Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Koshiro Shimasaki has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Osteoporotic Bone Quality Significantly Increases Proximal Stress Concentration: A Comparative Thermoelastic Stress Analysis with Normal Composite Femurs

    by Ryunosuke Watanabe, Shota Yasunaga, Fumi Hirose, Koshiro Shimasaki, Tomohiro Yoshizawa, Yasuhiro Homma, Tomofumi Nishino, Hajime Mishima, Yoshihisa Harada

    Proximal femoral fractures associated with osteoporosis are an important clinical problem, yet how bone quality independently influences stress distribution remains insufficiently understood. This study aimed to quantitatively compare surface stress distribution between normal and osteoporotic proximal femoral models using thermoelastic stress analysis (TSA). Fourth-generation composite femurs with identical external geometries were subjected to cyclic compressive loading at a 9° adduction angle, with different maximum loads applied to avoid structural failure (normal: 1900 N; osteoporotic: 1000 N). TSA was performed using an infrared lock-in system to obtain surface stress maps, and stress values were evaluated across key proximal regions and along the medial and lateral cortices. The osteoporotic group showed higher maximum stress values in the medial neck (−37.79 vs. −11.52 MPa), lateral neck (24.70 vs. 8.75 MPa), and intertrochanteric crest (−17.98 vs. −6.05 MPa), corresponding to approximately 1.8–3.5-fold increases compared with the normal model values normalized to 1000 N. Mean stress values were also higher by approximately 1.9–2.4-fold across regions. These results suggest that reduced bone quality is associated with increased proximal stress concentration. They may also help guide implant and fixation strategies, including stem selection and fixation configuration, by identifying regions susceptible to stress concentration under different bone quality conditions.

  • Open Access

    Influence of bone quality on femoral stress distribution after cemented stem insertion: an experimental thermoelastic stress analysis

    by Shota Yasunaga, Ryunosuke Watanabe, Tomofumi Nishino, Tomohiro Yoshizawa, Fumi Hirose, Koshiro Shimasaki, Hajime Mishima, Yoshihisa Harada

    Purpose: With an ageing population, the number of total hip arthroplasty (THA) performed in osteoporotic patients is increasing. Cemented stems are often chosen for osteoporotic bone owing to their lower fracture risk. However, how bone quality influences stress distribution after cemented stem insertion remains unclear. This study compared femoral stress distribution between normal and osteoporotic femora using thermoelastic stress analysis (TSA). Materials and methods: 6 composite femora were used: 3 normal adult male models (#3403) and 3 osteoporotic models (#3503). C-stem AMT cemented stems were implanted with a standardised technique. TSA was conducted before and after stem insertion under physiological loading (normal: 100–1900 N; osteoporotic: 100–1000 N). Stress distribution was analysed by Gruen zones and compared using linear mixed models. Results: In the normal models, stress uniformly decreased after stem insertion with a distal shift of peak stress. In the osteoporotic models, proximal stress decreased markedly, while distal stress (zones 4L, 4M) increased, demonstrating a more pronounced distal shift. Conclusions: Bone quality strongly affects load transfer after cemented stem insertion. Osteoporotic bone demonstrated proximal stress loss and distal concentration, possibly underlying atypical periprosthetic femoral fractures. TSA provides useful insights for implant design and surgical planning in osteoporotic THA.

  • Open Access

    Radiographic Evolution of Contralateral Asymptomatic Incomplete Atypical Femoral Fractures in Autoimmune Disease Patients

    by Tomofumi Nishino, Kojiro Hyodo, Yukei Matsumoto, Yohei Yanagisawa, Koshiro Shimasaki, Ryunosuke Watanabe, Tomohiro Yoshizawa, Hajime Mishima

    Background/Objectives: Atypical femoral fracture (AFF) represents a diagnostic and therapeutic challenge, particularly in autoimmune disease patients receiving long-term bisphosphonate (BP) and glucocorticoid (GC) therapy. Although bilateral AFF is common, the radiographic evolution of asymptomatic incomplete lesions identified at the time of a complete fracture remains insufficiently defined. This study aimed to characterize the natural history and imaging biomarkers associated with progression in this biologically homogeneous high-risk population. Methods: Ten female autoimmune disease patients with complete AFF and asymptomatic incomplete contralateral lesions were retrospectively evaluated over a mean 59 months. Serial radiographs were assessed for cortical beaking, periosteal flaring, and transverse radiolucent lines. All patients discontinued BP therapy postoperatively; teriparatide was administered when tolerated. Results: Six lesions regressed, three remained stable, and one progressed—this progressing case being the only limb with a transverse radiolucent line at baseline. No patient developed symptoms or sustained a complete fracture on the contralateral side. Radiographic remodeling occurred independently of symptoms. BP discontinuation and, when tolerated, teriparatide appeared to contribute to lesion stabilization, although statistical significance was not achieved. Conclusions: In autoimmune patients with severe long-term BP and GC exposure, most asymptomatic incomplete AFF identified at the time of contralateral complete fracture remains stable or improves under conservative management. A transverse radiolucent line is the most decisive imaging biomarker predictive of progression and warrants intensified surveillance or consideration of prophylactic fixation. Larger cohorts are needed to refine risk stratification algorithms and optimize diagnostic and management strategies.

  • Optimising stem selection for conversion total hip arthroplasty following femoral trochanteric fracture surgery: an exploratory study using thermoelastic stress analysis

    by Koshiro Shimasaki, Ryunosuke Watanabe, Tomofumi Nishino, Tomohiro Yoshizawa, Fumi Hirose, Shota Yasunaga, Hajime Mishima, Yoshihisa Harada

    Purpose: To evaluate the effect of the stem length on femoral stress distribution, using thermoelastic stress analysis (TSA) to provide insights into optimal stem selection for conversion to total hip arthroplasty (cTHA) following femoral trochanteric fracture. Methods: 6 simulated femurs were prepared via intramedullary nailing followed by implant removal to construct a post-explantation model. A screw hole was replicated 135 mm distal to the apex of the greater trochanter. Following femoral neck osteotomy, cTHA models were constructed using either a quadrangular taper collared standard or long stem. TSA was conducted under vertical loading, measuring the maximum change in the sum of principal stresses around the screw hole. The stress-reducing effects of both stems were compared using the Wilcoxon signed-rank test. Results: Maximum stress around the screw hole decreased after stem insertion, with a greater reduction in the long stem group. The median maximum stress at the distal screw hole measured 11.2 and 8.42 MPa laterally and −14.6 and −12.3 MPa medially for the standard and long stem, respectively. The long stem significantly reduced stress in both regions. Conclusions: Stem insertion alleviated stress concentration, with long stem offering greater relief. The long stem effectively redistributed stress, providing valuable insights for optimising stem selection and reducing postoperative fracture risk.


  • Open Access

    Factors Affecting Hospital Stay Duration in the Conservative Treatment of Patients With Osteoporotic Vertebral Fractures

    by Koshiro Shimasaki, Kousei Miura, Tomohiro Yoshizawa, Tomofumi Nishino, Harumitsu Ichimura, Masafumi Uesugi, Hajime Mishima

    Introduction: Our research question explores the factors contributing to the substantial variation in the length of hospital stay among patients receiving inpatient conservative treatment for osteoporotic vertebral fractures (OVFs). This study aimed to identify key determinants influencing hospitalization duration in this patient population. Methods: Overall, 187 patients admitted for conservative treatment of OVF at a single institution between April 2020 and March 2024 were retrospectively analyzed. Data on age, sex, Charlson Comorbidity Index (CCI), cognitive impairment, pre-injury mobility, cohabitation status, in-hospital complications, nutritional status, sarcopenia, discharge destination, and length of stay were obtained. A subgroup analysis was conducted to compare patients discharged home with those discharged to non-home settings. Results: Multiple regression analysis revealed that cognitive impairment, pre-injury mobility, cohabitation status, and in-hospital complications significantly influenced the length of stay. In the subgroup analysis, sex and cognitive impairment were significant in the univariate analysis, whereas cognitive function remained significant in the multivariate analysis. Conclusions: Inpatients with OVFs undergoing conservative treatment had a significantly longer length of stay if they had cognitive impairment, lower pre-injury mobility, lived alone, or experienced hospitalization-related complications. Patients with cognitive impairment were less likely to be discharged home but more likely to be discharged to non-home settings, including care facilities. Early intervention by a multidisciplinary team targeting these factors can increase home-discharge rates, reduce length of stay, lower medical costs, and extend healthy life expectancy.

  • Open Access

    Biomechanical comparison of cemented versus cementless fixation in intraoperative femoral fractures during total hip arthroplasty

    by Ryunosuke Watanabe, Tomofumi Nishino, Tomohiro Yoshizawa, Fumi Hirose, Shota Yasunaga, Koshiro Shimasaki, Hajime Mishima

    Introduction: Intraoperative periprosthetic femoral fractures (IPFF) are serious complications of total hip arthroplasty (THA) that occur more frequently with cementless stems than with cemented stems. Although cerclage wiring is commonly used to stabilize IPFFs, the biomechanical effects of subsequent stem fixation methods remain unclear. This study aimed to compare the biomechanical stability of cemented and cementless stems following cerclage wire fixation in an experimental IPFF model. Materials and methods: Six fourth-generation composite femurs with simulated Vancouver A2-type fractures were stabilized using a single 1.8 mm cerclage wire. Identical stem designs of polished cemented stems and fully hydroxyapatite-coated cementless stems were implanted in three specimens of each group. After applying a vertical axial load of 2000 N, an additional 40° of internal rotation was imposed. The primary outcome was the maximum torque at the time of fracture. Secondary outcomes included the maximum internal rotation angle, construct stiffness (calculated from force-displacement curves above 1500 N), and peak strain at three positions on the cerclage wire, measured using strain gauges. Results: The maximum torque was significantly higher in the cemented group compared to the cementless group (160.8 ± 24.9 vs. 89.1 ± 18.0 N·m, p = 0.016). Although the differences in stiffness and internal rotation angle were not statistically significant, both trended higher in the cemented group. The peak strain was consistently lower in the cemented group, with a significant difference at the medial side of the fracture line ( p = 0.011, Cohen’s d = − 3.64). Conclusions: Cemented stems demonstrated superior biomechanical stability following cerclage wire fixation in the IPFF model, likely because of improved stress distribution via the cement mantle. Therefore, cemented fixation may be a favorable option for managing IPFF during THA.


  • Open Access

    Optimizing Stem Length in Conversion Total Hip Arthroplasty: An Expanded Finite Element Analysis

    by Koshiro Shimasaki, Tomofumi Nishino, Tomohiro Yoshizawa, Ryunosuke Watanabe, Fumi Hirose, Shota Yasunaga, Hajime Mishima

    Background/Objectives: Stress concentration around distal screw-removal holes confers a major risk for periprosthetic fractures following conversion total hip arthroplasty (cTHA) for intertrochanteric femoral fractures. Optimal stem-selection criteria and guidelines for cTHA can improve clinical outcomes. We determined the influence of the cementless stem length on the stress distribution around distal screw-removal holes. Methods: For the finite element analysis, institutional data from preoperative CT scans of contralateral femurs of patients who underwent THA were used. To replicate the post-nail-removal state, we used 3D registration of standard triangulated language data of the intramedullary nail as an unused material to simulate distal screw-removal holes, located 135 mm from the proximal end of the intramedullary nail. Cementless stems of 130, 140, 150, and 160 mm were individually registered using STL data, and cTHA models were constructed accordingly. Using simulations under load conditions representing normal walking and stair climbing, the mean and maximum equivalent stress values around the distal screw-removal holes were calculated. For multiple comparisons, repeated-measures ANOVA with Bonferroni correction was employed. Results: Compared to the 130 mm stem, the 150 mm and 160 mm stems similarly reduced the maximum equivalent stress around the distal screw-removal holes, although the 140 mm stem showed no significant difference with other stems. Conclusions: A ≥150 mm stem length reliably mitigated stress concentration around distal screw-removal holes post-cTHA; it is the optimal choice for balancing effectiveness and risk of complications and may contribute to improved long-term clinical outcomes. This study provides practical evidence for stem selection in cTHA and offers valuable insights for future treatment guidelines.


  • Open Access

    Optimizing Stem Length in Conversion Hip Arthroplasty: An Expanded Finite Element Analysis

    by Koshiro Shimasaki, Tomofumi Nishino, Tomohiro Yoshizawa, Ryunosuke Watanabe, Fumi Hirose, Shota Yasunaga, Hajime Mishima

    Background/Objectives: Stress concentration around distal screw-removal holes confers a major risk for periprosthetic fractures following conversion total hip arthroplasty (cTHA) for intertrochanteric femoral fractures. Optimal stem-selection criteria and guidelines for cTHA can improve clinical outcomes. We determined the influence of cementless stem length on stress distribution around distal screw-removal holes. Methods: For finite element analysis, institutional data from preoperative CT scans of contralateral femurs of patients who underwent THA were used. To replicate the post-nail-removal state, we used 3D registration of Standard Triangulated Language data of the intramedullary nail as an unused material to simulate distal screw-removal holes, located 135 mm from the proximal end of the intramedullary nail. Cementless stems of 130, 140, 150, and 160 mm were individually registered using STL data, and cTHA models were constructed accordingly. Using simulations under load conditions representing normal walking and stair climbing, the mean and maximum equivalent stress values around the distal screw-removal holes were calculated. Repeated-measures ANOVA with Bonferroni correction was used for multiple comparisons. Results: Compared to the 130-mm stem, the 150-mm and 160-mm stems similarly reduced the maximum equivalent stress around distal screw-removal holes, although the 140-mm stem showed no significant difference with other stems. Conclusions: A ≥150-mm stem length reliably mitigates stress concentration around distal screw-removal holes post-cTHA, is the optimal choice for balancing effectiveness and risk of complications, and may contribute to improved long-term clinical outcomes. This study provides practical evidence for stem selection in cTHA and offers valuable insights for future treatment guidelines.


  • Open Access

    Assessment of Hip Abduction Motion Assistance Using a Single-Joint Hybrid Assistive Limb Robot: Feasibility and Safety Evaluation in Healthy Adults

    by Fumi Hirose, Tomofumi Nishino, Yukiyo Shimizu, Yuichiro Soma, Ayumu Haginoya, Shota Yasunaga, Koshiro Shimasaki, Ryunosuke Watanabe, Tomohiro Yoshizawa, Hajime Mishima

    Background/Objectives: Preoperative muscle atrophy leads to persistent gait abnormalities in patients undergoing total hip arthroplasty (THA). Efficient motor learning of the gluteus medius is crucial for their recovery. In this study, a single-joint hybrid assistive limb (HAL) was developed to assist hip abduction. We aimed to evaluate the muscle activity and safety of this device during hip abduction in healthy adults. Methods: Ten healthy adults (five males and five females; mean age, 40.7 years) with no hip disorders performed one set of 30 repetitions of side-lying hip abduction under three conditions: without HAL (pre-HAL), with HAL, and without HAL (post-HAL). Muscle activities of the gluteus medius, gluteus maximus, tensor fasciae latae, rectus femoris, and biceps femoris (expressed as percentage of maximum voluntary contraction [%MVC]); vital signs; hip visual analog scale (VAS); and hip abduction and flexion angles were assessed. The mean values were compared among the conditions. Results: The %MVC of the gluteus medius significantly increased from 52% (pre-HAL) to 75.4% (HAL) and then decreased slightly to 61.6% (post-HAL). No other muscle groups showed significant changes. Vital signs and hip VAS scores showed no significant variation. Although no significant differences were found in the hip abduction and flexion angles, a reduction in the hip flexion angle was observed in the HAL and post-HAL conditions. Conclusions: The hip abduction HAL effectively and safely enhanced gluteus medius activity. Reduction in the hip flexion angle during HAL and post-HAL suggests the possibility of appropriate abduction movements and motor learning effects.


  • Open Access

    Stress Analysis in Conversion Total Hip Arthroplasty: A Finite Element Analysis on Stem Length and Distal Screw Hole

    by Koshiro Shimasaki, Tomofumi Nishino, Tomohiro Yoshizawa, Ryunosuke Watanabe, Fumi Hirose, Shota Yasunaga, Hajime Mishima

    Background/Objectives: Proximal femoral fractures are particularly common in older adults, and cases requiring conversion to total hip arthroplasty may arise because of treatment failure or osteoarthritis. Fractures around the distal screw removal holes can be problematic. This study aimed to analyze the relationship between stem length and femoral stress distribution to determine the optimal stem length. Methods: A finite element analysis simulation was conducted using pre-existing femoral computed tomography data, an intramedullary nail, and three types of stems of varying lengths. Loads simulating normal walking and stair climbing were applied, and the average and maximum equivalent stresses were measured on both the medial and lateral sides of the distal screw removal hole for each stem length. Statistical analysis was then performed to evaluate the stress distributions. Results: The average stress around the distal screw removal hole tended to decrease as stem length increased. The maximum stress was significantly lower with the 160-mm stem, which provides a 40-mm bridging length, compared to the 120-mm and 130-mm stems, where the stem tip aligned with or only slightly extended past the distal screw removal hole (bridging lengths of 0 mm and 10 mm, respectively). Conclusions: In conversion hip total arthroplasty following proximal femoral fractures, using a sufficiently long stem can help avoid stress concentration around the distal screw removal hole, thereby potentially reducing the risk of periprosthetic fractures.