Lourdes Soler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lourdes Soler has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Adrián Marco
Zeulab S.L., Calle Bari 25 dpdo, 50197, Zaragoza, Spain
1 shared publication - Alejandra Antón
Zeulab S.L., Calle Bari 25 dpdo, 50197, Zaragoza, Spain
1 shared publication - David Sanz
Zeulab S.L., Calle Bari 25 dpdo, 50197, Zaragoza, Spain
1 shared publication - Kinga Domrazek
Small Animal Reproduction Laboratory, Department of Small Animal Diseases with Clinic, Institute of Veterinary Medicine, Warsaw University of Life Science, Nowoursynowska 159, 02-776 Warsaw, Poland
1 shared publication - Luis Mata
Zeulab S.L. , Calle Bari 25 Dpdo , 50197 Zaragoza
1 shared publication - Magdalena Krzeszewska Zachary
Department of Pathology and Veterinary Diagnostics, Institute of Veterinary Medicine, Warsaw University of Life Sciences , Warsaw , Poland
1 shared publication
Latest Publications
- Open Access
- 1 March 2026
- Published by Walter de Gruyter GmbH in Journal of Veterinary Research
- Vol. 70 (1) , 129-137
Selected inflammatory markers in uterine and peripheral blood of bitches with pyometra
Introduction: Pyometra is a common and potentially life-threatening uterine infection in bitches, with severe local and systemic inflammation as symptoms. Studies exist on inflammatory markers in peripheral blood (PB), but little is known about their expression in uterine blood (UB). This study aimed to compare their concentrations simultaneously in UB and PB of bitches with pyometra, and to evaluate their diagnostic and prognostic potential. Material and Methods: Twenty-two bitches with confirmed pyometra (13 closed-cervix and 9 open-cervix cases) and six healthy controls were enrolled. Blood samples were collected from the cephalic and uterine veins during ovariohysterectomy. The concentrations of IL-1α, IL-1β, IL-6 and IL-10 were measured using an ELISA validated for dogs, and C-reactive protein (CRP) was measured by an immunoturbidimetric assay. These five inflammatory markers were compared statistically between the three groups of dogs and two types of blood sample using the Mann–Whitney U and Wilcoxon tests. Results: All markers were significantly elevated in affected bitches’ UB and PB. The IL-6 concentrations were significantly higher in UB than in PB, suggesting local production of this cytokine. Conversely, the IL-10 levels were higher in PB, possibly reflecting a systemic regulatory response. The concentrations of IL-1α and IL-1β differed insignificantly from each other. Those of CRP were significantly higher in open-cervix than in closed-cervix pyometra, indicating a stronger acute-phase response. Conclusion: The results assign IL-6 and CRP a potential role as biomarkers for the diagnosis and prognosis of pyometra. Simultaneous analysis of uterine and systemic inflammatory responses provides insight into the disease’s pathophysiology and may support more targeted therapeutic approaches.
- 1 March 2026
- Published by Walter de Gruyter GmbH in Journal of Veterinary Research
- Vol. 70 (1) , 129-137
Open AccessSelected inflammatory markers in uterine and peripheral blood of bitches with pyometra
Introduction: Pyometra is a common and potentially life-threatening uterine infection in bitches, with severe local and systemic inflammation as symptoms. Studies exist on inflammatory markers in peripheral blood (PB), but little is known about their expression in uterine blood (UB). This study aimed to compare their concentrations simultaneously in UB and PB of bitches with pyometra, and to evaluate their diagnostic and prognostic potential. Material and Methods: Twenty-two bitches with confirmed pyometra (13 closed-cervix and 9 open-cervix cases) and six healthy controls were enrolled. Blood samples were collected from the cephalic and uterine veins during ovariohysterectomy. The concentrations of IL-1α, IL-1β, IL-6 and IL-10 were measured using an ELISA validated for dogs, and C-reactive protein (CRP) was measured by an immunoturbidimetric assay. These five inflammatory markers were compared statistically between the three groups of dogs and two types of blood sample using the Mann–Whitney U and Wilcoxon tests. Results: All markers were significantly elevated in affected bitches’ UB and PB. The IL-6 concentrations were significantly higher in UB than in PB, suggesting local production of this cytokine. Conversely, the IL-10 levels were higher in PB, possibly reflecting a systemic regulatory response. The concentrations of IL-1α and IL-1β differed insignificantly from each other. Those of CRP were significantly higher in open-cervix than in closed-cervix pyometra, indicating a stronger acute-phase response. Conclusion: The results assign IL-6 and CRP a potential role as biomarkers for the diagnosis and prognosis of pyometra. Simultaneous analysis of uterine and systemic inflammatory responses provides insight into the disease’s pathophysiology and may support more targeted therapeutic approaches.
- 28 April 2021
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 104 (5) , 1289-1297
Validation of the Eclipse Farm 4G & COMET for Detection of Antibiotics in Raw Bovine Milk: AOAC Performance Tested MethodSM 022101
The Eclipse Farm 4G test coupled to the COMET device allows for automatic and easy screening of a broad range of antimicrobials in raw bovine milk. All results obtained with this system are available in real-time through a smartphone application (App) and in the Test4all cloud platform. The objective of this study was to validate Eclipse Farm 4G & COMET for the screening of antimicrobials in raw bovine milk according to AOAC Performance Tested MethodSM procedures. The test is based on the inhibition of microbial growth of Geobacillus stearothermophilus in the presence of antimicrobials. When sample tubes are incubated in the absence of antibiotics, spores germinate and cells grow, changing the medium color from purple to yellow (negative result). The presence of antimicrobials in the milk sample hinders bacterial growth, preventing the tubes from changing color from purple to yellow (positive result). The COMET device automatically integrates all assay steps (incubation, time control, and results interpretation) and communications between the device, smartphone, and cloud. LODs and detection capabilities were confirmed to be at or below the European Union (EU) maximum residue limit (MRL) for most of the evaluated molecules representing the main families of antimicrobials (penicillins, cephalosporins, tetracyclines, sulfonamides, macrolides, and aminoglycosides). False-positive rates and the effect of potentially interfering substances showed sufficient selectivity/specificity. The Eclipse Farm 4G & COMET system was shown to be robust, consistent, and stable during shelf life. The Eclipse Farm 4G & COMET system has been shown to be suitable for screening antibiotics in raw bovine milk. The assay is an automatic and easy system for the detection of a broad range of antibiotics in raw bovine milk consistent with EU MRLs and can provide results any time and anywhere through a smartphone App and a cloud platform.
- 28 April 2021
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 104 (5) , 1289-1297
Validation of the Eclipse Farm 4G & COMET for Detection of Antibiotics in Raw Bovine Milk: AOAC Performance Tested MethodSM 022101
The Eclipse Farm 4G test coupled to the COMET device allows for automatic and easy screening of a broad range of antimicrobials in raw bovine milk. All results obtained with this system are available in real-time through a smartphone application (App) and in the Test4all cloud platform. The objective of this study was to validate Eclipse Farm 4G & COMET for the screening of antimicrobials in raw bovine milk according to AOAC Performance Tested MethodSM procedures. The test is based on the inhibition of microbial growth of Geobacillus stearothermophilus in the presence of antimicrobials. When sample tubes are incubated in the absence of antibiotics, spores germinate and cells grow, changing the medium color from purple to yellow (negative result). The presence of antimicrobials in the milk sample hinders bacterial growth, preventing the tubes from changing color from purple to yellow (positive result). The COMET device automatically integrates all assay steps (incubation, time control, and results interpretation) and communications between the device, smartphone, and cloud. LODs and detection capabilities were confirmed to be at or below the European Union (EU) maximum residue limit (MRL) for most of the evaluated molecules representing the main families of antimicrobials (penicillins, cephalosporins, tetracyclines, sulfonamides, macrolides, and aminoglycosides). False-positive rates and the effect of potentially interfering substances showed sufficient selectivity/specificity. The Eclipse Farm 4G & COMET system was shown to be robust, consistent, and stable during shelf life. The Eclipse Farm 4G & COMET system has been shown to be suitable for screening antibiotics in raw bovine milk. The assay is an automatic and easy system for the detection of a broad range of antibiotics in raw bovine milk consistent with EU MRLs and can provide results any time and anywhere through a smartphone App and a cloud platform.