John Kennedy
Research Subjects
John Kennedy has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Anatole Besarab
Department of Medicine, Division of Nephrology Stanford University School of Medicine Stanford California USA
1 shared publication- Brad C. Astor
Division of Nephrology, Department of Medicine, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
1 shared publication - Gerard Zasuwa
Nephrology Department of Henry Ford Health, Detroit, Michigan
1 shared publication Jerry Yee
Nephrology Department of Henry Ford Health, Detroit, Michigan
1 shared publication- Karla D. Passalacqua
Graduate Medical Education, Henry Ford Health System, Detroit, MI, USA
1 shared publication Kim Hirschman
Vasc‐Alert, LLC Lafayette Indiana USA
1 shared publication
Latest Publications
- Open Access
- 24 March 2023
- Published by Wolters Kluwer Health in Kidney360
- Vol. 4 (4) , e476-e485
Detection of Hemodialysis Venous Needle Dislodgment Using Venous Access Pressure Measurements: A Simulation Study
Key Points: Hemodialysis machine pressure alarms may not detect venous needle dislodgment when patients have changes in venous pressure. A cross-sectional analysis of hemodialysis treatment data identified the occurrences of venous pressure changes that would make it hard to trigger a machine alarm. A proof-of-concept use of a data analytic–derived algorithm for the detection of venous needle dislodgments was demonstrated. Background: In rare instances, hemodialysis venous needles may become dislodged, and when left undetected, this can lead to severe injury or death. Although dialysis machines have alarms to detect venous needle dislodgment (VND), their range of detection is limited. An understanding of the clinical conditions that may lead to missed needle dislodgments is needed for the development of more robust detection systems. Methods: We created a sham dialysis circuit with a Fresenius 2008K dialysis machine for in vitro simulation testing of machine alarm behavior under variable conditions. The circuit used a blood substitute and mimicked a patient's venous access site. We varied blood flow rate, venous pressure (VP), and upward drift in VP and analyzed the time to alarm for the machine and an improved alarm algorithm. We also performed a cross-sectional retrospective study to identify the clinical occurrence of VP upward drift between September 1, 2016, and November 1, 2016, in patients on hemodialysis with an arteriovenous fistula. Results: Of 43,390 VP readings for 147 patients on hemodialysis, 16,594 (38%) showed an upward drift in VP (range 20–79 mmHg), with a mean±SD increase of 11±18 mm Hg within 20±14 minutes. A total of 19 VND simulations under different VP and blood flow parameters resulted in 19 (100%) algorithm alarm activations. Only eight simulations (42%) activated a machine alarm, and machine alarm activation time was longer than the algorithm activation time for all eight machine alarms (range 1–13 seconds). Conclusions: Patients can experience changes in VP during hemodialysis which may not trigger a machine alarm in the case of a VND. Our simulations showed that current dialysis machine alarm systems may not compensate for upward drift in VP, and improved algorithms for detecting needle dislodgment during hemodialysis are needed.
- 24 March 2023
- Published by Wolters Kluwer Health in Kidney360
- Vol. 4 (4) , e476-e485
Open AccessDetection of Hemodialysis Venous Needle Dislodgment Using Venous Access Pressure Measurements: A Simulation Study
Key Points: Hemodialysis machine pressure alarms may not detect venous needle dislodgment when patients have changes in venous pressure. A cross-sectional analysis of hemodialysis treatment data identified the occurrences of venous pressure changes that would make it hard to trigger a machine alarm. A proof-of-concept use of a data analytic–derived algorithm for the detection of venous needle dislodgments was demonstrated. Background: In rare instances, hemodialysis venous needles may become dislodged, and when left undetected, this can lead to severe injury or death. Although dialysis machines have alarms to detect venous needle dislodgment (VND), their range of detection is limited. An understanding of the clinical conditions that may lead to missed needle dislodgments is needed for the development of more robust detection systems. Methods: We created a sham dialysis circuit with a Fresenius 2008K dialysis machine for in vitro simulation testing of machine alarm behavior under variable conditions. The circuit used a blood substitute and mimicked a patient's venous access site. We varied blood flow rate, venous pressure (VP), and upward drift in VP and analyzed the time to alarm for the machine and an improved alarm algorithm. We also performed a cross-sectional retrospective study to identify the clinical occurrence of VP upward drift between September 1, 2016, and November 1, 2016, in patients on hemodialysis with an arteriovenous fistula. Results: Of 43,390 VP readings for 147 patients on hemodialysis, 16,594 (38%) showed an upward drift in VP (range 20–79 mmHg), with a mean±SD increase of 11±18 mm Hg within 20±14 minutes. A total of 19 VND simulations under different VP and blood flow parameters resulted in 19 (100%) algorithm alarm activations. Only eight simulations (42%) activated a machine alarm, and machine alarm activation time was longer than the algorithm activation time for all eight machine alarms (range 1–13 seconds). Conclusions: Patients can experience changes in VP during hemodialysis which may not trigger a machine alarm in the case of a VND. Our simulations showed that current dialysis machine alarm systems may not compensate for upward drift in VP, and improved algorithms for detecting needle dislodgment during hemodialysis are needed.
- Open Access
- 12 October 2021
- Published by Wiley in Seminars in Dialysis
- Vol. 35 (3) , 236-244
Development and validation of a risk score to prioritize patients for evaluation of access stenosis
Background: Access flow dysfunction, often associated with stenosis, is a common problem in hemodialysis access and may result in progression to thrombosis. Timely identification of accesses in need of evaluation is critical to preserving a functioning access. We hypothesized that a risk score using measurements obtained from the Vasc‐Alert surveillance device could be used to predict subsequent interventions.Methods: Measurement of five factors over the preceding 28 days from 1.46 million hemodialysis treatments (6163 patients) were used to develop a score associated with interventions over the subsequent 60 days. The score was validated in a separate dataset of 298,620 treatments (2641 patients).Results: Interventions in arteriovenous fistulae (AVF; n = 4125) were much more common in those with the highest score (36.2%) than in those with the lowest score (11.0). The score also was strongly associated with interventions in patients with an arteriovenous graft (AVG; n = 2,038; 43.2% vs. 21.1%). There was excellent agreement in the Validation datasets for AVF (OR = 2.67 comparing the highest to lowest score) and good agreement for AVG (OR = 1.92).Conclusions: This simple risk score based on surveillance data may be useful for prioritizing patients for physical examination and potentially early referral for intervention.
- 12 October 2021
- Published by Wiley in Seminars in Dialysis
- Vol. 35 (3) , 236-244
Open AccessDevelopment and validation of a risk score to prioritize patients for evaluation of access stenosis
Background: Access flow dysfunction, often associated with stenosis, is a common problem in hemodialysis access and may result in progression to thrombosis. Timely identification of accesses in need of evaluation is critical to preserving a functioning access. We hypothesized that a risk score using measurements obtained from the Vasc‐Alert surveillance device could be used to predict subsequent interventions.Methods: Measurement of five factors over the preceding 28 days from 1.46 million hemodialysis treatments (6163 patients) were used to develop a score associated with interventions over the subsequent 60 days. The score was validated in a separate dataset of 298,620 treatments (2641 patients).Results: Interventions in arteriovenous fistulae (AVF; n = 4125) were much more common in those with the highest score (36.2%) than in those with the lowest score (11.0). The score also was strongly associated with interventions in patients with an arteriovenous graft (AVG; n = 2,038; 43.2% vs. 21.1%). There was excellent agreement in the Validation datasets for AVF (OR = 2.67 comparing the highest to lowest score) and good agreement for AVG (OR = 1.92).Conclusions: This simple risk score based on surveillance data may be useful for prioritizing patients for physical examination and potentially early referral for intervention.