Chen-Cheng Lo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chen-Cheng Lo has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Chi-Hung Lee
Department of Electrical Engineering, Feng Chia University, Taichung 407, Taiwan
2 shared publications - Feng-Chi Lin
Department of Ophthalmology, Kaohsiung Armed Forced General Hospital, Kaohsiung 802, Taiwan
2 shared publications - Shang-Min Yeh
Department of Optometry, Chung Shan Medical University, Taichung 402, Taiwan
2 shared publications - Shuan-Yu Huang
Department of Optometry, Central Taiwan University of Science and Technology, Taichung 406, Taiwan
2 shared publications - Hui-Rong Su
Ph.D. Program of Electrical and Communications Engineering, Feng Chia University, Taichung 407, Taiwan
1 shared publication - Richard Wu
Research and Development Centre, Brighten Optix Corporation, Taipei 111, Taiwan
1 shared publication
Latest Publications
- Open Access
- 3 March 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (5) , 2942
Effects of Extended Viewing Distance on Accommodative Response and Pupil Size of Myopic Adults by Using a Double-Mirror System
Purposes: This study discussed the accommodative response and pupil size of myopic adults using a double-mirror system (DMS). The viewing distance could be extended to 2.285 m by using a DMS, which resulted in a reduction and increase in the accommodative response and pupil size, respectively. By using a DMS, the reduction of the accommodative response could improve eye fatigue with near work. Method: Sixty subjects aged between 18 and 22 years old were recruited in this study, and the average age was 20.67 ± 1.09. There were two main steps in the experimental process. In the first step, we examined the subjects’ refraction state and visual function, and then fitted disposable contact lenses with a corresponding refractive error. In the second step, the subjects gazed at an object from a viewing distance of 0.4 m and at a virtual image through a DMS, respectively, and the accommodative response and pupil size were measured using an open field autorefractor. Results: When the subjects gazed at the object from a distance of 0.4 m, or gazed at the virtual image through a DMS, the mean value of the accommodative response was 1.74 ± 0.43 or 0.16 ± 0.47 D, and the pupil size was 3.98 ± 0.06 mm or 4.18 ± 0.58 mm, respectively. With an increase in the viewing distance from 0.4 m to 2.285 m, the accommodative response and pupil size were significantly reduced about 1.58 D and enlarged about 0.2 mm, respectively. For three asterisk targets of different sizes (1 cm × 1 cm, 2 cm × 2 cm, and 3 cm × 3 cm), the mean accommodative response and pupil size through the DMS was 0.19 ± 0.16, 0.27 ± 0.24, 0.26 ± 0.19 D; and 4.20 ± 1.02, 3.94 ± 0.73, 4.21 ± 0.57 mm, respectively. The changes of the accommodative response and pupil size were not significant with the size of the targets (p > 0.05). In the low or high myopia group, the accommodative response of 0.4 m and 2.285 m was 1.68 ± 0.42 D and 0.21 ± 0.48 D; and 1.88 ± 0.25 D and 0.05 ± 0.40 D, respectively. The accommodative response was significantly reduced by 1.47 D and 1.83 D for these two groups. The accommodative microfluctuations (AMFs) were stable when a DMS was used; on the contrary, the AMFs were unstable at a viewing distance of 0.4 m. Conclusions: In this study, the imaging through a DMS extended the viewing distance and enlarged the image, and resulted in a reduction in the accommodative response and an increase in the pupil size. For the low myopia group and the high myopia group, the accommodative response and pupil size were statistically significantly different before and after the use of the DMS. The reduction of the accommodative response could be applied for the improvement of asthenopia.
- 3 March 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (5) , 2942
Open AccessEffects of Extended Viewing Distance on Accommodative Response and Pupil Size of Myopic Adults by Using a Double-Mirror System
Purposes: This study discussed the accommodative response and pupil size of myopic adults using a double-mirror system (DMS). The viewing distance could be extended to 2.285 m by using a DMS, which resulted in a reduction and increase in the accommodative response and pupil size, respectively. By using a DMS, the reduction of the accommodative response could improve eye fatigue with near work. Method: Sixty subjects aged between 18 and 22 years old were recruited in this study, and the average age was 20.67 ± 1.09. There were two main steps in the experimental process. In the first step, we examined the subjects’ refraction state and visual function, and then fitted disposable contact lenses with a corresponding refractive error. In the second step, the subjects gazed at an object from a viewing distance of 0.4 m and at a virtual image through a DMS, respectively, and the accommodative response and pupil size were measured using an open field autorefractor. Results: When the subjects gazed at the object from a distance of 0.4 m, or gazed at the virtual image through a DMS, the mean value of the accommodative response was 1.74 ± 0.43 or 0.16 ± 0.47 D, and the pupil size was 3.98 ± 0.06 mm or 4.18 ± 0.58 mm, respectively. With an increase in the viewing distance from 0.4 m to 2.285 m, the accommodative response and pupil size were significantly reduced about 1.58 D and enlarged about 0.2 mm, respectively. For three asterisk targets of different sizes (1 cm × 1 cm, 2 cm × 2 cm, and 3 cm × 3 cm), the mean accommodative response and pupil size through the DMS was 0.19 ± 0.16, 0.27 ± 0.24, 0.26 ± 0.19 D; and 4.20 ± 1.02, 3.94 ± 0.73, 4.21 ± 0.57 mm, respectively. The changes of the accommodative response and pupil size were not significant with the size of the targets (p > 0.05). In the low or high myopia group, the accommodative response of 0.4 m and 2.285 m was 1.68 ± 0.42 D and 0.21 ± 0.48 D; and 1.88 ± 0.25 D and 0.05 ± 0.40 D, respectively. The accommodative response was significantly reduced by 1.47 D and 1.83 D for these two groups. The accommodative microfluctuations (AMFs) were stable when a DMS was used; on the contrary, the AMFs were unstable at a viewing distance of 0.4 m. Conclusions: In this study, the imaging through a DMS extended the viewing distance and enlarged the image, and resulted in a reduction in the accommodative response and an increase in the pupil size. For the low myopia group and the high myopia group, the accommodative response and pupil size were statistically significantly different before and after the use of the DMS. The reduction of the accommodative response could be applied for the improvement of asthenopia.
- Open Access
- 22 September 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (19) , 9951
Reduction in Accommodative Response of Schoolchildren by a Double-Mirror System
Purpose: This study first proposed the application of a double-mirror system (DMS) to extend viewing distance and investigate the accommodative response of schoolchildren under a DMS. Method: Fifty-seven subjects aged between 7 and 12 years old were recruited in this study, and the experiment was divided into two stages. The first stage consisted of a case history inquiry, a refraction state, and a visual function examination. In the second stage, the subjects gazed at an object at distances of 0.4 m, 2.285 m, and through a DMS, respectively, and their accommodative responses were measured using an open-field autorefractor. Results: There was no significant difference in the schoolchildren’s accommodative response between subjects gazing at an object at 2.285 m (0.14 ± 0.35 D, p > 0.05) and those gazing at it through a DMS (0.20 ± 0.35 D). However, their accommodative response showed a significant difference between subjects gazing at an object at 0.4 m and 2.285 m and those gazing at it at 0.4 m and through a DMS. Conclusion: In this experiment, the results of the children’s accommodative response measured at 2.285 m or through a DMS are very similar. The viewing distance can be extended by a DMS, resulting in accommodative relaxation. This result may have potential applications in myopia control.
- 22 September 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (19) , 9951
Open AccessReduction in Accommodative Response of Schoolchildren by a Double-Mirror System
Purpose: This study first proposed the application of a double-mirror system (DMS) to extend viewing distance and investigate the accommodative response of schoolchildren under a DMS. Method: Fifty-seven subjects aged between 7 and 12 years old were recruited in this study, and the experiment was divided into two stages. The first stage consisted of a case history inquiry, a refraction state, and a visual function examination. In the second stage, the subjects gazed at an object at distances of 0.4 m, 2.285 m, and through a DMS, respectively, and their accommodative responses were measured using an open-field autorefractor. Results: There was no significant difference in the schoolchildren’s accommodative response between subjects gazing at an object at 2.285 m (0.14 ± 0.35 D, p > 0.05) and those gazing at it through a DMS (0.20 ± 0.35 D). However, their accommodative response showed a significant difference between subjects gazing at an object at 0.4 m and 2.285 m and those gazing at it at 0.4 m and through a DMS. Conclusion: In this experiment, the results of the children’s accommodative response measured at 2.285 m or through a DMS are very similar. The viewing distance can be extended by a DMS, resulting in accommodative relaxation. This result may have potential applications in myopia control.