HHHong Huang

Hong Huang

*This is an algorithmically generated author record based on publicly available information.

Hong Huang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Durability Life Assessment of Prestressed Concrete Box-Girder Bridges Considering Chloride Ingress and Carbonation Process Under Realistic Climate

    by Mengcheng Chen, Siyuan Huang, Wei Fang, Kaicheng Xu, Hong Huang

    Harsh environmental conditions (de-icing salts, CO 2 emissions, freeze–thaw, etc.) in northern China threaten the durability of reinforced concrete (RC) highway bridges, with carbonation and chloride ingress acting synergistically. This paper presents an integrated COMSOL framework that couples nonlinear PDEs for heat, moisture, chloride, and CO 2 transport, where carbonation’s effect on chloride diffusion is quantified by the reduction in bound chlorides. The framework is validated against eight-year field data from an in-service prestressed concrete box-girder bridge, showing good agreement (max error ~ 16%). Latin Hypercube Sampling is used for probabilistic reliability-based durability life prediction. The critical vulnerable zone is located at the web–bottom slab intersection of the mid-span section, where the chloride concentration and carbonation depth are at least 1.5 times the corresponding values at the center of the bottom slab. Including the synergistic effect reduces the predicted service life to 81.1 years, compared to carbonation‑ignored scenarios. This framework provides a robust tool for assessing durability under realistic multi‑field coupling.

  • Open Access

    Experimental and Numerical Investigation on the Ultimate Bearing Capacity of Axially Compressed Steel Tube Columns with Local Corrosion

    by Wei Fang, Tao Wang, Mengcheng Chen, Mingyang Zhang, Hong Huang, Kaicheng Xu, Qingqing Wen

    In this paper, 17 types of circular, hollow steel tube columns were designed for the axial compression test. A defect was corroded with an acid rain spray method. The effects of the geometric spatial location of local corrosion zones, three-dimensional size, shape, and number of local corrosion zones on the axial compression load-bearing capacity of the circular hollow steel columns were investigated. Through model verification and parameter analysis in the finite element software ABAQUS, a finite element model of 136 local corrosion, hollow steel tube columns under axial compression was established. In conjunction with experimental and numerical analysis, the primary factor influencing the load-bearing capacity of the steel tube columns was the decrease in effective cross-sectional zones at the corroded zones. Single or multiple local corrosion zones of the same size distributed along the length of the column can reduce the load-bearing capacity of steel tube columns. However, the number, location, and distribution of corrosion zones with the same size have similar degrees of influence on the load-bearing capacity of the steel tube column, with no significant differences. In the case of the same corrosion ratio η, the load-bearing capacity of steel tube column exhibits a linear relationship with the increase in both the radial corrosion thickness and the circumferential corrosion width within the locally corroded zone. The axial corrosion length in the corroded region has little effect on the load-bearing capacity of the steel tube columns. Ranking the effect of corrosion parameters on the axial compression bearing capacity under the same corrosion ratio η, the largest one is the radial corrosion thickness; the next are the circumferential corrosion width and the axial corrosion length. A practical formula was developed to calculate the load-bearing capacity of locally corroded steel tube columns, using the rate of section loss in the corroded region as the dependent variable. The formula accurately calculates the axial compressive load-bearing capacity of locally corroded steel tube columns and provides valuable reference for evaluating and maintaining steel tube structures.


  • Open Access

    Experimental and Numerical Investigation on the Bearing Capacity of Axially Compressive Concrete-Filled Steel Tubular Columns with Local Corrosion

    by Wei Fang, Mengcheng Chen, Qingqing Wen, Hong Huang, Kaicheng Xu, Rui Zhang

    This study aims to examine the effects of local corrosion on the axial compression performance of concrete-filled steel tubular (CFST) members. Nineteen CFST short columns with local corrosion were designed and fabricated to undergo axial compression mechanical property tests, with the radial corrosion depth of the local corrosion area as the key test parameter. The failure mechanism and mechanical property change laws of CFST axial compression short columns with circumferential full corrosion at the ends and middle were studied. Combined with finite element modeling, the influence laws of the three-dimensional geometrical characteristics of the local corrosion zone, i.e., the axial length, the annular width and the radial depth, on the structural bearing performance were thoroughly explored and discussed. The results revealed that the main reason for the reduction in load-carrying capacity of circular CFST axial columns due to local corrosion is attributed to the reduction of the effective cross-sectional area of the steel tube in the corrosion area. When local corrosion occurs at different axial positions, the variation range of the bearing capacity of CFST columns is within 10%. Regarding the impact of the three dimensions of local corrosion on the axial load-carrying capacity of CFST, the radial corrosion depth was identified as the most influential factor, followed by the annular corrosion width, and finally by the axial corrosion length. When the axial corrosion length exceeds 20% of the specimen length, its further influence on the load-carrying capacity is considered limited. Finally, a practical calculation formula for the bearing capacity of locally corroded CFST columns is proposed. The predicted results of this formula fit well with the test results and can quickly estimate the remaining bearing capacity of the structure by measuring the geometric parameters of the local corrosion area, providing a reference for the assessment and maintenance of CFST structures.