Alejandra Antón
Research Subjects
Research Interests
Alejandra Antón has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Adrián Marco
Zeulab S.L., Calle Bari 25 dpdo, 50197, Zaragoza, Spain
1 shared publication - David Sanz
Zeulab S.L., Calle Bari 25 dpdo, 50197, Zaragoza, Spain
1 shared publication - Lourdes Soler
Department de Bioquímica y Biología Molecular y Celular, Facultad de Ciencias, Universidad de Zaragoza , Zaragoza , Spain
1 shared publication - Luis Mata
Zeulab S.L. , Calle Bari 25 Dpdo , 50197 Zaragoza
1 shared publication - Pedro Razquin
Zeulab S.L. , Calle Bari 25 Dpdo , 50197 Zaragoza
1 shared publication - Sofía Andaluz
Zeulab S.L., Calle Bari 25 dpdo, 50197, Zaragoza, Spain
1 shared publication
Latest Publications
- 28 April 2021
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 104 (5) , 1289-1297
Validation of the Eclipse Farm 4G & COMET for Detection of Antibiotics in Raw Bovine Milk: AOAC Performance Tested MethodSM 022101
The Eclipse Farm 4G test coupled to the COMET device allows for automatic and easy screening of a broad range of antimicrobials in raw bovine milk. All results obtained with this system are available in real-time through a smartphone application (App) and in the Test4all cloud platform. The objective of this study was to validate Eclipse Farm 4G & COMET for the screening of antimicrobials in raw bovine milk according to AOAC Performance Tested MethodSM procedures. The test is based on the inhibition of microbial growth of Geobacillus stearothermophilus in the presence of antimicrobials. When sample tubes are incubated in the absence of antibiotics, spores germinate and cells grow, changing the medium color from purple to yellow (negative result). The presence of antimicrobials in the milk sample hinders bacterial growth, preventing the tubes from changing color from purple to yellow (positive result). The COMET device automatically integrates all assay steps (incubation, time control, and results interpretation) and communications between the device, smartphone, and cloud. LODs and detection capabilities were confirmed to be at or below the European Union (EU) maximum residue limit (MRL) for most of the evaluated molecules representing the main families of antimicrobials (penicillins, cephalosporins, tetracyclines, sulfonamides, macrolides, and aminoglycosides). False-positive rates and the effect of potentially interfering substances showed sufficient selectivity/specificity. The Eclipse Farm 4G & COMET system was shown to be robust, consistent, and stable during shelf life. The Eclipse Farm 4G & COMET system has been shown to be suitable for screening antibiotics in raw bovine milk. The assay is an automatic and easy system for the detection of a broad range of antibiotics in raw bovine milk consistent with EU MRLs and can provide results any time and anywhere through a smartphone App and a cloud platform.
- 28 April 2021
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 104 (5) , 1289-1297
Validation of the Eclipse Farm 4G & COMET for Detection of Antibiotics in Raw Bovine Milk: AOAC Performance Tested MethodSM 022101
The Eclipse Farm 4G test coupled to the COMET device allows for automatic and easy screening of a broad range of antimicrobials in raw bovine milk. All results obtained with this system are available in real-time through a smartphone application (App) and in the Test4all cloud platform. The objective of this study was to validate Eclipse Farm 4G & COMET for the screening of antimicrobials in raw bovine milk according to AOAC Performance Tested MethodSM procedures. The test is based on the inhibition of microbial growth of Geobacillus stearothermophilus in the presence of antimicrobials. When sample tubes are incubated in the absence of antibiotics, spores germinate and cells grow, changing the medium color from purple to yellow (negative result). The presence of antimicrobials in the milk sample hinders bacterial growth, preventing the tubes from changing color from purple to yellow (positive result). The COMET device automatically integrates all assay steps (incubation, time control, and results interpretation) and communications between the device, smartphone, and cloud. LODs and detection capabilities were confirmed to be at or below the European Union (EU) maximum residue limit (MRL) for most of the evaluated molecules representing the main families of antimicrobials (penicillins, cephalosporins, tetracyclines, sulfonamides, macrolides, and aminoglycosides). False-positive rates and the effect of potentially interfering substances showed sufficient selectivity/specificity. The Eclipse Farm 4G & COMET system was shown to be robust, consistent, and stable during shelf life. The Eclipse Farm 4G & COMET system has been shown to be suitable for screening antibiotics in raw bovine milk. The assay is an automatic and easy system for the detection of a broad range of antibiotics in raw bovine milk consistent with EU MRLs and can provide results any time and anywhere through a smartphone App and a cloud platform.