RWRyunosuke Watanabe

Ryunosuke Watanabe

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ryunosuke Watanabe has a total of 50 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Preclinical evaluation of a fully threaded biodegradable magnesium alloy headless compression screw for enhanced fixation in small bones

    by Hiroshi Noguchi, Kotaro Hanada, Ryunosuke Watanabe, Yasukazu Totoki, Yohei Tomaru, Akira Ikumi, Akira Kitagawa, Sakiko Orui, Lulu Zhang, Hajime Mishima

  • Open Access

    Osteoporotic Bone Quality Significantly Increases Proximal Stress Concentration: A Comparative Thermoelastic Stress Analysis with Normal Composite Femurs

    by Ryunosuke Watanabe, Shota Yasunaga, Fumi Hirose, Koshiro Shimasaki, Tomohiro Yoshizawa, Yasuhiro Homma, Tomofumi Nishino, Hajime Mishima, Yoshihisa Harada

    Proximal femoral fractures associated with osteoporosis are an important clinical problem, yet how bone quality independently influences stress distribution remains insufficiently understood. This study aimed to quantitatively compare surface stress distribution between normal and osteoporotic proximal femoral models using thermoelastic stress analysis (TSA). Fourth-generation composite femurs with identical external geometries were subjected to cyclic compressive loading at a 9° adduction angle, with different maximum loads applied to avoid structural failure (normal: 1900 N; osteoporotic: 1000 N). TSA was performed using an infrared lock-in system to obtain surface stress maps, and stress values were evaluated across key proximal regions and along the medial and lateral cortices. The osteoporotic group showed higher maximum stress values in the medial neck (−37.79 vs. −11.52 MPa), lateral neck (24.70 vs. 8.75 MPa), and intertrochanteric crest (−17.98 vs. −6.05 MPa), corresponding to approximately 1.8–3.5-fold increases compared with the normal model values normalized to 1000 N. Mean stress values were also higher by approximately 1.9–2.4-fold across regions. These results suggest that reduced bone quality is associated with increased proximal stress concentration. They may also help guide implant and fixation strategies, including stem selection and fixation configuration, by identifying regions susceptible to stress concentration under different bone quality conditions.

  • Open Access

    Biodegradable, fully threaded magnesium alloy headless compression screw for small-bone fixation: Mechanical and biological safety assessments and in vivo study

    by Hiroshi Noguchi, Kotaro Hanada, Ryunosuke Watanabe, Yasutoki Totoki, Yohei Tomaru, Akira Ikumi, Akira Kitagawa, Sakiko Orui, Lulu Zhang, Hajime Mishima

    Headless compression (HC) screws used in the treatment of bone fractures have clinical issues related to screw material and design, including loosening and adverse effects from long-term implantation. Consequently, there is a strong need for biodegradable HC screws in clinical sites. In this study, we conducted safety assessments and in vivo tests on a newly developed, fully threaded, biodegradable magnesium (Mg) alloy HC screw to evaluate its feasibility for clinical use. Mechanical and biological safety assessment results indicated that the developed Mg alloy screw demonstrated insertability and bone fixation performance, as well as excellent biocompatibility, comparable to or superior to that of conventional approved HC screws. In vivo studies using a rabbit model over short- and long-term periods revealed that the developed Mg alloy screw was almost completely degraded and resorbed by 10 months post-implantation. During the degradation process, gas cavities formed around the implanted screw and subsequently decreased, accompanied by bone formation and remodeling. Furthermore, the effect of screw degradation products on target organs was found to be minimal. These findings indicated that the developed full-thread Mg alloy HC screw identifies no safety concerns for clinical use.

  • Open Access

    Influence of bone quality on femoral stress distribution after cemented stem insertion: an experimental thermoelastic stress analysis

    by Shota Yasunaga, Ryunosuke Watanabe, Tomofumi Nishino, Tomohiro Yoshizawa, Fumi Hirose, Koshiro Shimasaki, Hajime Mishima, Yoshihisa Harada

    Purpose: With an ageing population, the number of total hip arthroplasty (THA) performed in osteoporotic patients is increasing. Cemented stems are often chosen for osteoporotic bone owing to their lower fracture risk. However, how bone quality influences stress distribution after cemented stem insertion remains unclear. This study compared femoral stress distribution between normal and osteoporotic femora using thermoelastic stress analysis (TSA). Materials and methods: 6 composite femora were used: 3 normal adult male models (#3403) and 3 osteoporotic models (#3503). C-stem AMT cemented stems were implanted with a standardised technique. TSA was conducted before and after stem insertion under physiological loading (normal: 100–1900 N; osteoporotic: 100–1000 N). Stress distribution was analysed by Gruen zones and compared using linear mixed models. Results: In the normal models, stress uniformly decreased after stem insertion with a distal shift of peak stress. In the osteoporotic models, proximal stress decreased markedly, while distal stress (zones 4L, 4M) increased, demonstrating a more pronounced distal shift. Conclusions: Bone quality strongly affects load transfer after cemented stem insertion. Osteoporotic bone demonstrated proximal stress loss and distal concentration, possibly underlying atypical periprosthetic femoral fractures. TSA provides useful insights for implant design and surgical planning in osteoporotic THA.

  • Open Access

    Radiographic Evolution of Contralateral Asymptomatic Incomplete Atypical Femoral Fractures in Autoimmune Disease Patients

    by Tomofumi Nishino, Kojiro Hyodo, Yukei Matsumoto, Yohei Yanagisawa, Koshiro Shimasaki, Ryunosuke Watanabe, Tomohiro Yoshizawa, Hajime Mishima

    Background/Objectives: Atypical femoral fracture (AFF) represents a diagnostic and therapeutic challenge, particularly in autoimmune disease patients receiving long-term bisphosphonate (BP) and glucocorticoid (GC) therapy. Although bilateral AFF is common, the radiographic evolution of asymptomatic incomplete lesions identified at the time of a complete fracture remains insufficiently defined. This study aimed to characterize the natural history and imaging biomarkers associated with progression in this biologically homogeneous high-risk population. Methods: Ten female autoimmune disease patients with complete AFF and asymptomatic incomplete contralateral lesions were retrospectively evaluated over a mean 59 months. Serial radiographs were assessed for cortical beaking, periosteal flaring, and transverse radiolucent lines. All patients discontinued BP therapy postoperatively; teriparatide was administered when tolerated. Results: Six lesions regressed, three remained stable, and one progressed—this progressing case being the only limb with a transverse radiolucent line at baseline. No patient developed symptoms or sustained a complete fracture on the contralateral side. Radiographic remodeling occurred independently of symptoms. BP discontinuation and, when tolerated, teriparatide appeared to contribute to lesion stabilization, although statistical significance was not achieved. Conclusions: In autoimmune patients with severe long-term BP and GC exposure, most asymptomatic incomplete AFF identified at the time of contralateral complete fracture remains stable or improves under conservative management. A transverse radiolucent line is the most decisive imaging biomarker predictive of progression and warrants intensified surveillance or consideration of prophylactic fixation. Larger cohorts are needed to refine risk stratification algorithms and optimize diagnostic and management strategies.

  • Open Access

    Femoral stress distribution in fully hydroxyapatite-coated cementless versus polished cemented stems with identical geometry: a thermoelastic stress analysis

    by Ryunosuke Watanabe, Hajime Mishima, Shota Yasunaga, Tomohiro Yoshizawa, Tomofumi Nishino, Yoshihisa Harada

    Stress shielding and altered load transfer remain major concerns in total hip arthroplasty (THA). Stem fixation method and material properties strongly influence femoral stress distribution, but data directly comparing cementless and cemented stems of identical geometry are limited. Six fourth-generation composite femurs were used. Three were implanted with a fully hydroxyapatite-coated cementless stem, and three with a polished cemented stem. Mechanical loading of 100-1900 N at 5 Hz was applied to simulate single-leg stance. Thermoelastic stress analysis (TSA) was used to evaluate surface stress distribution across Gruen zones. Linear mixed models assessed differences between groups. Before implantation, the highest stress was observed in the proximal femur. After implantation, stress shifted distally in both fixation methods. The cementless stem maintained higher compressive stress in the proximal-medial region compared with the cemented stem, which demonstrated a more uniform stress distribution between the medial and lateral cortices. TSA measurements confirmed significant proximal stress reduction with cemented fixation, while cementless fixation preserved proximal loading more effectively. This simulation study showed that fixation method and material influence short-term femoral stress distribution, even when stem geometry is identical. These findings describe only mechanical behavior under simplified conditions. The use of composite femurs, the one-size difference between stems, and the short-term evaluation limit the generalizability of the results. Further research using cadaveric models and clinical follow-up is required to clarify long-term remodeling and support stem selection in total hip arthroplasty.

  • Open Access

    Biomechanical comparison of cemented versus cementless fixation in intraoperative femoral fractures during total hip arthroplasty

    by Ryunosuke Watanabe, Tomofumi Nishino, Tomohiro Yoshizawa, Fumi Hirose, Shota Yasunaga, Koshiro Shimasaki, Hajime Mishima

    Introduction: Intraoperative periprosthetic femoral fractures (IPFF) are serious complications of total hip arthroplasty (THA) that occur more frequently with cementless stems than with cemented stems. Although cerclage wiring is commonly used to stabilize IPFFs, the biomechanical effects of subsequent stem fixation methods remain unclear. This study aimed to compare the biomechanical stability of cemented and cementless stems following cerclage wire fixation in an experimental IPFF model. Materials and methods: Six fourth-generation composite femurs with simulated Vancouver A2-type fractures were stabilized using a single 1.8 mm cerclage wire. Identical stem designs of polished cemented stems and fully hydroxyapatite-coated cementless stems were implanted in three specimens of each group. After applying a vertical axial load of 2000 N, an additional 40° of internal rotation was imposed. The primary outcome was the maximum torque at the time of fracture. Secondary outcomes included the maximum internal rotation angle, construct stiffness (calculated from force-displacement curves above 1500 N), and peak strain at three positions on the cerclage wire, measured using strain gauges. Results: The maximum torque was significantly higher in the cemented group compared to the cementless group (160.8 ± 24.9 vs. 89.1 ± 18.0 N·m, p = 0.016). Although the differences in stiffness and internal rotation angle were not statistically significant, both trended higher in the cemented group. The peak strain was consistently lower in the cemented group, with a significant difference at the medial side of the fracture line ( p = 0.011, Cohen’s d = − 3.64). Conclusions: Cemented stems demonstrated superior biomechanical stability following cerclage wire fixation in the IPFF model, likely because of improved stress distribution via the cement mantle. Therefore, cemented fixation may be a favorable option for managing IPFF during THA.


  • Open Access

    Bone wax spacers increase induced membrane thickness and promote osteogenesis more than polymethylmethacrylate spacers in the masquelet technique

    by Takushi Nakatani, Hajime Mishima, Sho Totsuka, Ryunosuke Watanabe, Norihito Arai, Yohei Tomaru, Hisashi Sugaya, Tomofumi Nishino, Masashi Yamazaki

    Purpose: The Masquelet technique is a recent novel treatment for severe bone defects. Polymethylmethacrylate (PMMA) has been used as a spacer for bone defects, but the optimal spacer is still unknown. Therefore, this study aimed to histologically evaluate the membranes induced by bone wax and PMMA spacers and compare them with respect to bone formation. Methods: In this study, bone defects were created in the femurs of Sprague–Dawley rats, and bone wax and PMMA spacers were implanted into the defects to histologically evaluate the induced membrane and bone formation after bone grafting. Results: As a result, the induced membrane formed by bone wax spacers was significantly thicker than that formed by PMMA spacers, and the vascular area ratio was significantly higher. In addition, bone wax spacers promoted bone formation more than PMMA spacers. Conclusion: Bone wax spacers promoted induced membrane formation and bone formation by enhancing inflammatory responses more than PMMA spacers.


  • Open Access

    Optimizing Stem Length in Conversion Total Hip Arthroplasty: An Expanded Finite Element Analysis

    by Koshiro Shimasaki, Tomofumi Nishino, Tomohiro Yoshizawa, Ryunosuke Watanabe, Fumi Hirose, Shota Yasunaga, Hajime Mishima

    Background/Objectives: Stress concentration around distal screw-removal holes confers a major risk for periprosthetic fractures following conversion total hip arthroplasty (cTHA) for intertrochanteric femoral fractures. Optimal stem-selection criteria and guidelines for cTHA can improve clinical outcomes. We determined the influence of the cementless stem length on the stress distribution around distal screw-removal holes. Methods: For the finite element analysis, institutional data from preoperative CT scans of contralateral femurs of patients who underwent THA were used. To replicate the post-nail-removal state, we used 3D registration of standard triangulated language data of the intramedullary nail as an unused material to simulate distal screw-removal holes, located 135 mm from the proximal end of the intramedullary nail. Cementless stems of 130, 140, 150, and 160 mm were individually registered using STL data, and cTHA models were constructed accordingly. Using simulations under load conditions representing normal walking and stair climbing, the mean and maximum equivalent stress values around the distal screw-removal holes were calculated. For multiple comparisons, repeated-measures ANOVA with Bonferroni correction was employed. Results: Compared to the 130 mm stem, the 150 mm and 160 mm stems similarly reduced the maximum equivalent stress around the distal screw-removal holes, although the 140 mm stem showed no significant difference with other stems. Conclusions: A ≥150 mm stem length reliably mitigated stress concentration around distal screw-removal holes post-cTHA; it is the optimal choice for balancing effectiveness and risk of complications and may contribute to improved long-term clinical outcomes. This study provides practical evidence for stem selection in cTHA and offers valuable insights for future treatment guidelines.


  • Open Access

    Optimizing Stem Length in Conversion Hip Arthroplasty: An Expanded Finite Element Analysis

    by Koshiro Shimasaki, Tomofumi Nishino, Tomohiro Yoshizawa, Ryunosuke Watanabe, Fumi Hirose, Shota Yasunaga, Hajime Mishima

    Background/Objectives: Stress concentration around distal screw-removal holes confers a major risk for periprosthetic fractures following conversion total hip arthroplasty (cTHA) for intertrochanteric femoral fractures. Optimal stem-selection criteria and guidelines for cTHA can improve clinical outcomes. We determined the influence of cementless stem length on stress distribution around distal screw-removal holes. Methods: For finite element analysis, institutional data from preoperative CT scans of contralateral femurs of patients who underwent THA were used. To replicate the post-nail-removal state, we used 3D registration of Standard Triangulated Language data of the intramedullary nail as an unused material to simulate distal screw-removal holes, located 135 mm from the proximal end of the intramedullary nail. Cementless stems of 130, 140, 150, and 160 mm were individually registered using STL data, and cTHA models were constructed accordingly. Using simulations under load conditions representing normal walking and stair climbing, the mean and maximum equivalent stress values around the distal screw-removal holes were calculated. Repeated-measures ANOVA with Bonferroni correction was used for multiple comparisons. Results: Compared to the 130-mm stem, the 150-mm and 160-mm stems similarly reduced the maximum equivalent stress around distal screw-removal holes, although the 140-mm stem showed no significant difference with other stems. Conclusions: A ≥150-mm stem length reliably mitigates stress concentration around distal screw-removal holes post-cTHA, is the optimal choice for balancing effectiveness and risk of complications, and may contribute to improved long-term clinical outcomes. This study provides practical evidence for stem selection in cTHA and offers valuable insights for future treatment guidelines.