Norman Werther
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Norman Werther has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Thomas Engel
Technische Universität München TUM School of Engineering and Design Lehrstuhl für Holzbau und Baukonstruktion Arcisstraße 21 80333 München
6 shared publications - Stefan Winter
Chair of Timber Structures and Building Construction, TUM School of Engineering and Design, Technical University of Munich, Arcisstraße 21, 80333 Munich, Germany
5 shared publications - Joachim Schmid
ETH Zürich Institut für Baustatik und Konstruktion Stefano‐Franscini‐Platz 5 8093 Zürich Schweiz
2 shared publications - Jochen Zehfuß
Technische Universität Braunschweig
2 shared publications - Michael Klippel
ETH Zürich Institut für Baustatik und Konstruktion Stefano‐Franscini‐Platz 5 8093 Zürich Schweiz
2 shared publications - Reto Fahrni
ETH Zürich Institut für Baustatik und Konstruktion – IBK Stefano-Franscini Platz 5 8093 Zürich Schweiz
2 shared publications
Latest Publications
- 1 June 2024
- Published by Springer Nature
- p. 326-333
Fire Safety Design of Structures in Steel-Timber Hybrid Construction
- 1 June 2024
- Published by Springer Nature
- p. 326-333
Fire Safety Design of Structures in Steel-Timber Hybrid Construction
- Open Access
- 22 April 2024
- Published by Springer Nature in Fire Technology
- Vol. 60 (3) , 2177-2230
Fire Safety for Green Façades: Part 1: Basics, State-of-the-Art Research and Experimental Investigation of Plant Flammability
This study is the first part of a larger investigation into the fire behaviour of green façades. In this study, the currently known international research status on this topic is presented and discussed. In addition, the flammability of green façades is investigated through 43 fire tests on a medium scale according to the SBI (Single Burning Item) test method EN 13823. The focus of the investigation was placed on climbing plants. A total of 25 different plant species were investigated. A comparison of the heat release rate of all the investigated vital plants shows similar behaviour. In the course of exposure, there are short peaks in the heat release rate. These peaks are “flare-ups” that occur when parts of the plants dry out due to exposure to the flame and then ignite. The plant species itself had no substantial influence on fire behaviour. Horizontal fire spread occurred to a very limited extent within the investigations of vital plants. They were self-extinguishing. The significant factor in the assessment of flammability is the moisture content of the plants. With dried plants, an abrupt heat release occurs at the beginning. Dried-out plants, as well as unmaintained plants with a high content of deadwood, represent the most critical case. Graphical Abstract
- 22 April 2024
- Published by Springer Nature in Fire Technology
- Vol. 60 (3) , 2177-2230
Open AccessFire Safety for Green Façades: Part 1: Basics, State-of-the-Art Research and Experimental Investigation of Plant Flammability
This study is the first part of a larger investigation into the fire behaviour of green façades. In this study, the currently known international research status on this topic is presented and discussed. In addition, the flammability of green façades is investigated through 43 fire tests on a medium scale according to the SBI (Single Burning Item) test method EN 13823. The focus of the investigation was placed on climbing plants. A total of 25 different plant species were investigated. A comparison of the heat release rate of all the investigated vital plants shows similar behaviour. In the course of exposure, there are short peaks in the heat release rate. These peaks are “flare-ups” that occur when parts of the plants dry out due to exposure to the flame and then ignite. The plant species itself had no substantial influence on fire behaviour. Horizontal fire spread occurred to a very limited extent within the investigations of vital plants. They were self-extinguishing. The significant factor in the assessment of flammability is the moisture content of the plants. With dried plants, an abrupt heat release occurs at the beginning. Dried-out plants, as well as unmaintained plants with a high content of deadwood, represent the most critical case. Graphical Abstract
- 22 December 2023
- Published by Wiley in Bautechnik
- Vol. 101 (1) , 21-28
Hintergründe und Grundlagen zur Anwendung von Brandschutzbekleidungen im Holzbau
- 22 December 2023
- Published by Wiley in Bautechnik
- Vol. 101 (1) , 21-28
Hintergründe und Grundlagen zur Anwendung von Brandschutzbekleidungen im Holzbau
- 18 September 2023
- Published by Wiley in Bautechnik
- Vol. 100 (10) , 599-607
Hintergründe und Nachweisgrundlagen zur Brandschutzbemessung von Brettsperrholzkonstruktionen – Teil 2
- 18 September 2023
- Published by Wiley in Bautechnik
- Vol. 100 (10) , 599-607
Hintergründe und Nachweisgrundlagen zur Brandschutzbemessung von Brettsperrholzkonstruktionen – Teil 2
- Open Access
- 13 December 2022
- Published by Springer Nature in Fire Technology
- Vol. 59 (2) , 517-558
Impact of Mass Timber Compartment Fires on Façade Fire Exposure
This study investigates whether timber surfaces that are initially exposed to fire or partially protected timber components can lead to a more critical fire exposure on the façade. Five full-scale fire tests were carried out. Three tests with a square compartment (4.5 × 4.5 m2) and two with a double-width compartment (4.5 × 9 m2). The tests were conducted with a high fire load density (1085 MJ/m2). While the first test was carried out in a non-combustible compartment, the exposed timber surfaces were subsequently increased in the other tests. The measured compartment gas temperature, heat release rate, temperature on the façade, flame heights along the façade, heat flux and velocities along the façade are presented in this publication. The influence of exposed or only initially protected timber surfaces on the fire impact on the façade is investigated with the help of these results. Finally, these findings are presented and compared with the results of other internationally conducted fire tests from literature. Additional structural fire load leads to an increase in temperatures on the façade. However, there is no significant difference in flame height between the tests. Another result was that an exposed mass timber ceiling leads to higher heat fluxes on the façade than an exposed mass timber wall. Graphical Abstract
- 13 December 2022
- Published by Springer Nature in Fire Technology
- Vol. 59 (2) , 517-558
Open AccessImpact of Mass Timber Compartment Fires on Façade Fire Exposure
This study investigates whether timber surfaces that are initially exposed to fire or partially protected timber components can lead to a more critical fire exposure on the façade. Five full-scale fire tests were carried out. Three tests with a square compartment (4.5 × 4.5 m2) and two with a double-width compartment (4.5 × 9 m2). The tests were conducted with a high fire load density (1085 MJ/m2). While the first test was carried out in a non-combustible compartment, the exposed timber surfaces were subsequently increased in the other tests. The measured compartment gas temperature, heat release rate, temperature on the façade, flame heights along the façade, heat flux and velocities along the façade are presented in this publication. The influence of exposed or only initially protected timber surfaces on the fire impact on the façade is investigated with the help of these results. Finally, these findings are presented and compared with the results of other internationally conducted fire tests from literature. Additional structural fire load leads to an increase in temperatures on the façade. However, there is no significant difference in flame height between the tests. Another result was that an exposed mass timber ceiling leads to higher heat fluxes on the façade than an exposed mass timber wall. Graphical Abstract
- Open Access
- 21 July 2022
- Published by Taylor & Francis
- p. 317-344
Prevention of fire spread within structures
This chapter describes means of preventing spread of fire and smoke between compartments in timber buildings. Much of this applies to all buildings independent of materials used, but some topics are especially relevant for timber buildings. This chapter highlights critical paths of possible spread of fire into, within and through timber structures, including solutions and detailing to prevent uncontrolled spread of fire and smoke.
- 21 July 2022
- Published by Taylor & Francis
- p. 317-344
Open AccessPrevention of fire spread within structures
This chapter describes means of preventing spread of fire and smoke between compartments in timber buildings. Much of this applies to all buildings independent of materials used, but some topics are especially relevant for timber buildings. This chapter highlights critical paths of possible spread of fire into, within and through timber structures, including solutions and detailing to prevent uncontrolled spread of fire and smoke.
- 15 July 2022
- Published by Wiley in Bautechnik
- Vol. 99 (8) , 587-593
Hintergründe und Nachweisgrundlagen zur Brandschutzbemessung von Brettsperrholzkonstruktionen – Teil 1
- 15 July 2022
- Published by Wiley in Bautechnik
- Vol. 99 (8) , 587-593
Hintergründe und Nachweisgrundlagen zur Brandschutzbemessung von Brettsperrholzkonstruktionen – Teil 1
- Open Access
- 22 October 2021
- Published by Springer Nature in Fire Technology
- Vol. 59 (1) , 117-151
Structural Means for Fire-Safe Wooden Façade Design
This study investigates five fire stop variants used to limit the spread of fire on wooden façades. For this purpose, five fire tests using various types of wooden façade claddings and different fire stops were conducted as full-scale tests and compared to the existing findings. The influences and interactions between the material qualities of the external wall behind the façade cladding, the construction type of the wooden façade cladding, the design of the substructure, the depth of the ventilation gap, and the design of the fire stops were investigated. In evaluating the fire stops, the design of the interior corners, the joint design, and the influence of thermal expansion were examined. Finally, design proposals for the design of fire stops at wooden façades in order to limit the spread of fire were derived based on this evaluation. The outlook presents further needs that need to be investigated in the future in order to clarify undiscussed aspects or points that were ultimately not evaluated within the scope of this study. Graphical Abstract
- 22 October 2021
- Published by Springer Nature in Fire Technology
- Vol. 59 (1) , 117-151
Open AccessStructural Means for Fire-Safe Wooden Façade Design
This study investigates five fire stop variants used to limit the spread of fire on wooden façades. For this purpose, five fire tests using various types of wooden façade claddings and different fire stops were conducted as full-scale tests and compared to the existing findings. The influences and interactions between the material qualities of the external wall behind the façade cladding, the construction type of the wooden façade cladding, the design of the substructure, the depth of the ventilation gap, and the design of the fire stops were investigated. In evaluating the fire stops, the design of the interior corners, the joint design, and the influence of thermal expansion were examined. Finally, design proposals for the design of fire stops at wooden façades in order to limit the spread of fire were derived based on this evaluation. The outlook presents further needs that need to be investigated in the future in order to clarify undiscussed aspects or points that were ultimately not evaluated within the scope of this study. Graphical Abstract
- 1 May 2021
- Published by Wiley in Bautechnik
- Vol. 98 (5) , 353-364
Fire hazard due to electrical installations in modern multi-storey timber buildings
- 1 May 2021
- Published by Wiley in Bautechnik
- Vol. 98 (5) , 353-364
Fire hazard due to electrical installations in modern multi-storey timber buildings
- 1 November 2020
- Published by Wiley in Bautechnik
- Vol. 97 (S2) , 97-107
TIMpuls basic research on fire protection in timber construction: charring rate, protection times of claddings and post-burning behaviour of timber
- 1 November 2020
- Published by Wiley in Bautechnik
- Vol. 97 (S2) , 97-107
TIMpuls basic research on fire protection in timber construction: charring rate, protection times of claddings and post-burning behaviour of timber