Toru Takahashi
Toru Takahashi has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Fujio Kurokawa
Institute for Innovative Science and Technology, Nagasaki Institute of Applied Science, Nagasaki, Japan
4 shared publications - Hiroaki Kusawake
Japan Aerospace Exploration Agency, Tsukuba, Japan
4 shared publications - Hiroki Watanabe
Japan Aerospace Exploration Agency
4 shared publications - Ikkoh Funaki
Japan Aerospace Exploration Agency, Sagamihara, Japan
4 shared publications - Kazuhiro Kajiwara
Nagasaki Institute of Applied Science, Nagasaki, Japan
4 shared publications - Shinatora Cho
Japan Aerospace Exploration Agency
4 shared publications
Latest Publications
- Open Access
- 26 June 2025
- Published by Springer Nature in Journal of Electric Propulsion
- Vol. 4 (1) , 1-18
Discharge current amplitude detection in power processing units for hall thrusters
Discharge current oscillation in Hall thrusters can cause noise or, in the worst case, severe damage to the satellite. An amplitude detection system senses the discharge current and can shut off the thruster if excessive oscillations occur. The system divides a waveform 100 ms long and sampled at 1 MHz into 1000 segments and calculates the current amplitude in each segment. Next, a Power Processing Unit (PPU) calculates the number of segments where the current threshold is exceeded and determines whether the thruster should stop running. The proposed system was installed in a PPU2, PPU for 6 kW thrusters, and PPU Technology Development Unit 2 (PPU-TDU2) for 1 kW thrusters. In a test of the PPU2, the system detected 905 peaks over the threshold of 5.1 A during the 100 ms period, which has acceptable agreement with the actual number of peaks, 931. In addition, the thruster can be automatically changed to a state with a low-amplitude discharge current by changing the magnetic field. In a test of the PPU-TDU2, the maximum amplitude of 4.3 A calculated by the system agreed well with the peak value of 4.07 A calculated from the current waveform on an oscilloscope. These results reveal that the amplitude detection system is sufficiently accurate for thrusters of different power levels.
- 26 June 2025
- Published by Springer Nature in Journal of Electric Propulsion
- Vol. 4 (1) , 1-18
Open AccessDischarge current amplitude detection in power processing units for hall thrusters
Discharge current oscillation in Hall thrusters can cause noise or, in the worst case, severe damage to the satellite. An amplitude detection system senses the discharge current and can shut off the thruster if excessive oscillations occur. The system divides a waveform 100 ms long and sampled at 1 MHz into 1000 segments and calculates the current amplitude in each segment. Next, a Power Processing Unit (PPU) calculates the number of segments where the current threshold is exceeded and determines whether the thruster should stop running. The proposed system was installed in a PPU2, PPU for 6 kW thrusters, and PPU Technology Development Unit 2 (PPU-TDU2) for 1 kW thrusters. In a test of the PPU2, the system detected 905 peaks over the threshold of 5.1 A during the 100 ms period, which has acceptable agreement with the actual number of peaks, 931. In addition, the thruster can be automatically changed to a state with a low-amplitude discharge current by changing the magnetic field. In a test of the PPU-TDU2, the maximum amplitude of 4.3 A calculated by the system agreed well with the peak value of 4.07 A calculated from the current waveform on an oscilloscope. These results reveal that the amplitude detection system is sufficiently accurate for thrusters of different power levels.
- Open Access
- 4 April 2025
- Published by Springer Nature in Research Square
Discharge Current Amplitude Detection in Power Processing Units for Hall Thrusters
Discharge current oscillation in Hall thrusters can cause noise or, in the worst case, severe damage to the satellite. An amplitude detection system senses the discharge current and can shut off the thruster if excessive oscillations occur. The system divides a waveform 100 ms long and sampled at 1 MHz into 1000 segments and calculates the current amplitude in each segment. Next, a Power Processing Unit (PPU) calculates the number of segments where the current threshold is exceeded and determines whether the thruster should stop running. The proposed system was installed in a PPU2, PPU for 6 kW thrusters, and PPU Technology Development Unit 2 (PPU-TDU2) for 1 kW thrusters. In a test of the PPU2, the system detected 905 peaks over the threshold of 5.1 A during the 100 ms period, which agrees with the actual number of peaks, 931. In addition, the thruster can be automatically changed to a state with a low-amplitude discharge current by changing the magnetic field. In a test of the PPU-TDU2, the maximum amplitude of 4.3 A calculated by the system agreed well with the peak value of 4.07 A calculated from the current waveform on an oscilloscope. These results reveal that the amplitude detection system is sufficiently accurate for thrusters of different power levels.
- 4 April 2025
- Published by Springer Nature in Research Square
Open AccessDischarge Current Amplitude Detection in Power Processing Units for Hall Thrusters
Discharge current oscillation in Hall thrusters can cause noise or, in the worst case, severe damage to the satellite. An amplitude detection system senses the discharge current and can shut off the thruster if excessive oscillations occur. The system divides a waveform 100 ms long and sampled at 1 MHz into 1000 segments and calculates the current amplitude in each segment. Next, a Power Processing Unit (PPU) calculates the number of segments where the current threshold is exceeded and determines whether the thruster should stop running. The proposed system was installed in a PPU2, PPU for 6 kW thrusters, and PPU Technology Development Unit 2 (PPU-TDU2) for 1 kW thrusters. In a test of the PPU2, the system detected 905 peaks over the threshold of 5.1 A during the 100 ms period, which agrees with the actual number of peaks, 931. In addition, the thruster can be automatically changed to a state with a low-amplitude discharge current by changing the magnetic field. In a test of the PPU-TDU2, the maximum amplitude of 4.3 A calculated by the system agreed well with the peak value of 4.07 A calculated from the current waveform on an oscilloscope. These results reveal that the amplitude detection system is sufficiently accurate for thrusters of different power levels.
- Open Access
- 6 December 2022
- Published by Springer Nature in Journal of Electric Propulsion
- Vol. 1 (1) , 1-13
Control algorithm for a 6 kW hall thruster
This paper presents a control algorithm for ensuring the stable operation of a 6 kW Hall thruster. The Japan Aerospace Exploration Agency is developing a “wide-range” power processing unit (PPU) to power a 6 kW Hall thruster system, a candidate for all-electric satellites. The PPU provides discharge oscillation, power, and discharge current control. The increments in the control loop are fixed, so the PPU digital controller does not need to calculate them, and the algorithm’s computational complexity is minimal. Results of integration tests on the 6 kW Hall thruster and the PPU breadboard model showed that the three control functions run correctly. The total controlled PPU power was adjusted in the range of 3.45–3.55 kW under constant power control with a target of 3.5 kW. Oscillations of ± 0.05 kW around the target power are acceptable. 70% of the peaks in the discharge current acquired for 100 ms exceeded the limit of 1.5A. Discharge oscillation control varied the coil magnetic field and reduced them to 0%. The PPU successfully controlled the coil current, reducing the discharge current from 13.7 A to 13 A. The propulsion efficiency increased from 59% to 60.5%.
- 6 December 2022
- Published by Springer Nature in Journal of Electric Propulsion
- Vol. 1 (1) , 1-13
Open AccessControl algorithm for a 6 kW hall thruster
This paper presents a control algorithm for ensuring the stable operation of a 6 kW Hall thruster. The Japan Aerospace Exploration Agency is developing a “wide-range” power processing unit (PPU) to power a 6 kW Hall thruster system, a candidate for all-electric satellites. The PPU provides discharge oscillation, power, and discharge current control. The increments in the control loop are fixed, so the PPU digital controller does not need to calculate them, and the algorithm’s computational complexity is minimal. Results of integration tests on the 6 kW Hall thruster and the PPU breadboard model showed that the three control functions run correctly. The total controlled PPU power was adjusted in the range of 3.45–3.55 kW under constant power control with a target of 3.5 kW. Oscillations of ± 0.05 kW around the target power are acceptable. 70% of the peaks in the discharge current acquired for 100 ms exceeded the limit of 1.5A. Discharge oscillation control varied the coil magnetic field and reduced them to 0%. The PPU successfully controlled the coil current, reducing the discharge current from 13.7 A to 13 A. The propulsion efficiency increased from 59% to 60.5%.
- 4 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Aerospace and Electronic Systems
- Vol. 58 (3) , 1609-1620
Wide-Output Range Power Processing Unit for 6-kW Hall Thruster
The Japan Aerospace Exploration Agency (JAXA) has developed a power processing unit (PPU) for a 6 kW Hall thruster system. The PPU is a candidate for future mission applications, such as all-electric satellites, exploration vehicles, and orbital transfer services. The PPU has to be small and still provide a wide output range of outputs, consider the in orbit and launch environments, and manage any instability in the Hall thruster's discharge. Specifically, the four converters that make up the anode power supply of the PPU is digitally controlled to reduce the size of the control circuit. It must operate stably despite small output capacitors and long dead times. This paper clarifies the design criteria for the power supply, focusing on the size of capacitors and the PI control parameters to solve these problems. The result is a compact, high-performance PPU for the 6 kW Hall thruster. The power supply meets stringent design criteria and operates the thruster stably with an output voltage that can be varied between 200 and 730 V, provide a maximum power of 5.9 kW, and offer a maximum efficiency of 96.1% in the coupling test for the 6 kW Hall thruster. The proposed PPU, including the anode power supply, achieves a power density of 0.3 kW/kg, significantly higher than that of comparable PPUs.
- 4 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Aerospace and Electronic Systems
- Vol. 58 (3) , 1609-1620
Wide-Output Range Power Processing Unit for 6-kW Hall Thruster
The Japan Aerospace Exploration Agency (JAXA) has developed a power processing unit (PPU) for a 6 kW Hall thruster system. The PPU is a candidate for future mission applications, such as all-electric satellites, exploration vehicles, and orbital transfer services. The PPU has to be small and still provide a wide output range of outputs, consider the in orbit and launch environments, and manage any instability in the Hall thruster's discharge. Specifically, the four converters that make up the anode power supply of the PPU is digitally controlled to reduce the size of the control circuit. It must operate stably despite small output capacitors and long dead times. This paper clarifies the design criteria for the power supply, focusing on the size of capacitors and the PI control parameters to solve these problems. The result is a compact, high-performance PPU for the 6 kW Hall thruster. The power supply meets stringent design criteria and operates the thruster stably with an output voltage that can be varied between 200 and 730 V, provide a maximum power of 5.9 kW, and offer a maximum efficiency of 96.1% in the coupling test for the 6 kW Hall thruster. The proposed PPU, including the anode power supply, achieves a power density of 0.3 kW/kg, significantly higher than that of comparable PPUs.
- 1 January 2012
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 132 (3) , 220-225
Comparison of Performances of Scramjet-Driven Experimental DCW-MHD Generators with Different Cross-Section
- 1 January 2012
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 132 (3) , 220-225
Comparison of Performances of Scramjet-Driven Experimental DCW-MHD Generators with Different Cross-Section
- 1 March 2010
- Published by Australian Society of Exploration Geophysicists in Exploration Geophysics
- Vol. 41 (1) , 102-108
An attempt at soil profiling on a river embankment using geophysical dataFN1
Exploration Geophysics is published by CSIRO PUBLISHING on behalf of the Australian Society of Exploration Geophysicists. Papers published report the results of significant case histories and relevant original research in geophysics, with emphasis on the Australian and similar environments.
- 1 March 2010
- Published by Australian Society of Exploration Geophysicists in Exploration Geophysics
- Vol. 41 (1) , 102-108
An attempt at soil profiling on a river embankment using geophysical dataFN1
Exploration Geophysics is published by CSIRO PUBLISHING on behalf of the Australian Society of Exploration Geophysicists. Papers published report the results of significant case histories and relevant original research in geophysics, with emphasis on the Australian and similar environments.