Lisa Jungbauer Nikolas
Research Subjects
Lisa Jungbauer Nikolas has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Sarah J. Offutt
Medtronic Pelvic Health Minneapolis Minnesota USA
3 shared publications - Anne E. Miller
Medtronic Pelvic Health, Minneapolis, MN, USA
1 shared publication Anne G. Sammarco
University Hospitals Cleveland Ohio USA
1 shared publication- Brian J. Linder
Mayo Clinic Department of OB/Gyn Division of Urogynecology Rochester Minnesota USA
1 shared publication - Charles. R. Powell
Department of Urology Indiana University Indianapolis Indiana USA
1 shared publication Colin Goudelocke
Ochsner Medical Center Department of Urology New Orleans Louisiana USA
1 shared publication
Latest Publications
- Open Access
- 25 September 2026
- Published by Wiley in Neurourology and Urodynamics
Sensing in Sacral Neuromodulation: Objective, Individualized Stimulation Response Thresholds Directly From the Lead
Objectives: Sacral neuromodulation (SNM) therapy today relies on visually observed motor responses (e.g., anal bellows contraction, toe flexion) and subjective patient feedback (pelvic region sensations) to optimize lead placement and perform device programming. Measures of sacral nerve activation used in current practice include motor and sensory thresholds, described as the stimulation amplitudes associated with first observed or reported stimulation responses. This study evaluated the utility of sacral evoked responses (SERs), recorded directly from implanted commercial SNM leads, as objective indicators of sacral nerve activation. Materials and Methods: The PEER 2 Cohort 1 study was a multi‐center, prospective, clinical feasibility study in female overactive bladder patients undergoing a tined lead evaluation for SNM using InterStim™ SureScan™ MRI leads. An investigational external neurostimulator was used to collect electrophysiological signal recordings directly from the implanted lead (SER recordings), in addition to motor and sensory thresholds at three timepoints: intraoperatively (OR), immediately postoperatively (PO), and at the end of therapy evaluation (Trial End). SER recordings were processed to determine stimulation amplitudes associated with first detectable signal (SER threshold, SERT) and analyzed for comparison with the motor and sensory thresholds. Results: Lead‐recorded SERs were reliably detected across subjects and timepoints: OR: 100% (89/89 subjects); PO 98.9% (87/88 subjects); Trial End: 97.7% (86/88 subjects). SERTs demonstrated statistically significant correlation with both motor and sensory thresholds across six bipolar electrode configurations ( R = 0.46–0.92; p < 0.001). Compared to sensory thresholds, SERTs were a more sensitive measure of sacral nerve activation, detected at or below sensory thresholds in 57%–84% of subjects. SERTs also exhibited less variability across repeated measurements compared to sensory thresholds ( p < 0.001). Replicate SERTs showed no change in 55.9% of subjects, whereas sensory thresholds showed no change in only 20.6% of subjects. Conclusions: The study results demonstrate that SERs recorded from SNM leads are reliably detected , clinically relevant , sensitive , and consistent markers of sacral nerve activation, offering an objective alternative to present‐day subjective measures . Integrating lead‐sensed SERs may streamline SNM programming and lead placement, introducing a simplified and standardized measure for optimizing and delivering patient‐specific SNM therapy. Clinical Trial Registration: ClinicalTrials.gov NCT05200923. Investigational device. Limited by Federal (U.S.) law to investigational use. The research system and sensing feature are not approved by the FDA or any other regulatory authority and are not for sale in the US or internationally.
- 25 September 2026
- Published by Wiley in Neurourology and Urodynamics
Open AccessSensing in Sacral Neuromodulation: Objective, Individualized Stimulation Response Thresholds Directly From the Lead
Objectives: Sacral neuromodulation (SNM) therapy today relies on visually observed motor responses (e.g., anal bellows contraction, toe flexion) and subjective patient feedback (pelvic region sensations) to optimize lead placement and perform device programming. Measures of sacral nerve activation used in current practice include motor and sensory thresholds, described as the stimulation amplitudes associated with first observed or reported stimulation responses. This study evaluated the utility of sacral evoked responses (SERs), recorded directly from implanted commercial SNM leads, as objective indicators of sacral nerve activation. Materials and Methods: The PEER 2 Cohort 1 study was a multi‐center, prospective, clinical feasibility study in female overactive bladder patients undergoing a tined lead evaluation for SNM using InterStim™ SureScan™ MRI leads. An investigational external neurostimulator was used to collect electrophysiological signal recordings directly from the implanted lead (SER recordings), in addition to motor and sensory thresholds at three timepoints: intraoperatively (OR), immediately postoperatively (PO), and at the end of therapy evaluation (Trial End). SER recordings were processed to determine stimulation amplitudes associated with first detectable signal (SER threshold, SERT) and analyzed for comparison with the motor and sensory thresholds. Results: Lead‐recorded SERs were reliably detected across subjects and timepoints: OR: 100% (89/89 subjects); PO 98.9% (87/88 subjects); Trial End: 97.7% (86/88 subjects). SERTs demonstrated statistically significant correlation with both motor and sensory thresholds across six bipolar electrode configurations ( R = 0.46–0.92; p < 0.001). Compared to sensory thresholds, SERTs were a more sensitive measure of sacral nerve activation, detected at or below sensory thresholds in 57%–84% of subjects. SERTs also exhibited less variability across repeated measurements compared to sensory thresholds ( p < 0.001). Replicate SERTs showed no change in 55.9% of subjects, whereas sensory thresholds showed no change in only 20.6% of subjects. Conclusions: The study results demonstrate that SERs recorded from SNM leads are reliably detected , clinically relevant , sensitive , and consistent markers of sacral nerve activation, offering an objective alternative to present‐day subjective measures . Integrating lead‐sensed SERs may streamline SNM programming and lead placement, introducing a simplified and standardized measure for optimizing and delivering patient‐specific SNM therapy. Clinical Trial Registration: ClinicalTrials.gov NCT05200923. Investigational device. Limited by Federal (U.S.) law to investigational use. The research system and sensing feature are not approved by the FDA or any other regulatory authority and are not for sale in the US or internationally.
- Open Access
- 7 December 2023
- Published by Wiley in Neurogastroenterology & Motility
- Vol. 36 (2) , e14723
Translation of an existing implantable cardiac monitoring device for measurement of gastric electrical slow‐wave activity
Background: Despite evidence that slow‐wave dysrhythmia in the stomach is associated with clinical conditions such as gastroparesis and functional dyspepsia, there is still no widely available device for long‐term monitoring of gastric electrical signals. Actionable biomarkers of gastrointestinal health are critically needed, and an implantable slow‐wave monitoring device could aid in the establishment of causal relationships between symptoms and gastric electrophysiology. Recent developments in the area of wireless implantable gastric monitors demonstrate potential, but additional work and validation are required before this potential can be realized.Methods: We hypothesized that translating an existing implantable cardiac monitoring device, the Reveal LINQ™ (Medtronic), would present a more immediate solution. Following ethical approval and laparotomy in anesthetized pigs (n = 7), a Reveal LINQ was placed on the serosal surface of the stomach, immediately adjacent to a validated flexible‐printed‐circuit (FPC) electrical mapping array. Data were recorded for periods of 7.5 min, and the resultant signal characteristics from the FPC array and Reveal LINQ were compared.Key Results: The Reveal LINQ device recorded slow waves in 6/7 subjects with a comparable period (p = 0.69), signal‐to‐noise ratio (p = 0.58), and downstroke width (p = 0.98) to the FPC, but with reduced amplitude (p = 0.024). Qualitatively, the Reveal LINQ slow‐wave signal lacked the prolonged repolarization phase present in the FPC signals.Conclusions & Inferences: These findings suggest that existing cardiac monitors may offer an efficient solution for the long‐term monitoring of slow waves. Translation toward implantation now awaits.
- 7 December 2023
- Published by Wiley in Neurogastroenterology & Motility
- Vol. 36 (2) , e14723
Open AccessTranslation of an existing implantable cardiac monitoring device for measurement of gastric electrical slow‐wave activity
Background: Despite evidence that slow‐wave dysrhythmia in the stomach is associated with clinical conditions such as gastroparesis and functional dyspepsia, there is still no widely available device for long‐term monitoring of gastric electrical signals. Actionable biomarkers of gastrointestinal health are critically needed, and an implantable slow‐wave monitoring device could aid in the establishment of causal relationships between symptoms and gastric electrophysiology. Recent developments in the area of wireless implantable gastric monitors demonstrate potential, but additional work and validation are required before this potential can be realized.Methods: We hypothesized that translating an existing implantable cardiac monitoring device, the Reveal LINQ™ (Medtronic), would present a more immediate solution. Following ethical approval and laparotomy in anesthetized pigs (n = 7), a Reveal LINQ was placed on the serosal surface of the stomach, immediately adjacent to a validated flexible‐printed‐circuit (FPC) electrical mapping array. Data were recorded for periods of 7.5 min, and the resultant signal characteristics from the FPC array and Reveal LINQ were compared.Key Results: The Reveal LINQ device recorded slow waves in 6/7 subjects with a comparable period (p = 0.69), signal‐to‐noise ratio (p = 0.58), and downstroke width (p = 0.98) to the FPC, but with reduced amplitude (p = 0.024). Qualitatively, the Reveal LINQ slow‐wave signal lacked the prolonged repolarization phase present in the FPC signals.Conclusions & Inferences: These findings suggest that existing cardiac monitors may offer an efficient solution for the long‐term monitoring of slow waves. Translation toward implantation now awaits.
- Open Access
- 16 August 2023
- Published by Elsevier in Neuromodulation: Technology at the Neural Interface
- Vol. 27 (2) , 392-398
Sensing in Sacral Neuromodulation: A Feasibility Study in Subjects With Urinary Incontinence and Retention
- 16 August 2023
- Published by Elsevier in Neuromodulation: Technology at the Neural Interface
- Vol. 27 (2) , 392-398
Open AccessSensing in Sacral Neuromodulation: A Feasibility Study in Subjects With Urinary Incontinence and Retention