Fengcheng Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fengcheng Huang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Wenjie Zhang
School of Energy and Power Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
2 shared publications - Changqing Lin
School of Civil Engineering, Chongqing University, Chongqing 400044, China
1 shared publication - Jiajun Zhang
China Unicom Consulting Design Research Institute Co., Ltd., Nanjing 210019, China
1 shared publication - Kai Mao
Research Institute of Standards and Norms Ministry of Housing and Urban-Rural Development, Beijing 100835, China
1 shared publication - Yongheng Zhong
School of Energy and Power Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
1 shared publication - Yuqiang Zhao
School of Energy and Power Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
1 shared publication
Latest Publications
- Open Access
Evaluation of Photovoltaic Energy Saving Potential and Investment Value of Urban Buildings in China Based on GIS Technology
The environmental and energy crisis has become a problem that can not be ignored in today’s world and improving the proportion of renewable energy utilization is an important way to alleviate the problem. China has begun to vigorously develop rooftop photovoltaic systems, and it is urgent to analyze the photovoltaic potential of the country. In this paper, GIS technology is used to calculate the available area of a PV system on the roof of urban buildings in China. The installed capacity and annual power generation of a PV system on the roof of urban buildings in China are further calculated, and the investment cost analysis of the buildings with a PV system is carried out. The results show that Chinese mainland city rooftop photovoltaic area has reached 3.35 billion m2. If urban roofs are used for photovoltaic power generation in China, the annual photovoltaic power generation capacity will be 672 billion kWh, which is about 61% of the total annual electricity consumption of the whole society in 2020. On the other hand, the initial investment in the construction of an urban photovoltaic system is large, but most of them can realize the return of investment in a short period of 8–10 years. Moreover, in the effective life of the follow-up photovoltaic system, it will bring greater economic benefits, which is more than two times the initial investment. To further promote the process of social carbon peak and carbon neutrality in China, the construction of an urban photovoltaic system is very feasible.
Open AccessEvaluation of Photovoltaic Energy Saving Potential and Investment Value of Urban Buildings in China Based on GIS Technology
The environmental and energy crisis has become a problem that can not be ignored in today’s world and improving the proportion of renewable energy utilization is an important way to alleviate the problem. China has begun to vigorously develop rooftop photovoltaic systems, and it is urgent to analyze the photovoltaic potential of the country. In this paper, GIS technology is used to calculate the available area of a PV system on the roof of urban buildings in China. The installed capacity and annual power generation of a PV system on the roof of urban buildings in China are further calculated, and the investment cost analysis of the buildings with a PV system is carried out. The results show that Chinese mainland city rooftop photovoltaic area has reached 3.35 billion m2. If urban roofs are used for photovoltaic power generation in China, the annual photovoltaic power generation capacity will be 672 billion kWh, which is about 61% of the total annual electricity consumption of the whole society in 2020. On the other hand, the initial investment in the construction of an urban photovoltaic system is large, but most of them can realize the return of investment in a short period of 8–10 years. Moreover, in the effective life of the follow-up photovoltaic system, it will bring greater economic benefits, which is more than two times the initial investment. To further promote the process of social carbon peak and carbon neutrality in China, the construction of an urban photovoltaic system is very feasible.
- Open Access
Study of the Application Characteristics of Photovoltaic-Thermoelectric Radiant Windows
Through experiments and numerical simulation, this paper studies the related performance of a photovoltaic thermoelectric radiation cooling window structure, verifies the accuracy of the established solar thermoelectric radiation window calculation model, and analyzes the cooling performance of different parameters of thermoelectric sheet, radiation plate, and photovoltaic panel. On the basis of considering the relationship between the power generation and power consumption of the structure, the numerical calculation results show that the solar thermoelectric radiation window with non-transparent photovoltaic module (NTPV) has a total cooling capacity of 50.2 kWh, power consumption of 71.8 kWh, and power generation of 83.9 kWh from June to August. The solar thermoelectric radiation window with translucent photovoltaic module (STPV) has a total cooling capacity of 50.7 kWh, power consumption of 71.7 kWh, and power generation of 45.4 kWh from June to August. If the operation time of the thermoelectric module is limited, when the daily operation time of TEM is less than 8 h, the power generation of STPV can meet the power consumption demand of the thermoelectric radiation window from June to August.
Open AccessStudy of the Application Characteristics of Photovoltaic-Thermoelectric Radiant Windows
Through experiments and numerical simulation, this paper studies the related performance of a photovoltaic thermoelectric radiation cooling window structure, verifies the accuracy of the established solar thermoelectric radiation window calculation model, and analyzes the cooling performance of different parameters of thermoelectric sheet, radiation plate, and photovoltaic panel. On the basis of considering the relationship between the power generation and power consumption of the structure, the numerical calculation results show that the solar thermoelectric radiation window with non-transparent photovoltaic module (NTPV) has a total cooling capacity of 50.2 kWh, power consumption of 71.8 kWh, and power generation of 83.9 kWh from June to August. The solar thermoelectric radiation window with translucent photovoltaic module (STPV) has a total cooling capacity of 50.7 kWh, power consumption of 71.7 kWh, and power generation of 45.4 kWh from June to August. If the operation time of the thermoelectric module is limited, when the daily operation time of TEM is less than 8 h, the power generation of STPV can meet the power consumption demand of the thermoelectric radiation window from June to August.