LWLiling Wang

Liling Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Liling Wang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Novel Hilbert Antenna Enhanced With Metamaterials for Partial Discharge Detection

    by Rui Wang, Liling Wang, Haoyue Luo, Yibing Wang, Pan Guo

    Partial discharge detection is critical for the maintenance and safety of high-voltage equipment. However, conventional UHF antennas suffer from limitations like excessive physical size and narrow bandwidth. This study proposes a novel Hilbert fractal curve-modified spiral antenna design to expand bandwidth without increasing the antenna’s physical dimensions. Furthermore, a symmetric open double-ring metamaterial structure is introduced to further improve the antenna’s performance. Fabricated as an 8×8 array and placed 10 mm above the Hilbert spiral antenna, this metamaterial structure significantly enhances the antenna’s gain, detection bandwidth, and directionality. Both simulation and experimental results demonstrate that the Hilbert spiral antenna integrated with the metamaterial achieves a voltage standing wave ratio (VSWR) < 2 over two wide frequency bands: 0.78–2.02 GHz and 2.22–3 GHz. This configuration delivers a 24.4% increase in operational bandwidth, a 4.61 dBi improvement in average gain, and enhanced directivity and radiation performance. This study used a partial discharge simulation platform to validate the antenna’s performance. Experimental results indicate that, at distances of 2-8 m, the metamaterial-integrated antenna exhibits 125% higher detection sensitivity than the antenna without metamaterials. Moreover, the detection range of antenna with metamaterials is expanded to 10 m.


  • Miniaturized Broadband Antenna Loaded With Frequency Selective Surface for Corona Discharge Detection

    by Pan Guo, Rui Wang, Liling Wang, Yi Zhao

    Corona discharge is a common phenomenon on high-voltage transmission lines that can lead to insulation damage and power loss. Antenna detection is one of the current standard detection methods, but it suffers from limited sensitivity. To address this issue, this paper proposes a frequency selective surface (FSS) array operating in the corona discharge frequency band. The FSS array has 15×15 identical cells. Each cell consists of two metal patches. The upper patch is constructed of a twisted cross-shaped cell, while the bottom patch is constructed of a cross cell with patch inductive components. The cell's dimensions are 10 mm × 10 mm × 1.6 mm, with S11 < -10 dB in the corona discharge frequency band. We superimpose the array onto the antenna and use ANSYS HFSS module to simulate how the distance between the antenna and the array affects antenna performance. The results suggest that the optimum antenna performance occurs when the distance is 20 mm. Corona discharge experiments revealed that the amplitude of signals detected by FSS loaded on the detection antenna is 128%, 130%, 132% and 135% higher than the original antenna at detection ranges of 1 m, 4m, 7 m, and 10 m, respectively. Moreover, the antenna achieves the farthest detection distance of 13 m.