Yi Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yi Zhao has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Liling Wang
School of Physics and Electronic Engineering, Chongqing Normal University, Chongqing, China
1 shared publication - Pan Guo
School of Physics and Electronic Engineering, Chongqing Normal University, Chongqing, China
1 shared publication - Rui Wang
School of Physics and Electronic Engineering, Chongqing Normal University, Chongqing, China
1 shared publication - Wei He
Chongqing University
1 shared publication - Xiaohu Liu
Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
1 shared publication - Yi Guo
Chinese Academy of Sciences, China
1 shared publication
Latest Publications
- 18 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Miniaturized Broadband Antenna Loaded With Frequency Selective Surface for Corona Discharge Detection
Corona discharge is a common phenomenon on high-voltage transmission lines that can lead to insulation damage and power loss. Antenna detection is one of the current standard detection methods, but it suffers from limited sensitivity. To address this issue, this paper proposes a frequency selective surface (FSS) array operating in the corona discharge frequency band. The FSS array has 15×15 identical cells. Each cell consists of two metal patches. The upper patch is constructed of a twisted cross-shaped cell, while the bottom patch is constructed of a cross cell with patch inductive components. The cell's dimensions are 10 mm × 10 mm × 1.6 mm, with S11 < -10 dB in the corona discharge frequency band. We superimpose the array onto the antenna and use ANSYS HFSS module to simulate how the distance between the antenna and the array affects antenna performance. The results suggest that the optimum antenna performance occurs when the distance is 20 mm. Corona discharge experiments revealed that the amplitude of signals detected by FSS loaded on the detection antenna is 128%, 130%, 132% and 135% higher than the original antenna at detection ranges of 1 m, 4m, 7 m, and 10 m, respectively. Moreover, the antenna achieves the farthest detection distance of 13 m.
- 18 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Miniaturized Broadband Antenna Loaded With Frequency Selective Surface for Corona Discharge Detection
Corona discharge is a common phenomenon on high-voltage transmission lines that can lead to insulation damage and power loss. Antenna detection is one of the current standard detection methods, but it suffers from limited sensitivity. To address this issue, this paper proposes a frequency selective surface (FSS) array operating in the corona discharge frequency band. The FSS array has 15×15 identical cells. Each cell consists of two metal patches. The upper patch is constructed of a twisted cross-shaped cell, while the bottom patch is constructed of a cross cell with patch inductive components. The cell's dimensions are 10 mm × 10 mm × 1.6 mm, with S11 < -10 dB in the corona discharge frequency band. We superimpose the array onto the antenna and use ANSYS HFSS module to simulate how the distance between the antenna and the array affects antenna performance. The results suggest that the optimum antenna performance occurs when the distance is 20 mm. Corona discharge experiments revealed that the amplitude of signals detected by FSS loaded on the detection antenna is 128%, 130%, 132% and 135% higher than the original antenna at detection ranges of 1 m, 4m, 7 m, and 10 m, respectively. Moreover, the antenna achieves the farthest detection distance of 13 m.
- 10 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-14
Nonintrusive Current Sensing for Multicore Cables Considering Inclination With Magnetic Field Measurement
Magnetic sensor arrays have been employed to measure currents for multicore cables due to their advantages of compact size, lightweight, low power consumption, and large dynamic range. However, the existing methods are applicable only to cases where the cable must be perpendicular to the sensor array plane due to the lack of capability of the 2-D magnetic field model to consider conductor inclination. To solve this problem, this article presents a method using a circular array of single-axis magnetic sensors to measure magnetic fields along and perpendicular to the sensor array plane. A 3-D magnetic field model that involves conductor incline angles is first derived. On the basis of the derived model, two main steps are performed to realize current sensing. First, an off-site calibration method is used to calibrate magnetic sensor parameters, including sensor position, orientation, gain factor, and phase shift. Second, not only the conductor currents and positions but also the incline angles are simultaneously calculated based on the detected magnetic fields and calibrated sensor parameters. Both steps are formulated as nonlinear least-square problems and solved efficiently. Both simulation and experiment are performed to demonstrate the superiority of the proposed method compared to the existing ones based on the 2-D magnetic field model when inclinations are introduced. The proposed method may have the potential for designing a clamp-on current sensor dedicated to multicore cables similar to hand-held current probes with a relatively large inner diameter for single-conductor systems.
- 10 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-14
Nonintrusive Current Sensing for Multicore Cables Considering Inclination With Magnetic Field Measurement
Magnetic sensor arrays have been employed to measure currents for multicore cables due to their advantages of compact size, lightweight, low power consumption, and large dynamic range. However, the existing methods are applicable only to cases where the cable must be perpendicular to the sensor array plane due to the lack of capability of the 2-D magnetic field model to consider conductor inclination. To solve this problem, this article presents a method using a circular array of single-axis magnetic sensors to measure magnetic fields along and perpendicular to the sensor array plane. A 3-D magnetic field model that involves conductor incline angles is first derived. On the basis of the derived model, two main steps are performed to realize current sensing. First, an off-site calibration method is used to calibrate magnetic sensor parameters, including sensor position, orientation, gain factor, and phase shift. Second, not only the conductor currents and positions but also the incline angles are simultaneously calculated based on the detected magnetic fields and calibrated sensor parameters. Both steps are formulated as nonlinear least-square problems and solved efficiently. Both simulation and experiment are performed to demonstrate the superiority of the proposed method compared to the existing ones based on the 2-D magnetic field model when inclinations are introduced. The proposed method may have the potential for designing a clamp-on current sensor dedicated to multicore cables similar to hand-held current probes with a relatively large inner diameter for single-conductor systems.