Mingyang Zhang
Research Subjects
Mingyang Zhang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Bing Zhang
School of Transportation and Logistics, East China Jiaotong University, Nanchang 330013, China
1 shared publication - Hong Huang
State Key Laboratory of Performance Monitoring and Protecting of Rail Transit Infrastructures, Nanchang 330013, China
1 shared publication - Kaicheng Xu
State Key Laboratory of Performance Monitoring and Protecting of Rail Transit Infrastructures, Nanchang 330013, China
1 shared publication - Mengcheng Chen
State Key Laboratory of Performance Monitoring and Protecting of Rail Transit Infrastructures, Nanchang 330013, China
1 shared publication - Qingqing Wen
State Key Laboratory of Performance Monitoring and Protecting of Rail Transit Infrastructures, Nanchang 330013, China
1 shared publication - Tao Wang
School of Civil Engineering and Architecture, East China Jiaotong University, Nanchang 330013, China
1 shared publication
Latest Publications
- Open Access
Experimental and Numerical Investigation on the Ultimate Bearing Capacity of Axially Compressed Steel Tube Columns with Local Corrosion
In this paper, 17 types of circular, hollow steel tube columns were designed for the axial compression test. A defect was corroded with an acid rain spray method. The effects of the geometric spatial location of local corrosion zones, three-dimensional size, shape, and number of local corrosion zones on the axial compression load-bearing capacity of the circular hollow steel columns were investigated. Through model verification and parameter analysis in the finite element software ABAQUS, a finite element model of 136 local corrosion, hollow steel tube columns under axial compression was established. In conjunction with experimental and numerical analysis, the primary factor influencing the load-bearing capacity of the steel tube columns was the decrease in effective cross-sectional zones at the corroded zones. Single or multiple local corrosion zones of the same size distributed along the length of the column can reduce the load-bearing capacity of steel tube columns. However, the number, location, and distribution of corrosion zones with the same size have similar degrees of influence on the load-bearing capacity of the steel tube column, with no significant differences. In the case of the same corrosion ratio η, the load-bearing capacity of steel tube column exhibits a linear relationship with the increase in both the radial corrosion thickness and the circumferential corrosion width within the locally corroded zone. The axial corrosion length in the corroded region has little effect on the load-bearing capacity of the steel tube columns. Ranking the effect of corrosion parameters on the axial compression bearing capacity under the same corrosion ratio η, the largest one is the radial corrosion thickness; the next are the circumferential corrosion width and the axial corrosion length. A practical formula was developed to calculate the load-bearing capacity of locally corroded steel tube columns, using the rate of section loss in the corroded region as the dependent variable. The formula accurately calculates the axial compressive load-bearing capacity of locally corroded steel tube columns and provides valuable reference for evaluating and maintaining steel tube structures.
Open AccessExperimental and Numerical Investigation on the Ultimate Bearing Capacity of Axially Compressed Steel Tube Columns with Local Corrosion
In this paper, 17 types of circular, hollow steel tube columns were designed for the axial compression test. A defect was corroded with an acid rain spray method. The effects of the geometric spatial location of local corrosion zones, three-dimensional size, shape, and number of local corrosion zones on the axial compression load-bearing capacity of the circular hollow steel columns were investigated. Through model verification and parameter analysis in the finite element software ABAQUS, a finite element model of 136 local corrosion, hollow steel tube columns under axial compression was established. In conjunction with experimental and numerical analysis, the primary factor influencing the load-bearing capacity of the steel tube columns was the decrease in effective cross-sectional zones at the corroded zones. Single or multiple local corrosion zones of the same size distributed along the length of the column can reduce the load-bearing capacity of steel tube columns. However, the number, location, and distribution of corrosion zones with the same size have similar degrees of influence on the load-bearing capacity of the steel tube column, with no significant differences. In the case of the same corrosion ratio η, the load-bearing capacity of steel tube column exhibits a linear relationship with the increase in both the radial corrosion thickness and the circumferential corrosion width within the locally corroded zone. The axial corrosion length in the corroded region has little effect on the load-bearing capacity of the steel tube columns. Ranking the effect of corrosion parameters on the axial compression bearing capacity under the same corrosion ratio η, the largest one is the radial corrosion thickness; the next are the circumferential corrosion width and the axial corrosion length. A practical formula was developed to calculate the load-bearing capacity of locally corroded steel tube columns, using the rate of section loss in the corroded region as the dependent variable. The formula accurately calculates the axial compressive load-bearing capacity of locally corroded steel tube columns and provides valuable reference for evaluating and maintaining steel tube structures.
- Open Access
- 15 October 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (20) , 11418
Two-Level Planning of Customized Bus Routes Based on Uncertainty Theory
The optimization problem of customized bus routes is affected by uncertain factors in reality; therefore, this paper introduces uncertainty theory to study the above problem. A two-level planning model that takes the maximum total revenue of the bus company as the upper-level goal and the minimum total travel cost of passengers as the lower-level goal is established, using uncertainty theory to study and solve practical problems with uncertain factors. The genetic algorithm is used to solve the model, and the feasibility of the model is verified through a case study. The research results show that the application of the two-level model of customized bus route planning based on uncertain vehicle operating time established in this paper to customize bus route planning can take into account the travel needs of passengers and high-quality experiences while also bringing benefits to enterprises and achieving a win–win situation. The research in this article provides theoretical support for the optimization of customized bus routes.
- 15 October 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (20) , 11418
Open AccessTwo-Level Planning of Customized Bus Routes Based on Uncertainty Theory
The optimization problem of customized bus routes is affected by uncertain factors in reality; therefore, this paper introduces uncertainty theory to study the above problem. A two-level planning model that takes the maximum total revenue of the bus company as the upper-level goal and the minimum total travel cost of passengers as the lower-level goal is established, using uncertainty theory to study and solve practical problems with uncertain factors. The genetic algorithm is used to solve the model, and the feasibility of the model is verified through a case study. The research results show that the application of the two-level model of customized bus route planning based on uncertain vehicle operating time established in this paper to customize bus route planning can take into account the travel needs of passengers and high-quality experiences while also bringing benefits to enterprises and achieving a win–win situation. The research in this article provides theoretical support for the optimization of customized bus routes.