OSOlga Saiapina

Olga Saiapina

*This is an algorithmically generated author record based on publicly available information.

Olga Saiapina has a total of 29 co-authors. Here are the top co-authors by number of shared publications:

  • Sergei V. Dzyadevych

    Institute of Molecular Biology and Genetics, The National Academy of Sciences of Ukraine, 150 Zabolotnoho Str., 03143 Kyiv, Ukraine

    5 shared publications
  • Oleksandr O. Soldatkin

    Інститут молекулярної біології і генетики НАН України; Національний технічний університет України «Київський політехнічний інститут імені Ігоря Сікорського», Україна

    2 shared publications
  • P.I. Borshchov

    Institute of Electrodynamics National Academy of Sciences of Ukraine, 56, Beresteiskyi Ave., Kyiv, 03057, Ukraine

    2 shared publications
  • Volodymir G. Melnyk

    Institute of Electrodynamics National Academy of Sciences of Ukraine, 56, Beresteiskyi Ave., Kyiv, 03057, Ukraine

    2 shared publications
  • Abdennour Abbas

    Department of Bioproducts and Biosystems Engineering, University of Minnesota, St. Paul, USA

    1 shared publication
  • Aleksandr D Vasylenko

    Department of Electrical and Magnetic Measurements, Institute of Electrodynamics National Academy of Sciences of Ukraine, 56, Peremohy Avenue, Kyiv, 03057, UKRAINE

    1 shared publication

Latest Publications

  • Development and optimization of the novel conductometric (bio)sensors based on natural zeolite for ammonium, urea and L-arginine determination

    by Olga Saiapina

    Développement et optimisation de nouveaux (bio)capteurs conductimétriques basés sur une zéolite naturelle pour la détermination de l’ammonium, de l’urée et de la L-arginine: Le travail de la thèse présente une série de (bio)capteurs conductimétriques, à base de la clinoptilolite, pour la détermination de l’ammonium, de l’urée et de la L-arginine. La clinoptilolite, le matériau nanométrique, possédant des propriétés de la sorption intrinsèque et une capacité d’échange cationique vis-à-vis des espèces ammonium, a été d’abord utilisée pour la réalisation d’un microcapteur conductimétrique sélectif à NH4+. Ci-après, une application de ce nanomatériau dans les biocapteurs est favorable pour le fonctionnement dans les solutions tampons multicomposants. Parmi plusieurs variantes de biocapteurs à l’urée à base de la zéolite, la plus intéressante est le biocapteur, dans lequel la couche de la clinoptilolite, déposée sur le transducteur, a été recouverte par le dépôt de la couche de l’uréase et de la zéolite. Pour l’élaboration d’un biocapteur conductimétrique hautement sensible pour la détermination de la L-arginine, l’arginase et l’uréase ont été co-réticulées sur le transducteur. Une détermination quantitative de la L-arginine dans une solution buvable « Arginine Veyron » a montré un fort accord avec les données fournies par le producteur. Une procédure détaillée de l’optimisation du biocapteur conductimétrique pour la détection de la L-arginine dans le sérum bovin a été proposée. La clinoptilolite a été également appliquée comme un modificateur dans la co-immobilisation de l’arginase et l’uréase pour améliorer les caractéristiques analytiques de biocapteur conductimétriques pour la détermination de la L-arginine

  • Open Access

    ADAPTATION OF MONOENZYME CONDUCTOMETRIC BIOSENSOR FOR HIGHLY SENSITIVE DETERMINATION OF ARGININE IN DIETARY SUPPLEMENTS

    by Kseniia Berketa, Olga Saiapina, Lyubov Fayura, Andriy Sibirny, Sergiy Dzyadevych, Oleksandr Soldatkin, Ольга Саяпіна, Любов Фаюра, Андрій Сибірний, Сергій Дзядевич

    The work describes the development of a monoenzyme conductometric biosensor for the determination of arginine in pharmaceutical samples. The biosensor was created by immobilizing recombinant arginine deiminase (ADI) on electrodes using covalent cross linking in glutaraldehyde vapours. To achieve maximum sensitivity, the influence of the working buffer solution parameters, such as pH, buffer capacity, ionic strength, temperature, and protein concentration, on the operation of the biosensor was investigated. The analytical characteristics, signal reproducibility, and storage stability of the biosensor with the optimized buffer solution were studied. To test the biosensor, arginine in food additives was determined using the standard addition biosensor method. The work shows that the results correlate well with ion-exchange chromatography and enzymatic spectrophotometric analysis. The influence of different sample preparation options on the accuracy of arginine determination was also studied. The biosensor is effective for the accurate determination of arginine in dietary supplements intended to correct its deficiency.

  • Biosensors Practical Application

    by Lyudmyla Shkotova, Oleksandr Soldatkin, Valentyna Arkhypova, Viktoriya Peshkova, Olga Saiapina, Tetyana Sergeyeva, Alexei Soldatkin, Sergei Dzyadevych

    A number of electrochemical mono- and multibiosensors based on different enzymes, living cells and biomimics were developed, and their laboratory prototypes were fabricated and thoroughly investigated for real conditions of application (wine and wine must, natural fruit juices, agricultural, food and environmental water samples, among other options). It is noteworthy that these electrochemical biosensors, represented by miniaturized devices, are adaptable to technologies of large-scale production. Concerning further wide applications of the developed biosensors, the obtained results demonstrate the possibility to modulate their main characteristics to comply with the specific requirements for potential practical purposes. Diverse types of biosensors may be elaborated by using genetically modified enzymes and microorganisms, membranes with different characteristics and nanoscaled materials as well. It is noteworthy that biosensors designed based on our technology may complement and in certain cases substitute, traditional analytical techniques. Biosensors may act as additional systems for fast and early warning devices for the presence of key substances or compounds. Additionally, they can provide a way to save time and costs under urgent conditions due to the necessity of taking rapid decisions concerning local environmental problems. More accurate but time-consuming and more expensive classical methods could be eventually used for further validation and investigation of the samples previously tested by biosensor arrays. The advantages and disadvantages of the biosensors constructed by our group are widely discussed in this chapter.

  • Open Access

    METHOD OF MEASUREMENT OF LOCAL CHANGES IN ELECTRIC CONDUCTIVITY OF SOLUTIONS IN DIFFERENTIAL CONDUCTOMETRIC BIOSENSOR SYSTEMS

    by В.г. Мельник, P.I. Borshchov, S.V. Dzyadevych, O.Y. Saiapina

    A method for measuring local changes in the electrical conductivity of solutions using differential conductometric sensors is considered. The method makes it possible to significantly reduce the measurement error due to changes in the background electrical conductivity of the measuring medium when applying the test substance with non-identical parameters of equivalent electrical circuits of the sensor components. The bridge measuring circuit is brought to a quasi-balanced state, while the voltages in the sections of the working solution of the working and reference transducers of the sensor coincide in phase with each other, and their values are proportional to the conductivity of these sections. At the same time, changes in the background electrical conductivity of the solution do not lead to a change in the imbalance signal of the bridge circuit, which allows measuring the informative local change in the electrical conductivity of the working transducer with high sensitivity. The method can be used for highly sensitive and accurate quantification of solutions of electrically conductive substances in technological processes in the energy, chemical, and food industries, in the latest technologies, in particular in biosensor analyzers. The research results of the experimental sample of the conductometric analyzer are given. Ref. 9, table. Розглянуто спосіб вимірювання локальних змін електропровідності розчинів з використанням диференційних кондуктометричних сенсорів. Спосіб дає можливість за неідентичних параметрів еквівалентних електричних схем компонентів сенсора суттєво знизити похибку вимірювань, зумовлену змінами фонової електропровідності вимірювального середовища під час внесення досліджуваної речовини. Мостове вимірювальне коло приводиться в стан квазірівноваги, водночас напруги на ділянках робочого розчину робочого і референсного перетворювачів сенсора збігаються за фазою між собою, а їхні значення пропорційні значенням електропровідності цих ділянок. Водночас зміни фонової електропровідності розчину не призводять до зміни сигналу нерівноваги мостового кола, що дає змогу вимірювати інформативну локальну зміну електропровідності робочого перетворювача з високою чутливістю. Спосіб може бути використаний для високочутливого і точного визначення кількісного складу розчинів електропровідних речовин у технологічних процесах в енергетиці, хімічній та харчовій промисловості, в новітніх технологіях, зокрема в біосенсорних аналізаторах. Наведено результати комп’ютерного моделювання розробленого способу. Бібл. 9, таблиця.

  • Open Access

    INCREASING THE SENSITIVITY AND METROLOGICAL RELIABILITY OF A DIFFERENTIAL CONDUCTOMETRIC BIOSENSOR SYSTEM

    by В.г. Мельник, P.I. Borshchov, S.V. Dzyadevych, O.YA. Saiapina, O.D. Vasylenko, П.і. Борщов, О.я. Саяпіна

    The differential method of conductometric measurements does not fully solve the problem of the influence of changes in the background electrical conductivity of the working buffer solutions on the results of conversion of the biosensor responses. The variation in the background electrical conductivity of the buffer solution upon addition of the highly conductive analyte acts as a common mode interference and causes the additive error. Here we present a new measurement method and structure of the device for quantification of the analytes that provide a significant decrease in the measurement error associated with a change in the background electrical conductivity caused by the introduction of the analyte to the working solution prior to the generation of the informative signal. A block diagram of the device and a vector model of the balancing process of its measuring circuit are presented. The advantages of the developed method and biosensor analyzer for application within the possible changes of the transducer parameters and measurement conditions are demonstrated. References 28, figures 4.


  • Open Access

    Solutions for enhancement of sensitivity and metrological reliability of conductometric biosensor systems

    by Volodymyr G Melnyk, Aleksandr D Vasylenko, Liudmila N Semenycheva, Oleksandr V Slitskiy, Olga Y Saiapina, Sergei V. Dzyadevych


  • Open Access

    Microbial separation from a complex matrix by a hand-held microfluidic device

    by Renu Singh, John Brockgreitens, Olga Saiapina, Yan Wu, Abdennour Abbas

    Through a simple chemical activation of biomolecules present in the outer structures of microbial cells, microorganisms can be rapidly isolated on gold-coated surfaces in a microfluidic device with over 99% capture efficiency.


  • Open Access

    Potentiality of application of the conductometric L-arginine biosensors for the real sample analysis

    by O. Y. Saiapina, S. V. Dzyadevych, N. Jaffrezic-Renault

    Aim. To determine an influence of serum components on the L-arginine biosensor sensitivity and to formulate practical recommendations for its reliable analysis. Methods. The L-arginine biosensor comprised arginase and urease co-immobilized by cross-linking. Results. The biosensor specificity was investigated based on a series of representative studies (namely, through urea determination in the serum; inhibitory effect studies of mercury ions; high temperature treatment of sensors; studying the biosensor sensitivity to the serum treated by enzymes, and selectivity studies). It was found that the response of the biosensor to the serum injections was determined by high sensitivity of the L-arginine biosensor toward not only to L-arginine but also toward two other basic amino acids (L-lysine and L-histidine). Conclusions. A detailed procedure of optimization of the conductometric biosensor for L-arginine determination in blood serum has been proposed