Steffan Møller Sønderskov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Steffan Møller Sønderskov has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Mingdong Dong
Aarhus University
2 shared publications - Aleksandra Bednarz
Interdisciplinary Nanoscience Center (iNANO) and Department of Chemistry, Aarhus University, 8000 Aarhus, Denmark
1 shared publication - Hüsnü Aslan
Dansk Fundamental Metrologi (DFM) – Danish National Metrology Institute, Hoersholm, Denmark
1 shared publication - Lasse Hyldgaard Klausen
Aarhus University
1 shared publication - Poul-Erik Hansen
Dansk Fundamental Metrologi A/S
1 shared publication - Thomas Fuhs
Institute for Bioprocessing and Analytical Measurement Techniques, Rosenhof, Heilbad Heiligenstadt, 37308, Germany
1 shared publication
Latest Publications
- Open Access
- 8 July 2026
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (3) , 035010
Correlative confocal and atomic force microscopy imaging for particle metrology: theory and measurements
Accurate and traceable determination of particle diameters is essential for environmental monitoring, pharmaceutical manufacturing, cleanroom contamination control and other critical infrastructure. Atomic force microscopy (AFM) provides a tactile solution for particle size calibration with the lowest measurement uncertainty and the highest spatial resolution in air; however, its practical application is constrained by limited scan range, low throughput, and challenges in reliably measuring particles larger than approximately 10 μ m. In contrast, high-throughput optical techniques such as laser scanning confocal microscopy (LSCM) offer large fields of view and extended measurement ranges but lack the resolution needed for dimensional particle metrology and measurements on translucent samples pose added challenges. Here, we present a correlative metrology framework that enables traceable calibration transfer between AFM and LSCM for translucent microparticles. By combining physics-informed modeling of near-field and confocal imaging effects with Bayesian inference for particle size estimation, we quantify and mitigate optical measurement biases and establish a statistically robust link between the two modalities. Using polystyrene particle standards, we demonstrate traceable size measurements across a range from 3 μ m to 20 μ m, extending the effective measurement capability beyond the practical limits of both instruments while maintaining the calculation of the expanded measurement uncertainty. This approach provides a general pathway for integrating high-throughput optical microscopy with high-resolution tactile metrology and highlights the role of physics-based modeling and probabilistic inference in enabling reliable dimensional measurements of complex objects.
- 8 July 2026
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (3) , 035010
Open AccessCorrelative confocal and atomic force microscopy imaging for particle metrology: theory and measurements
Accurate and traceable determination of particle diameters is essential for environmental monitoring, pharmaceutical manufacturing, cleanroom contamination control and other critical infrastructure. Atomic force microscopy (AFM) provides a tactile solution for particle size calibration with the lowest measurement uncertainty and the highest spatial resolution in air; however, its practical application is constrained by limited scan range, low throughput, and challenges in reliably measuring particles larger than approximately 10 μ m. In contrast, high-throughput optical techniques such as laser scanning confocal microscopy (LSCM) offer large fields of view and extended measurement ranges but lack the resolution needed for dimensional particle metrology and measurements on translucent samples pose added challenges. Here, we present a correlative metrology framework that enables traceable calibration transfer between AFM and LSCM for translucent microparticles. By combining physics-informed modeling of near-field and confocal imaging effects with Bayesian inference for particle size estimation, we quantify and mitigate optical measurement biases and establish a statistically robust link between the two modalities. Using polystyrene particle standards, we demonstrate traceable size measurements across a range from 3 μ m to 20 μ m, extending the effective measurement capability beyond the practical limits of both instruments while maintaining the calculation of the expanded measurement uncertainty. This approach provides a general pathway for integrating high-throughput optical microscopy with high-resolution tactile metrology and highlights the role of physics-based modeling and probabilistic inference in enabling reliable dimensional measurements of complex objects.
- 8 December 2022
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 15 (3) , 1317-1326
Ion-mediated control of structural integrity and reconfigurability of DNA nanostructures
Nucleic acid-based biomolecular self-assembly enables the creation of versatile functional architectures. Electrostatic screening of the negative charges of nucleic acids is essential for their folding and stability; thus, ions play a critical role in nucleic acid self-assembly in both biology and nanotechnology. However, the ion–DNA interplay and the resulting ion-specific structural integrity and responsiveness of DNA constructs are underexploited. Here, we harness a wide range of mono- and divalent ions to control the structural features of DNA origami constructs. Using atomic force microscopy and Förster resonance energy transfer (FRET) spectroscopy down to the single-molecule level, we report on the global and local structural performance and responsiveness of DNA origami constructs following self-assembly, upon post-assembly ion exchange and post-assembly ion-mediated reconfiguration. We determined the conditions for highly efficient DNA origami folding in the presence of several mono- (Li+, Na+, K+, Cs+) and divalent (Ca2+, Sr2+, Ba2+) ions, expanding the range where DNA origami structures can be exploited for custom-specific applications. We then manipulated fully folded constructs by exposing them to unfavorable ionic conditions that led to the emergence of substantial disintegrity but not to unfolding. Moreover, we found that poorly assembled nanostructures at low ion concentrations undergo substantial self-repair upon ion addition in the absence of free staple strands. This reconfigurability occurs in an ion type- and concentration-specific manner. Our findings provide a fundamental understanding of the ion-mediated structural responsiveness of DNA origami at the nanoscale enabling applications under a wide range of ionic conditions.
- 8 December 2022
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 15 (3) , 1317-1326
Ion-mediated control of structural integrity and reconfigurability of DNA nanostructures
Nucleic acid-based biomolecular self-assembly enables the creation of versatile functional architectures. Electrostatic screening of the negative charges of nucleic acids is essential for their folding and stability; thus, ions play a critical role in nucleic acid self-assembly in both biology and nanotechnology. However, the ion–DNA interplay and the resulting ion-specific structural integrity and responsiveness of DNA constructs are underexploited. Here, we harness a wide range of mono- and divalent ions to control the structural features of DNA origami constructs. Using atomic force microscopy and Förster resonance energy transfer (FRET) spectroscopy down to the single-molecule level, we report on the global and local structural performance and responsiveness of DNA origami constructs following self-assembly, upon post-assembly ion exchange and post-assembly ion-mediated reconfiguration. We determined the conditions for highly efficient DNA origami folding in the presence of several mono- (Li+, Na+, K+, Cs+) and divalent (Ca2+, Sr2+, Ba2+) ions, expanding the range where DNA origami structures can be exploited for custom-specific applications. We then manipulated fully folded constructs by exposing them to unfavorable ionic conditions that led to the emergence of substantial disintegrity but not to unfolding. Moreover, we found that poorly assembled nanostructures at low ion concentrations undergo substantial self-repair upon ion addition in the absence of free staple strands. This reconfigurability occurs in an ion type- and concentration-specific manner. Our findings provide a fundamental understanding of the ion-mediated structural responsiveness of DNA origami at the nanoscale enabling applications under a wide range of ionic conditions.
- 25 January 2018
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 10 (9) , 4538-4544
Direct measurement of surface charge distribution in phase separating supported lipid bilayers
The local surface charge density of the cell membrane influences regulation and localization of membrane proteins.
- 25 January 2018
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 10 (9) , 4538-4544
Direct measurement of surface charge distribution in phase separating supported lipid bilayers
The local surface charge density of the cell membrane influences regulation and localization of membrane proteins.