Jacob C. Elliott
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jacob C. Elliott has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Julianna C. Simon
Graduate Program in Acoustics, Pennsylvania State University, University Park, PA, USA
6 shared publicationsAli A. Butt
Biomedical Engineering, Pennsylvania State University, University Park, USA
2 shared publications- Julianna C. Simon
Graduate Program in Acoust., Penn State Univ., Penn State, 201E Appl. Sci. Bldg., University Park, PA 16802
2 shared publications Meghan E. Vidt
Biomedical Eng., The Penn State Univ., State College, PA
2 shared publications- Andrea P. Arguelles
Materials Research Institute The Pennsylvania State University University Park Pennsylvania USA
1 shared publication Ferdousi Sabera Rawnaque
1 shared publication
Latest Publications
- Open Access
- 5 August 2025
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 51 (11) , 2001-2010
Monitoring Fractionation in Elastic Tissues Using High Frame-Rate Doppler Ultrasound
- 5 August 2025
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 51 (11) , 2001-2010
Open AccessMonitoring Fractionation in Elastic Tissues Using High Frame-Rate Doppler Ultrasound
- Open Access
- 1 October 2024
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 156 (4_Suppleme) , A114
Biomedical Acoustics Simon Lab (BASiL) tour at penn state university
Welcome to the Biomedical Acoustics Simon Lab (BASiL)! Located in the newly constructed Engineering Collaborative Research and Education (ECoRE) building at Penn State, you can find the BASiLisks in their natural habitat. Our lab conducts a wide range of research at the intersection of diagnostic and therapeutic ultrasound, and as such, we have a large variety of equipment at our disposal for experimental use. In this video, we will give a tour of our brand new lab space, complete with demos of ultrasound field mapping, treatment monitoring, visualizing cavitation in cells, and more. In addition, the BASiLisks will give a brief overview of our new and exciting research developments. We are looking forward to showing you around our lab and hope that you can join us! [Ongoing work in the lab supported by NSF CAREER 1943937 and NIH R01EB032860.]
- 1 October 2024
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 156 (4_Suppleme) , A114
Open AccessBiomedical Acoustics Simon Lab (BASiL) tour at penn state university
Welcome to the Biomedical Acoustics Simon Lab (BASiL)! Located in the newly constructed Engineering Collaborative Research and Education (ECoRE) building at Penn State, you can find the BASiLisks in their natural habitat. Our lab conducts a wide range of research at the intersection of diagnostic and therapeutic ultrasound, and as such, we have a large variety of equipment at our disposal for experimental use. In this video, we will give a tour of our brand new lab space, complete with demos of ultrasound field mapping, treatment monitoring, visualizing cavitation in cells, and more. In addition, the BASiLisks will give a brief overview of our new and exciting research developments. We are looking forward to showing you around our lab and hope that you can join us! [Ongoing work in the lab supported by NSF CAREER 1943937 and NIH R01EB032860.]
- Open Access
- 1 March 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 153 (3_suppleme) , A357
Effect of focused ultrasound peripheral nerve stimulation on muscle mechanical properties: An in vivo murine model
Electrical muscle stimulation is limited to surface muscle activation; however, focused ultrasound (fUS) has the potential to stimulate deep skeletal muscles. This study aims to evaluate the effects of fUS peripheral nerve stimulation on muscle mechanical properties in an in vivo murine model. The sciatic nerve of 19 Sprague-Dawley rats was insonified with 3.68-MHz fUS (p+ = 6.4 MPa, p− = 5 MPa) using 10-ms pulses (0.9-ms on/0.1-ms off, 10 times) repeated at 0.5-Hz for 30, 90, or 180 severy second day for two weeks. Stimulation was monitored using electromyography (EMG) with indwelling electrodes inserted in the gastrocnemius muscle belly. Bilateral muscles were harvested for tensile mechanical testing (n = 15) and histology (n = 4). Muscle contraction was confirmed via EMG in 16/19 rats. Elastic moduli of stimulated muscles (133.2 ± 42.1 kPa) and controls (101.4 ± 39.2 kPa) were not different (ANOVA, p = 0.053). A trend toward increased elastic modulus with number of muscle stimulations was observed until 450 stimulations (not significant: ANOVA, p = 0.437), after which elastic modulus began to decrease. No tissue damage was observed histologically. The results of this pilot study demonstrate that fUS can induce repeatable muscle contraction that may improve muscle strength and mechanical properties over time. [Work supported by PSU College of Engineering Seed Grant 2021.]
- 1 March 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 153 (3_suppleme) , A357
Open AccessEffect of focused ultrasound peripheral nerve stimulation on muscle mechanical properties: An in vivo murine model
Electrical muscle stimulation is limited to surface muscle activation; however, focused ultrasound (fUS) has the potential to stimulate deep skeletal muscles. This study aims to evaluate the effects of fUS peripheral nerve stimulation on muscle mechanical properties in an in vivo murine model. The sciatic nerve of 19 Sprague-Dawley rats was insonified with 3.68-MHz fUS (p+ = 6.4 MPa, p− = 5 MPa) using 10-ms pulses (0.9-ms on/0.1-ms off, 10 times) repeated at 0.5-Hz for 30, 90, or 180 severy second day for two weeks. Stimulation was monitored using electromyography (EMG) with indwelling electrodes inserted in the gastrocnemius muscle belly. Bilateral muscles were harvested for tensile mechanical testing (n = 15) and histology (n = 4). Muscle contraction was confirmed via EMG in 16/19 rats. Elastic moduli of stimulated muscles (133.2 ± 42.1 kPa) and controls (101.4 ± 39.2 kPa) were not different (ANOVA, p = 0.053). A trend toward increased elastic modulus with number of muscle stimulations was observed until 450 stimulations (not significant: ANOVA, p = 0.437), after which elastic modulus began to decrease. No tissue damage was observed histologically. The results of this pilot study demonstrate that fUS can induce repeatable muscle contraction that may improve muscle strength and mechanical properties over time. [Work supported by PSU College of Engineering Seed Grant 2021.]
- Open Access
- 1 March 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 153 (3_suppleme) , A356
Development of an optically transparent, tendon-mimicking hydrogel for histotripsy
Collagenous, anisotropic tissues such as tendon are resilient to liquefaction by histotripsy, despite verification of cavitation activity using B-mode imaging. In previous published work, dehydrated fibrin gels were shown to mimic tendon bubble dynamics but are limited in thickness due to high opacity. Here, we aim to fabricate a thicker, more optically transparent hydrogel possessing similar cavitation dynamics to tendon. Highly transparent collagen hydrogels (TeloCol®, 10 mg/mL) were fabricated, and axial sound speeds were measured to determine anisotropy. Hydrogels were then exposed to 1.5-MHz focused ultrasound with 10-ms pulses at 1-Hz for 60 s with p + =127 MPa, p− = 35 MPa. Cavitation activity was monitored with high-speed photography and passive cavitation imaging using a Philips/ATL L7-4 transducer and Vantage® ultrasound system. Despite exhibiting low degrees of anisotropy like other non-dehydrated gels (20% lower than soft-tissue mimicking polyacrylamide. Additionally, both resilience to fractionation and transparency were notably improved compared to previously tested PureCol® collagen formulations. Different levels of collagen dehydration will be explored to further increase resilience to liquefaction and assess the role of water content in histotripsy fractionation. [Work supported by NIH R01EB032860.]
- 1 March 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 153 (3_suppleme) , A356
Open AccessDevelopment of an optically transparent, tendon-mimicking hydrogel for histotripsy
Collagenous, anisotropic tissues such as tendon are resilient to liquefaction by histotripsy, despite verification of cavitation activity using B-mode imaging. In previous published work, dehydrated fibrin gels were shown to mimic tendon bubble dynamics but are limited in thickness due to high opacity. Here, we aim to fabricate a thicker, more optically transparent hydrogel possessing similar cavitation dynamics to tendon. Highly transparent collagen hydrogels (TeloCol®, 10 mg/mL) were fabricated, and axial sound speeds were measured to determine anisotropy. Hydrogels were then exposed to 1.5-MHz focused ultrasound with 10-ms pulses at 1-Hz for 60 s with p + =127 MPa, p− = 35 MPa. Cavitation activity was monitored with high-speed photography and passive cavitation imaging using a Philips/ATL L7-4 transducer and Vantage® ultrasound system. Despite exhibiting low degrees of anisotropy like other non-dehydrated gels (20% lower than soft-tissue mimicking polyacrylamide. Additionally, both resilience to fractionation and transparency were notably improved compared to previously tested PureCol® collagen formulations. Different levels of collagen dehydration will be explored to further increase resilience to liquefaction and assess the role of water content in histotripsy fractionation. [Work supported by NIH R01EB032860.]
- 26 December 2022
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 49 (3) , 853-865
Histotripsy Bubble Dynamics in Elastic, Anisotropic Tissue-Mimicking Phantoms
- 26 December 2022
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 49 (3) , 853-865
Histotripsy Bubble Dynamics in Elastic, Anisotropic Tissue-Mimicking Phantoms
- 25 March 2022
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 50 (5) , 564-574
Automated Tissue Strain Calculations Using Harris Corner Detection
The elastic modulus, or slope of the stress-strain curve, is an important metric for evaluating tissue functionality, particularly for load-bearing tissues such as tendon. The applied force can be tracked directly from a mechanical testing system and converted to stress using the tissue cross-sectional area; however, strain can only be calculated in post-processing by tracking tissue displacement from video collected during mechanical testing. Manual tracking of Verhoeff stain lines pre-marked on the tissue is time-consuming and highly dependent upon the user. This paper details the development and testing of an automated processing method for strain calculations using Harris corner detection. The automated and manual methods were compared in a dataset consisting of 97 rat tendons (48 Achilles tendons, 49 supraspinatus tendons), divided into ten subgroups for evaluating the effects of different therapies on tendon mechanical properties. The comparison showed that average percent differences between the approaches were 0.89% and -2.10% for Achilles and supraspinatus tendons, respectively. The automated approach reduced processing time by 83% and produced similar results to the manual method when comparing the different subgroups. This automated approach to track tissue displacements and calculate elastic modulus improves post-processing time while simultaneously minimizing user dependency.
- 25 March 2022
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 50 (5) , 564-574
Automated Tissue Strain Calculations Using Harris Corner Detection
The elastic modulus, or slope of the stress-strain curve, is an important metric for evaluating tissue functionality, particularly for load-bearing tissues such as tendon. The applied force can be tracked directly from a mechanical testing system and converted to stress using the tissue cross-sectional area; however, strain can only be calculated in post-processing by tracking tissue displacement from video collected during mechanical testing. Manual tracking of Verhoeff stain lines pre-marked on the tissue is time-consuming and highly dependent upon the user. This paper details the development and testing of an automated processing method for strain calculations using Harris corner detection. The automated and manual methods were compared in a dataset consisting of 97 rat tendons (48 Achilles tendons, 49 supraspinatus tendons), divided into ten subgroups for evaluating the effects of different therapies on tendon mechanical properties. The comparison showed that average percent differences between the approaches were 0.89% and -2.10% for Achilles and supraspinatus tendons, respectively. The automated approach reduced processing time by 83% and produced similar results to the manual method when comparing the different subgroups. This automated approach to track tissue displacements and calculate elastic modulus improves post-processing time while simultaneously minimizing user dependency.
- 1 October 2021
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 150 (4_Suppleme) , A32
Histotripsy bubble dynamics in anisotropic hydrogels
Collagenous, anisotropic tissues such as tendon have demonstrated resistance to fractionation by histotripsy. B-mode imaging verifies the creation of bubbles, but oscillation and collapse of these bubbles does not cause fractionation. The objective of this work is to evaluate effects of anisotropy on bubble dynamics in tissue-mimicking hydrogels. Polyacrylamide, fibrin, and collagen hydrogels were fabricated. Axial sound speeds were measured in each direction to evaluate degree of anisotropy. Hydrogels were exposed to 1.5-MHz focused ultrasound with 10-ms pulses repeated at 1-Hz with p+ = 89 MPa, p− = 26 MPa. Cavitation activity was monitored with high-speed photography and passive cavitation imaging with a Philips/ATL L7-4 transducer and Vantage® ultrasound system. Preliminary results show violent cavitation activity and rapid fractionation in polyacrylamide, collagen, and fibrin hydrogels which have low degrees of anisotropy (90% reduction of water content resulted in a 55% reduction in peak cavitation emission energy and a 260% increase in anisotropy. This suggests an influence from anisotropy, and therefore varying axial elastic moduli, on cavitation activity that will be explored further. [Work supported by NIH R21EB027886.]
- 1 October 2021
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 150 (4_Suppleme) , A32
Histotripsy bubble dynamics in anisotropic hydrogels
Collagenous, anisotropic tissues such as tendon have demonstrated resistance to fractionation by histotripsy. B-mode imaging verifies the creation of bubbles, but oscillation and collapse of these bubbles does not cause fractionation. The objective of this work is to evaluate effects of anisotropy on bubble dynamics in tissue-mimicking hydrogels. Polyacrylamide, fibrin, and collagen hydrogels were fabricated. Axial sound speeds were measured in each direction to evaluate degree of anisotropy. Hydrogels were exposed to 1.5-MHz focused ultrasound with 10-ms pulses repeated at 1-Hz with p+ = 89 MPa, p− = 26 MPa. Cavitation activity was monitored with high-speed photography and passive cavitation imaging with a Philips/ATL L7-4 transducer and Vantage® ultrasound system. Preliminary results show violent cavitation activity and rapid fractionation in polyacrylamide, collagen, and fibrin hydrogels which have low degrees of anisotropy (90% reduction of water content resulted in a 55% reduction in peak cavitation emission energy and a 260% increase in anisotropy. This suggests an influence from anisotropy, and therefore varying axial elastic moduli, on cavitation activity that will be explored further. [Work supported by NIH R21EB027886.]
- 27 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (9) , 2981-2986
Focused Ultrasound Mechanical Disruption of Ex Vivo Rat Tendon
Around 30 million tendon injuries occur annually in the U.S. costing $\$ $ 114 billion. Conservative therapies, like dry needling, promote healing in chronically injured tendons by inducing microdamage but have mixed success rates. Focused ultrasound (fUS) therapy can noninvasively fractionate tissues through the creation, oscillation, and collapse of bubbles in a process termed histotripsy; however, highly collagenous tissues, like tendon, have shown resistance to mechanical fractionation. This study histologically evaluates whether fUS mechanical disruption is achievable in tendons. Ex vivo rat tendons (45 Achilles and 44 supraspinatus) were exposed to 1.5-MHz fUS operating with 0.1-10 ms pulses repeated at 1-100 Hz for 15-60 s with peak positive pressures <; 89 MPa and peak negative pressures <; 26 MPa; other tendons were exposed to dry needling or sham. Immediately after treatment, tendons were flash-frozen and stained with hematoxylin and eosin (H&E) or alpha-nicotinamide adenine dinucleotide diaphorase ( α-NADH-d) and evaluated by two reviewers blinded to the exposure conditions. Results showed successful creation of bubbles for all fUS-treated samples; however, not all samples showed histological injury. When the injury was detected, parameter sets with shorter pulses (0.1-1 ms), lower acoustic pressures, or reduced treatment times showed mechanical disruption in the form of fiber separation and fraying with little to no thermal injury. Longer pulses or treatment times showed a combination of mechanical and thermal injury. These findings suggest that mechanical disruption is achievable in tendons within a small window of acoustic parameters, supporting the potential of fUS therapy in tendon treatment.- 27 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (9) , 2981-2986
Focused Ultrasound Mechanical Disruption of Ex Vivo Rat Tendon
Around 30 million tendon injuries occur annually in the U.S. costing $\$ $ 114 billion. Conservative therapies, like dry needling, promote healing in chronically injured tendons by inducing microdamage but have mixed success rates. Focused ultrasound (fUS) therapy can noninvasively fractionate tissues through the creation, oscillation, and collapse of bubbles in a process termed histotripsy; however, highly collagenous tissues, like tendon, have shown resistance to mechanical fractionation. This study histologically evaluates whether fUS mechanical disruption is achievable in tendons. Ex vivo rat tendons (45 Achilles and 44 supraspinatus) were exposed to 1.5-MHz fUS operating with 0.1-10 ms pulses repeated at 1-100 Hz for 15-60 s with peak positive pressures <; 89 MPa and peak negative pressures <; 26 MPa; other tendons were exposed to dry needling or sham. Immediately after treatment, tendons were flash-frozen and stained with hematoxylin and eosin (H&E) or alpha-nicotinamide adenine dinucleotide diaphorase ( α-NADH-d) and evaluated by two reviewers blinded to the exposure conditions. Results showed successful creation of bubbles for all fUS-treated samples; however, not all samples showed histological injury. When the injury was detected, parameter sets with shorter pulses (0.1-1 ms), lower acoustic pressures, or reduced treatment times showed mechanical disruption in the form of fiber separation and fraying with little to no thermal injury. Longer pulses or treatment times showed a combination of mechanical and thermal injury. These findings suggest that mechanical disruption is achievable in tendons within a small window of acoustic parameters, supporting the potential of fUS therapy in tendon treatment.