Elif Kalyoncuoğlu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Elif Kalyoncuoğlu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Cangül Keskin
Department of Endodontics, Faculty of Dentistry, Ondokuz Mayıs University, Samsun, Türkiye
2 shared publications Ebru Özsezer Demiryürek
Department of Endodontics, Faculty of Dentistry, Ondokuz Mayis University, Samsun - Turkey
2 shared publicationsAli Keleş
Department of Endodontics, Ondokuz Mayıs University, Samsun, Turkey
1 shared publication- Ali Keleş
Department of Endodontics, Faculty of Dentistry, Bolu Abant Izzet Baysal University, Bolu 14030, Türkiye
1 shared publication Cangül Keskin
Department of Endodontics, Ondokuz Mayıs University, Samsun, Turkey
1 shared publication- Duygu Hazal Acar
Ondokuz Mayis University
1 shared publication
Latest Publications
- 23 December 2022
- Published by Elsevier in Journal of Endodontics
- Vol. 49 (2) , 212-218
Efficacy of Endoscope and Periapical Radiography to Detect Residual Root Canal Filling Using Micro-CT as Reference
- 23 December 2022
- Published by Elsevier in Journal of Endodontics
- Vol. 49 (2) , 212-218
Efficacy of Endoscope and Periapical Radiography to Detect Residual Root Canal Filling Using Micro-CT as Reference
- 20 October 2021
- Published by Wiley in Australian Endodontic Journal
- Vol. 48 (1) , 121-130
Metallurgical characterisation and torsional resistance of blue thermomechanically treated nickel titanium instruments after simulated ex vivo retreatment procedure
To compare used and unused Reciproc Blue and Reciproc after retreatment, the instruments were used in the mesiobuccal canals of maxillary molars with curvature. The torsional resistances were tested and then unused instruments were subjected to XRD, DSC and microhardness tests. Student’s t, ANOVA and Tukey’s tests were performed (α-level 0.05). The torsional strength of used Reciproc Blue was not significantly different than unused ones (P > .05), while torsional strength of Reciproc decreased significantly (P < .05). DSC and XRD indicated that Reciproc Blue exhibited prominent transformation peaks corresponding austenite to R-phase. Microhardness of Reciproc was significantly higher (P < .05). A second reuse of Reciproc Blue for retreatment could be considered safe in terms of torsional strength. Blue treatment also decreased surface microhardness of the instrument and changed phase composition by increasing the R-phase.
- 20 October 2021
- Published by Wiley in Australian Endodontic Journal
- Vol. 48 (1) , 121-130
Metallurgical characterisation and torsional resistance of blue thermomechanically treated nickel titanium instruments after simulated ex vivo retreatment procedure
To compare used and unused Reciproc Blue and Reciproc after retreatment, the instruments were used in the mesiobuccal canals of maxillary molars with curvature. The torsional resistances were tested and then unused instruments were subjected to XRD, DSC and microhardness tests. Student’s t, ANOVA and Tukey’s tests were performed (α-level 0.05). The torsional strength of used Reciproc Blue was not significantly different than unused ones (P > .05), while torsional strength of Reciproc decreased significantly (P < .05). DSC and XRD indicated that Reciproc Blue exhibited prominent transformation peaks corresponding austenite to R-phase. Microhardness of Reciproc was significantly higher (P < .05). A second reuse of Reciproc Blue for retreatment could be considered safe in terms of torsional strength. Blue treatment also decreased surface microhardness of the instrument and changed phase composition by increasing the R-phase.
- 31 March 2021
- Published by Marmara University in Clinical and Experimental Health Sciences
- Vol. 11 (1) , 170-174
The Bond Strength of Universal Adhesives with Different Acidities to Calcium Silicate-Based Materials
Objective: To compare the micro-shear bond strengths of 3 different universal adhesives to 2 different calcium silicate-based materials. Methods: A hole was prepared in the center of the top surfaces of 60 cylindrical acrylic blocks, and the blocks were randomly divided into 2 groups (n=30) according to biomaterial filling; NeoMTA Plus (Avalon Biomed Inc. Bradenton, FL, USA) and ProRoot MTA (Dentsply Tulsa, Tulsa, OK, USA). Biomaterials were prepared according to the manufacturers’ instructions. The sample surfaces were flattened after the initial setting, and the samples were incubated for 24h at 37°C. After placing the biomaterials in the prepared holes, the specimens were randomly divided into 3 subgroups (n=10) according to adhesive; G-Premio Bond (GC Corp., Tokyo, Japan), All-Bond Universal (Bisco, Inc., Schaumburg, IL, USA) and Single Bond Universal (3M ESPE, St Paul, MN, USA). Adhesives were applied to the specimens and polymerized. A micro-hybrid composite resin (Filtek Z250, 3M ESPE, MN, USA) was then placed on the specimen surfaces and polymerized. Micro-shear bond strengths were tested using a universal testing device (LRX, Lloyd Instruments, Farnham, UK). A Shapiro-Wilk test confirmed normal distribution, and 2-way ANOVA was used for statistical analysis. Result: No significant differences were found in the shear bond strengths of any of the tested adhesives to either of the calcium silicate-based materials (p>0.05). Conclusion: The results indicate that the acidity of a universal adhesive does not affect the bond strength of composite resin to calcium silicate-based materials.
- 31 March 2021
- Published by Marmara University in Clinical and Experimental Health Sciences
- Vol. 11 (1) , 170-174
The Bond Strength of Universal Adhesives with Different Acidities to Calcium Silicate-Based Materials
Objective: To compare the micro-shear bond strengths of 3 different universal adhesives to 2 different calcium silicate-based materials. Methods: A hole was prepared in the center of the top surfaces of 60 cylindrical acrylic blocks, and the blocks were randomly divided into 2 groups (n=30) according to biomaterial filling; NeoMTA Plus (Avalon Biomed Inc. Bradenton, FL, USA) and ProRoot MTA (Dentsply Tulsa, Tulsa, OK, USA). Biomaterials were prepared according to the manufacturers’ instructions. The sample surfaces were flattened after the initial setting, and the samples were incubated for 24h at 37°C. After placing the biomaterials in the prepared holes, the specimens were randomly divided into 3 subgroups (n=10) according to adhesive; G-Premio Bond (GC Corp., Tokyo, Japan), All-Bond Universal (Bisco, Inc., Schaumburg, IL, USA) and Single Bond Universal (3M ESPE, St Paul, MN, USA). Adhesives were applied to the specimens and polymerized. A micro-hybrid composite resin (Filtek Z250, 3M ESPE, MN, USA) was then placed on the specimen surfaces and polymerized. Micro-shear bond strengths were tested using a universal testing device (LRX, Lloyd Instruments, Farnham, UK). A Shapiro-Wilk test confirmed normal distribution, and 2-way ANOVA was used for statistical analysis. Result: No significant differences were found in the shear bond strengths of any of the tested adhesives to either of the calcium silicate-based materials (p>0.05). Conclusion: The results indicate that the acidity of a universal adhesive does not affect the bond strength of composite resin to calcium silicate-based materials.
- Open Access
- 1 October 2015
- Published by SAGE Publications in Journal of Applied Biomaterials & Functional Materials
- Vol. 13 (4) , 362-366
Effect of Propolis as a Root Canal Irrigant on Bond Strength to Dentin
Purpose: The purpose of this in vitro study was to evaluate the effect of propolis on bond strength to dentin of a self-etch adhesive when used as a final irrigant. Methods: 126 human third molars were sectioned 3 mm below the occlusal level and then randomly divided into 7 groups (n = 18). The exposed dentin surfaces were treated with irrigation solutions as follows: Group 1: 5.25% NaOCl; Group 2: 5.25% NaOCl followed by 17% EDTA; Group 3: 5.25% NaOCl followed by Tubulicid Plus (Temrex, Freeport, NY, USA); Group 4: 5.25% NaOCl followed by MTAD; Group 5: 5.25% NaOCl followed by 20% propolis; Group 6: 5.25% NaOCl followed by 2% CHX; Group 7: distilled water (control). Irrigated specimens were bonded using Clearfil SE Bond (Kuraray, Osaka, Japan) with Tygon (Saint-Gobain, Saint-Gobain Performance Plastics, France), tubes for microshear bond strength testing. Data was analyzed using a one-way ANOVA and Tukey test. Results: Among the tested groups, although the lowest bond strength values were detected in Group 1 (11.25 ± 1.97), a significant statistical difference was detected only between this group and Group 4 (18.70 ± 1.82) and Group 5 (16.75 ± 3.70) (p = 0.0012). Conclusions: 20% propolis solution as a final irrigant was found to have a favorable effect on the dentin bond strength of the tested self-etch adhesive to coronal dentin when compared with other irrigation solutions.
- 1 October 2015
- Published by SAGE Publications in Journal of Applied Biomaterials & Functional Materials
- Vol. 13 (4) , 362-366
Open AccessEffect of Propolis as a Root Canal Irrigant on Bond Strength to Dentin
Purpose: The purpose of this in vitro study was to evaluate the effect of propolis on bond strength to dentin of a self-etch adhesive when used as a final irrigant. Methods: 126 human third molars were sectioned 3 mm below the occlusal level and then randomly divided into 7 groups (n = 18). The exposed dentin surfaces were treated with irrigation solutions as follows: Group 1: 5.25% NaOCl; Group 2: 5.25% NaOCl followed by 17% EDTA; Group 3: 5.25% NaOCl followed by Tubulicid Plus (Temrex, Freeport, NY, USA); Group 4: 5.25% NaOCl followed by MTAD; Group 5: 5.25% NaOCl followed by 20% propolis; Group 6: 5.25% NaOCl followed by 2% CHX; Group 7: distilled water (control). Irrigated specimens were bonded using Clearfil SE Bond (Kuraray, Osaka, Japan) with Tygon (Saint-Gobain, Saint-Gobain Performance Plastics, France), tubes for microshear bond strength testing. Data was analyzed using a one-way ANOVA and Tukey test. Results: Among the tested groups, although the lowest bond strength values were detected in Group 1 (11.25 ± 1.97), a significant statistical difference was detected only between this group and Group 4 (18.70 ± 1.82) and Group 5 (16.75 ± 3.70) (p = 0.0012). Conclusions: 20% propolis solution as a final irrigant was found to have a favorable effect on the dentin bond strength of the tested self-etch adhesive to coronal dentin when compared with other irrigation solutions.
- 1 July 2015
- Published by SAGE Publications in Journal of Applied Biomaterials & Functional Materials
- Vol. 13 (3) , 253-258
Effect of 1-Piece Post and Core Fabrication Techniques on Fracture Strength
Purpose: The purpose of this in vitro study was to evaluate and compare the fracture strengths of post and core systems produced with different fabrication techniques and materials. Methods: Forty extracted human single-root premolars were used in this study. After root canal treatment, the teeth were randomly divided into 4 groups of 10 each as follows: group C: metallic 1-piece posts and cores fabricated by casting, and serving as the control; group CM: metallic posts and cores fabricated with the copy milled technique; group LS: 1-piece posts and cores fabricated with the laser sintering technique; and group ZR: 1-piece zirconia posts and cores fabricated with computer-aided design and computer-aided manufacturing (CAD-CAM). The posts and cores were cemented to the teeth with adhesive resin cement; then, the specimens were mounted to acrylic resin blocks, attached to an Instron Universal Testing Machine, and loaded with a crosshead speed of 1 mm/min, until fracture. Data were statistically analyzed using 1-way analysis of variance (ANOVA), followed by the post hoc Tukey test (α = 0.05). Results: The highest fracture results were found in group ZR (315.4 ± 53.4 N), which showed significant differences from all other groups (p0.05). Conclusions: Custom-made zirconia 1-piece posts and cores, fabricated using the CAD-CAM procedure, can be an alternative treatment method when compared with other techniques.
- 1 July 2015
- Published by SAGE Publications in Journal of Applied Biomaterials & Functional Materials
- Vol. 13 (3) , 253-258
Effect of 1-Piece Post and Core Fabrication Techniques on Fracture Strength
Purpose: The purpose of this in vitro study was to evaluate and compare the fracture strengths of post and core systems produced with different fabrication techniques and materials. Methods: Forty extracted human single-root premolars were used in this study. After root canal treatment, the teeth were randomly divided into 4 groups of 10 each as follows: group C: metallic 1-piece posts and cores fabricated by casting, and serving as the control; group CM: metallic posts and cores fabricated with the copy milled technique; group LS: 1-piece posts and cores fabricated with the laser sintering technique; and group ZR: 1-piece zirconia posts and cores fabricated with computer-aided design and computer-aided manufacturing (CAD-CAM). The posts and cores were cemented to the teeth with adhesive resin cement; then, the specimens were mounted to acrylic resin blocks, attached to an Instron Universal Testing Machine, and loaded with a crosshead speed of 1 mm/min, until fracture. Data were statistically analyzed using 1-way analysis of variance (ANOVA), followed by the post hoc Tukey test (α = 0.05). Results: The highest fracture results were found in group ZR (315.4 ± 53.4 N), which showed significant differences from all other groups (p0.05). Conclusions: Custom-made zirconia 1-piece posts and cores, fabricated using the CAD-CAM procedure, can be an alternative treatment method when compared with other techniques.
- 9 August 2013
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 19 (6) , 1465-1469
A Comparative Scanning Electron Microscopy Evaluation of Smear Layer Removal from Teeth with Different Irrigation Solutions and Lasers
The aim of this study was to evaluate the efficacy of smear layer removal from teeth following root canals using lasers (Er:YAG and Nd:YAG), NaOCl, 17% EDTA, and MTAD by scanning electron microscopy (SEM). Root canals were irrigated with 3 mL of 5.25% NaOCl after each file. Teeth were randomly divided into five groups. In the final irrigation, canals were irrigated with 5.25% NaOCl (Group 1, control), 17% EDTA (Group 2), or BioPure MTAD (Group 3). Laser groups were irradiated with Er:YAG laser (1.8 W, 120 mJ, 15 Hz) (Group 4) or Nd:YAG laser (1 W, 100 mJ, 15 Hz) (Group 5). The smear layer at the apical, middle, and coronal thirds of each root canal was imaged using SEM. Smear layer removal by EDTA was the most effective in all regions. The difference between EDTA and MTAD was statistically significant in the coronal and middle (p < 0.05), but not the apical (p > 0.05), regions. The difference between the control and laser groups was not statistically significant (p > 0.05). In all regions, the difference between 17% EDTA–MTAD and the control–laser groups was statistically significant (p < 0.05). Although improvement was observed in removal of the smear layer using alternative materials and techniques, application of a combination of EDTA and NaOCl remains an effective technique.
- 9 August 2013
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 19 (6) , 1465-1469
A Comparative Scanning Electron Microscopy Evaluation of Smear Layer Removal from Teeth with Different Irrigation Solutions and Lasers
The aim of this study was to evaluate the efficacy of smear layer removal from teeth following root canals using lasers (Er:YAG and Nd:YAG), NaOCl, 17% EDTA, and MTAD by scanning electron microscopy (SEM). Root canals were irrigated with 3 mL of 5.25% NaOCl after each file. Teeth were randomly divided into five groups. In the final irrigation, canals were irrigated with 5.25% NaOCl (Group 1, control), 17% EDTA (Group 2), or BioPure MTAD (Group 3). Laser groups were irradiated with Er:YAG laser (1.8 W, 120 mJ, 15 Hz) (Group 4) or Nd:YAG laser (1 W, 100 mJ, 15 Hz) (Group 5). The smear layer at the apical, middle, and coronal thirds of each root canal was imaged using SEM. Smear layer removal by EDTA was the most effective in all regions. The difference between EDTA and MTAD was statistically significant in the coronal and middle (p < 0.05), but not the apical (p > 0.05), regions. The difference between the control and laser groups was not statistically significant (p > 0.05). In all regions, the difference between 17% EDTA–MTAD and the control–laser groups was statistically significant (p < 0.05). Although improvement was observed in removal of the smear layer using alternative materials and techniques, application of a combination of EDTA and NaOCl remains an effective technique.