Felipe Franco Nascimento
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Felipe Franco Nascimento has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Claudia Lizandra Ricci
Postgraduate Program in Animal Science, UNOESTE, Presidente Prudente, São Paulo, Brazil
2 shared publications - Glaucia Prada Kanashiro
Postgraduate Program in Animal Science, UNOESTE, Presidente Prudente, São Paulo, Brazil
2 shared publications - João Victor Goulart Consoni Passareli
Postgraduate Program in Animal Science, UNOESTE, Presidente Prudente, São Paulo, Brazil
2 shared publications - Rogério Giuffrida
Universidade do Oeste Paulista
2 shared publications - Silvia Franco Andrade
Department of Veterinary Ophthalmology, Veterinary Hospital, UNOESTE, Presidente Prudente, São Paulo, Brazil
2 shared publications - Giovana José Garcia Estanho
Postgraduate Program in Animal Science, UNOESTE, Presidente Prudente, SP, Brazil
1 shared publication
Latest Publications
- Open Access
- 20 August 2024
- Published by Veterinary World in Veterinary World
- Vol. 17 (8) , 1803-1809
Comparison of three methodologies for measuring intraocular pressure in healthy cats
Background and Aim: Measuring intraocular pressure (IOP) is crucial for identifying potentially damaging changes in the eyes, including diseases as glaucoma and uveitis. This study compared intraocular pressure (IOP) measurements in cats using the Tonovet and Tonovet Plus (rebound), Tono-Pen Avia Vet (applanation), and Kowa HA-2 (Goldman’s methodology applanation) tonometers. Materials and Methods: 55 healthy cats (108 eyes) were assessed through three distinct studies: An ex vivo experiment (10 eyes of five cats) to correlate IOP manometry and tonometry values and ascertain the correlation coefficient (r2); an in vivo study (10 eyes of five sedated cats) to contrast manometer and tonometer readings; and an outpatient clinical trial (80 eyes of 45 cats) to analyze only tonometer measurements. Results: The r2 values observed in the ex vivo study were Tonovet (0.923), Tonovet Plus (0.925), Tono-Pen Avia Vet (0.877), and Kowa HA-2 (0.901). The IOP values in mmHg in the in vivo study were as follows: Manometer (16.1 ± 2.7), Tonovet (21.1 ± 3.6), Tonovet Plus (19.7 ± 7.2), Tono-Pen Avia Vet (17.6 ± 7.9), and Kowa HA-2 (16.8 ± 2.0). In the outpatient clinical study, the IOP values in mmHg were as follows: Tonovet (19.7 ± 6.6), Tonovet Plus (17.1 ± 5.4), Tono-Pen Avia Vet (16.3 ± 4.3), and Kowa HA-2 (14.5 ± 2.2). Conclusion: IOP and manometry readings were strongly correlated by all tonometers. In the clinical setting, the most and least IOP measurements were recorded using Tonovet and Kowa HA-2, respectively, stressing the importance of an IOP reference table for each tonometer in feline practice. Keywords: applanation tonometry, goldmann tonometry, intraocular pressure, ocular manometry, rebound tonometry.
- 20 August 2024
- Published by Veterinary World in Veterinary World
- Vol. 17 (8) , 1803-1809
Open AccessComparison of three methodologies for measuring intraocular pressure in healthy cats
Background and Aim: Measuring intraocular pressure (IOP) is crucial for identifying potentially damaging changes in the eyes, including diseases as glaucoma and uveitis. This study compared intraocular pressure (IOP) measurements in cats using the Tonovet and Tonovet Plus (rebound), Tono-Pen Avia Vet (applanation), and Kowa HA-2 (Goldman’s methodology applanation) tonometers. Materials and Methods: 55 healthy cats (108 eyes) were assessed through three distinct studies: An ex vivo experiment (10 eyes of five cats) to correlate IOP manometry and tonometry values and ascertain the correlation coefficient (r2); an in vivo study (10 eyes of five sedated cats) to contrast manometer and tonometer readings; and an outpatient clinical trial (80 eyes of 45 cats) to analyze only tonometer measurements. Results: The r2 values observed in the ex vivo study were Tonovet (0.923), Tonovet Plus (0.925), Tono-Pen Avia Vet (0.877), and Kowa HA-2 (0.901). The IOP values in mmHg in the in vivo study were as follows: Manometer (16.1 ± 2.7), Tonovet (21.1 ± 3.6), Tonovet Plus (19.7 ± 7.2), Tono-Pen Avia Vet (17.6 ± 7.9), and Kowa HA-2 (16.8 ± 2.0). In the outpatient clinical study, the IOP values in mmHg were as follows: Tonovet (19.7 ± 6.6), Tonovet Plus (17.1 ± 5.4), Tono-Pen Avia Vet (16.3 ± 4.3), and Kowa HA-2 (14.5 ± 2.2). Conclusion: IOP and manometry readings were strongly correlated by all tonometers. In the clinical setting, the most and least IOP measurements were recorded using Tonovet and Kowa HA-2, respectively, stressing the importance of an IOP reference table for each tonometer in feline practice. Keywords: applanation tonometry, goldmann tonometry, intraocular pressure, ocular manometry, rebound tonometry.
- Open Access
- 21 September 2021
- Published by Veterinary World in Veterinary World
- Vol. 14 (9) , 2444-2451
Comparison among TonoVet, TonoVet Plus, Tono-Pen Avia Vet, and Kowa HA-2 portable tonometers for measuring intraocular pressure in dogs
Background and Aim: Tonometers are an important instrument for measuring intraocular pressure (IOP) in the diagnosis of glaucoma or uveitis. This study aimed to compare the accuracy of the main types of tonometers with different IOP measurement methodologies in dogs: TonoVet and TonoVet Plus (rebound), Tono-Pen Avia Vet (applanation), and Kowa HA-2 (Goldmann applanation). Materials and Methods: IOP was measured in 152 eyes of 76 dogs. A postmortem study was performed by comparing manometry and tonometry values and calculating the correlation coefficient (r2), in vivo real IOP (manometry) among the tonometers was compared, and an outpatient study was conducted with healthy eyes and eyes with signs of glaucoma and uveitis. Results: In the postmortem study, the values of r2 in descending order were Kowa (0.989), TonoVet Plus (0.984), TonoVet (0.981), and Tono-Pen Avia Vet (0.847). The IOP values in mmHg in the in vivo study were as follows: Aneroid manometer (16.8±2.5.7), TonoVet (18.1±2.9), TonoVet Plus (20.6±2.3), Tono-Pen Avia Vet (17.1±2.5), and Kowa (16.1±1.7); in outpatient clinics: TonoVet (16.8±3.8), TonoVet Plus (19.2±2.9), Tono-Pen Avia Vet (16.2±2.4), and Kowa (15.0±1.3); glaucoma: TonoVet (30.2±3.5), TonoVet Plus (35.0±6.1), Tono-Pen Avia Vet (29.5±4.2), and Kowa (23.9±5.0); and uveitis: TonoVet (14.2±1.4), TonoVet Plus (17.6±1.9), Tono-Pen Avia Vet (13.7±2.1), and Kowa (12.6±1.7). Conclusion: There was a strong correlation between IOP values and manometry in all the tonometers. The highest values were obtained with TonoVet Plus and the lowest with Kowa HA-2. All tonometers accurately measured IOP in dogs, including the latest TonoVet Plus, which showed an excellent correlation coefficient.
- 21 September 2021
- Published by Veterinary World in Veterinary World
- Vol. 14 (9) , 2444-2451
Open AccessComparison among TonoVet, TonoVet Plus, Tono-Pen Avia Vet, and Kowa HA-2 portable tonometers for measuring intraocular pressure in dogs
Background and Aim: Tonometers are an important instrument for measuring intraocular pressure (IOP) in the diagnosis of glaucoma or uveitis. This study aimed to compare the accuracy of the main types of tonometers with different IOP measurement methodologies in dogs: TonoVet and TonoVet Plus (rebound), Tono-Pen Avia Vet (applanation), and Kowa HA-2 (Goldmann applanation). Materials and Methods: IOP was measured in 152 eyes of 76 dogs. A postmortem study was performed by comparing manometry and tonometry values and calculating the correlation coefficient (r2), in vivo real IOP (manometry) among the tonometers was compared, and an outpatient study was conducted with healthy eyes and eyes with signs of glaucoma and uveitis. Results: In the postmortem study, the values of r2 in descending order were Kowa (0.989), TonoVet Plus (0.984), TonoVet (0.981), and Tono-Pen Avia Vet (0.847). The IOP values in mmHg in the in vivo study were as follows: Aneroid manometer (16.8±2.5.7), TonoVet (18.1±2.9), TonoVet Plus (20.6±2.3), Tono-Pen Avia Vet (17.1±2.5), and Kowa (16.1±1.7); in outpatient clinics: TonoVet (16.8±3.8), TonoVet Plus (19.2±2.9), Tono-Pen Avia Vet (16.2±2.4), and Kowa (15.0±1.3); glaucoma: TonoVet (30.2±3.5), TonoVet Plus (35.0±6.1), Tono-Pen Avia Vet (29.5±4.2), and Kowa (23.9±5.0); and uveitis: TonoVet (14.2±1.4), TonoVet Plus (17.6±1.9), Tono-Pen Avia Vet (13.7±2.1), and Kowa (12.6±1.7). Conclusion: There was a strong correlation between IOP values and manometry in all the tonometers. The highest values were obtained with TonoVet Plus and the lowest with Kowa HA-2. All tonometers accurately measured IOP in dogs, including the latest TonoVet Plus, which showed an excellent correlation coefficient.