Pan Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pan Zhang has a total of 113 co-authors. Here are the top co-authors by number of shared publications:
- Yuan Wang
University of Macau
6 shared publications - Chen Wang
Department of Electrical Engineering (ESAT-MNS), KU Leuven, Leuven, Belgium
5 shared publications - Jun-Hui Yuan
School of Physics and Mechanics, Wuhan University of Technology, Wuhan 430070, China
5 shared publications - Wei Wang
Peking University
5 shared publications - Xiaodong Lin
University of California, Riverside , 900 University Ave.
5 shared publications - Han Xu
School of Integrated Circuits, Peking University, Beijing, China
4 shared publications
Latest Publications
- Open Access
- 9 November 2026
- Published by Springer Nature in Research Square
Toward Self-Improving MEMS Research Agents through Experience-Informed Procedure Refinement
Microelectromechanical systems (MEMS) research requires translating device concepts into geometries with physically meaningful behavior under specified structural constraints. Although research agents increasingly automate scientific workflows, successful numerical execution alone does not establish operating-mode identity and dynamic behavior, identify loss mechanisms, or verify geometric compliance. Here we introduce the MEMS Research Agent Framework, which brings agent-based research and experience-informed procedure refinement into an expert-guided MEMS workflow. Agents execute investigations using reusable instructions and scripts, while experts define objectives, assess physical interpretations, and review methodological changes. In a researcher-guided study of a silicon double-ended tuning-fork resonator, the proposed framework carries a literature-derived thermoelastic-dissipation hypothesis through geometry construction, coupled-field simulation, and operating-mode identification. The selected segmented-slot design achieves a modeled thermoelastic quality factor approximately 5.2 times the baseline at a resonant frequency 20% lower. The slotting mechanism is consistent with a published experimental study reporting a 5.9-fold increase in measured quality factor in a different geometry. Development histories trace a procedural route toward self-improvement: recorded failures inform expert-reviewed changes to research instructions and diagnostic checks reused in subsequent runs. A registered comparison across 25 runs evaluates research outcomes and evidence completeness under five frozen configurations. The final author assessment gives 1/5 successful runs without the proposed framework and 5/5 with it; the initial model-judge assessment gives 1/5 and 2/5, respectively, reflecting differences in evidence acceptance. These studies demonstrate the feasibility of delegating parts of MEMS inverse-design iterations to agents, laying a foundation for self-improving research automation in device design and discovery.
- 9 November 2026
- Published by Springer Nature in Research Square
Open AccessToward Self-Improving MEMS Research Agents through Experience-Informed Procedure Refinement
Microelectromechanical systems (MEMS) research requires translating device concepts into geometries with physically meaningful behavior under specified structural constraints. Although research agents increasingly automate scientific workflows, successful numerical execution alone does not establish operating-mode identity and dynamic behavior, identify loss mechanisms, or verify geometric compliance. Here we introduce the MEMS Research Agent Framework, which brings agent-based research and experience-informed procedure refinement into an expert-guided MEMS workflow. Agents execute investigations using reusable instructions and scripts, while experts define objectives, assess physical interpretations, and review methodological changes. In a researcher-guided study of a silicon double-ended tuning-fork resonator, the proposed framework carries a literature-derived thermoelastic-dissipation hypothesis through geometry construction, coupled-field simulation, and operating-mode identification. The selected segmented-slot design achieves a modeled thermoelastic quality factor approximately 5.2 times the baseline at a resonant frequency 20% lower. The slotting mechanism is consistent with a published experimental study reporting a 5.9-fold increase in measured quality factor in a different geometry. Development histories trace a procedural route toward self-improvement: recorded failures inform expert-reviewed changes to research instructions and diagnostic checks reused in subsequent runs. A registered comparison across 25 runs evaluates research outcomes and evidence completeness under five frozen configurations. The final author assessment gives 1/5 successful runs without the proposed framework and 5/5 with it; the initial model-judge assessment gives 1/5 and 2/5, respectively, reflecting differences in evidence acceptance. These studies demonstrate the feasibility of delegating parts of MEMS inverse-design iterations to agents, laying a foundation for self-improving research automation in device design and discovery.
- Open Access
- 9 September 2026
- Published by MDPI AG in Nanomaterials
- Vol. 16 (18) , 1127
Surface Hydrogenation Strategy for Constructing a 2D B12X2H8 (X = N, P, As) Family with Embedded Aromatic Icosahedral B12 Superatoms
Surface hydrogenation is a key strategy for material modification. The icosahedral B12 superatom, featuring a closed-shell electronic structure and aromatic stability, serves as an ideal building block for 2D functional materials. Using first-principles calculations, we design highly stable 2D boron-based h-B12X2H8 (X = N, P, As) by hydrogenating the parent h-B12X2 phases proposed in our previous work. Hydrogenation widens the bandgap from ~1 eV to 5.19–6.00 eV, strengthens bonding, and improves mechanical properties (higher Young’s modulus and lower Poisson’s ratio). Modified deformation-potential theory reveals carrier-type-selective mobilities, with the electron mobility of h-B12P2H8 reaching 1755 cm2V−1s−1. Notably, when h-B12X2H8 forms a heterojunction with its parent phase, it acts as a protective layer that preserves the parent’s electronic structure, facilitating applications in harsh environments. This work provides a rational pathway for designing B12-based 2D materials via surface passivation and offers a model for constructing self-passivating protective layers on 2D materials.
- 9 September 2026
- Published by MDPI AG in Nanomaterials
- Vol. 16 (18) , 1127
Open AccessSurface Hydrogenation Strategy for Constructing a 2D B12X2H8 (X = N, P, As) Family with Embedded Aromatic Icosahedral B12 Superatoms
Surface hydrogenation is a key strategy for material modification. The icosahedral B12 superatom, featuring a closed-shell electronic structure and aromatic stability, serves as an ideal building block for 2D functional materials. Using first-principles calculations, we design highly stable 2D boron-based h-B12X2H8 (X = N, P, As) by hydrogenating the parent h-B12X2 phases proposed in our previous work. Hydrogenation widens the bandgap from ~1 eV to 5.19–6.00 eV, strengthens bonding, and improves mechanical properties (higher Young’s modulus and lower Poisson’s ratio). Modified deformation-potential theory reveals carrier-type-selective mobilities, with the electron mobility of h-B12P2H8 reaching 1755 cm2V−1s−1. Notably, when h-B12X2H8 forms a heterojunction with its parent phase, it acts as a protective layer that preserves the parent’s electronic structure, facilitating applications in harsh environments. This work provides a rational pathway for designing B12-based 2D materials via surface passivation and offers a model for constructing self-passivating protective layers on 2D materials.
- Open Access
- 30 March 2026
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 12 (1)
A cochlea bio-inspired tunable piezoelectric cantilever array MEMS microphone: comprehensive study
This study introduces a bio-inspired AlN-piezoelectric MEMS microphone that showcases a cantilever structure offering adjustable performance, fully emulating the dynamics and tunability observed in the basilar membrane of the mammalian cochlea. Through the incorporation of piezoelectric and converse piezoelectric effects alongside dual parametric modulation mechanisms, the device successfully replicates three crucial aspects of cochlear mechanics: i) sensory transduction characteristic of inner hair cell (IHC); ii) local stiffness modulation enabled by outer hair cell (OHC) somatic motility; and iii) energy redistribution in coupled-system recapitulating the energy transfer of cochlear traveling wave dynamics. The device performance was systematically characterized through electrical characterizations, optical analysis, and acoustic measurements. Experimental results demonstrate a baseline sensitivity of −25.38 dB/Pa and signal-to-noise ratios up to 79.28 dB within an operation bandwidth from 1.755 to 2.261 kHz (3 dB cut-on and cut-off bandwidth), while the quality factor (Q) can be tuned to a value ranging from −55.38% to 180.10% of initial values, representing a 124.72% tuning span. In essence, the critical innovations encompass: i) a MEMS microphone that pioneers the first fully mimicking simultaneous sensing/tuning functionality of the mammalian cochlea, through piezoelectric and converse piezoelectric effects; ii) a combination of two novel tuning mechanisms, i.e., AC (through parametric modulation) and mechanical coupling, are applied without the necessity for mechanical structure modification. It can be envisioned that such a technology enables next-generation hearing aids with bio-inspired auditory adaptation, bridging a critical gap in prosthetic sound processing, while also catering to the ever-increasing demands of intelligent acoustic sensors.
- 30 March 2026
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 12 (1)
Open AccessA cochlea bio-inspired tunable piezoelectric cantilever array MEMS microphone: comprehensive study
This study introduces a bio-inspired AlN-piezoelectric MEMS microphone that showcases a cantilever structure offering adjustable performance, fully emulating the dynamics and tunability observed in the basilar membrane of the mammalian cochlea. Through the incorporation of piezoelectric and converse piezoelectric effects alongside dual parametric modulation mechanisms, the device successfully replicates three crucial aspects of cochlear mechanics: i) sensory transduction characteristic of inner hair cell (IHC); ii) local stiffness modulation enabled by outer hair cell (OHC) somatic motility; and iii) energy redistribution in coupled-system recapitulating the energy transfer of cochlear traveling wave dynamics. The device performance was systematically characterized through electrical characterizations, optical analysis, and acoustic measurements. Experimental results demonstrate a baseline sensitivity of −25.38 dB/Pa and signal-to-noise ratios up to 79.28 dB within an operation bandwidth from 1.755 to 2.261 kHz (3 dB cut-on and cut-off bandwidth), while the quality factor (Q) can be tuned to a value ranging from −55.38% to 180.10% of initial values, representing a 124.72% tuning span. In essence, the critical innovations encompass: i) a MEMS microphone that pioneers the first fully mimicking simultaneous sensing/tuning functionality of the mammalian cochlea, through piezoelectric and converse piezoelectric effects; ii) a combination of two novel tuning mechanisms, i.e., AC (through parametric modulation) and mechanical coupling, are applied without the necessity for mechanical structure modification. It can be envisioned that such a technology enables next-generation hearing aids with bio-inspired auditory adaptation, bridging a critical gap in prosthetic sound processing, while also catering to the ever-increasing demands of intelligent acoustic sensors.
- Open Access
- 10 February 2026
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 12 (1) , 55
Machine learning based real-time assessment of fabrication deviation induced mechanical performance variations in stretchable silicon arrays
Microelectromechanical system fabrication represents a promising approach for silicon-based flexible electronics, leveraging its scalability and miniaturization merits. However, fabrication-induced geometric deviations stretchable microstructures can result in significant variations in mechanical performances. Current assessment methods lack sufficient accuracy for these precision-sensitive manufacturing processes. This work proposes a machine-learning (ML)-based assessment methodology for accurately and rapidly predicting the mechanical performances, including equivalent Young's modulus and the maximum elastic stretchability, of Parylene three-dimensional micro-Kirigami stretchable structures in a stretchable silicon array affected by the fabrication-induced geometric deviations. By applying the dimensionality reduction technique specifically designed for few-shot ML modeling, the framework achieves prediction accuracies exceeding 95% on the test set. SHapley Additive exPlanations (SHAP) analysis is further utilized to quantify the impact of various geometric features on mechanical performances. This ML-based assessment methodology successfully facilitates real-time feedback from process-induced geometric deviations to the qualification probability of mechanical performances. This proposed approach supports design-for-manufacturability (DFM) of silicon-based stretchable arrayed devices manufacturing and lays the foundation for high-consistency wafer-scale manufacturing of high-performance stretchable silicon electronics.
- 10 February 2026
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 12 (1) , 55
Open AccessMachine learning based real-time assessment of fabrication deviation induced mechanical performance variations in stretchable silicon arrays
Microelectromechanical system fabrication represents a promising approach for silicon-based flexible electronics, leveraging its scalability and miniaturization merits. However, fabrication-induced geometric deviations stretchable microstructures can result in significant variations in mechanical performances. Current assessment methods lack sufficient accuracy for these precision-sensitive manufacturing processes. This work proposes a machine-learning (ML)-based assessment methodology for accurately and rapidly predicting the mechanical performances, including equivalent Young's modulus and the maximum elastic stretchability, of Parylene three-dimensional micro-Kirigami stretchable structures in a stretchable silicon array affected by the fabrication-induced geometric deviations. By applying the dimensionality reduction technique specifically designed for few-shot ML modeling, the framework achieves prediction accuracies exceeding 95% on the test set. SHapley Additive exPlanations (SHAP) analysis is further utilized to quantify the impact of various geometric features on mechanical performances. This ML-based assessment methodology successfully facilitates real-time feedback from process-induced geometric deviations to the qualification probability of mechanical performances. This proposed approach supports design-for-manufacturability (DFM) of silicon-based stretchable arrayed devices manufacturing and lays the foundation for high-consistency wafer-scale manufacturing of high-performance stretchable silicon electronics.
- 25 August 2025
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 10 (9) , 6962-6970
Digital Profiling Subpopulations of Cancer Cell-Derived Exosomes via Aptamer-SERS Nanotags on a Wafer-Level Micropillar Array Chip
The clinical translation of exosome-based diagnostics and therapies is hindered by significant molecular heterogeneity. Current exosome phenotyping methods suffer from insufficient sensitivity, limited multiplexing capability, and poor scalability. To address these challenges, we developed a digital wafer-level micropillar array (WLM-Exo) platform. The chip features a high-surface-area micropillar array functionalized with a DSPE-PEG2000 lipid layer via Au-S bonding, enabling lipid-mediated membrane fusion for universal exosome enrichment and a uniform spatial distribution. Following capture, aptamer-based SERS nanotags bind specifically to target proteins on exosomes, generating distinct Raman signals upon laser excitation. Exosomal proteins are digitally quantified by measuring the activated area in the Raman images, exhibiting a log-log linear correlation with exosome concentration. The WLM-Exo platform demonstrates ultrasensitive detection (LOD: 2.11 particles/μL for CD63, 1.17 particles/μL for EpCAM, and 18.3 particles/μL for dual-biomarkers) and simultaneous tetra-color exosomal phenotyping capability. By enabling precise, scalable, and digital protein profiling, this technology offers significant potential for exosomes subtyping in personalized cancer diagnostics and therapeutics monitoring.
- 25 August 2025
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 10 (9) , 6962-6970
Digital Profiling Subpopulations of Cancer Cell-Derived Exosomes via Aptamer-SERS Nanotags on a Wafer-Level Micropillar Array Chip
The clinical translation of exosome-based diagnostics and therapies is hindered by significant molecular heterogeneity. Current exosome phenotyping methods suffer from insufficient sensitivity, limited multiplexing capability, and poor scalability. To address these challenges, we developed a digital wafer-level micropillar array (WLM-Exo) platform. The chip features a high-surface-area micropillar array functionalized with a DSPE-PEG2000 lipid layer via Au-S bonding, enabling lipid-mediated membrane fusion for universal exosome enrichment and a uniform spatial distribution. Following capture, aptamer-based SERS nanotags bind specifically to target proteins on exosomes, generating distinct Raman signals upon laser excitation. Exosomal proteins are digitally quantified by measuring the activated area in the Raman images, exhibiting a log-log linear correlation with exosome concentration. The WLM-Exo platform demonstrates ultrasensitive detection (LOD: 2.11 particles/μL for CD63, 1.17 particles/μL for EpCAM, and 18.3 particles/μL for dual-biomarkers) and simultaneous tetra-color exosomal phenotyping capability. By enabling precise, scalable, and digital protein profiling, this technology offers significant potential for exosomes subtyping in personalized cancer diagnostics and therapeutics monitoring.
- 29 March 2025
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 25 (14) , 5646-5655
Nanofluidic Memristive Transition and Synaptic Emulation in Atomically Thin Pores
Ionic transport across nanochannels is the basis of communications in living organisms, enlightening neuromorphic nanofluidic iontronics. Comparing to the angstrom-scale long biological ionic pathways, it remains a great challenge to achieve nanofluidic memristors at such thinnest limit due to the ambiguous electrical model and interaction process. Here, we report atomically thin memristive nanopores in two-dimensional materials by designing optimized ionic conductance to decouple the memristive, ohmic, and capacitive effects. By conducting different charged iontronics, we realize the reconfigurable memristive transition between nonvolatile-bipolar and volatile-unipolar characteristics, which arises from distinct transport processes governed by energy barriers. Notably, we emulate synaptic functions with ultralow energy consumption of ∼0.546 pJ per spike and reproduce biological learning behaviors. The memristive nanopores are similar to the biosystems in angstrom structure, rich iontronic responses, and millisecond-level operating pulse width, matching the biological potential width. This work provides a new paradigm for boosting brain-inspired nanofluidic devices.
- 29 March 2025
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 25 (14) , 5646-5655
Nanofluidic Memristive Transition and Synaptic Emulation in Atomically Thin Pores
Ionic transport across nanochannels is the basis of communications in living organisms, enlightening neuromorphic nanofluidic iontronics. Comparing to the angstrom-scale long biological ionic pathways, it remains a great challenge to achieve nanofluidic memristors at such thinnest limit due to the ambiguous electrical model and interaction process. Here, we report atomically thin memristive nanopores in two-dimensional materials by designing optimized ionic conductance to decouple the memristive, ohmic, and capacitive effects. By conducting different charged iontronics, we realize the reconfigurable memristive transition between nonvolatile-bipolar and volatile-unipolar characteristics, which arises from distinct transport processes governed by energy barriers. Notably, we emulate synaptic functions with ultralow energy consumption of ∼0.546 pJ per spike and reproduce biological learning behaviors. The memristive nanopores are similar to the biosystems in angstrom structure, rich iontronic responses, and millisecond-level operating pulse width, matching the biological potential width. This work provides a new paradigm for boosting brain-inspired nanofluidic devices.
- 10 February 2025
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 41 (6) , 4005-4015
ZnCo Bimetallic Macro-Microporous Metal–Organic Frameworks for Efficient Adsorption of Dyes
The significant threat posed by dye wastewater has driven the development of efficient adsorbents, such as metal organic frameworks (MOFs). Specifically, we explore the synthesis and application of ZnCo-based bimetallic zeolite imidazolate frameworks with a macro-microporous structure (SOM-ZnCo-ZIF), which exhibit enhanced adsorption capacity for dyes due to their large specific surface area and ordered porous arrangement. When SOM-ZnCo-ZIF is immersed in DMA solutions of methylene blue, methyl orange, crystal violet, and rhodamine B, due to its high specific surface area and the synergistic effect of ZnCo bimetallic clusters, SOM-ZnCo-ZIF significantly enhances dye adsorption. Notably, its adsorption capacity for Rhodamine B reaches an impressive 6798.9 mg/g, and within just 1 min, 0.5 g/L of SOM-ZnCo-ZIF can remove over 97% of Rhodamine B from a 60 mg/L solution. Moreover, it maintained a 92.8% dye removal efficiency in ten cycles without regeneration, demonstrating the effective adsorption capacity of SOM-ZnCo-ZIF. Density functional theory calculations have shown that the adsorption energy of ZnCo bimetallic ZIF for Rhodamine B is approximately twice that of a single metal. SOM-ZnCo-ZIF exhibits strong adsorption of Rhodamine B mainly due to its macro-microporous structure, which provides larger pore sizes (∼250 nm) allowing the dye molecules to infiltrate the porous network, and its ability to facilitate π-π stacking interactions between the benzene rings of Rhodamine B and the imidazole rings of the ZIF. Additionally, the interaction is further enhanced by strong coordination bonds and electrostatic interactions between the cationic dye and the negatively charged framework. This work not only proposes an effective adsorbent to remove Rhodamine B but also provides valuable insights for the rational design and synthesis of environmentally sustainable MOF structures.
- 10 February 2025
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 41 (6) , 4005-4015
ZnCo Bimetallic Macro-Microporous Metal–Organic Frameworks for Efficient Adsorption of Dyes
The significant threat posed by dye wastewater has driven the development of efficient adsorbents, such as metal organic frameworks (MOFs). Specifically, we explore the synthesis and application of ZnCo-based bimetallic zeolite imidazolate frameworks with a macro-microporous structure (SOM-ZnCo-ZIF), which exhibit enhanced adsorption capacity for dyes due to their large specific surface area and ordered porous arrangement. When SOM-ZnCo-ZIF is immersed in DMA solutions of methylene blue, methyl orange, crystal violet, and rhodamine B, due to its high specific surface area and the synergistic effect of ZnCo bimetallic clusters, SOM-ZnCo-ZIF significantly enhances dye adsorption. Notably, its adsorption capacity for Rhodamine B reaches an impressive 6798.9 mg/g, and within just 1 min, 0.5 g/L of SOM-ZnCo-ZIF can remove over 97% of Rhodamine B from a 60 mg/L solution. Moreover, it maintained a 92.8% dye removal efficiency in ten cycles without regeneration, demonstrating the effective adsorption capacity of SOM-ZnCo-ZIF. Density functional theory calculations have shown that the adsorption energy of ZnCo bimetallic ZIF for Rhodamine B is approximately twice that of a single metal. SOM-ZnCo-ZIF exhibits strong adsorption of Rhodamine B mainly due to its macro-microporous structure, which provides larger pore sizes (∼250 nm) allowing the dye molecules to infiltrate the porous network, and its ability to facilitate π-π stacking interactions between the benzene rings of Rhodamine B and the imidazole rings of the ZIF. Additionally, the interaction is further enhanced by strong coordination bonds and electrostatic interactions between the cationic dye and the negatively charged framework. This work not only proposes an effective adsorbent to remove Rhodamine B but also provides valuable insights for the rational design and synthesis of environmentally sustainable MOF structures.
- 28 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (3) , 1345-1351
Enhanced Mode Localization in 2-DoF Weakly Coupled Electrostatic MEMS Resonant Sensor Devices via Blue-Sideband Excitation
This article for the first time introduces the blue-sideband excitation (BSE) scheme to two types of 2-degree-of-freedom (2-DoF) weakly coupled electrostatic resonant sensors, i.e., a 2-DoF electrostatically coupled resonating system with parallel suspension beams (Device 1) and a 2-DoF coupled double-ended tuning fork (DETF) resonant device (Device 2), boosting the functionality of the mode localization phenomena and ultimately achieving distinct performance upgradation. The amplitude ratio (AR) is hence adopted as the readout metric for the sensitivity characterization with respect to different external stiffness perturbations introduced by the capacitive transduction. Three paradigms of AR were implemented in this subject, namely, intermodal AR (IM-AR), interresonator AR (IR-AR), and interresonator-IM-AR (IRIM-AR), owing to the feature of simultaneous multiple-mode excitation of BSE. A comparison regarding the coupled resonant devices subject to the conventional drive scheme and the BSE was conducted, where the experimental results indicated that more than two orders of magnitude enhancement in sensitivity were achieved with the BSE scheme, along with the possibility of a pronounced $\sim$17 times improvement in the noise floor, as well as the capability of simultaneous multiple parameter extraction across different resonators and vibration modes within the coupled system. This work further verified the feasibility and effectiveness of the BSE scheme, demonstrating the potential of such a technique for sensing applications based on mode-localized resonant sensors, fostering ultrahigh performance augmentation.
- 28 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (3) , 1345-1351
Enhanced Mode Localization in 2-DoF Weakly Coupled Electrostatic MEMS Resonant Sensor Devices via Blue-Sideband Excitation
This article for the first time introduces the blue-sideband excitation (BSE) scheme to two types of 2-degree-of-freedom (2-DoF) weakly coupled electrostatic resonant sensors, i.e., a 2-DoF electrostatically coupled resonating system with parallel suspension beams (Device 1) and a 2-DoF coupled double-ended tuning fork (DETF) resonant device (Device 2), boosting the functionality of the mode localization phenomena and ultimately achieving distinct performance upgradation. The amplitude ratio (AR) is hence adopted as the readout metric for the sensitivity characterization with respect to different external stiffness perturbations introduced by the capacitive transduction. Three paradigms of AR were implemented in this subject, namely, intermodal AR (IM-AR), interresonator AR (IR-AR), and interresonator-IM-AR (IRIM-AR), owing to the feature of simultaneous multiple-mode excitation of BSE. A comparison regarding the coupled resonant devices subject to the conventional drive scheme and the BSE was conducted, where the experimental results indicated that more than two orders of magnitude enhancement in sensitivity were achieved with the BSE scheme, along with the possibility of a pronounced $\sim$17 times improvement in the noise floor, as well as the capability of simultaneous multiple parameter extraction across different resonators and vibration modes within the coupled system. This work further verified the feasibility and effectiveness of the BSE scheme, demonstrating the potential of such a technique for sensing applications based on mode-localized resonant sensors, fostering ultrahigh performance augmentation.
- Open Access
- 10 October 2024
- Published by Springer Nature in Research Square
Electrostatic anti-spring-enhanced MEMS accelerometer with auto-tuning capability
This paper presents a MEMS accelerometer featuring an auto-tuning system based on an electrostatic anti-spring mechanism. The accelerometer's sensitivity can be automatically adjusted to modify its measurement range and bandwidth in response to varying acceleration inputs. Comprehensive theoretical analysis and experimental validation were performed, demonstrating strong agreement between experimental results and theoretical predictions. As the acceleration input increased, the sensitivity of the MEMS accelerometer with the auto-tuning system increased, while its bandwidth decreased. Furthermore, this new design exhibited significantly higher sensitivity for a given acceleration input compared to the conventional design. Specifically, the sensitivity of the new design at 15.4 V actuation voltage was measured at 39.43 V/g at 0 g acceleration, which is 30.80 times greater than that of the conventional design (1.28 V/g). The spring constant was reduced from its original mechanical value of 41.0 N/m to 1.38 N/m at 0 g acceleration. Additionally, the noise floor and dynamic range of the new design are 279 ng/ √Hz at 100 Hz (30.9 times higher than that of the conventional design) and 157 dB (30 dB higher than that of the conventional design), respectively.
- 10 October 2024
- Published by Springer Nature in Research Square
Open AccessElectrostatic anti-spring-enhanced MEMS accelerometer with auto-tuning capability
This paper presents a MEMS accelerometer featuring an auto-tuning system based on an electrostatic anti-spring mechanism. The accelerometer's sensitivity can be automatically adjusted to modify its measurement range and bandwidth in response to varying acceleration inputs. Comprehensive theoretical analysis and experimental validation were performed, demonstrating strong agreement between experimental results and theoretical predictions. As the acceleration input increased, the sensitivity of the MEMS accelerometer with the auto-tuning system increased, while its bandwidth decreased. Furthermore, this new design exhibited significantly higher sensitivity for a given acceleration input compared to the conventional design. Specifically, the sensitivity of the new design at 15.4 V actuation voltage was measured at 39.43 V/g at 0 g acceleration, which is 30.80 times greater than that of the conventional design (1.28 V/g). The spring constant was reduced from its original mechanical value of 41.0 N/m to 1.38 N/m at 0 g acceleration. Additionally, the noise floor and dynamic range of the new design are 279 ng/ √Hz at 100 Hz (30.9 times higher than that of the conventional design) and 157 dB (30 dB higher than that of the conventional design), respectively.