Joseph Reidy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Joseph Reidy has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Ralph Jasper Mobbs
Faculty of Medicine, University of New South Wales (UNSW), Sydney, Australia
4 shared publications Alice Ma
Department of Neurosurgery, Royal North Shore Hospital, St Leonards, NSW, Australia
3 shared publications- Alison Ma
Faculty of Medicine, University of New South Wales, Sydney, NSW 2033, Australia; NeuroSpine Surgery Research Group (NSURG), Randwick, NSW 2031, Australia
3 shared publications Brendan Steinfort
Department of Neurosurgery, Royal North Shore Hospital, St Leonards, NSW, Australia
3 shared publicationsKenneth Faulder
Department of Neurosurgery, Royal North Shore Hospital, St Leonards, Sydney, Australia
2 shared publicationsKeryn Davidson
Department of Neurosurgery, Royal North Shore Hospital, St Leonards, Sydney, Australia
2 shared publications
Latest Publications
- Open Access
- 1 June 2026
- Published by AME Publishing Company in Journal of Spine Surgery
- Vol. 12 (6) , 98
Evaluating the advantages and limitations of three-dimensional (3D) endoscopy as an innovative tool in spine surgery for degenerative pathologies: a case series
Background: Endoscopic spine surgery reduces tissue damage, blood loss and postoperative pain. However, the two-dimensional (2D) view prevents depth perception and spatial orientation, contributing to a steep learning curve. Three-dimensional (3D) endoscopes improve depth perception but introduce increased scope diameter, workflow disruption and reduced image quality. A novel algorithm-based 3D visualisation system enables real-time conversion of standard 2D endoscopic images into 3D without requiring a dedicated 3D endoscope. Its impact on surgical workflow and intraoperative performance in spine surgery remains unknown. Case Description: 14 patients with degenerative spinal pathology underwent endoscopic surgery using a real-time 2D-to-3D conversion system (13 uniportal, 1 biportal). Outcomes were assessed across predefined domains: (I) visualisation; (II) instrument handling; (III) haemostasis; (IV) educational impact; (V) workflow; and (VI) ergonomics. Improved visualisation (depth perception and spatial orientation) were observed in all cases. Improved instrument handling (navigation and drill control) was observed in all decompression cases (10/10). Enhanced haemostasis recognition was reported in 6/10 applicable cases. Educational benefit was observed in 6/14 cases. Workflow disruption occurred in 4/14 cases and ergonomic symptoms (mild dizziness or double vision) were reported in 6/14 cases. Field of view was equivalent between 2D and 3D imaging. No dural injuries, neurological deficits or reoperations occurred. All patients demonstrated recovery consistent with expected postoperative trajectories. Conclusions: This case series demonstrates the potential for 3D endoscopy to be used as an adjunct in endoscopic spine surgery with improvements in depth perception, instrument handling and visualisation of spatial relationships without altering endoscope diameter or access corridors. While an initial familiarisation phase is required, the system demonstrates potential workflow and educational value. Further prospective studies with quantitative metrics and long-term outcomes are warranted.
- 1 June 2026
- Published by AME Publishing Company in Journal of Spine Surgery
- Vol. 12 (6) , 98
Open AccessEvaluating the advantages and limitations of three-dimensional (3D) endoscopy as an innovative tool in spine surgery for degenerative pathologies: a case series
Background: Endoscopic spine surgery reduces tissue damage, blood loss and postoperative pain. However, the two-dimensional (2D) view prevents depth perception and spatial orientation, contributing to a steep learning curve. Three-dimensional (3D) endoscopes improve depth perception but introduce increased scope diameter, workflow disruption and reduced image quality. A novel algorithm-based 3D visualisation system enables real-time conversion of standard 2D endoscopic images into 3D without requiring a dedicated 3D endoscope. Its impact on surgical workflow and intraoperative performance in spine surgery remains unknown. Case Description: 14 patients with degenerative spinal pathology underwent endoscopic surgery using a real-time 2D-to-3D conversion system (13 uniportal, 1 biportal). Outcomes were assessed across predefined domains: (I) visualisation; (II) instrument handling; (III) haemostasis; (IV) educational impact; (V) workflow; and (VI) ergonomics. Improved visualisation (depth perception and spatial orientation) were observed in all cases. Improved instrument handling (navigation and drill control) was observed in all decompression cases (10/10). Enhanced haemostasis recognition was reported in 6/10 applicable cases. Educational benefit was observed in 6/14 cases. Workflow disruption occurred in 4/14 cases and ergonomic symptoms (mild dizziness or double vision) were reported in 6/14 cases. Field of view was equivalent between 2D and 3D imaging. No dural injuries, neurological deficits or reoperations occurred. All patients demonstrated recovery consistent with expected postoperative trajectories. Conclusions: This case series demonstrates the potential for 3D endoscopy to be used as an adjunct in endoscopic spine surgery with improvements in depth perception, instrument handling and visualisation of spatial relationships without altering endoscope diameter or access corridors. While an initial familiarisation phase is required, the system demonstrates potential workflow and educational value. Further prospective studies with quantitative metrics and long-term outcomes are warranted.
- Open Access
- 1 December 2025
- Published by AME Publishing Company in Journal of Spine Surgery
- Vol. 11 (4) , 1035-1043
BLEED-LESS: a scoping review on blood loss elimination in endoscopic decompression—lessons and literature on endoscopic spine surgery
Background: Endoscopic spine surgery has emerged as a significant advancement in minimally invasive spinal procedures, with advantages including reduced tissue trauma, faster recovery, and improved patient outcomes. A critical component of these surgeries is effective haemostasis, essential for maintaining visual clarity, ensuring surgical efficiency, and minimising perioperative complications. A scoping review was conducted to examine current clinical practices and research on haemostasis in endoscopic spine surgery, with the aim of synthesising existing knowledge into a practical framework to guide surgeons in managing intraoperative bleeding in endoscopic spine surgery. Methods: A comprehensive literature search was conducted across PubMed, Embase and Cochrane Library, guided by the Population-Concept-Context (PCC) framework. Studies were included if they reported on techniques to achieve haemostasis in endoscopic spine procedures. Data were extracted on study design, surgical technique, haemostatic tools or agents used, and bleeding-related outcomes. Results: The review identified various haemostatic methods including bipolar and radiofrequency cautery, tranexamic acid, gelatin-thrombin matrix sealants, bone wax, irrigation pressure modulation, and absorbable hemostatic agents. The review highlights that no single haemostatic method can be applied to all cases of endoscopic spine surgery. Instead, a multimodal approach is necessary to effectively achieve haemostasis. Based on this synthesis, we propose the FIBRE protocol, encompassing fluid management, initial exposure, bone bleeding control, red-out scenarios, and extra considerations, as a practical framework for managing haemostasis. Conclusions: The proposed FIBRE protocol is a framework for controlling bleeding, improving visualisation, and enhancing surgical outcomes. By integrating these practices, surgeons can refine their techniques and contribute to enhanced patient outcomes in minimally invasive spine surgery.
- 1 December 2025
- Published by AME Publishing Company in Journal of Spine Surgery
- Vol. 11 (4) , 1035-1043
Open AccessBLEED-LESS: a scoping review on blood loss elimination in endoscopic decompression—lessons and literature on endoscopic spine surgery
Background: Endoscopic spine surgery has emerged as a significant advancement in minimally invasive spinal procedures, with advantages including reduced tissue trauma, faster recovery, and improved patient outcomes. A critical component of these surgeries is effective haemostasis, essential for maintaining visual clarity, ensuring surgical efficiency, and minimising perioperative complications. A scoping review was conducted to examine current clinical practices and research on haemostasis in endoscopic spine surgery, with the aim of synthesising existing knowledge into a practical framework to guide surgeons in managing intraoperative bleeding in endoscopic spine surgery. Methods: A comprehensive literature search was conducted across PubMed, Embase and Cochrane Library, guided by the Population-Concept-Context (PCC) framework. Studies were included if they reported on techniques to achieve haemostasis in endoscopic spine procedures. Data were extracted on study design, surgical technique, haemostatic tools or agents used, and bleeding-related outcomes. Results: The review identified various haemostatic methods including bipolar and radiofrequency cautery, tranexamic acid, gelatin-thrombin matrix sealants, bone wax, irrigation pressure modulation, and absorbable hemostatic agents. The review highlights that no single haemostatic method can be applied to all cases of endoscopic spine surgery. Instead, a multimodal approach is necessary to effectively achieve haemostasis. Based on this synthesis, we propose the FIBRE protocol, encompassing fluid management, initial exposure, bone bleeding control, red-out scenarios, and extra considerations, as a practical framework for managing haemostasis. Conclusions: The proposed FIBRE protocol is a framework for controlling bleeding, improving visualisation, and enhancing surgical outcomes. By integrating these practices, surgeons can refine their techniques and contribute to enhanced patient outcomes in minimally invasive spine surgery.
- Open Access
- 1 August 2024
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2024 (8) , rjae540
Three-dimensional endoscopy in lumbar spine surgery as a novel approach for degenerative pathologies: a case report
Endoscopic spine surgery has evolved exponentially. However, the two-dimensional (2D) view results in lack of stereoscopic vision and depth perception, contributing to the steep learning curve. This case report recounts a world first trial of a three-dimensional (3D) endoscopic system that converts 2D to 3D images and explores its potential role in the surgical management of degenerative lumbar spine diseases. The 3D endoscopic system was used for two patient cases and both 2D and 3D images were displayed side by side and compared. Advantages of the 3D endoscopic system include increased perception of depth, rapid identification of bleeding points, and greater visualization of anatomical details. Field of view and exposure were identical in 2D and 3D views. Limitations include costs and need for additional equipment. Overall, 3D endoscopy improved depth perception, instrument manoeuvrability, and recognition of anatomical details. This case report can guide further research and training in endoscopic spine surgery.
- 1 August 2024
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2024 (8) , rjae540
Open AccessThree-dimensional endoscopy in lumbar spine surgery as a novel approach for degenerative pathologies: a case report
Endoscopic spine surgery has evolved exponentially. However, the two-dimensional (2D) view results in lack of stereoscopic vision and depth perception, contributing to the steep learning curve. This case report recounts a world first trial of a three-dimensional (3D) endoscopic system that converts 2D to 3D images and explores its potential role in the surgical management of degenerative lumbar spine diseases. The 3D endoscopic system was used for two patient cases and both 2D and 3D images were displayed side by side and compared. Advantages of the 3D endoscopic system include increased perception of depth, rapid identification of bleeding points, and greater visualization of anatomical details. Field of view and exposure were identical in 2D and 3D views. Limitations include costs and need for additional equipment. Overall, 3D endoscopy improved depth perception, instrument manoeuvrability, and recognition of anatomical details. This case report can guide further research and training in endoscopic spine surgery.
- 22 February 2024
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 32 (4) , 1267-1271
Ophthalmic artery stenosis on three-dimensional rotational angiography: Interrater agreement, prevalence, and risk factors
Background: There is emerging interest in ophthalmic artery (OA) stenosis angioplasty for the treatment of age-related macular degeneration. Three-dimensional rotational angiography (3DRA) could be used during conventional angiography to determine the presence and severity of OA stenosis. In patients who had undergone 3DRA of the internal carotid artery, we aimed to assess the interrater agreement, prevalence, and risk factors for OA stenosis. Methods: Consecutive patients from two centers who had undergone conventional angiography with 3DRA of the internal carotid arteries were enrolled in this study. 3DRAs were independently double read for the presence of OA stenosis, as defined as narrowing of the proximal OA of at least 50% when compared to the more distal “normal” OA. Interrater agreement for the evaluation of OA stenosis was assessed with the Cohen's kappa coefficient. Univariate and multivariable logistic regression were used to identify potential predictors of OA stenosis. Results: Three hundred and two patients (97 men; mean ± SD 57.6 ± 13.4 years) were included in the analysis. Cohen's kappa coefficient (95% CI) was 0.877 (0.798–0.956). OA stenosis was present in 45 patients (14.9%). Multiple logistic regression demonstrated that female sex (odds ratio [OR] = 2.70, 95% confidence interval [CI] 1.18–6.09, p = 0.02) and smoking (OR = 2.11, 95% CI 1.10–4.06, p = 0.03) were significant risk factors for OA stenosis. Age, hypertension, diabetes, coronary artery disease, and subarachnoid hemorrhage were not associated with OA stenosis. Conclusion: The evaluation of OA stenosis on 3DRA had excellent interrater agreement. OA stenosis was common and was associated with smoking and female sex.
- 22 February 2024
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 32 (4) , 1267-1271
Ophthalmic artery stenosis on three-dimensional rotational angiography: Interrater agreement, prevalence, and risk factors
Background: There is emerging interest in ophthalmic artery (OA) stenosis angioplasty for the treatment of age-related macular degeneration. Three-dimensional rotational angiography (3DRA) could be used during conventional angiography to determine the presence and severity of OA stenosis. In patients who had undergone 3DRA of the internal carotid artery, we aimed to assess the interrater agreement, prevalence, and risk factors for OA stenosis. Methods: Consecutive patients from two centers who had undergone conventional angiography with 3DRA of the internal carotid arteries were enrolled in this study. 3DRAs were independently double read for the presence of OA stenosis, as defined as narrowing of the proximal OA of at least 50% when compared to the more distal “normal” OA. Interrater agreement for the evaluation of OA stenosis was assessed with the Cohen's kappa coefficient. Univariate and multivariable logistic regression were used to identify potential predictors of OA stenosis. Results: Three hundred and two patients (97 men; mean ± SD 57.6 ± 13.4 years) were included in the analysis. Cohen's kappa coefficient (95% CI) was 0.877 (0.798–0.956). OA stenosis was present in 45 patients (14.9%). Multiple logistic regression demonstrated that female sex (odds ratio [OR] = 2.70, 95% confidence interval [CI] 1.18–6.09, p = 0.02) and smoking (OR = 2.11, 95% CI 1.10–4.06, p = 0.03) were significant risk factors for OA stenosis. Age, hypertension, diabetes, coronary artery disease, and subarachnoid hemorrhage were not associated with OA stenosis. Conclusion: The evaluation of OA stenosis on 3DRA had excellent interrater agreement. OA stenosis was common and was associated with smoking and female sex.
- Open Access
- 31 December 2023
- Published by The Korean Spinal Neurosurgery Society in Neurospine
- Vol. 20 (4) , 1321-1327
Australian Spine Surgeon’s Perspectives on Endoscopic Spine Surgery: An In-depth Analysis
Objective: Endoscopic spine surgery (ESS) is a minimally invasive approach with reduced tissue trauma, shorter hospital stays, and faster recovery times. It employs advanced endoscopic instruments and imaging technologies to address a wide range of spinal pathologies with minimal disruption to surrounding tissues. As ESS continues to evolve, this article aims to gather insights into the opinions and perspectives of the key stakeholders involved, and highlight strategies to improve implementation.Methods: A cross-sectional survey was distributed to collect data on Australian spine surgeons’ perspectives of ESS. The survey questionnaire was distributed electronically to a diverse group of spine surgeons who are members of the Spine Society of Australia.Results: Of responders, 46.8% were already integrating ESS into practice, or had the sufficient training to commence ESS. A further 29.8% were contemplating introduction of ESS techniques, while just under one quarter of respondents (23.4%) were not interested in implementing minimally invasive techniques. Primary motivators for implementation included skill development and improved patient outcomes. Primary barriers included lack of training opportunities, length of time to develop competency and lack of current supporting evidence.Conclusion: The study contributes to the existing body of knowledge on ESS by providing a comprehensive analysis of surgeon opinions and experiences. The results highlight the growing interest in endoscopic techniques, while recognizing the challenges that need to be addressed to make this more widely utilised and available. The findings can guide future research, training programs, clinical practice and ultimately improve health and financial outcomes to patients and the wider health system.
- 31 December 2023
- Published by The Korean Spinal Neurosurgery Society in Neurospine
- Vol. 20 (4) , 1321-1327
Open AccessAustralian Spine Surgeon’s Perspectives on Endoscopic Spine Surgery: An In-depth Analysis
Objective: Endoscopic spine surgery (ESS) is a minimally invasive approach with reduced tissue trauma, shorter hospital stays, and faster recovery times. It employs advanced endoscopic instruments and imaging technologies to address a wide range of spinal pathologies with minimal disruption to surrounding tissues. As ESS continues to evolve, this article aims to gather insights into the opinions and perspectives of the key stakeholders involved, and highlight strategies to improve implementation.Methods: A cross-sectional survey was distributed to collect data on Australian spine surgeons’ perspectives of ESS. The survey questionnaire was distributed electronically to a diverse group of spine surgeons who are members of the Spine Society of Australia.Results: Of responders, 46.8% were already integrating ESS into practice, or had the sufficient training to commence ESS. A further 29.8% were contemplating introduction of ESS techniques, while just under one quarter of respondents (23.4%) were not interested in implementing minimally invasive techniques. Primary motivators for implementation included skill development and improved patient outcomes. Primary barriers included lack of training opportunities, length of time to develop competency and lack of current supporting evidence.Conclusion: The study contributes to the existing body of knowledge on ESS by providing a comprehensive analysis of surgeon opinions and experiences. The results highlight the growing interest in endoscopic techniques, while recognizing the challenges that need to be addressed to make this more widely utilised and available. The findings can guide future research, training programs, clinical practice and ultimately improve health and financial outcomes to patients and the wider health system.
- 24 June 2023
- Published by Springer Nature in Neurosurgical Review
- Vol. 46 (1) , 1-13
Endovascular and microsurgical management of blister aneurysms: a multi-centre review
Blister aneurysms (BA) are high-risk cerebrovascular lesions accounting for 1% of intracranial aneurysms. The defective vessel wall and broad-based neck make this clinical entity difficult to treat, with high rates of re-rupture and mortality in patients presenting with acute subarachnoid haemorrhage. Blister aneurysms pose substantial challenges for both endovascular and microsurgical management. The objective of this study is to evaluate endovascular and microsurgical outcomes in intracranial blister aneurysm management across two tertiary hospitals. A review of two tertiary hospitals with a systematic imaging database search for term of “blister” in modalities from January 2010 to October 2022 was conducted. Operation reports were screened for the 5-year period since cerebral angiogram reports transitioned to surgical database. Identified reports were screened and reviewed for confirmed diagnosis by consultant neuroradiologist. A total of 21 cases of blister aneurysms managed at respective facilities were included. Sixteen cases (76%) were managed endovascularly. Four cases (19%) were managed surgically—2 with primary clipping, and 2 wrap and clipping. One case was managed conservatively (5%). Clinical outcomes were discharge disposition, aneurysm exclusion and post-operative complications. BAs have challenging considerations with high mortality and morbidity. Endovascular treatment offers a less invasive modality with lower rates of intraoperative rupture and morbidity. Mortality rates and patients discharged home were comparable. Commencement of dual anti-platelet therapy was safe in patients with flow diversion stents despite sub-arachnoid blood volume. Management of blister aneurysms is complex. Endovascular treatment shows promise for acute management but careful collaborative consideration of antithrombotic regime and requirement for further surgery should be considered.
- 24 June 2023
- Published by Springer Nature in Neurosurgical Review
- Vol. 46 (1) , 1-13
Endovascular and microsurgical management of blister aneurysms: a multi-centre review
Blister aneurysms (BA) are high-risk cerebrovascular lesions accounting for 1% of intracranial aneurysms. The defective vessel wall and broad-based neck make this clinical entity difficult to treat, with high rates of re-rupture and mortality in patients presenting with acute subarachnoid haemorrhage. Blister aneurysms pose substantial challenges for both endovascular and microsurgical management. The objective of this study is to evaluate endovascular and microsurgical outcomes in intracranial blister aneurysm management across two tertiary hospitals. A review of two tertiary hospitals with a systematic imaging database search for term of “blister” in modalities from January 2010 to October 2022 was conducted. Operation reports were screened for the 5-year period since cerebral angiogram reports transitioned to surgical database. Identified reports were screened and reviewed for confirmed diagnosis by consultant neuroradiologist. A total of 21 cases of blister aneurysms managed at respective facilities were included. Sixteen cases (76%) were managed endovascularly. Four cases (19%) were managed surgically—2 with primary clipping, and 2 wrap and clipping. One case was managed conservatively (5%). Clinical outcomes were discharge disposition, aneurysm exclusion and post-operative complications. BAs have challenging considerations with high mortality and morbidity. Endovascular treatment offers a less invasive modality with lower rates of intraoperative rupture and morbidity. Mortality rates and patients discharged home were comparable. Commencement of dual anti-platelet therapy was safe in patients with flow diversion stents despite sub-arachnoid blood volume. Management of blister aneurysms is complex. Endovascular treatment shows promise for acute management but careful collaborative consideration of antithrombotic regime and requirement for further surgery should be considered.
- Open Access
- 12 April 2023
- Published by Springer Nature in Research Square
Endovascular and microsurgical management of blister aneurysms: a multi-centre review
Background Blister aneurysms (BA) are high risk cerebrovascular lesions accounting for 1% of intracranial aneurysms. The defective vessel wall and broad-based neck make this clinical entity difficult to treat, with high rates of re-rupture and mortality in patients presenting with acute subarachnoid haemorrhage. Blister aneurysms pose substantial challenges for both endovascular and microsurgical management.Objective To evaluate endovascular and microsurgical outcomes in intracranial blister aneurysm management across two tertiary hospitals.Methods A review of two tertiary hospitals with a systematic imaging database search for term of “blister” in modalities from January 2010 to October 2022. Operation reports were screened for the 5-year period since cerebral angiogram reports transitioned to surgical database. Identified reports were screened and reviewed for confirmed diagnosis by consultant neuroradiologist.Results 21 cases of blister aneurysms managed at respective facilities were included. 16 cases (76%) were managed endovascularly – all with flow diversion stents. 4 cases (19%) were managed surgically – 2 with primary clipping, and 2 wrap and clipping. 1 case was managed conservatively (5%). Clinical outcomes were discharge disposition, aneurysm exclusion and post-operative complications.Conclusion BAs have challenging considerations with high mortality and morbidity. Endovascular treatment is less invasive option with lower rates of intraoperative rupture and mortality. Patients discharged home were comparable. Commencement of dual anti-platelet therapy was safe in patients with flow diversion stents despite sub-arachnoid blood volume. Management of blister aneurysms is complex. Endovascular treatment shows promise for acute treatment but careful consideration of antithrombotic regime and requirement for further surgery should be considered.
- 12 April 2023
- Published by Springer Nature in Research Square
Open AccessEndovascular and microsurgical management of blister aneurysms: a multi-centre review
Background Blister aneurysms (BA) are high risk cerebrovascular lesions accounting for 1% of intracranial aneurysms. The defective vessel wall and broad-based neck make this clinical entity difficult to treat, with high rates of re-rupture and mortality in patients presenting with acute subarachnoid haemorrhage. Blister aneurysms pose substantial challenges for both endovascular and microsurgical management.Objective To evaluate endovascular and microsurgical outcomes in intracranial blister aneurysm management across two tertiary hospitals.Methods A review of two tertiary hospitals with a systematic imaging database search for term of “blister” in modalities from January 2010 to October 2022. Operation reports were screened for the 5-year period since cerebral angiogram reports transitioned to surgical database. Identified reports were screened and reviewed for confirmed diagnosis by consultant neuroradiologist.Results 21 cases of blister aneurysms managed at respective facilities were included. 16 cases (76%) were managed endovascularly – all with flow diversion stents. 4 cases (19%) were managed surgically – 2 with primary clipping, and 2 wrap and clipping. 1 case was managed conservatively (5%). Clinical outcomes were discharge disposition, aneurysm exclusion and post-operative complications.Conclusion BAs have challenging considerations with high mortality and morbidity. Endovascular treatment is less invasive option with lower rates of intraoperative rupture and mortality. Patients discharged home were comparable. Commencement of dual anti-platelet therapy was safe in patients with flow diversion stents despite sub-arachnoid blood volume. Management of blister aneurysms is complex. Endovascular treatment shows promise for acute treatment but careful consideration of antithrombotic regime and requirement for further surgery should be considered.
- 30 November 2022
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 107, 184-191
Clinical gait characteristics in the early post-concussion phase: A systematic review
- 30 November 2022
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 107, 184-191
Clinical gait characteristics in the early post-concussion phase: A systematic review
- 1 February 2022
- Published by Elsevier in World Neurosurgery
- Vol. 158, 114-117
Spinal Subdural Hematoma: Rare Complication of Spinal Decompression Surgery
- 1 February 2022
- Published by Elsevier in World Neurosurgery
- Vol. 158, 114-117
Spinal Subdural Hematoma: Rare Complication of Spinal Decompression Surgery