Sarah J. Offutt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sarah J. Offutt has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Lisa Jungbauer Nikolas
Medtronic Pelvic Health Minneapolis Minnesota USA
3 shared publications - Katie C. Bittner
Medtronic Pelvic Health, Minneapolis, MN, USA
2 shared publications Lance Zirpel
Pelvic Health, Medtronic, Minneapolis, MN, 55432, USA
2 shared publicationsAnagha Kotkar
Biomedical Engineering Department, University of Michigan, Ann Arbor, MI, USA
1 shared publication- Anne E. Miller
Medtronic Pelvic Health, Minneapolis, MN, USA
1 shared publication Anne G. Sammarco
University Hospitals Cleveland Ohio USA
1 shared publication
Latest Publications
- Open Access
- 25 September 2026
- Published by Wiley in Neurourology and Urodynamics
Sensing in Sacral Neuromodulation: Objective, Individualized Stimulation Response Thresholds Directly From the Lead
Objectives: Sacral neuromodulation (SNM) therapy today relies on visually observed motor responses (e.g., anal bellows contraction, toe flexion) and subjective patient feedback (pelvic region sensations) to optimize lead placement and perform device programming. Measures of sacral nerve activation used in current practice include motor and sensory thresholds, described as the stimulation amplitudes associated with first observed or reported stimulation responses. This study evaluated the utility of sacral evoked responses (SERs), recorded directly from implanted commercial SNM leads, as objective indicators of sacral nerve activation. Materials and Methods: The PEER 2 Cohort 1 study was a multi‐center, prospective, clinical feasibility study in female overactive bladder patients undergoing a tined lead evaluation for SNM using InterStim™ SureScan™ MRI leads. An investigational external neurostimulator was used to collect electrophysiological signal recordings directly from the implanted lead (SER recordings), in addition to motor and sensory thresholds at three timepoints: intraoperatively (OR), immediately postoperatively (PO), and at the end of therapy evaluation (Trial End). SER recordings were processed to determine stimulation amplitudes associated with first detectable signal (SER threshold, SERT) and analyzed for comparison with the motor and sensory thresholds. Results: Lead‐recorded SERs were reliably detected across subjects and timepoints: OR: 100% (89/89 subjects); PO 98.9% (87/88 subjects); Trial End: 97.7% (86/88 subjects). SERTs demonstrated statistically significant correlation with both motor and sensory thresholds across six bipolar electrode configurations ( R = 0.46–0.92; p < 0.001). Compared to sensory thresholds, SERTs were a more sensitive measure of sacral nerve activation, detected at or below sensory thresholds in 57%–84% of subjects. SERTs also exhibited less variability across repeated measurements compared to sensory thresholds ( p < 0.001). Replicate SERTs showed no change in 55.9% of subjects, whereas sensory thresholds showed no change in only 20.6% of subjects. Conclusions: The study results demonstrate that SERs recorded from SNM leads are reliably detected , clinically relevant , sensitive , and consistent markers of sacral nerve activation, offering an objective alternative to present‐day subjective measures . Integrating lead‐sensed SERs may streamline SNM programming and lead placement, introducing a simplified and standardized measure for optimizing and delivering patient‐specific SNM therapy. Clinical Trial Registration: ClinicalTrials.gov NCT05200923. Investigational device. Limited by Federal (U.S.) law to investigational use. The research system and sensing feature are not approved by the FDA or any other regulatory authority and are not for sale in the US or internationally.
- 25 September 2026
- Published by Wiley in Neurourology and Urodynamics
Open AccessSensing in Sacral Neuromodulation: Objective, Individualized Stimulation Response Thresholds Directly From the Lead
Objectives: Sacral neuromodulation (SNM) therapy today relies on visually observed motor responses (e.g., anal bellows contraction, toe flexion) and subjective patient feedback (pelvic region sensations) to optimize lead placement and perform device programming. Measures of sacral nerve activation used in current practice include motor and sensory thresholds, described as the stimulation amplitudes associated with first observed or reported stimulation responses. This study evaluated the utility of sacral evoked responses (SERs), recorded directly from implanted commercial SNM leads, as objective indicators of sacral nerve activation. Materials and Methods: The PEER 2 Cohort 1 study was a multi‐center, prospective, clinical feasibility study in female overactive bladder patients undergoing a tined lead evaluation for SNM using InterStim™ SureScan™ MRI leads. An investigational external neurostimulator was used to collect electrophysiological signal recordings directly from the implanted lead (SER recordings), in addition to motor and sensory thresholds at three timepoints: intraoperatively (OR), immediately postoperatively (PO), and at the end of therapy evaluation (Trial End). SER recordings were processed to determine stimulation amplitudes associated with first detectable signal (SER threshold, SERT) and analyzed for comparison with the motor and sensory thresholds. Results: Lead‐recorded SERs were reliably detected across subjects and timepoints: OR: 100% (89/89 subjects); PO 98.9% (87/88 subjects); Trial End: 97.7% (86/88 subjects). SERTs demonstrated statistically significant correlation with both motor and sensory thresholds across six bipolar electrode configurations ( R = 0.46–0.92; p < 0.001). Compared to sensory thresholds, SERTs were a more sensitive measure of sacral nerve activation, detected at or below sensory thresholds in 57%–84% of subjects. SERTs also exhibited less variability across repeated measurements compared to sensory thresholds ( p < 0.001). Replicate SERTs showed no change in 55.9% of subjects, whereas sensory thresholds showed no change in only 20.6% of subjects. Conclusions: The study results demonstrate that SERs recorded from SNM leads are reliably detected , clinically relevant , sensitive , and consistent markers of sacral nerve activation, offering an objective alternative to present‐day subjective measures . Integrating lead‐sensed SERs may streamline SNM programming and lead placement, introducing a simplified and standardized measure for optimizing and delivering patient‐specific SNM therapy. Clinical Trial Registration: ClinicalTrials.gov NCT05200923. Investigational device. Limited by Federal (U.S.) law to investigational use. The research system and sensing feature are not approved by the FDA or any other regulatory authority and are not for sale in the US or internationally.
- Open Access
Non-continuous neuromodulation in awake, unrestrained felines increases bladder capacity
Objective Neuromodulation is a standard therapy for bladder symptoms such as overactive bladder. Previous studies have demonstrated that non-continuous stimulation can increase bladder capacity, and that bladder pressure can be estimated from dorsal root ganglia (DRG) neural activity in anesthetized animal models. Our goal is to determine if non-continuous neuromodulation elicits similar bladder capacity effects as continuous neuromodulation and if bladder pressure can be estimated from DRG signals in an awake, unrestrained animal model. Approach We performed aseptic, chronic implant surgeries with seven adult, male felines. Three animals were used to establish procedures, three for experimental testing, and one did not yield data. Bipolar stimulating electrodes were placed on the ipsilateral pudendal nerve and sacral nerve. Microelectrode arrays were inserted in two ipsilateral sacral DRG. Two single-lumen catheters were implanted in the bladder dome for recording bladder pressure and infusing saline. Fixed-sequence, repeated bladder fills were performed in three awake test felines to evaluate the bladder capacity during no-stimulation, non-continuous stimulation, and continuous stimulation at either the pudendal or sacral nerve. Non-continuous stimulation was performed based on increases in bladder pressure estimated from DRG recordings or when 50% of the average no-stimulation bladder capacity was reached. Main results We observed similar bladder capacity increases for non-continuous stimulation (122 ± 32% of no-stimulation control) as for continuous stimulation (121 ± 33%) in the three test animals. Non-continuous stimulation paradigms reduced stimulation time by 44% on average. Median correlation coefficients of 0.46 and 0.64 (maximum 0.93) between neural activity and bladder pressure were obtained for awake trials with bladder units in two animals. Significance This study demonstrated the feasibility of using non-continuous neuromodulation to increase bladder capacity in awake, unrestrained felines and for decoding bladder pressure from DRG recordings. Further studies are needed to optimize non-continuous stimulation timing for clinical translation.
Open AccessNon-continuous neuromodulation in awake, unrestrained felines increases bladder capacity
Objective Neuromodulation is a standard therapy for bladder symptoms such as overactive bladder. Previous studies have demonstrated that non-continuous stimulation can increase bladder capacity, and that bladder pressure can be estimated from dorsal root ganglia (DRG) neural activity in anesthetized animal models. Our goal is to determine if non-continuous neuromodulation elicits similar bladder capacity effects as continuous neuromodulation and if bladder pressure can be estimated from DRG signals in an awake, unrestrained animal model. Approach We performed aseptic, chronic implant surgeries with seven adult, male felines. Three animals were used to establish procedures, three for experimental testing, and one did not yield data. Bipolar stimulating electrodes were placed on the ipsilateral pudendal nerve and sacral nerve. Microelectrode arrays were inserted in two ipsilateral sacral DRG. Two single-lumen catheters were implanted in the bladder dome for recording bladder pressure and infusing saline. Fixed-sequence, repeated bladder fills were performed in three awake test felines to evaluate the bladder capacity during no-stimulation, non-continuous stimulation, and continuous stimulation at either the pudendal or sacral nerve. Non-continuous stimulation was performed based on increases in bladder pressure estimated from DRG recordings or when 50% of the average no-stimulation bladder capacity was reached. Main results We observed similar bladder capacity increases for non-continuous stimulation (122 ± 32% of no-stimulation control) as for continuous stimulation (121 ± 33%) in the three test animals. Non-continuous stimulation paradigms reduced stimulation time by 44% on average. Median correlation coefficients of 0.46 and 0.64 (maximum 0.93) between neural activity and bladder pressure were obtained for awake trials with bladder units in two animals. Significance This study demonstrated the feasibility of using non-continuous neuromodulation to increase bladder capacity in awake, unrestrained felines and for decoding bladder pressure from DRG recordings. Further studies are needed to optimize non-continuous stimulation timing for clinical translation.
- Open Access
- 7 December 2023
- Published by Wiley in Neurogastroenterology & Motility
- Vol. 36 (2) , e14723
Translation of an existing implantable cardiac monitoring device for measurement of gastric electrical slow‐wave activity
Background: Despite evidence that slow‐wave dysrhythmia in the stomach is associated with clinical conditions such as gastroparesis and functional dyspepsia, there is still no widely available device for long‐term monitoring of gastric electrical signals. Actionable biomarkers of gastrointestinal health are critically needed, and an implantable slow‐wave monitoring device could aid in the establishment of causal relationships between symptoms and gastric electrophysiology. Recent developments in the area of wireless implantable gastric monitors demonstrate potential, but additional work and validation are required before this potential can be realized.Methods: We hypothesized that translating an existing implantable cardiac monitoring device, the Reveal LINQ™ (Medtronic), would present a more immediate solution. Following ethical approval and laparotomy in anesthetized pigs (n = 7), a Reveal LINQ was placed on the serosal surface of the stomach, immediately adjacent to a validated flexible‐printed‐circuit (FPC) electrical mapping array. Data were recorded for periods of 7.5 min, and the resultant signal characteristics from the FPC array and Reveal LINQ were compared.Key Results: The Reveal LINQ device recorded slow waves in 6/7 subjects with a comparable period (p = 0.69), signal‐to‐noise ratio (p = 0.58), and downstroke width (p = 0.98) to the FPC, but with reduced amplitude (p = 0.024). Qualitatively, the Reveal LINQ slow‐wave signal lacked the prolonged repolarization phase present in the FPC signals.Conclusions & Inferences: These findings suggest that existing cardiac monitors may offer an efficient solution for the long‐term monitoring of slow waves. Translation toward implantation now awaits.
- 7 December 2023
- Published by Wiley in Neurogastroenterology & Motility
- Vol. 36 (2) , e14723
Open AccessTranslation of an existing implantable cardiac monitoring device for measurement of gastric electrical slow‐wave activity
Background: Despite evidence that slow‐wave dysrhythmia in the stomach is associated with clinical conditions such as gastroparesis and functional dyspepsia, there is still no widely available device for long‐term monitoring of gastric electrical signals. Actionable biomarkers of gastrointestinal health are critically needed, and an implantable slow‐wave monitoring device could aid in the establishment of causal relationships between symptoms and gastric electrophysiology. Recent developments in the area of wireless implantable gastric monitors demonstrate potential, but additional work and validation are required before this potential can be realized.Methods: We hypothesized that translating an existing implantable cardiac monitoring device, the Reveal LINQ™ (Medtronic), would present a more immediate solution. Following ethical approval and laparotomy in anesthetized pigs (n = 7), a Reveal LINQ was placed on the serosal surface of the stomach, immediately adjacent to a validated flexible‐printed‐circuit (FPC) electrical mapping array. Data were recorded for periods of 7.5 min, and the resultant signal characteristics from the FPC array and Reveal LINQ were compared.Key Results: The Reveal LINQ device recorded slow waves in 6/7 subjects with a comparable period (p = 0.69), signal‐to‐noise ratio (p = 0.58), and downstroke width (p = 0.98) to the FPC, but with reduced amplitude (p = 0.024). Qualitatively, the Reveal LINQ slow‐wave signal lacked the prolonged repolarization phase present in the FPC signals.Conclusions & Inferences: These findings suggest that existing cardiac monitors may offer an efficient solution for the long‐term monitoring of slow waves. Translation toward implantation now awaits.
- 1 September 2023
- Published by American Physiological Society in Journal of Neurophysiology
- Vol. 130 (3) , 719-735
Gradients of response latencies and temporal precision of auditory neurons extend across the whole inferior colliculus
Study of the inferior colliculus (IC) has largely focused on the central nucleus, with little exploration of the outer cortices. Here, we systematically assessed the acoustic response properties from over 2,000 locations in different subregions of the IC. The results revealed spatial trends in temporal response patterns that span all subregions. Furthermore, two populations of temporal response types emerged for neurons in the outer cortices that may contribute to their functional roles in auditory tasks.
- 1 September 2023
- Published by American Physiological Society in Journal of Neurophysiology
- Vol. 130 (3) , 719-735
Gradients of response latencies and temporal precision of auditory neurons extend across the whole inferior colliculus
Study of the inferior colliculus (IC) has largely focused on the central nucleus, with little exploration of the outer cortices. Here, we systematically assessed the acoustic response properties from over 2,000 locations in different subregions of the IC. The results revealed spatial trends in temporal response patterns that span all subregions. Furthermore, two populations of temporal response types emerged for neurons in the outer cortices that may contribute to their functional roles in auditory tasks.
- Open Access
- 16 August 2023
- Published by Elsevier in Neuromodulation: Technology at the Neural Interface
- Vol. 27 (2) , 392-398
Sensing in Sacral Neuromodulation: A Feasibility Study in Subjects With Urinary Incontinence and Retention
- 16 August 2023
- Published by Elsevier in Neuromodulation: Technology at the Neural Interface
- Vol. 27 (2) , 392-398
Open AccessSensing in Sacral Neuromodulation: A Feasibility Study in Subjects With Urinary Incontinence and Retention
- Open Access
- 13 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 29 (15344320) , 2067-2075
Feasibility of Real-Time Conditional Sacral Neuromodulation Using Wireless Bladder Pressure Sensor
Continuous sacral neuromodulation (SNM) is used to treat overactive bladder, reducing urine leakage and increasing capacity. Conditional SNM applies stimulation in response to changing bladder conditions, and is an opportunity to study neuromodulation effects in various disease states. A key advantage of this approach is saving power consumed by stimulation pulses. This study demonstrated feasibility of automatically applying neuromodulation using a wireless bladder pressure sensor, a real-time control algorithm, and the Medtronic Summit ™ RC+S neurostimulation research system. This study tested feasibility of four conditional SNM paradigms over five days in 4 female sheep. Primary outcomes assessed proof of concept of closed-loop system function. While the bladder pressure sensor correlated only weakly to simultaneous catheter-based pressure measurement (correlation 0.26-0.89, median r = 0.52), the sensor and algorithm were accurate enough to automatically trigger SNM appropriately. The neurostimulator executed 98.5% of transmitted stimulation commands with a median latency of 72 ms (n = 1,206), suggesting that rapid decision-making and control is feasible with this platform. On average, bladder capacity increased for continuous SNM and algorithm-controlled paradigms. Some animals responded more strongly to conditional SNM, suggesting that treatment could be individualized. Future research in conditional SNM may elucidate the physiologic underpinnings of differential response and enable clinical translation.
- 13 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 29 (15344320) , 2067-2075
Open AccessFeasibility of Real-Time Conditional Sacral Neuromodulation Using Wireless Bladder Pressure Sensor
Continuous sacral neuromodulation (SNM) is used to treat overactive bladder, reducing urine leakage and increasing capacity. Conditional SNM applies stimulation in response to changing bladder conditions, and is an opportunity to study neuromodulation effects in various disease states. A key advantage of this approach is saving power consumed by stimulation pulses. This study demonstrated feasibility of automatically applying neuromodulation using a wireless bladder pressure sensor, a real-time control algorithm, and the Medtronic Summit ™ RC+S neurostimulation research system. This study tested feasibility of four conditional SNM paradigms over five days in 4 female sheep. Primary outcomes assessed proof of concept of closed-loop system function. While the bladder pressure sensor correlated only weakly to simultaneous catheter-based pressure measurement (correlation 0.26-0.89, median r = 0.52), the sensor and algorithm were accurate enough to automatically trigger SNM appropriately. The neurostimulator executed 98.5% of transmitted stimulation commands with a median latency of 72 ms (n = 1,206), suggesting that rapid decision-making and control is feasible with this platform. On average, bladder capacity increased for continuous SNM and algorithm-controlled paradigms. Some animals responded more strongly to conditional SNM, suggesting that treatment could be individualized. Future research in conditional SNM may elucidate the physiologic underpinnings of differential response and enable clinical translation.