Friedrich Scholz
Research Subjects
Friedrich Scholz has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Hofmann
IMMS Institut für Mikroelektronik- und Mechatronik-Systeme gemeinnützige GmbH (IMMS GmbH), Ilmenau, Germany
3 shared publications - Alexander Rolapp
IMMS Institut für Mikroelektronik- und Mechatronik-Systeme gemeinnützige GmbH (IMMS GmbH), Ilmenau, Germany
3 shared publications - Eric Schafer
IMMS Institut für Mikroelektronik- und Mechatronik-Systeme gemeinnützige GmbH (IMMS GmbH), Ilmenau, Germany
3 shared publications - Peggy Reich
IMMS Institut für Mikroelektronik- und Mechatronik-Systeme gemeinnützige GmbH (IMMS GmbH), Ilmenau, Germany
3 shared publications - Georg Gläser
IMMS Institut fr Mikroelektronik- und Mechatronik-Systeme gemeinntzige GmbH (IMMS GmbH),Ilmenau,Germany
2 shared publications - Marco Reinhard
IMMS Institut fr Mikroelektronik- und Mechatronik-Systeme gemeinntzige GmbH (IMMS GmbH), Ilmenau, Germany
2 shared publications
Latest Publications
- Open Access
- 21 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 16 (4) , 535-544
Lock-In Pixel CMOS Image Sensor for Time-Resolved Fluorescence Readout of Lateral-Flow Assays
We present a CMOS image sensor (CIS) based time-resolved fluorescence (TRF) measurement system for filter-less, highly sensitive readout of lateral-flow assay (LFA) test strips. The CIS contains a 256 × 128 lock-in pixel (LIP) sensor array. Each pixel has a size of $10 \ {\mu }\mathrm{m}$ × $10 \ {\mu }\mathrm{m}$ and includes a photodiode acting as signal transducer. The LIP CIS was designed in a standard 0.18 ${\mu }$ $\mathrm{m}$ CMOS technology specifically for TRF applications. The LIP architecture blocks interfering light when fluorophores are excited and accumulates the emitted fluorescence light to be measured over multiple cycles after excitation. This allows to detect even small amounts of fluorescence light over a wide analyte concentration range. The LIP CIS based TRF reader was characterized in terms of reproducible and uniform signal intensities with use of appropriate Europium(III) [Eu 3+] chelate particles as fluorescence standards. We measured different concentrations of Eu-based nanoparticles (NP) on test strips with the TRF reader. The sensor system shows 5.1 orders of magnitude of detection dynamic range (DDR) with a limit of detection (LoD) of $0.1 \ \text{ng/cm}$ . In addition, using human C-reactive protein (hCRP) as a model analyte, we compared the developed TRF reader with a commercial colorimetric LFA reader. For the quantification of CRP, the LIP CIS based TRF reader demonstrates a DDR of 3.6 orders of magnitude with an excellent LoD of $0.05 \ \text{ng/mL}$ , which is 14 times better than the LoD of the commercial LFA reader.
- 21 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 16 (4) , 535-544
Open AccessLock-In Pixel CMOS Image Sensor for Time-Resolved Fluorescence Readout of Lateral-Flow Assays
We present a CMOS image sensor (CIS) based time-resolved fluorescence (TRF) measurement system for filter-less, highly sensitive readout of lateral-flow assay (LFA) test strips. The CIS contains a 256 × 128 lock-in pixel (LIP) sensor array. Each pixel has a size of $10 \ {\mu }\mathrm{m}$ × $10 \ {\mu }\mathrm{m}$ and includes a photodiode acting as signal transducer. The LIP CIS was designed in a standard 0.18 ${\mu }$ $\mathrm{m}$ CMOS technology specifically for TRF applications. The LIP architecture blocks interfering light when fluorophores are excited and accumulates the emitted fluorescence light to be measured over multiple cycles after excitation. This allows to detect even small amounts of fluorescence light over a wide analyte concentration range. The LIP CIS based TRF reader was characterized in terms of reproducible and uniform signal intensities with use of appropriate Europium(III) [Eu 3+] chelate particles as fluorescence standards. We measured different concentrations of Eu-based nanoparticles (NP) on test strips with the TRF reader. The sensor system shows 5.1 orders of magnitude of detection dynamic range (DDR) with a limit of detection (LoD) of $0.1 \ \text{ng/cm}$ . In addition, using human C-reactive protein (hCRP) as a model analyte, we compared the developed TRF reader with a commercial colorimetric LFA reader. For the quantification of CRP, the LIP CIS based TRF reader demonstrates a DDR of 3.6 orders of magnitude with an excellent LoD of $0.05 \ \text{ng/mL}$ , which is 14 times better than the LoD of the commercial LFA reader.
- 7 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Filterless TRF Reader with CMOS Sensor ASIC for Lateral Flow Immunoassays
In this paper, we present a filterless time-resolved fluorescence (TRF) measurement system with an optoelectronic CMOS sensor for highly sensitive readout of lateral flow assay (LFA) test strips. An application specific integrated circuit (ASIC) was designed in a standard 0.35-µm CMOS technology and includes a 5 × 5 CMOS sensor array. Each sensor pixel contains a 100 µm × 100 µm photodiode acting as signal transducer. For the precise control of the measurement sequence and its timing regime, a microcode engine (MCE) has been realized in a field-programmable gate array (FPGA). An active LED discharge concept was implemented to prevent long afterglow of the light source after it is turned off. To characterize the TRF reader with respect to uniform and reproducible signal intensities, suitable europium (III) [Eu 3+] chelate particles were used as fluorescence standards. Different concentrations of europium based nanoparticles (NP) on test strips were quantified with the TRF reader. Furthermore, we compared the developed TRF reader to a commercial colorimetric LFA reader system using human C-reactive protein (hCRP) as model analyte. The CMOS sensor ASIC based filterless TRF reader showed a detection dynamic range (DDR) of 4 orders of magnitude with a LoD of 0.2 ng/ml for the quantification of CRP, which was 3.5 times better than the LoD of the commercial LFA reader.
- 7 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Filterless TRF Reader with CMOS Sensor ASIC for Lateral Flow Immunoassays
In this paper, we present a filterless time-resolved fluorescence (TRF) measurement system with an optoelectronic CMOS sensor for highly sensitive readout of lateral flow assay (LFA) test strips. An application specific integrated circuit (ASIC) was designed in a standard 0.35-µm CMOS technology and includes a 5 × 5 CMOS sensor array. Each sensor pixel contains a 100 µm × 100 µm photodiode acting as signal transducer. For the precise control of the measurement sequence and its timing regime, a microcode engine (MCE) has been realized in a field-programmable gate array (FPGA). An active LED discharge concept was implemented to prevent long afterglow of the light source after it is turned off. To characterize the TRF reader with respect to uniform and reproducible signal intensities, suitable europium (III) [Eu 3+] chelate particles were used as fluorescence standards. Different concentrations of europium based nanoparticles (NP) on test strips were quantified with the TRF reader. Furthermore, we compared the developed TRF reader to a commercial colorimetric LFA reader system using human C-reactive protein (hCRP) as model analyte. The CMOS sensor ASIC based filterless TRF reader showed a detection dynamic range (DDR) of 4 orders of magnitude with a LoD of 0.2 ng/ml for the quantification of CRP, which was 3.5 times better than the LoD of the commercial LFA reader.
- 25 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 15 (3) , 369-379
Light Absorption Measurement With a CMOS Biochip for Quantitative Immunoassay Based Point-of-Care Applications
We present a CMOS biochip-based photometer for quantitative immunoassay diagnostics. The photometer quantifies the concentration of antigens based on light absorption, which allows for a low-cost implementation without expensive optical components. We propose a light controller to lower the start-up and settling time of the light source to 30 seconds, to facilitate fast measurement starts, and to decrease the overall measurement times. The application-specific integrated circuit (ASIC) contains a 6 x 7-sensor array with 100 $\boldsymbol{\mu }$ m x 100 $\boldsymbol{\mu }$ m photodiodes that serve as signal transducers. The ASIC was developed in a normal 0.35- $\boldsymbol{\mu }$ m CMOS technology, avoiding the need for expensive post-CMOS processes. We present our strategy for the assembly of the ASIC and the immobilization of antibodies. For its first time, we demonstrate the quantification of prostate specific antigen (PSA) with an optoelectronic CMOS biochip using this approach. A PSA immunoassay is performed on the top surface of the CMOS sensor array, enzyme kinetics and PSA concentration are measured within 6 minutes with a limit of detection (LoD) of 0.5 ng/ml, which meets clinical testing requirements. We achieve an overall coefficient of variation (CV) of 7%, which is good compared to other point-of-care (PoC) systems.
- 25 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 15 (3) , 369-379
Light Absorption Measurement With a CMOS Biochip for Quantitative Immunoassay Based Point-of-Care Applications
We present a CMOS biochip-based photometer for quantitative immunoassay diagnostics. The photometer quantifies the concentration of antigens based on light absorption, which allows for a low-cost implementation without expensive optical components. We propose a light controller to lower the start-up and settling time of the light source to 30 seconds, to facilitate fast measurement starts, and to decrease the overall measurement times. The application-specific integrated circuit (ASIC) contains a 6 x 7-sensor array with 100 $\boldsymbol{\mu }$ m x 100 $\boldsymbol{\mu }$ m photodiodes that serve as signal transducers. The ASIC was developed in a normal 0.35- $\boldsymbol{\mu }$ m CMOS technology, avoiding the need for expensive post-CMOS processes. We present our strategy for the assembly of the ASIC and the immobilization of antibodies. For its first time, we demonstrate the quantification of prostate specific antigen (PSA) with an optoelectronic CMOS biochip using this approach. A PSA immunoassay is performed on the top surface of the CMOS sensor array, enzyme kinetics and PSA concentration are measured within 6 minutes with a limit of detection (LoD) of 0.5 ng/ml, which meets clinical testing requirements. We achieve an overall coefficient of variation (CV) of 7%, which is good compared to other point-of-care (PoC) systems.
- 1 September 2020
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 164, 112324
Carboxyl functionalized gold nanorods for sensitive visual detection of biomolecules
- 1 September 2020
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 164, 112324
Carboxyl functionalized gold nanorods for sensitive visual detection of biomolecules
- 21 June 2016
- Published by Wiley in Macromolecular Chemistry and Physics
- Vol. 217 (16) , 1823-1833
Incorporation of Hydrophobic Dyes within Cellulose Acetate and Acetate Phthalate Based Nanoparticles
Polysaccharide based nanoparticles (NP) have demonstrated a unique potential for biomedical and biotechnological applications. Various functionalities can be covalently linked to these NP, however, physical entrapment of functional compounds is still a highly desired approach, e.g., for drug delivery. Using different dyes, it is demonstrated how hydrophobic compounds can be incorporated into composite particles derived from cellulosic esters and how the particle properties are affected by the composition. The dye loaded NP are studied by UV–vis spectroscopy to gain insight in the interaction of the hydrophobic compounds with the cellulosic matrix. By using functional cellulose derivatives, in particular carboxylate group bearing acetate phthalates, it is possible to introduce reactive moieties on the NP surface that can be exploited for coupling additional functionalities such as antibodies. By this approach, NP can be obtained that are well suited as dye labels in immunoassay applications. image
- 21 June 2016
- Published by Wiley in Macromolecular Chemistry and Physics
- Vol. 217 (16) , 1823-1833
Incorporation of Hydrophobic Dyes within Cellulose Acetate and Acetate Phthalate Based Nanoparticles
Polysaccharide based nanoparticles (NP) have demonstrated a unique potential for biomedical and biotechnological applications. Various functionalities can be covalently linked to these NP, however, physical entrapment of functional compounds is still a highly desired approach, e.g., for drug delivery. Using different dyes, it is demonstrated how hydrophobic compounds can be incorporated into composite particles derived from cellulosic esters and how the particle properties are affected by the composition. The dye loaded NP are studied by UV–vis spectroscopy to gain insight in the interaction of the hydrophobic compounds with the cellulosic matrix. By using functional cellulose derivatives, in particular carboxylate group bearing acetate phthalates, it is possible to introduce reactive moieties on the NP surface that can be exploited for coupling additional functionalities such as antibodies. By this approach, NP can be obtained that are well suited as dye labels in immunoassay applications. image