Qi Ding
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qi Ding has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Wendong Zhang
North University of China
4 shared publications - Changde He
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan 030051, China
2 shared publications Feng Zhang
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan, China
2 shared publications- Hongliang Wang
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan 030051, China
2 shared publications - Hongliang Wang
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan, China
2 shared publications - Tao Liu
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan, China
2 shared publications
Latest Publications
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (16) , 1
A CMUT-Based Dual-mode Sensor with Wide Range and High Sensitivity for Absolute Pressure Measurement
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (16) , 1
A CMUT-Based Dual-mode Sensor with Wide Range and High Sensitivity for Absolute Pressure Measurement
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (15) , 1
Performance Enhancement Strategies for Resonant Absolute Pressure Sensor
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (15) , 1
Performance Enhancement Strategies for Resonant Absolute Pressure Sensor
- Open Access
- 30 October 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (11) , 1340
Research on Novel CMUTs for Detecting Micro-Pressure with Ultra-High Sensitivity and Linearity
Capacitive micromachined ultrasonic transducers (CMUTs) have been indispensable owing to their resonance characteristics in the MHz frequency range. However, the inferior pressure sensitivity and linearity of traditional CMUTs themselves cannot meet the actual demands of micro-pressure measurements. In this paper, two novel CMUTs are proposed for the first time to improve the measuring performance of micro-pressure in the range of 0–10 kPa. The core concept of the enhancement is strengthening membrane deformability by partly adjusting the CMUT framework under the combined action of electrostatic force and uniform pressure. Two modified structures of an inverted frustum cone-like cavity and slotted membrane are presented, respectively, and a finite element model (FEM) of CMUT was constructed and analyzed using COMSOL Multiphysics 5.5. The results demonstrate that the maximum displacement and pressure sensitivity are improved by 16.01% and 30.79% for the frustum cone-like cavity and 104.22% and 1861.31% for the slotted membrane, respectively. Furthermore, the results show that the width uniformity of the grooves does not influence the characteristics of the membrane, which mainly depend on the total width of the grooves, greatly enriching design flexibility. In brief, the proposed structural designs can significantly improve the micro-pressure measurement performance of the CMUT, which will accelerate the rapid breakthrough of technical barriers in the fields of aerospace, industry control, and other sensing domains.
- 30 October 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (11) , 1340
Open AccessResearch on Novel CMUTs for Detecting Micro-Pressure with Ultra-High Sensitivity and Linearity
Capacitive micromachined ultrasonic transducers (CMUTs) have been indispensable owing to their resonance characteristics in the MHz frequency range. However, the inferior pressure sensitivity and linearity of traditional CMUTs themselves cannot meet the actual demands of micro-pressure measurements. In this paper, two novel CMUTs are proposed for the first time to improve the measuring performance of micro-pressure in the range of 0–10 kPa. The core concept of the enhancement is strengthening membrane deformability by partly adjusting the CMUT framework under the combined action of electrostatic force and uniform pressure. Two modified structures of an inverted frustum cone-like cavity and slotted membrane are presented, respectively, and a finite element model (FEM) of CMUT was constructed and analyzed using COMSOL Multiphysics 5.5. The results demonstrate that the maximum displacement and pressure sensitivity are improved by 16.01% and 30.79% for the frustum cone-like cavity and 104.22% and 1861.31% for the slotted membrane, respectively. Furthermore, the results show that the width uniformity of the grooves does not influence the characteristics of the membrane, which mainly depend on the total width of the grooves, greatly enriching design flexibility. In brief, the proposed structural designs can significantly improve the micro-pressure measurement performance of the CMUT, which will accelerate the rapid breakthrough of technical barriers in the fields of aerospace, industry control, and other sensing domains.
- Open Access
- 29 September 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (10) , 1180
Hybrid Cell Structure for Wideband CMUT: Design Method and Characteristic Analysis
Capacitive micromachined ultrasonic transducer (CMUT) is an ultrasonic transducer based on the microelectromechanical system (MEMS). Wideband CMUT has good application prospects in ultrasonic imaging, ultrasonic identification, flow measurement, and nondestructive testing due to its excellent characteristics. This paper studies the method of increasing the bandwidth of the CMUT, proposes the structure of the wideband CMUT with a hybrid cell structure, and analyzes the design principles and characteristics of the wideband CMUT structure. By changing the cell spacing and the number of cells of different sizes composing the CMUT, we analyze the simulation of the effect of the spacing and number on the CMUT bandwidth, thereby optimizing the bandwidth characteristics of the CMUT. Next, the selection principle of the main structural parameters of the wideband CMUT is analyzed. According to the proposed principle, the CMUT in the air and water are designed and simulated. The results prove that both the air and water CMUT meet the design requirements. The design rules obtained in this paper can provide theoretical guidance for the selection of the main structural parameters of the wideband CMUT.
- 29 September 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (10) , 1180
Open AccessHybrid Cell Structure for Wideband CMUT: Design Method and Characteristic Analysis
Capacitive micromachined ultrasonic transducer (CMUT) is an ultrasonic transducer based on the microelectromechanical system (MEMS). Wideband CMUT has good application prospects in ultrasonic imaging, ultrasonic identification, flow measurement, and nondestructive testing due to its excellent characteristics. This paper studies the method of increasing the bandwidth of the CMUT, proposes the structure of the wideband CMUT with a hybrid cell structure, and analyzes the design principles and characteristics of the wideband CMUT structure. By changing the cell spacing and the number of cells of different sizes composing the CMUT, we analyze the simulation of the effect of the spacing and number on the CMUT bandwidth, thereby optimizing the bandwidth characteristics of the CMUT. Next, the selection principle of the main structural parameters of the wideband CMUT is analyzed. According to the proposed principle, the CMUT in the air and water are designed and simulated. The results prove that both the air and water CMUT meet the design requirements. The design rules obtained in this paper can provide theoretical guidance for the selection of the main structural parameters of the wideband CMUT.