GMGennaro Miracapillo

Gennaro Miracapillo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gennaro Miracapillo has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Switching to a 100% remote follow‐up of implantable cardiac electronic devices: Organizational model and results of a single center experience

    by Gennaro Miracapillo, Luigi Addonisio, Francesco De Sensi, Paolo Orselli, Elena Piccinetti, Carla Aramini, Ugo Limbruno

    Introduction: During the SARS‐CoV‐2 COVID‐19 pandemic, the global health system needed to review important processes involved in daily routines such as outpatient activities within the hospital, including follow‐up visits of implantable cardiac electronic devices (CIEDs) carried out in office. The aim of this study is to describe our 3.5 years of real‐world experience of a full remote CIED follow‐up, evaluate the success rate of remote transmissions, and verify the adopted organizational model.Methods: From April 2020 to November 2023, all patients with an activated and well‐functioning remote monitoring (RM) system and automatic algorithms, like autocapture and autosensing, underwent exclusive RM follow‐up. Unscheduled in‐office visits were only prompted by remote yellow or red alerts. Patients were divided into two groups, based on available technology: Manual Transmission System (MTS) and Automatic Transmission System (ATS). The ATS group, in addition to ensuring a daily transmission of any yellow or red alerts, was checked at least every 15 days to ensure a valid connection. An automatic transmission was scheduled once a year, irrespective of alerts occurred. The MTS group provided a manual transmission every 6 months.Results: One thousand nine hundred thirty‐seven consecutive patients were included in the study. By the end of November 2023, a total of 1409 patients (1192 in the ATS and 217 in the MTS group) were still actively followed by our remote clinic (384 expired, 137 dismissed, 7 transferred). The overall success rate of transmissions with the adopted organizational model was 96.6% in the ATS group (connection index) and 87% in the MTS group. Conventional in‐hospital follow‐up visits decreased by 44%. Total clinic working time, resulting from the sum of the time spent during in‐hospital and remote follow‐up, after an initial increase, was progressively reduced to the actual −25%. Mortality rate for any cause was 7.5% per year in remote follow‐up patients and 8.3% (p=NS) in in‐office patients. In the ATS group, no device malfunctions were notified to our remote clinic, before we had already realized it through appropriate alerts.Conclusions: The available technology makes moving to a 100% remote clinic possible, without overwhelming clinic workflow, safely. Adopting an appropriate organizational model, it is possible to maintain high transmission success rates. The automatic transmissions allow a more frequent control of patients with CIED.


  • Open Access

    Thromboembolic Events Following Atrial Fibrillation Cardioversion and Ablation: What’s the Culprit?

    by Francesco De Sensi, Gennaro Miracapillo, Luigi Addonisio, Marco Breschi, Alberto Cresti, Pasquale Baratta, Francesco Paneni, Ugo Limbruno

    Stroke is a rare but possible complication after atrial fibrillation (AF) ablation. However, its etiopathogenesis is far from being completely characterized. Here we report a case of stroke, with recurrent peripheral embolism after AF ablation procedure. In our patient, an in situ femoral vein thrombosis and iatrogenic atrial septal defect were simultaneously detected. A comprehensive review of multiple pathophysiological mechanisms of stroke in this context is provided. The case underlines the importance of a global evaluation of patients undergoing AF ablation.

  • Use of remote monitoring in the management of ICD end-of-life: Data from the DECODE registry

    by Andrea Campana, Fabrizio Giofrè, Giuseppe Stabile, Matteo Iori, Concetto La Rosa, Corrado Tomasi, Vittorio Calzolari, Gennaro Miracapillo, Pasquale Notarstefano, Valeria Carinci, et al.


  • Open Access

    56-49: Manufacturer change at the time of ICD replacement: Italian survey and data from the DECODE study

    by Mauro Biffi, Endrj Menardi, Gemma Pelargonio, Ernesto Ammendola, Quintino Parisi, Matteo Iori, Concetto La Rosa, Francesco Zanon, Matteo Bertini, Fabio Lissoni, et al.

    Purpose of the study: Development and adoption of technical standards among ICD manufacturers is mandatory. Although the interchangeability of the ICD systems is ensured by established and codified specifications, some barriers seem to exist in changing ICD manufacturer at the time of device replacement. Method used: We analyzed 784 consecutive ICD/CRT-D replacement or upgrading procedures during a 1,5-year time frame in 36 Italian centers in order to evaluate potential factors associated with changing manufacturer. Subsequently, we compared these results with a survey administered to the implanting physicians at the end of the enrolling period. Summary of results: Devices in analysis were 211 single-chamber (SC), 210 dual-chamber ICDs (DC) and 363 CRT-D. A manufacturer change occurred in 191 cases (24%): 72 SC ICDs (34%), 52 DC ICDs (25%) and 67 CRT-D (18%, p < 0.001 vs SC). Replacement-only procedures were associated with a lower rate of manufacturer change than upgrading procedures (23% vs 32%, p = 0.02). In the SC/DC cohort, the reduction in generator volume (GV) was the only variable that favored the manufacturer change (OR, 2.7; 95%CI: 1.6–4.4; P = 0.001), while DC devices were associated with the maintenance of manufacturer (OR, 0.6; 95%CI: 0.4–0.9; P < 0.05). In the CRT-D group, service life below the median value (OR, 2.2; 95%CI: 1.1–4.2; p = 0.02), reduction in GV (OR, 15.3; 95%CI: 6.9–33.9; p < 0.0001) and change from a sharp- to a rounded-shape (OR, 4.7; 95%CI: 2.3–9.7; p < 0.0001) favored the manufacturer change. According to the survey, the reasons to change ICD manufacturer were: higher expected longevity of the new device 26%, remote monitoring 4%, physical characteristics 17%, algorithms/features 15%, administrative reasons in 27%, recall/advisory in 10% and other reasons in 1%. Conclusion: At the time of ICD replacement, manufacturer change occurs in 24% of patients, mainly when the new device presents a more physiological design or the replaced one exhibited a lower than expected longevity. Conversely, it is less likely to occur with CRT-D devices that are equipped with more specific technology and less frequently require addition of features. These findings agree with the physician's opinion captured by the survey.

  • Left Axillary Implantation of Loop Recorder versus the Traditional Left Chest Area: A Prospective Randomized Study

    by Gennaro Miracapillo, Luigi Addonisio, Marco Breschi, Francesco DE Sensi, Enrico Manfredini, Giorgio Corbucci, Silva Severi, S. Serge Barold

    Background: Based upon the results of a previous small pilot study, we present the results of a prospective single‐center randomized study comparing the performance of the implantable loop recorder (ILR) at two implanting sites.Methods: A group of patients whose ILRs were implanted via a left axillary approach were compared with a group who received an ILR in the traditional left site of the chest. Follow‐up (FU) was scheduled every 6 months or when symptoms occurred. All patients enrolled in the study had a complete FU from implantation to explantation. R‐ and P‐wave amplitudes were measured at implantation and during FU. Explantation of the device was programmed at the end of service life or when ILR analysis resulted in a complete and exhaustive diagnosis.Results: Sixty‐three patients were enrolled (70 ± 12 years, range: 21–92, 59% male): 31 standard and 32 with axillary access. The R‐wave amplitude obtained with the new technique was comparable with that obtained with the standard procedure. The diagnostic accuracy of the ILR was comparable in the two groups. The axillary implantation procedure was slightly longer but no complications were observed.Conclusion: This long‐term randomized study confirmed that axillary access for ILR implantation is feasible, safe, well tolerated, and reliable in terms of device performance. Moreover, it is aesthetically superior to the standard approach and carries the potential of minimizing permanent scarring after ILR extraction.


  • Open Access

    483 Tissue Doppler imaging for long-term optimization of interventricular delay in patients with biventricular pace-maker

    by I. D'Aiello, L. Addonisio, G. Miracapillo, A. Costoli, M. Breschi, F. Guerrini, F. Cesareo, S. Severi