Miroslav Polášek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Miroslav Polášek has a total of 110 co-authors. Here are the top co-authors by number of shared publications:
- Ján Žabka
Heyrovský Institute of the Czech Academy of Sciences
8 shared publications - Daniela Ascenzi
Dipartimento di Fisica, Università di Trento, 38123 Povo, Italy
7 shared publications - Christian Alcaraz
Université Paris-Saclay, CNRS, Institut de chimie physique, UMR8000, 91405 Orsay, France
5 shared publications Claire Romanzin
Université Paris-Saclay, CNRS, Institut de Chimie Physique, UMR8000 2 , 91405 Orsay
5 shared publications- Vincent Richardson
Department of Physics, University of Liverpool 1 , Liverpool L69 7ZE
5 shared publications - Roland Thissen
Université Paris-Saclay, CNRS, Institut de chimie physique, UMR8000, 91405 Orsay, France
4 shared publications
Latest Publications
- Open Access
- 22 September 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Hypervelocity impact mass spectrometry enables membrane phospholipid detection in ocean-world plumes
Saturn's ocean moon Enceladus and Jupiter's moon Europa expel subsurface material into space, enabling direct sampling of potentially habitable ocean environments without landing on their surfaces. Previous spacecraft analyses of plume ice grains revealed salts, simple organic compounds, and degraded macromolecular material, but no unambiguous molecular biosignatures. A fundamental question is whether diagnostic components of living cells can survive hypervelocity impact ionization during spacecraft flyby sampling. Here, we demonstrate that phospholipid membranes produce distinct and diagnostic negative-ion signatures following hypervelocity impacts of nanometer-sized ice particles at velocities up to 3.7 km s⁻¹. Using artificial vesicles composed of the phospholipid 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC), we obtained single-particle time-of-flight mass spectra containing characteristic phosphate-derived and fatty-acid fragment ions together with higher-mass species. Assignments were supported by collision-induced dissociation measurements using high-resolution Orbitrap mass spectrometry. The persistence of these membrane-specific anions demonstrates that hypervelocity impact ionization preserves molecular signatures diagnostic of phospholipid bilayers, identifying cell membranes or their components as a detectable class of biosignatures for plume-sampling missions. Our results provide an experimental framework for interpreting complex negative-ion spectra from future ocean-world missions, including Europa Clipper and proposed Enceladus missions, and highlight the scientific value of high-resolution negative-ion impact mass spectrometry for the search for extraterrestrial life.
- 22 September 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessHypervelocity impact mass spectrometry enables membrane phospholipid detection in ocean-world plumes
Saturn's ocean moon Enceladus and Jupiter's moon Europa expel subsurface material into space, enabling direct sampling of potentially habitable ocean environments without landing on their surfaces. Previous spacecraft analyses of plume ice grains revealed salts, simple organic compounds, and degraded macromolecular material, but no unambiguous molecular biosignatures. A fundamental question is whether diagnostic components of living cells can survive hypervelocity impact ionization during spacecraft flyby sampling. Here, we demonstrate that phospholipid membranes produce distinct and diagnostic negative-ion signatures following hypervelocity impacts of nanometer-sized ice particles at velocities up to 3.7 km s⁻¹. Using artificial vesicles composed of the phospholipid 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC), we obtained single-particle time-of-flight mass spectra containing characteristic phosphate-derived and fatty-acid fragment ions together with higher-mass species. Assignments were supported by collision-induced dissociation measurements using high-resolution Orbitrap mass spectrometry. The persistence of these membrane-specific anions demonstrates that hypervelocity impact ionization preserves molecular signatures diagnostic of phospholipid bilayers, identifying cell membranes or their components as a detectable class of biosignatures for plume-sampling missions. Our results provide an experimental framework for interpreting complex negative-ion spectra from future ocean-world missions, including Europa Clipper and proposed Enceladus missions, and highlight the scientific value of high-resolution negative-ion impact mass spectrometry for the search for extraterrestrial life.
- Open Access
- 28 June 2026
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 40 (18) , e70130
Effect of Humidity on Ionisation and Ion Chemistry in Active‐Capillary Dielectric Barrier Discharge Ionisation
Rationale: Dielectric barrier discharge ionisation (DBDI) in an active‐capillary configuration (including the commercial SICRIT source) is widely used as a soft, ambient‐pressure ionisation method for vapours and gases, yet the role of water vapour in controlling reagent ion chemistry and analytical behaviour has not been mechanistically described. Thus, it is necessary to understand how carrier gas humidity governs reagent ion populations and product ion formation in a DBDI source. Methods: A SICRIT ion source was coupled to a triple‐quadrupole mass spectrometer and operated under constant discharge conditions while switching the carrier gas between humidified and nominally dry air. Ketones and short‐chain carboxylic acids were introduced at trace vapour concentrations using permeation or diffusion tubes. Reagent ion and analyte mass spectra were acquired in full‐scan mode. Selected analyte ions were subjected to collision‐induced dissociation (CID) to compare in‐source fragments with those formed from protonated molecules. Results: Under humid conditions, the reagent ion population was dominated by hydrated hydronium ions. Analytes yielded mainly protonated molecules, MH + and their hydrates, with minimal fragmentation. Switching to a dry carrier gas reduced the total ion current by more than an order of magnitude and led to extensive, structure‐dependent fragmentation. Comparison with CID spectra of MH + indicates that the fragments observed under dry conditions arise from the fragmentation of protonated molecules rather than from the direct dissociation of radical cations. This is explained by highly exothermic proton transfer from a dominant m/z 29 reagent ion (most plausibly N 2 H + ). Conclusions: These results highlight humidity as a key operational active‐capillary DBDI parameter; varying it enables both low‐fragmentation ionisation in humid mode and more energetic fragmenting ionisation in dry mode. The humid mode facilitates reproducible quantitation, whereas the dry mode allows structural discrimination, exemplified by differentiation of hexanone isomers.
- 28 June 2026
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 40 (18) , e70130
Open AccessEffect of Humidity on Ionisation and Ion Chemistry in Active‐Capillary Dielectric Barrier Discharge Ionisation
Rationale: Dielectric barrier discharge ionisation (DBDI) in an active‐capillary configuration (including the commercial SICRIT source) is widely used as a soft, ambient‐pressure ionisation method for vapours and gases, yet the role of water vapour in controlling reagent ion chemistry and analytical behaviour has not been mechanistically described. Thus, it is necessary to understand how carrier gas humidity governs reagent ion populations and product ion formation in a DBDI source. Methods: A SICRIT ion source was coupled to a triple‐quadrupole mass spectrometer and operated under constant discharge conditions while switching the carrier gas between humidified and nominally dry air. Ketones and short‐chain carboxylic acids were introduced at trace vapour concentrations using permeation or diffusion tubes. Reagent ion and analyte mass spectra were acquired in full‐scan mode. Selected analyte ions were subjected to collision‐induced dissociation (CID) to compare in‐source fragments with those formed from protonated molecules. Results: Under humid conditions, the reagent ion population was dominated by hydrated hydronium ions. Analytes yielded mainly protonated molecules, MH + and their hydrates, with minimal fragmentation. Switching to a dry carrier gas reduced the total ion current by more than an order of magnitude and led to extensive, structure‐dependent fragmentation. Comparison with CID spectra of MH + indicates that the fragments observed under dry conditions arise from the fragmentation of protonated molecules rather than from the direct dissociation of radical cations. This is explained by highly exothermic proton transfer from a dominant m/z 29 reagent ion (most plausibly N 2 H + ). Conclusions: These results highlight humidity as a key operational active‐capillary DBDI parameter; varying it enables both low‐fragmentation ionisation in humid mode and more energetic fragmenting ionisation in dry mode. The humid mode facilitates reproducible quantitation, whereas the dry mode allows structural discrimination, exemplified by differentiation of hexanone isomers.
- Open Access
- 15 June 2026
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 164 (23)
Experimental absolute cross sections for the reaction of isobutane [CH(CH3)3] with [CH2O]•+ isomers
Isomers frequently exhibit different physical and chemical properties, which can make accurate modeling of their reactivity highly challenging but can also be exploited as a method for isomer identification. In both cases, this requires accurate experimental data recorded at an isomer-specific level. The reactions of the DCOH•+ and H2CO•+ ions with isobutane [CH(CH3)3] are investigated experimentally in the 0.07–10 eV collision energy range using a guided-ion beam tandem mass spectrometer coupled to a tunable vacuum ultraviolet source. The reaction of the DCOH•+ ion is dominated by dissociative proton transfer processes, while the reactivity of H2CO•+ is predominantly driven by dissociative charge transfer processes. The kinematics are also significantly different, with the overall reactivity of the DCOH•+ isomer following an approximately Langevin trend, while the reactivity of H2CO•+ is distinctly non-Langevin. In addition, for the H2CO•+ isomer, sharp changes in reactivity are observed at photon energies corresponding to Rydberg autoionization, leading to vibrational excitation of the C–O stretching mode. The findings highlight the inadequacy of modeling molecular ions as point charges and evidence the need for isomer-specific reactivity data.
- 15 June 2026
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 164 (23)
Open AccessExperimental absolute cross sections for the reaction of isobutane [CH(CH3)3] with [CH2O]•+ isomers
Isomers frequently exhibit different physical and chemical properties, which can make accurate modeling of their reactivity highly challenging but can also be exploited as a method for isomer identification. In both cases, this requires accurate experimental data recorded at an isomer-specific level. The reactions of the DCOH•+ and H2CO•+ ions with isobutane [CH(CH3)3] are investigated experimentally in the 0.07–10 eV collision energy range using a guided-ion beam tandem mass spectrometer coupled to a tunable vacuum ultraviolet source. The reaction of the DCOH•+ ion is dominated by dissociative proton transfer processes, while the reactivity of H2CO•+ is predominantly driven by dissociative charge transfer processes. The kinematics are also significantly different, with the overall reactivity of the DCOH•+ isomer following an approximately Langevin trend, while the reactivity of H2CO•+ is distinctly non-Langevin. In addition, for the H2CO•+ isomer, sharp changes in reactivity are observed at photon energies corresponding to Rydberg autoionization, leading to vibrational excitation of the C–O stretching mode. The findings highlight the inadequacy of modeling molecular ions as point charges and evidence the need for isomer-specific reactivity data.
- Open Access
- 10 February 2026
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 61 (3) , e70033
Selected Ion Flow‐Tube Mass Spectrometry (SIFT‐MS) of Mo(CO) 6 and W(CO) 6 Vapours With Positive and Negative Reagent Ions
Selected ion flow‐tube mass spectrometry (SIFT‐MS) was used to characterise the gas‐phase ion–molecule reactions of the eight standard reagent ions H 3 O + , NO + , O 2 + ˙, OH − , O − ˙, O 2 − ˙, NO 2 − and NO 3 − with molybdenum and tungsten hexacarbonyls, Mo(CO) 6 and W(CO) 6 . These compounds, chosen as model volatile transition‐metal carbonyls, were introduced directly into the SIFT at variable concentrations, and mass spectra were obtained for all reagent ions. Reactions with the positive reagent ions were fast and close to the collisional limit, proceeding mainly by proton transfer (H 3 O + ) or charge transfer (NO + and O 2 + ˙) with little fragmentation. In contrast, negative‐ion reactions were slower and chemically more diverse. O − ˙ and O 2 − ˙ produced sequential oxidation and ligand‐exchange products, MoO x (CO) 6− n − ˙ and WO x (CO) 6− n − ˙, while NO 2 − reacted slowly only with Mo(CO) 6 . Relative rate coefficients normalised to H 3 O + proton transfer were determined. The results establish the feasibility of SIFT‐MS for direct, real‐time detection of transition‐metal carbonyl vapours and clarify their underlying ion–molecule chemistry. Positive‐ion channels offer the most sensitive analytical response, whereas negative‐ion reactions reveal complementary oxidative pathways. This study thus extends SIFT‐MS to a new class of metal–ligand compounds, which are relevant to environmental and occupational monitoring.
- 10 February 2026
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 61 (3) , e70033
Open AccessSelected Ion Flow‐Tube Mass Spectrometry (SIFT‐MS) of Mo(CO) 6 and W(CO) 6 Vapours With Positive and Negative Reagent Ions
Selected ion flow‐tube mass spectrometry (SIFT‐MS) was used to characterise the gas‐phase ion–molecule reactions of the eight standard reagent ions H 3 O + , NO + , O 2 + ˙, OH − , O − ˙, O 2 − ˙, NO 2 − and NO 3 − with molybdenum and tungsten hexacarbonyls, Mo(CO) 6 and W(CO) 6 . These compounds, chosen as model volatile transition‐metal carbonyls, were introduced directly into the SIFT at variable concentrations, and mass spectra were obtained for all reagent ions. Reactions with the positive reagent ions were fast and close to the collisional limit, proceeding mainly by proton transfer (H 3 O + ) or charge transfer (NO + and O 2 + ˙) with little fragmentation. In contrast, negative‐ion reactions were slower and chemically more diverse. O − ˙ and O 2 − ˙ produced sequential oxidation and ligand‐exchange products, MoO x (CO) 6− n − ˙ and WO x (CO) 6− n − ˙, while NO 2 − reacted slowly only with Mo(CO) 6 . Relative rate coefficients normalised to H 3 O + proton transfer were determined. The results establish the feasibility of SIFT‐MS for direct, real‐time detection of transition‐metal carbonyl vapours and clarify their underlying ion–molecule chemistry. Positive‐ion channels offer the most sensitive analytical response, whereas negative‐ion reactions reveal complementary oxidative pathways. This study thus extends SIFT‐MS to a new class of metal–ligand compounds, which are relevant to environmental and occupational monitoring.
- Open Access
- 5 February 2026
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 28 (10) , 6377-6387
The absolute cross-section of the reactive collision of P + ( 3 P) with D 2 : a combined theoretical and experimental study
VUV dissociative photoionization produces P + ( 3 P) ions. Absolute reactive cross sections with D 2 are measured at varying collision energy. Reaction dynamic calculations on three potential energy surfaces are performed to compute cross-sections.
- 5 February 2026
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 28 (10) , 6377-6387
Open AccessThe absolute cross-section of the reactive collision of P + ( 3 P) with D 2 : a combined theoretical and experimental study
VUV dissociative photoionization produces P + ( 3 P) ions. Absolute reactive cross sections with D 2 are measured at varying collision energy. Reaction dynamic calculations on three potential energy surfaces are performed to compute cross-sections.
- Open Access
- 6 January 2026
- Published by American Chemical Society (ACS) in ACS Earth and Space Chemistry
- Vol. 10 (1) , 148-156
IR-Action Spectroscopy of the Astrochemically Relevant HCCS + Cation
The thioketenyl cation (HCCS+) has been recently detected in the dark cloud TMC-1 by radioastronomical observations within the QUIJOTE survey. However, the infrared (IR) spectrum of this ion is yet to be reported in the literature. Spectroscopic reference data are essential for the search of HCCS+ using the James Webb Space Telescope, not only in molecular clouds and star-forming regions, but also in the ionospheres and upper atmospheres of exoplanets. In this work, we demonstrate a method for the selective generation of the HCCS+ ion in its triplet ground state (3Σ–) and use this method to obtain IR band positions for HCCS+. The IR-action spectrum of H2-tagged HCCS+ has been measured in a cryogenic 22-pole ion trap via IR photodissociation (IR-PD) spectroscopy with the FELIX light source in the wavenumber regions 450–1850 and 3000–3350 cm–1. Spectral information is complemented by theoretical calculations on the fragmentation mechanisms leading to the formation of HCCS+ from dissociative ionization of 2,5-dibromothiophene. The assignment of the experimental HCCS+ vibrational bands is aided by comparison with ab initio computed values from literature and from calculations at the UB3LYP/cc-pVQZ level of theory, for both the triplet (3Σ–) and singlet (1Σ+) states of HCCS+. The experimental HCCS+ spectra show an overall good agreement with the scaled theoretical values (to account for anharmonicity effects), facilitating assignment of the IR spectral features. These findings will enable new reactivity investigations and spectroscopic measurements to be conducted, and for HCCS+ to be included in astrochemical models and databases.
- 6 January 2026
- Published by American Chemical Society (ACS) in ACS Earth and Space Chemistry
- Vol. 10 (1) , 148-156
Open AccessIR-Action Spectroscopy of the Astrochemically Relevant HCCS + Cation
The thioketenyl cation (HCCS+) has been recently detected in the dark cloud TMC-1 by radioastronomical observations within the QUIJOTE survey. However, the infrared (IR) spectrum of this ion is yet to be reported in the literature. Spectroscopic reference data are essential for the search of HCCS+ using the James Webb Space Telescope, not only in molecular clouds and star-forming regions, but also in the ionospheres and upper atmospheres of exoplanets. In this work, we demonstrate a method for the selective generation of the HCCS+ ion in its triplet ground state (3Σ–) and use this method to obtain IR band positions for HCCS+. The IR-action spectrum of H2-tagged HCCS+ has been measured in a cryogenic 22-pole ion trap via IR photodissociation (IR-PD) spectroscopy with the FELIX light source in the wavenumber regions 450–1850 and 3000–3350 cm–1. Spectral information is complemented by theoretical calculations on the fragmentation mechanisms leading to the formation of HCCS+ from dissociative ionization of 2,5-dibromothiophene. The assignment of the experimental HCCS+ vibrational bands is aided by comparison with ab initio computed values from literature and from calculations at the UB3LYP/cc-pVQZ level of theory, for both the triplet (3Σ–) and singlet (1Σ+) states of HCCS+. The experimental HCCS+ spectra show an overall good agreement with the scaled theoretical values (to account for anharmonicity effects), facilitating assignment of the IR spectral features. These findings will enable new reactivity investigations and spectroscopic measurements to be conducted, and for HCCS+ to be included in astrochemical models and databases.
- Open Access
- 22 April 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (17) , 9131-9138
Separation and Detection of Charged Unilamellar Vesicles in Vacuum by a Frequency-Controlled Quadrupole Mass Sensor
Extracellular vesicles (EVs) are membranous particles released by cells and are considered to be promising sources of biomarkers for various diseases. Mass spectrometry (MS) analysis of EVs requires a sample of purified and detergent-lysed EVs. Purification of EVs is laborious, based on size, density, or surface nature, and requires large amounts of the source material (e.g., blood, spinal fluid). We have employed synthetically produced large unilamellar lipid vesicles (LUVs) as analogs of EVs to demonstrate an alternative approach to vesicle separation for subsequent mass spectrometry analysis of their composition. Mass-to-charge ratio m/z separation by frequency-controlled quadrupole was employed to filter narrow-size distributions of LUVs from a water sample. Lipid vesicles were positively charged with nanoelectrospray and transferred into a vacuum using two wide m/z-range frequency-controlled quadrupoles. The m/z, charges, and masses of individual vesicles were obtained by the nondestructive single-pass charge detector. The resolving mode of the second quadrupole with m/z RSD < 10% allowed to separate size selected distributions of vesicles with modal diameters of 88, 112, 130, 162, and 190 nm at corresponding quadrupole m/z settings of 2.5 × 105, 5 × 105, 8 × 105, 1.5 × 106, and 2.5 × 106, respectively with a rate of 20-100 counts per minute. The distributions of bioparticles with masses between 108 and 1010 Da were separated from human blood serum in the pilot experiment. The presented approach for lipid vesicle separation encourages the development of new techniques for the direct mass-spectrometric analysis of biomarkers in MS-separated EVs in a vacuum.
- 22 April 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (17) , 9131-9138
Open AccessSeparation and Detection of Charged Unilamellar Vesicles in Vacuum by a Frequency-Controlled Quadrupole Mass Sensor
Extracellular vesicles (EVs) are membranous particles released by cells and are considered to be promising sources of biomarkers for various diseases. Mass spectrometry (MS) analysis of EVs requires a sample of purified and detergent-lysed EVs. Purification of EVs is laborious, based on size, density, or surface nature, and requires large amounts of the source material (e.g., blood, spinal fluid). We have employed synthetically produced large unilamellar lipid vesicles (LUVs) as analogs of EVs to demonstrate an alternative approach to vesicle separation for subsequent mass spectrometry analysis of their composition. Mass-to-charge ratio m/z separation by frequency-controlled quadrupole was employed to filter narrow-size distributions of LUVs from a water sample. Lipid vesicles were positively charged with nanoelectrospray and transferred into a vacuum using two wide m/z-range frequency-controlled quadrupoles. The m/z, charges, and masses of individual vesicles were obtained by the nondestructive single-pass charge detector. The resolving mode of the second quadrupole with m/z RSD < 10% allowed to separate size selected distributions of vesicles with modal diameters of 88, 112, 130, 162, and 190 nm at corresponding quadrupole m/z settings of 2.5 × 105, 5 × 105, 8 × 105, 1.5 × 106, and 2.5 × 106, respectively with a rate of 20-100 counts per minute. The distributions of bioparticles with masses between 108 and 1010 Da were separated from human blood serum in the pilot experiment. The presented approach for lipid vesicle separation encourages the development of new techniques for the direct mass-spectrometric analysis of biomarkers in MS-separated EVs in a vacuum.
- 22 April 2025
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 162 (16)
Selective formation and spectroscopic characterization of the H2CCS•+ radical cation via dissociative ionization of thiophene
The chemistry of sulfur-containing molecules is of significant interest to fields ranging from the combustion of petrochemicals to astrochemistry (with multiple S-containing species unambiguously detected in the interstellar medium or circumstellar shells). Here, infrared predissociation action spectroscopy and mass-analyzed ion kinetic energy spectroscopy measurements of the m/z 58 fragment from the dissociative ionization of thiophene are presented. Comparison is made between these experimental results and ab initio calculations (of both the spectral features and the fragmentation potential energy surface), which allows the fragment to be identified as the H2CCS•+ radical cation. This conclusive identification addresses long-standing questions about the dissociative ionization of thiophene. The findings will enable further spectroscopic measurements and reactivity studies to be conducted, allowing H2CCS•+ to be incorporated into models of astrochemical environments.
- 22 April 2025
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 162 (16)
Selective formation and spectroscopic characterization of the H2CCS•+ radical cation via dissociative ionization of thiophene
The chemistry of sulfur-containing molecules is of significant interest to fields ranging from the combustion of petrochemicals to astrochemistry (with multiple S-containing species unambiguously detected in the interstellar medium or circumstellar shells). Here, infrared predissociation action spectroscopy and mass-analyzed ion kinetic energy spectroscopy measurements of the m/z 58 fragment from the dissociative ionization of thiophene are presented. Comparison is made between these experimental results and ab initio calculations (of both the spectral features and the fragmentation potential energy surface), which allows the fragment to be identified as the H2CCS•+ radical cation. This conclusive identification addresses long-standing questions about the dissociative ionization of thiophene. The findings will enable further spectroscopic measurements and reactivity studies to be conducted, allowing H2CCS•+ to be incorporated into models of astrochemical environments.
- Open Access
- 6 November 2024
- Published by Wiley in Mass Spectrometry Reviews
- Vol. 45 (2) , 193-217
Ion Chemistry in Dielectric Barrier Discharge Ionization: Recent Advances in Direct Gas Phase Analyses
Dielectric barrier discharge ionization (DBDI) sources, employing low‐temperature plasma, have emerged as sensitive and efficient ionization tools with various atmospheric pressure ionization processes. In this review, we summarize a historical overview of the development of DBDI, highlighting key principles of gas‐phase ion chemistry and the mechanisms underlying the ionization processes within the DBDI source. These processes start with the formation of reagent ions or metastable atoms from the discharge gas, which depends on the nature of the gas (helium, nitrogen, air) and on the presence of water vapor or other compounds or dopants. The processes of ionizing the analyte molecules are summarized, including Penning ionization, electron transfer, proton transfer and ligand switching from secondary hydrated hydronium ions. Presently, the DBDI‐MS methods face a challenge in the accurate quantification of gaseous analytes, limiting its broader application in biological, environmental, and medical realms where relative quantification using standards is inherently complex for gaseous matrices. Finally, we propose future avenues of research to enhance the analytical capabilities of DBDI‐MS.
- 6 November 2024
- Published by Wiley in Mass Spectrometry Reviews
- Vol. 45 (2) , 193-217
Open AccessIon Chemistry in Dielectric Barrier Discharge Ionization: Recent Advances in Direct Gas Phase Analyses
Dielectric barrier discharge ionization (DBDI) sources, employing low‐temperature plasma, have emerged as sensitive and efficient ionization tools with various atmospheric pressure ionization processes. In this review, we summarize a historical overview of the development of DBDI, highlighting key principles of gas‐phase ion chemistry and the mechanisms underlying the ionization processes within the DBDI source. These processes start with the formation of reagent ions or metastable atoms from the discharge gas, which depends on the nature of the gas (helium, nitrogen, air) and on the presence of water vapor or other compounds or dopants. The processes of ionizing the analyte molecules are summarized, including Penning ionization, electron transfer, proton transfer and ligand switching from secondary hydrated hydronium ions. Presently, the DBDI‐MS methods face a challenge in the accurate quantification of gaseous analytes, limiting its broader application in biological, environmental, and medical realms where relative quantification using standards is inherently complex for gaseous matrices. Finally, we propose future avenues of research to enhance the analytical capabilities of DBDI‐MS.
- Open Access
- 23 October 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Separation and detection of charged unilamellar vesicles in vacuum by a frequency-scanned quadrupole mass sensor
Extracellular vesicles (EVs) are membranous particles released by cells considered as a promising source of biomarkers for various diseases. Mass spectrometry (MS) analysis of EVs requires a sample of purified and disintegrated EVs. Purification of EVs is laborious, based on size, density or surface nature and requires large amounts of the source material (e.g., blood, spinal fluid). We have employed synthetically produced large unilamellar lipid vesicles (LUVs) as analogs of EVs to demonstrate a simplified method of vesicle separation for mass spectrometry analysis. Mass-to-charge ratio m/z separation by frequency-scanned quadrupole was employed to filter narrow size distributions of LUVs from a water sample. Lipid vesicles were charged with nano-electrospray and transferred into a vacuum using two wide m/z-range frequency-scanned quadrupoles. The m/z, charges and masses of individual vesicles were obtained by the nondestructive single-pass charge detector. The resolving regime of the second quadrupole with m/z RSD <10% allowed to separate size selected distributions of vesicles with modal diameters 87, 111, 130, 160, 181 nm at corresponding quadrupole m/z settings 2.5×105, 5×105, 8×105, 1.5×106, 2.5×106 with detection frequencies 20-100 per minute. The presented approach for lipid vesicles separation encourages the development of new techniques for direct mass-spectrometric analysis of biomarkers in MS-separated EVs in a vacuum.
- 23 October 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessSeparation and detection of charged unilamellar vesicles in vacuum by a frequency-scanned quadrupole mass sensor
Extracellular vesicles (EVs) are membranous particles released by cells considered as a promising source of biomarkers for various diseases. Mass spectrometry (MS) analysis of EVs requires a sample of purified and disintegrated EVs. Purification of EVs is laborious, based on size, density or surface nature and requires large amounts of the source material (e.g., blood, spinal fluid). We have employed synthetically produced large unilamellar lipid vesicles (LUVs) as analogs of EVs to demonstrate a simplified method of vesicle separation for mass spectrometry analysis. Mass-to-charge ratio m/z separation by frequency-scanned quadrupole was employed to filter narrow size distributions of LUVs from a water sample. Lipid vesicles were charged with nano-electrospray and transferred into a vacuum using two wide m/z-range frequency-scanned quadrupoles. The m/z, charges and masses of individual vesicles were obtained by the nondestructive single-pass charge detector. The resolving regime of the second quadrupole with m/z RSD <10% allowed to separate size selected distributions of vesicles with modal diameters 87, 111, 130, 160, 181 nm at corresponding quadrupole m/z settings 2.5×105, 5×105, 8×105, 1.5×106, 2.5×106 with detection frequencies 20-100 per minute. The presented approach for lipid vesicles separation encourages the development of new techniques for direct mass-spectrometric analysis of biomarkers in MS-separated EVs in a vacuum.