Latest Publications

  • Open Access

    Two-year outcomes of left bundle branch area pacing versus traditional right ventricular pacing in middle-aged adults: a registry-based trial

    by Matteo Bertini, Luca Canovi, Francesco Vitali, Lina Marcantoni, Gianni Pastore, Mario Volpicelli, Orlando Munciguerra, Mauro Biffi, Matteo Ziacchi, Luca Rossi, et al.

    Aims: Prolonged right ventricular pacing (RVP) increases the risk of cardiomyopathy, atrial fibrillation, heart failure (HF), and mortality. This registry-based trial compared left bundle branch area pacing (LBBAP) with RVP in patients younger than 65 years. Methods and results: Using the ConTempoRary Cardiac Stimulation in Clinical practicE: lEft, BivEntriculAr, Right, and conDuction System Pacing (TREEBEARD) registry (NCT06324682), patients were randomized 1:1 to LBBAP or RVP. The primary endpoint was a composite of cardiovascular (CV) death and HF hospitalization (HFH); secondary endpoints included individual components and all-cause mortality. A total of 344 patients (mean age 58.5 years, 215 males, 172 per arm) were included. At 2 years, the primary composite endpoint occurred in 6.3% of LBBAP vs. 12.7% of RVP patients (HR, 0.78; 95% CI, 0.59–0.87), representing a 22% risk reduction. Subgroup analyses aligned with primary findings. Left bundle branch area pacing significantly reduced HFH risk (HR, 0.79; 95% CI, 0.63–0.86) but showed no difference in CV mortality (HR, 1.02; 95% CI, 0.79–1.32) or all-cause mortality (HR, 1.00; 95% CI, 0.72–1.38). Conclusion: Left bundle branch area pacing significantly lowered the 2-year composite of CV death and HFH compared to RVP in patients aged <65 years old. However, it did not reduce CV or all-cause mortality individually compared to RVP. Clinical Trial Registration: TREEBEARD (NCT06324682)


  • Cardiac arrest and Brugada syndrome: Is drug-induced type 1 ECG pattern always a marker of low risk?

    by Pietro Delise, Giuseppe Allocca, Nadir Sitta, Federico Migliore, Federica Dagradi, Carla Spazzolini, Luigi Sciarra, Valeria Carinci, Domenico Corrado, Leonardo Calò, et al.


  • Use of remote monitoring in the management of ICD end-of-life: Data from the DECODE registry

    by Andrea Campana, Fabrizio Giofrè, Giuseppe Stabile, Matteo Iori, Concetto La Rosa, Corrado Tomasi, Vittorio Calzolari, Gennaro Miracapillo, Pasquale Notarstefano, Valeria Carinci, et al.


  • Open Access

    56-49: Manufacturer change at the time of ICD replacement: Italian survey and data from the DECODE study

    by Mauro Biffi, Endrj Menardi, Gemma Pelargonio, Ernesto Ammendola, Quintino Parisi, Matteo Iori, Concetto La Rosa, Francesco Zanon, Matteo Bertini, Fabio Lissoni, et al.

    Purpose of the study: Development and adoption of technical standards among ICD manufacturers is mandatory. Although the interchangeability of the ICD systems is ensured by established and codified specifications, some barriers seem to exist in changing ICD manufacturer at the time of device replacement. Method used: We analyzed 784 consecutive ICD/CRT-D replacement or upgrading procedures during a 1,5-year time frame in 36 Italian centers in order to evaluate potential factors associated with changing manufacturer. Subsequently, we compared these results with a survey administered to the implanting physicians at the end of the enrolling period. Summary of results: Devices in analysis were 211 single-chamber (SC), 210 dual-chamber ICDs (DC) and 363 CRT-D. A manufacturer change occurred in 191 cases (24%): 72 SC ICDs (34%), 52 DC ICDs (25%) and 67 CRT-D (18%, p < 0.001 vs SC). Replacement-only procedures were associated with a lower rate of manufacturer change than upgrading procedures (23% vs 32%, p = 0.02). In the SC/DC cohort, the reduction in generator volume (GV) was the only variable that favored the manufacturer change (OR, 2.7; 95%CI: 1.6–4.4; P = 0.001), while DC devices were associated with the maintenance of manufacturer (OR, 0.6; 95%CI: 0.4–0.9; P < 0.05). In the CRT-D group, service life below the median value (OR, 2.2; 95%CI: 1.1–4.2; p = 0.02), reduction in GV (OR, 15.3; 95%CI: 6.9–33.9; p < 0.0001) and change from a sharp- to a rounded-shape (OR, 4.7; 95%CI: 2.3–9.7; p < 0.0001) favored the manufacturer change. According to the survey, the reasons to change ICD manufacturer were: higher expected longevity of the new device 26%, remote monitoring 4%, physical characteristics 17%, algorithms/features 15%, administrative reasons in 27%, recall/advisory in 10% and other reasons in 1%. Conclusion: At the time of ICD replacement, manufacturer change occurs in 24% of patients, mainly when the new device presents a more physiological design or the replaced one exhibited a lower than expected longevity. Conversely, it is less likely to occur with CRT-D devices that are equipped with more specific technology and less frequently require addition of features. These findings agree with the physician's opinion captured by the survey.

  • Open Access

    Ablation of Atrial Fibrillation Using a New 8 mm Tip Catheter with 4 Thermocouple Sensors and Basket 31 mm Mapping System

    by G. Barbato, V. Carinci, F. Pergolini, A. Favaro, M. Casanova, G Dipasquale

    In order to treat atrial fibrillation (AF) by radiofrequency (RF) ablation different approaches have been proposed. In this paper we describe our experience in AF ablation using a new multisense 8 mm tip catheter. 24 patients (Pts) mean age 62 years, underwent AF ablation. The procedure end point was PV insulation, superior vena cava (SVC) insulation and right flutter lesion. PV and SVC were mapped using a 31 mm basket catheter with 64 electrodes. The lesions were performed with a new 8 mm tip bi-directional steerable catheter, with 4 thermocouples located in the tip. The system is lead by the sensor that achieves the highest temperature to avoid high temperature on small electrode areas. No complications occurred during the procedures. Complete conduction block in 4 PV was obtained in 20 Pts (83%). During a median follow up of 4 months, only 6 Pts (25%) experienced recurrence of AF. There is some concern in using an 8 mm tip catheter with high voltage setting in the LA because of embolic risk. Using the multisense catheter we never documented thrombus on the electrode (even after high voltage delivery). The catheter manipulation appears to be easier compared to available cooled 4 mm tip catheters.