Bajirao Gawali
Bajirao Gawali has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Prateek Deoman Malwe
Department of Mechanical Engineering, COEP Technological University, Shivaji Nagar, Pune 411005, Maharashtra, India
4 shared publications - Rustam Dhalait
Department of Mechanical Engineering, Walchand College of Engineering, Sangli, 416415, India
4 shared publications - Mahmadrafik Choudhari
Department of Mechanical Engineering, Walchand College of Engineering, Sangli, 416415, India
3 shared publications - Nandkishor Sheshrao Deshmukh
Department of Mechanical Engineering, Walchand College of Engineering, Sangli, 416415, India
3 shared publications - Jitendra D. Patil
Army Institute of Technology
2 shared publications - Girish Kapse
Department of Electronics and Telecommunication, Army Institute of Technology, Pune, Maharashtra, India
1 shared publication
Latest Publications
- 5 May 2023
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 9 (3) , 580-592
Second order cyclic analysis of counter flow pulse tube refrigerator
Stirling machines are ecologically propitious refrigeration devices that utilize natural gases like helium, nitrogen, or air. Stirling machines are active refrigerators that should be designed with minimal vibrations and durability in order to fulfil current and future commercial de-mands and requirements. The present paper deals with the modification of the inertance pulse tube refrigerator in which the reservoir is eliminated and replaced with another pulse tube refrigerator. These two pulse tube refrigerators are operated at 180 degrees out of phase, called counter-flow pulse tube refrigerators (CFPTR). The second-order cyclic analysis approach is used to develop a mathematical model for evaluating the performance of CFPTR. This paper describes a modified second-order cyclic approach in detail. The performance of CFPTR is evaluated by estimating the ideal refrigerating effect, ideal power input, and losses individual-ly, yielding net power input and net refrigerating effect. The net refrigerating effect of 30.88W at 70K is obtained with the percentage of Carnot COP of 13.71. The CFD modeling of CFPTR is used to corroborate the second order cyclic model.
- 5 May 2023
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 9 (3) , 580-592
Second order cyclic analysis of counter flow pulse tube refrigerator
Stirling machines are ecologically propitious refrigeration devices that utilize natural gases like helium, nitrogen, or air. Stirling machines are active refrigerators that should be designed with minimal vibrations and durability in order to fulfil current and future commercial de-mands and requirements. The present paper deals with the modification of the inertance pulse tube refrigerator in which the reservoir is eliminated and replaced with another pulse tube refrigerator. These two pulse tube refrigerators are operated at 180 degrees out of phase, called counter-flow pulse tube refrigerators (CFPTR). The second-order cyclic analysis approach is used to develop a mathematical model for evaluating the performance of CFPTR. This paper describes a modified second-order cyclic approach in detail. The performance of CFPTR is evaluated by estimating the ideal refrigerating effect, ideal power input, and losses individual-ly, yielding net power input and net refrigerating effect. The net refrigerating effect of 30.88W at 70K is obtained with the percentage of Carnot COP of 13.71. The CFD modeling of CFPTR is used to corroborate the second order cyclic model.
- 27 March 2023
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 45 (1) , 3154-3169
Experimental investigation of rectangular mini channel array as an effective tool for energy efficient cooling of electronic gadgets
In this paper, an experimental investigation of heat transfer and fluid flow analysis of rectangular mini channel array under steady flow condition is carried out. The channel dimensions are selected in such a way that, flow within the channel is maintained hydro dynamically developed and thermally developing. This type of flow gives enhancement in heat transfer with considerably reduced frictional pressure loss. This study indicates that with a mini channel array maximum heat flux dissipation is extended up to 1.5 MW/m2 at a pressure drop of 8.671kPa. In addition to this, enhancement of heat transfer per unit pumping power (Q/Pp) is also increased by three fold for average heat flux dissipation of 1.25 MW/m2 as against 0.6 MW/m2 at Re = 191. Total minimum thermal resistance reported in this experimentation is 0.128K/W, which is less than the maximum estimated thermal resistance of 0.132K/W for processor having predicted thermal design power (TDP) value of 303. Increase of average heat flux dissipation and reduction in thermal resistance at higher Re (Re > 400) result in substantially reduction in junction temperature Tj(<338K). This results into increase in reliability and sustainability of high heat flux generating electronic gadgets with increase in speed of performing arithmetic computational capabilities.
- 27 March 2023
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 45 (1) , 3154-3169
Experimental investigation of rectangular mini channel array as an effective tool for energy efficient cooling of electronic gadgets
In this paper, an experimental investigation of heat transfer and fluid flow analysis of rectangular mini channel array under steady flow condition is carried out. The channel dimensions are selected in such a way that, flow within the channel is maintained hydro dynamically developed and thermally developing. This type of flow gives enhancement in heat transfer with considerably reduced frictional pressure loss. This study indicates that with a mini channel array maximum heat flux dissipation is extended up to 1.5 MW/m2 at a pressure drop of 8.671kPa. In addition to this, enhancement of heat transfer per unit pumping power (Q/Pp) is also increased by three fold for average heat flux dissipation of 1.25 MW/m2 as against 0.6 MW/m2 at Re = 191. Total minimum thermal resistance reported in this experimentation is 0.128K/W, which is less than the maximum estimated thermal resistance of 0.132K/W for processor having predicted thermal design power (TDP) value of 303. Increase of average heat flux dissipation and reduction in thermal resistance at higher Re (Re > 400) result in substantially reduction in junction temperature Tj(<338K). This results into increase in reliability and sustainability of high heat flux generating electronic gadgets with increase in speed of performing arithmetic computational capabilities.
- Open Access
- 31 January 2023
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 9 (1) , 1-11
Performance analysis and exergy assessment of an inertance pulse tube cryocooler
The world is facing the problems of the energy crisis. Thermal analysis and energy conservation of the engineering devices help to improve their performance. This paper conducted an experimental investigation for the performance analysis and exergy assessment of an Inertance Pulse Tube Cryocooler (IPTC) that uses working fluid -helium operated between 80 K cold end side temperature and room temperature.The variation of the different performance parameters like the effect of charge pressure, pulse tube volume, pulse tube length, etc., and its effect on the refrigerating effect isdescribed graphically. Exergy analysis involves the use and concepts of energy andexergy balances, enthalpy, entropy, and exergy calculations at various stages in thesystem. Exergy analysis identifies the zones of key exergy destruction that occurs insidethe system, which afterward can be subjected to its minimization to amend the systemperformance. The actual exergy efficiency value calculated for the overall system is 21.30 %. The decreasing order of exergy efficiency among the different components is acompressor (38.79 %), a hot end heat exchanger (6.19 %), regenerator, pulse tube andinertance tube (6 %), and cold end heat exchanger (2.70 %).
- 31 January 2023
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 9 (1) , 1-11
Open AccessPerformance analysis and exergy assessment of an inertance pulse tube cryocooler
The world is facing the problems of the energy crisis. Thermal analysis and energy conservation of the engineering devices help to improve their performance. This paper conducted an experimental investigation for the performance analysis and exergy assessment of an Inertance Pulse Tube Cryocooler (IPTC) that uses working fluid -helium operated between 80 K cold end side temperature and room temperature.The variation of the different performance parameters like the effect of charge pressure, pulse tube volume, pulse tube length, etc., and its effect on the refrigerating effect isdescribed graphically. Exergy analysis involves the use and concepts of energy andexergy balances, enthalpy, entropy, and exergy calculations at various stages in thesystem. Exergy analysis identifies the zones of key exergy destruction that occurs insidethe system, which afterward can be subjected to its minimization to amend the systemperformance. The actual exergy efficiency value calculated for the overall system is 21.30 %. The decreasing order of exergy efficiency among the different components is acompressor (38.79 %), a hot end heat exchanger (6.19 %), regenerator, pulse tube andinertance tube (6 %), and cold end heat exchanger (2.70 %).
- 25 August 2022
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 44 (3) , 7598-7619
Oscillating flow heat transfer: a comprehensive review
The oscillating flow heat transfer (OFHT) has been an area of interest to researchers for the last four decades due to the substantial improvement in the performance of such devices. The present paper reviews oscillatory flow heat transfer in detail by considering the type of interaction medium, design, and applications as essential criteria. This paper also overviews the role of oscillating flow heat transfer in the various heat exchanger types such as packed beds, parallel plate channels, finned tubes, ribbed tubes, and the application. Oscillating flow heat exchanger performance mainly depends on oscillation frequency, tidal displacement, axial temperature gradient, tube dimension, and fluid properties. The results of these investigations over a period of five decade are presented in terms of performance indicators viz. enhancement of effective thermal diffusivity by 17,900 folds, Heat flux from 60 to 104 W/m2, axial temperature gradient of 200 K/m, and Nusselt number of 65.93 to 139.8. The significant enhancement in the performance of OFHT is due to combined effect of increase in periodic lateral heat conduction and longitudinal convection due to flow oscillation in presence of axial temperature gradient. The design of the compact system is possible because of significant enhancement in these performance indicators. The significance of this mode of heat transfer is widely known in applications such as Stirling machines, cryogenic refrigerators, or pulsed-tube cryocoolers. Furthermore, heat transfer improvement through oscillatory and pulsating flows is essential in many fields of chemical and mechanical applications where a compact and efficient system is required. This study will benefit new researchers in the understanding of the oscillating flow heat transfer mechanism and the variety of applications for such heat exchangers.
- 25 August 2022
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 44 (3) , 7598-7619
Oscillating flow heat transfer: a comprehensive review
The oscillating flow heat transfer (OFHT) has been an area of interest to researchers for the last four decades due to the substantial improvement in the performance of such devices. The present paper reviews oscillatory flow heat transfer in detail by considering the type of interaction medium, design, and applications as essential criteria. This paper also overviews the role of oscillating flow heat transfer in the various heat exchanger types such as packed beds, parallel plate channels, finned tubes, ribbed tubes, and the application. Oscillating flow heat exchanger performance mainly depends on oscillation frequency, tidal displacement, axial temperature gradient, tube dimension, and fluid properties. The results of these investigations over a period of five decade are presented in terms of performance indicators viz. enhancement of effective thermal diffusivity by 17,900 folds, Heat flux from 60 to 104 W/m2, axial temperature gradient of 200 K/m, and Nusselt number of 65.93 to 139.8. The significant enhancement in the performance of OFHT is due to combined effect of increase in periodic lateral heat conduction and longitudinal convection due to flow oscillation in presence of axial temperature gradient. The design of the compact system is possible because of significant enhancement in these performance indicators. The significance of this mode of heat transfer is widely known in applications such as Stirling machines, cryogenic refrigerators, or pulsed-tube cryocoolers. Furthermore, heat transfer improvement through oscillatory and pulsating flows is essential in many fields of chemical and mechanical applications where a compact and efficient system is required. This study will benefit new researchers in the understanding of the oscillating flow heat transfer mechanism and the variety of applications for such heat exchangers.
- 20 December 2021
- Published by Yildiz Technical University in Journal of Thermal Engineering
- p. 921-932
Second order cyclic analysis of counter flow pulse tube refrigerator
Stirling machines are ecologically propitious refrigeration devices that utilize natural gases like helium, nitrogen, or air. Stirling machines are active refrigerators that should be designed with minimal vibrations and durability in order to fulfil current and future commercial de-mands and requirements. The present paper deals with the modification of the inertance pulse tube refrigerator in which the reservoir is eliminated and replaced with another pulse tube refrigerator. These two pulse tube refrigerators are operated at 180 degrees out of phase, called counter-flow pulse tube refrigerators (CFPTR). The second-order cyclic analysis approach is used to develop a mathematical model for evaluating the performance of CFPTR. This paper describes a modified second-order cyclic approach in detail. The performance of CFPTR is evaluated by estimating the ideal refrigerating effect, ideal power input, and losses individual-ly, yielding net power input and net refrigerating effect. The net refrigerating effect of 30.88W at 70K is obtained with the percentage of Carnot COP of 13.71. The CFD modeling of CFPTR is used to corroborate the second order cyclic model.
- 20 December 2021
- Published by Yildiz Technical University in Journal of Thermal Engineering
- p. 921-932
Second order cyclic analysis of counter flow pulse tube refrigerator
Stirling machines are ecologically propitious refrigeration devices that utilize natural gases like helium, nitrogen, or air. Stirling machines are active refrigerators that should be designed with minimal vibrations and durability in order to fulfil current and future commercial de-mands and requirements. The present paper deals with the modification of the inertance pulse tube refrigerator in which the reservoir is eliminated and replaced with another pulse tube refrigerator. These two pulse tube refrigerators are operated at 180 degrees out of phase, called counter-flow pulse tube refrigerators (CFPTR). The second-order cyclic analysis approach is used to develop a mathematical model for evaluating the performance of CFPTR. This paper describes a modified second-order cyclic approach in detail. The performance of CFPTR is evaluated by estimating the ideal refrigerating effect, ideal power input, and losses individual-ly, yielding net power input and net refrigerating effect. The net refrigerating effect of 30.88W at 70K is obtained with the percentage of Carnot COP of 13.71. The CFD modeling of CFPTR is used to corroborate the second order cyclic model.
- 1 October 2021
- Published by Taylor & Francis in Chemical Engineering Communications
- Vol. 210 (5) , 837-865
Exergy assessment of an Organic Rankine Cycle for waste heat recovery from a refrigeration system: a review
The increased use of fossil fuels in the industry has resulted in severe environmental issues, such as ozone depletion, air pollution, and climate change, among others. Due to diverse resources, such as biomass, solar radiation, and so on, approximately half of the energy produced worldwide is discarded as heat. Utilizing this waste energy as heat reduces fuel usage, reduces carbon dioxide (CO2) emissions, and improves overall system performance. The Organic Rankine Cycle (ORC) is the most efficient and reliable method of converting waste heat from low and medium temperatures into usable power. Exergy refers to the maximum amount of work a system can perform in any state and any environment. Engineers are employing exergy analysis to optimize every system, according to recent research. It comprises assessing and improving system performance utilizing exergy basics, equation balance, and exergy efficiencies. It also facilitates identifying critical sources of exergy loss, which may subsequently be targeted for reduction. This study provides an overview of the exergetic assessment of vapor compression refrigeration systems (VCRS) utilizing ORC. The thermodynamic, environmental, and selection features of 29 different organic fluids, as well as their selection corresponding to the heat source temperatures, are all discussed in this article. The findings of this research include a comparison of these refrigerants under various operating conditions. The primary purpose of this research is to provide a full ORC review for discarded heat retrieval from a refrigeration system, which includes benchmarks for working fluid selection and the impact of operating limits.
- 1 October 2021
- Published by Taylor & Francis in Chemical Engineering Communications
- Vol. 210 (5) , 837-865
Exergy assessment of an Organic Rankine Cycle for waste heat recovery from a refrigeration system: a review
The increased use of fossil fuels in the industry has resulted in severe environmental issues, such as ozone depletion, air pollution, and climate change, among others. Due to diverse resources, such as biomass, solar radiation, and so on, approximately half of the energy produced worldwide is discarded as heat. Utilizing this waste energy as heat reduces fuel usage, reduces carbon dioxide (CO2) emissions, and improves overall system performance. The Organic Rankine Cycle (ORC) is the most efficient and reliable method of converting waste heat from low and medium temperatures into usable power. Exergy refers to the maximum amount of work a system can perform in any state and any environment. Engineers are employing exergy analysis to optimize every system, according to recent research. It comprises assessing and improving system performance utilizing exergy basics, equation balance, and exergy efficiencies. It also facilitates identifying critical sources of exergy loss, which may subsequently be targeted for reduction. This study provides an overview of the exergetic assessment of vapor compression refrigeration systems (VCRS) utilizing ORC. The thermodynamic, environmental, and selection features of 29 different organic fluids, as well as their selection corresponding to the heat source temperatures, are all discussed in this article. The findings of this research include a comparison of these refrigerants under various operating conditions. The primary purpose of this research is to provide a full ORC review for discarded heat retrieval from a refrigeration system, which includes benchmarks for working fluid selection and the impact of operating limits.