy of 3 cone beam computed tomography (CBCT) acquisition protocols, 1 low-resolution (LR) and 2 high-resolution (HR) protocols, using a metal artifact reduction tool (MAR) for detecting a second canal in mandibular incisors adjacent to a zirconia implant. Material and methods: Twenty single-rooted mandibular incisors were included, 12 with 1 canal and 8 with 2 canals confirmed by micro-CT. The roots and a zirconia implant were placed into the alveolar sockets of the right and left mandibular central incisors of a dry human mandible, respectively. In total, 240 CBCT scans were obtained using FOV 5 × 5 cm, 90 kVp, with and without an implant, for each root. The variable parameters included the MAR tool, 1 LR-protocol (0.2 mm voxel, 5 mA), and 2 HR-protocols (0.085 mm voxel, 4 and 10 mA). Five calibrated examiners independently evaluated the scans. An ordinal cumulative link mixed model (CLMM) with crossed random intercepts for roots and examiners was used for data analysis (α = 5%). Results: The CLMM revealed a significant main effect for implant presence (P = .049) and canal status (P < .001), but not for protocol (P = .135) or MAR (P = .392). Significant protocol x canal status (P < .001) and implant x canal status (P < .001) interactions were found, whereas MAR interactions were not significant (P > .05). In 2-canal roots, the zirconia implant significantly induced false-negative shifts under HR-4 (P < .0001) and LR (P < .0001) protocols, whereas HR-10 preserved sensitivity (P = .7760). In single-canal roots, implants induced false-positive shifts in HR-10 (P = .0011) and HR-4 (P = .0011). Conclusion: Zirconia implants impair second canal detection via false-negative and false-positive errors. High-resolution CBCT (HR-10) should be prioritized to preserve diagnostic sensitivity, whereas MAR offers no clinical benefit and cannot compensate for reduced resolution or exposure. Advances in knowledge: CBCT diagnostic performance near zirconia implants relies on acquisition protocol rather than MAR activation. High-resolution CBCT (HR-10) mitigates implant-induced false negatives, whereas lower-resolution or lower-milliamperage protocols compromise diagnostic accuracy.

  • Open Access

    Effect of implant presence, tube current, and metal artifact reduction tool on internal root resorption detection using cone beam computed tomography

    by Débora Costa Ruiz, Maria Fernanda Silva Andrade-Bortoletto, Sergio Lins De-Azevedo-Vaz, Deborah Queiroz Freitas

  • Open Access

    Can vision-language models estimate patient age? evidence from panoramic radiographs

    by Thaísa Pinheiro Silva, Fernanda Bulhões Fagundes, Maria Fernanda Andrade-Bortoletto, Christiano Oliveira-Santos, Deborah Queiroz Freitas, Matheus L. Oliveira

    Objective: To explore the performance and limitations of three vision-language models (VLMs) in estimating chronological age from panoramic radiographs. Materials and Methods: A sample of 140 panoramic radiographs from individuals aged 7 to 20 years was uploaded to three VLMs: ChatGPT-4o, Microsoft Copilot Fast, and Microsoft Copilot Deep. Each VLM was independently prompted to estimate chronological age based on dental eruption patterns. The results were compared with the individuals’ chronological ages. Statistical analysis included agreement within ± 1 year percentage calculation, and one-way analysis of variance to compare estimated and chronological ages (α = 0.05). Results: All three VLMs demonstrated low agreement in age estimation, with overall performance below 35%. Slightly better agreement was observed in individuals aged 9–10 years. The models showed greater deviations from chronological age at the extremes of the age range (7–8 and 17–20 years). No correct estimations were recorded for individuals aged 7, 17, 18, 19, and 20 years for ChatGPT-4o, 15 and 20 years for Microsoft Copilot Fast, and 20 years for Microsoft Copilot Deep. Conclusions: The evaluated VLMs showed limited agreement in estimating chronological age from panoramic radiographs. Therefore, their application in clinical and forensic contexts cannot currently be recommended. Clinical Relevance: Understanding the potential applications and limitations of VLMs as an auxiliary tool in image interpretation is imperative to its use in clinical scenarios.

  • Open Access

    Photon‐Counting CT for Diagnosing Vertical Root Fractures in Teeth With Metal Posts: An Ex Vivo Comparative Analysis With Four CBCT Devices

    by Renata M. S. Leal, Fernanda B. Fagundes, Maria F. S. A. Bortoletto, Samuel C. Kluthcovsky, Walter Coudyzer, Bruno C. Cavenago, Reinhilde Jacobs, Rocharles Cavalcante Fontenele

    Objective: Photon‐counting computed tomography (PCCT) represents a major innovation in X‐ray detection technology, offering improved signal efficiency and reduced electronic noise compared with cone‐beam computed tomography (CBCT), which can enhance image quality. This study aimed to evaluate the diagnostic performance of PCCT in detecting vertical root fractures (VRF), in comparison with four CBCT devices. Methodology: Eighteen single‐rooted teeth were endodontically treated, and VRF was induced in eight of them. Each tooth was individually placed into the mandibular first premolar empty socket of an anthropomorphic phantom and scanned under three conditions: without a metal post, with a nickel‐chromium metal post (Ni‐Cr), and with a cobalt‐chromium metal post (Co‐Cr) in five CT devices: the NAEOTOM Alpha PCCT (Siemens Healthineers) device and four CBCT devices (3D Accuitomo 170—Morita, Veraview X800—Morita, NewTom VGi evo—NewTom, and Carestream 9600—Carestream). The highest‐resolution protocol available on each device was used, resulting in a total of 270 scans. Five experienced dentomaxillofacial radiologists independently and blindly evaluated the scans using a five‐point confidence scale. Diagnostic accuracy was assessed by calculating the area under the ROC curve (AUC), sensitivity, and specificity, with results compared by two‐way ANOVA with post hoc Tukey's test ( α = 0.05). Results: NewTom VGi and PCCT devices showed significantly higher AUC values than the Veraview X800, regardless of the metal post material ( p < 0.05). CS9600 and PCCT devices exhibited significantly higher sensitivity values in diagnosing with Ni‐Cr posts than the Accuitomo 3D and Veraview X800 devices ( p < 0.05). With the Co‐Cr metal post, the NewTom VGi, CS9600, and PCCT devices showed significantly higher sensitivity values compared to the Veraview X800 device ( p < 0.05). There were no statistically significant differences in specificity, regardless of the CT device or metal post material ( p > 0.05). Conclusions: The NEAOTOM Alpha PCCT showed high diagnostic accuracy for VRF detection in an ex vivo model, comparable to high‐resolution CBCT devices, highlighting its diagnostic performance under controlled ex vivo conditions.


  • Open Access

    Dental implants near internally resorpted roots: comparison between CBCT exam and periapical radiography

    by Débora Costa Ruiz, Maria Fernanda Silva Andrade-Bortoletto, Sergio Lins De-Azevedo-Vaz, Deborah Queiroz Freitas

    This study compared the diagnostic accuracy of cone-beam computed tomography (CBCT) and periapical radiography for detecting internal root resorption (IRR) in teeth adjacent to titanium or zirconia implants. Twenty single-rooted teeth (10 with IRR and 10 without) were individually placed in a human mandible. Periapical radiographs and CBCT exams were obtained with and without a titanium or zirconia implant. Radiographs were acquired with a photostimulable phosphor plate receptor at 70 kVp, 7 mA, and 0.160 s. CBCT scans were acquired at 90 kVp, 8 mA, 0.085mm3 voxel size, and 5×5cm field of view. Four examiners independently evaluated the radiographs and the CBCT exams. The area under the receiver operating characteristic curve (AUC), sensitivity, and specificity values were calculated and compared using two-way ANOVA (α = 5%). Inter- and intraexaminer agreement for IRR diagnosis was assessed using weighted Kappa. CBCT demonstrated significantly higher AUC (p=0.007), sensitivity (p=0.009), and specificity (p=0.037) for IRR detection compared with periapical radiographs, regardless of implant presence or type. The presence of an implant did not influence the results. Intraexaminer agreement ranged from moderate to almost perfect (0.48-0.95), and interexaminer agreement ranged from fair to almost perfect (0.30-0.85). CBCT demonstrated higher diagnostic accuracy than periapical radiography for detecting IRR, even in the presence of adjacent titanium or zirconia implants, as implant-related artifacts did not impair image interpretation. Therefore, when periapical radiography is insufficient to establish a diagnosis, the use of CBCT may be clinically justified despite the additional radiation exposure.

  • Open Access

    Effect of 45° head angulation and a metal artifact reduction algorithm on cone-beam computed tomography image quality around titanium and zirconia implants

    by Maria Fernanda Silva Andrade-Bortoletto, Marcela Tarosso Réa, Débora Costa Ruiz, Deborah Queiroz Freitas

    Andrade-Bortoletto MF, et al. Imaging Sci Dent. 2026 ;56:e35. https://doi.org/10.5624/isd.20260199

  • Open Access

    Comparison between dual-angle periapical technique and cone-beam computed tomography in the identification of a second canal in mandibular incisors in the presence of a zirconia implant: An in vitro study

    by Maria Fernanda Silva Andrade-Bortoletto, Fernanda Rodrigues de Oliveira, Thaísa Pinheiro Silva, Marcela Tarosso Réa, Renata Maira de Souza Leal, Débora Costa Ruiz, Deborah Queiroz Freitas

    Andrade-Bortoletto MF, et al. Imaging Sci Dent. 2026 ;56:e29. https://doi.org/10.5624/isd.20260111

  • Age estimation based on Demirjian's method using third molars in individuals from Southeastern Brazil

    by Amanda Farias-Gomes, Maria Luíza dos Anjos Pontual, Thaísa Pinheiro Silva, Maria Fernanda Silva Andrade-Bortoletto, Matheus L. Oliveira, Francisco Haiter-Neto, Cleber Zanchettin, Deborah Queiroz Freitas

  • Open Access

    What is the role of AI-driven automation in static surgical guide design? A scoping review

    by Maria Fernanda Silva Andrade-Bortoletto, Xijin Du, Eslam Abdelwahab Dawood, Oana Elena Burlacu Vatamanu, Mihai Tarce, Rocharles Cavalcante Fontenele, Deborah Queiroz Freitas, Reinhilde Jacobs


  • Influence of photostimulable phosphor plate receptor disinfection with peracetic acid on vertical root fracture diagnosis

    by Débora Costa Ruiz, Maria Fernanda Silva Andrade-Bortoletto, Carolina Paes Borge, Thamiles Gonzalez-Passos, Francisco Haiter-Neto, Deborah Queiroz Freitas

    Objectives: To assess the influence of disinfecting a photostimulable phosphor plate (PSP) receptor with 0.2% peracetic acid on the vertical root fracture (VRF) diagnosis. Methods: Baseline radiographs of 20 single-rooted teeth (10 without VRF and 10 with VRF) inserted in an alveolar socket of a human mandible were obtained with an unused PSP receptor of the Express digital system (Instrumentarium Dental Inc., Milwaukee, United States) and a Focus X-ray unit (Instrumentarium, Tuusula, Finland) set at 70 kVp, 7 mA, and an exposure time of 0.125 s. Then, 20 disinfections were performed on the PSP receptor, representing one disinfection cycle. Each disinfection lasted 30 s and the interval between them was 40 min. Subsequently, another 20 radiographs were obtained. This process occurred 9 more times, resulting in 200 disinfections (10 cycles × 20 disinfections) and 220 radiographs ([10 cycles × 20 teeth] + 20 baseline radiographs). All 220 radiographs were assessed independently by 5 examiners for VRF diagnosis. Area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were calculated and compared among the number of disinfections by analysis of variance. The significance level was set at 5%. Weighted Kappa test evaluated intra- and inter-examiner agreements. Results: The disinfections did not affect the AUC, sensitivity and specificity values for VRF diagnosis (P > 0.05). Moreover, the intra- and inter-examiner agreements ranged from moderate to perfect (0.55-1.00) and from fair to moderate (0.22-0.49), respectively. Conclusions: Disinfecting a PSP receptor with 0.2% peracetic acid did not affect the radiographic diagnosis of VRF.