TCTammy Chang

Tammy Chang

*This is an algorithmically generated author record based on publicly available information.

Tammy Chang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Two-Tone Frequency Hopping Waveform for Decentralized Consensus-Based Joint Frequency and Phase Alignment in Distributed Antenna Arrays

    by Mohammed Rashid, William R. Torres, Tammy Chang, Jeffrey A. Nanzer

    Wireless alignment of the frequencies and phases of the antenna elements in a distributed antenna array is necessary to ensure high-gain distributed beamforming, as well as to achieve improved system gain, adaptability, and robustness to failures. However, the increase in the density of wireless systems every year is creating less spectrum availability and more interference for the operation of other wireless technologies. Specifically, such interference can degrade the ability to coordinate the nodes in a distributed array, which must align their electrical states to the wavelength level using wireless connectivity. In this work, we propose to use a spectrally-sparse and frequency-diverse two-tone waveform that hops between different subbands over the broadcast to mitigate the impact of interference on the array synchronization. A decentralized electrical state (frequency and phase) synchronization scheme is proposed in which the two-tone waveform is iteratively broadcasted between the neighboring nodes by modulating the signal onto different carrier frequencies over the iterations, and where the frequency and phase of the local oscillator of each node are encoded in the difference between the frequencies and phases of the individual tones. Nodes implement an iterative average consensus algorithm in which they first recover the states of the neighboring nodes from their observed signals, compute an average of the locally observed values, and then update the difference in frequencies and phases of their two tones to match the average value. This process is repeated iteratively at each node, resulting in synchronizing the array to a small residual phase error within a few iterations. Simulation results are included where the performance of the proposed scheme is analyzed by varying the connectivity of the array, the update interval, and the bandwidth of the two-tone waveform.


  • Open Access

    Physics-Based Inversion of a Millimeter-Wave Diagnostic for Liquid Metal Additive Manufacturing

    by Saptarshi Mukherjee, Tammy Chang, Nicholas N. Watkins, David M. Stobbe

    This article presents a physics-based inversion technique for reliable characterization of droplets deposited by a liquid metal jetting additive manufacturing system, using an in-situ millimeter wave diagnostic. The overall approach is demonstrated in a custom droplet-on-demand liquid metal jetting system with effective droplet diameters ranging from 0.8 to 1.7 mm. The inversion results demonstrate that this approach can provide information about the droplet size and lift-off distance between the droplet and the diagnostic by monitoring the amplitude and phase of the reflection coefficient at the input port.

  • Open Access

    Millimeter-wave electromagnetic monitoring for liquid metal droplet-on-demand printing

    by T. Chang, S. Mukherjee, N. N. Watkins, E. Benavidez, A. M. Gilmore, A. J. Pascall, D. M. Stobbe

    As new printing approaches emerge, in situ diagnostics to monitor the print quality in real-time become essential for long-term monitoring and feedback control. In this article, we present a millimeter-wave electromagnetic monitoring approach for liquid metal droplet-on-demand printing to support the high-speed and real-time evaluation of droplet ejection. An open-ended rectangular waveguide is placed perpendicular to a jetted droplet stream and operated at a continuous-wave frequency of 40 GHz. Liquid metal droplets with diameters as low as 1.2 mm are characterized, and droplet jetting events on the order of 500 μ m are detected at ejection rates up to 80 Hz. The measured results demonstrate that trends at the macro-level (large-scale print variation and anomalies at the nozzle tip) as well as micro-level (droplet size, position, and dynamics) can be detected using this technique.


  • Open Access

    In-situ monitoring for liquid metal jetting using a millimeter-wave impedance diagnostic

    by Tammy Chang, Saptarshi Mukherjee, Nicholas N. Watkins, David M. Stobbe, Owen Mays, Emer V. Baluyot, Andrew J. Pascall, Joseph W. Tringe

    This article presents a millimeter-wave diagnostic for the in-situ monitoring of liquid metal jetting additive manufacturing systems. The diagnostic leverages a T-junction waveguide device to monitor impedance changes due to jetted metal droplets in real time. An analytical formulation for the time-domain T-junction operation is presented and supported with a quasi-static full-wave electromagnetic simulation model. The approach is evaluated experimentally with metallic spheres of known diameters ranging from 0.79 to 3.18 mm. It is then demonstrated in a custom drop-on-demand liquid metal jetting system where effective droplet diameters ranging from 0.8 to 1.6 mm are detected. Experimental results demonstrate that this approach can provide information about droplet size, timing, and motion by monitoring a single parameter, the reflection coefficient amplitude at the input port. These results show the promise of the impedance diagnostic as a reliable in-situ characterization method for metal droplets in an advanced manufacturing system.