Nina Burlac
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nina Burlac has a total of 262 co-authors. Here are the top co-authors by number of shared publications:
- Giuseppe Salamanna
Università degli Studi di Roma Tre 00146 Rome Italy
3 shared publications - Diego Tagnani
INFN, Sezione di Roma Tre, Via della Vasca Navale 84, I-00146 Rome
2 shared publications - Francesco Paissan
Istituto Nazionale di Fisica Nucleare Sezione di Roma Tre 00146 Rome Italy
2 shared publications A C Sousa
South Dakota Mines, Rapid City, South Dakota 57701, USA
1 shared publicationA Di Giacinto
Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Gran Sasso, 67100 Assergi (AQ), Italy
1 shared publication- A I Colon-Rivera
Triangle Universities Nuclear Laboratory 27708 Durham NC USA
1 shared publication
Latest Publications
- Top Cited PapersOpen Access
- 16 January 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (2) , 022701
First Results on the Search for Lepton Number Violating Neutrinoless Double- β Decay with the LEGEND-200 Experiment
The LEGEND Collaboration is searching for neutrinoless double-beta ( 0 ν β β ) decay by operating high-purity germanium detectors enriched in Ge 76 in a low-background liquid argon environment. Building on key technological innovations from the GERmanium Detector Array (GERDA) experiment and the MAJORANA DEMONSTRATOR experiment, LEGEND-200 has performed a first 0 ν β β decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of 0.5 − 0.2 + 0.3 cts / ( keV ton yr ) in the 0 ν β β decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of 2.8 × 10 26 yr on the half-life of 0 ν β β decay, reveals no evidence for a signal and sets a new observed lower limit at T 1 / 2 0 ν > 1.9 × 10 26 yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range m β β < 75 – 200 meV , depending on the adopted nuclear matrix element.
- 16 January 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (2) , 022701
Top Cited PapersOpen AccessFirst Results on the Search for Lepton Number Violating Neutrinoless Double- β Decay with the LEGEND-200 Experiment
The LEGEND Collaboration is searching for neutrinoless double-beta ( 0 ν β β ) decay by operating high-purity germanium detectors enriched in Ge 76 in a low-background liquid argon environment. Building on key technological innovations from the GERmanium Detector Array (GERDA) experiment and the MAJORANA DEMONSTRATOR experiment, LEGEND-200 has performed a first 0 ν β β decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of 0.5 − 0.2 + 0.3 cts / ( keV ton yr ) in the 0 ν β β decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of 2.8 × 10 26 yr on the half-life of 0 ν β β decay, reveals no evidence for a signal and sets a new observed lower limit at T 1 / 2 0 ν > 1.9 × 10 26 yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range m β β < 75 – 200 meV , depending on the adopted nuclear matrix element.
- Open Access
- 1 July 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1080
Early results of the LEGEND-200 experiment
- 1 July 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1080
Open AccessEarly results of the LEGEND-200 experiment
- Open Access
- 1 September 2023
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 18 (09) , P09007
The Front-End electronics for the liquid Argon instrumentation of the LEGEND-200 experiment
In this paper we provide a detailed technical description of the Front-End (FE) electronics for the liquid Argon instrumentation of the LEGEND-200 experiment, searching for the very rare, hypothetical neutrinoless double β decay process at the Italian Laboratori Nazionali del Gran Sasso. The design stems from the need to read out the silicon photo-multiplier response to the scintillation light in the liquid Argon with excellent single-photon resolution. The FE electronics is required to be placed far from the detectors to meet the experiment's radio-purity constraints. This constraint represents a challenge for a high signal-to-noise ratio. We address how this could be achieved in a stable way. The system was installed in July 2021 and has been commissioned with the rest of LEGEND-200, proving we could attain a very low overall level of electrical noise of 250 μV peak-to-peak.
- 1 September 2023
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 18 (09) , P09007
Open AccessThe Front-End electronics for the liquid Argon instrumentation of the LEGEND-200 experiment
In this paper we provide a detailed technical description of the Front-End (FE) electronics for the liquid Argon instrumentation of the LEGEND-200 experiment, searching for the very rare, hypothetical neutrinoless double β decay process at the Italian Laboratori Nazionali del Gran Sasso. The design stems from the need to read out the silicon photo-multiplier response to the scintillation light in the liquid Argon with excellent single-photon resolution. The FE electronics is required to be placed far from the detectors to meet the experiment's radio-purity constraints. This constraint represents a challenge for a high signal-to-noise ratio. We address how this could be achieved in a stable way. The system was installed in July 2021 and has been commissioned with the rest of LEGEND-200, proving we could attain a very low overall level of electrical noise of 250 μV peak-to-peak.
- Open Access
Present and Future of 0ν2β Searches with Germanium
Among the several experiments and techniques conceived of to search for neutrinoless double decay () in a handful of isotopes, presently the best lower limit on the half-life for this rare process, is provided by those using Ge, a rare isotope of germanium. Such a lower limit is of 1.8 × 10 y. Building from such a successful achievement of the GERDA and Majorana Demonstrator experiments, the baton with Ge passes now to the LEGEND experiment. Using a two-stage approach with about 200 kg and then 1 t of germanium, LEGEND aims to attain a sensitivity of around 10 y, which will enable it to probe the standard inverted-ordering neutrino mass scenario. We touch upon the past generation of experiments to illustrate their strong and weak points, review the general concept and design of LEGEND, and describe the LEGEND-200 detector and its preliminary performance. We also illustrate how the backgrounds can have a dramatic effect on the search and in which way the latter can be mitigated.Open AccessPresent and Future of 0ν2β Searches with Germanium
Among the several experiments and techniques conceived of to search for neutrinoless double decay () in a handful of isotopes, presently the best lower limit on the half-life for this rare process, is provided by those using Ge, a rare isotope of germanium. Such a lower limit is of 1.8 × 10 y. Building from such a successful achievement of the GERDA and Majorana Demonstrator experiments, the baton with Ge passes now to the LEGEND experiment. Using a two-stage approach with about 200 kg and then 1 t of germanium, LEGEND aims to attain a sensitivity of around 10 y, which will enable it to probe the standard inverted-ordering neutrino mass scenario. We touch upon the past generation of experiments to illustrate their strong and weak points, review the general concept and design of LEGEND, and describe the LEGEND-200 detector and its preliminary performance. We also illustrate how the backgrounds can have a dramatic effect on the search and in which way the latter can be mitigated.