Alison Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alison Ma has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Ralph Jasper Mobbs
Faculty of Medicine, University of New South Wales (UNSW), Sydney, Australia
7 shared publications - Joseph Reidy
Department of Neurosurgery, Prince of Wales Hospital, Randwick, NSW, Australia
3 shared publications Ralph J. Mobbs
Faculty of Medicine, University of New South Wales, Sydney, NSW 2033, Australia; NeuroSpine Surgery Research Group (NSURG), Randwick, NSW 2031, Australia; NeuroSpine Clinic, Prince of Wales Private Hospital, Randwick, NSW 2031, Australia
3 shared publications- Christopher Huang
Faculty of Medicine, University of New South Wales (UNSW), Sydney, Australia
2 shared publications - Nathan Xie
NeuroSpine Surgery Research Group (NSURG), Randwick, NSW, Australia
2 shared publications Richard Parkinson
Department of Neurosciences, St Vincents Hospital, Darlinghurst, NSW 2010, Australia; School of Medicine, University of Notre Dame, Darlinghurst, NSW 2010, Australia; Faculty of Medicine, University of New South Wales, Sydney, NSW 2033, Australia
2 shared publications
Latest Publications
- Open Access
- 1 June 2026
- Published by AME Publishing Company in Journal of Spine Surgery
- Vol. 12 (6) , 98
Evaluating the advantages and limitations of three-dimensional (3D) endoscopy as an innovative tool in spine surgery for degenerative pathologies: a case series
Background: Endoscopic spine surgery reduces tissue damage, blood loss and postoperative pain. However, the two-dimensional (2D) view prevents depth perception and spatial orientation, contributing to a steep learning curve. Three-dimensional (3D) endoscopes improve depth perception but introduce increased scope diameter, workflow disruption and reduced image quality. A novel algorithm-based 3D visualisation system enables real-time conversion of standard 2D endoscopic images into 3D without requiring a dedicated 3D endoscope. Its impact on surgical workflow and intraoperative performance in spine surgery remains unknown. Case Description: 14 patients with degenerative spinal pathology underwent endoscopic surgery using a real-time 2D-to-3D conversion system (13 uniportal, 1 biportal). Outcomes were assessed across predefined domains: (I) visualisation; (II) instrument handling; (III) haemostasis; (IV) educational impact; (V) workflow; and (VI) ergonomics. Improved visualisation (depth perception and spatial orientation) were observed in all cases. Improved instrument handling (navigation and drill control) was observed in all decompression cases (10/10). Enhanced haemostasis recognition was reported in 6/10 applicable cases. Educational benefit was observed in 6/14 cases. Workflow disruption occurred in 4/14 cases and ergonomic symptoms (mild dizziness or double vision) were reported in 6/14 cases. Field of view was equivalent between 2D and 3D imaging. No dural injuries, neurological deficits or reoperations occurred. All patients demonstrated recovery consistent with expected postoperative trajectories. Conclusions: This case series demonstrates the potential for 3D endoscopy to be used as an adjunct in endoscopic spine surgery with improvements in depth perception, instrument handling and visualisation of spatial relationships without altering endoscope diameter or access corridors. While an initial familiarisation phase is required, the system demonstrates potential workflow and educational value. Further prospective studies with quantitative metrics and long-term outcomes are warranted.
- 1 June 2026
- Published by AME Publishing Company in Journal of Spine Surgery
- Vol. 12 (6) , 98
Open AccessEvaluating the advantages and limitations of three-dimensional (3D) endoscopy as an innovative tool in spine surgery for degenerative pathologies: a case series
Background: Endoscopic spine surgery reduces tissue damage, blood loss and postoperative pain. However, the two-dimensional (2D) view prevents depth perception and spatial orientation, contributing to a steep learning curve. Three-dimensional (3D) endoscopes improve depth perception but introduce increased scope diameter, workflow disruption and reduced image quality. A novel algorithm-based 3D visualisation system enables real-time conversion of standard 2D endoscopic images into 3D without requiring a dedicated 3D endoscope. Its impact on surgical workflow and intraoperative performance in spine surgery remains unknown. Case Description: 14 patients with degenerative spinal pathology underwent endoscopic surgery using a real-time 2D-to-3D conversion system (13 uniportal, 1 biportal). Outcomes were assessed across predefined domains: (I) visualisation; (II) instrument handling; (III) haemostasis; (IV) educational impact; (V) workflow; and (VI) ergonomics. Improved visualisation (depth perception and spatial orientation) were observed in all cases. Improved instrument handling (navigation and drill control) was observed in all decompression cases (10/10). Enhanced haemostasis recognition was reported in 6/10 applicable cases. Educational benefit was observed in 6/14 cases. Workflow disruption occurred in 4/14 cases and ergonomic symptoms (mild dizziness or double vision) were reported in 6/14 cases. Field of view was equivalent between 2D and 3D imaging. No dural injuries, neurological deficits or reoperations occurred. All patients demonstrated recovery consistent with expected postoperative trajectories. Conclusions: This case series demonstrates the potential for 3D endoscopy to be used as an adjunct in endoscopic spine surgery with improvements in depth perception, instrument handling and visualisation of spatial relationships without altering endoscope diameter or access corridors. While an initial familiarisation phase is required, the system demonstrates potential workflow and educational value. Further prospective studies with quantitative metrics and long-term outcomes are warranted.
- Open Access
- 10 April 2026
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 17, 214
Postoperative confusion, pneumocephalus, and seizure following uniportal endoscopic lumbar discectomy: A case report
Background: Postoperative neurological disturbance after endoscopic lumbar discectomy is rare. Proposed mechanisms include dural breach, irrigation-pressure transmission into the cerebrospinal fluid (CSF) space, pneumocephalus, and chemical or inflammatory irritation. As utilization of uniportal systems with continuous irrigation increases, recognizing these interactions is increasingly important. Case Description: A 29-year-old man underwent uniportal endoscopic L5/S1 discectomy for left S1 radiculopathy. No durotomy was identified intraoperatively, and irrigation pressures were maintained between 25 and 40 mmHg. Four hours postoperatively, he developed acute confusion and a generalized tonic-clonic seizure. Computed tomography brain demonstrated intracranial pneumocephalus without hemorrhage, consistent with retrograde air entry through an unrecognized dural defect facilitated by pressure fluctuations and operative gas production. He was managed with supportive care, head elevation, supplemental oxygen, and a single loading dose of levetiracetam, with no further seizures. Cognition normalized within 24 h, and radicular symptoms resolved. Persistent postural headaches prompted re-intervention on day 7, where a small, contained durotomy adjacent to the traversing nerve root was identified and repaired endoscopically, resulting in complete symptom resolution. Conclusion: Although uncommon, acute confusion, seizure, and pneumocephalus may occur following endoscopic lumbar discectomy when dural injury allows pressure transmission or air ingress into the CSF compartment. Prompt neurological assessment, urgent imaging, and short-term monitored care support excellent outcomes. As endoscopic spine surgery continues to expand, understanding the interaction between irrigation dynamics, dural integrity, and intracranial physiology is essential for early recognition and prevention of this complication.
- 10 April 2026
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 17, 214
Open AccessPostoperative confusion, pneumocephalus, and seizure following uniportal endoscopic lumbar discectomy: A case report
Background: Postoperative neurological disturbance after endoscopic lumbar discectomy is rare. Proposed mechanisms include dural breach, irrigation-pressure transmission into the cerebrospinal fluid (CSF) space, pneumocephalus, and chemical or inflammatory irritation. As utilization of uniportal systems with continuous irrigation increases, recognizing these interactions is increasingly important. Case Description: A 29-year-old man underwent uniportal endoscopic L5/S1 discectomy for left S1 radiculopathy. No durotomy was identified intraoperatively, and irrigation pressures were maintained between 25 and 40 mmHg. Four hours postoperatively, he developed acute confusion and a generalized tonic-clonic seizure. Computed tomography brain demonstrated intracranial pneumocephalus without hemorrhage, consistent with retrograde air entry through an unrecognized dural defect facilitated by pressure fluctuations and operative gas production. He was managed with supportive care, head elevation, supplemental oxygen, and a single loading dose of levetiracetam, with no further seizures. Cognition normalized within 24 h, and radicular symptoms resolved. Persistent postural headaches prompted re-intervention on day 7, where a small, contained durotomy adjacent to the traversing nerve root was identified and repaired endoscopically, resulting in complete symptom resolution. Conclusion: Although uncommon, acute confusion, seizure, and pneumocephalus may occur following endoscopic lumbar discectomy when dural injury allows pressure transmission or air ingress into the CSF compartment. Prompt neurological assessment, urgent imaging, and short-term monitored care support excellent outcomes. As endoscopic spine surgery continues to expand, understanding the interaction between irrigation dynamics, dural integrity, and intracranial physiology is essential for early recognition and prevention of this complication.
- Open Access
- 30 January 2026
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 17, 57
Revision strategies following ESP-L lumbar disc arthroplasty complicated by osteolysis and recurrent symptoms
Background: Viscoelastic lumbar total disc replacements (TDRs) can develop periprosthetic osteolysis likely attributable to wear debris and micromotion at the core–endplate interface. Early recognition and revision are essential to avoid prosthesis explantation. Here, we present two patients with cystic osteolysis following Elastic Spine Pad - Lumbar (ESP-L) viscoelastic lumbar disc arthroplasty. Methods: Two patients developed symptomatic cystic osteolysis within 5 years of ESP-L implantation documented utilizing multimodal imaging (i.e., radiographs and computed tomography). Revision surgery in two cases was based on cyst morphology and implant stability. Case 1 had a large posterior osteolytic cavity and underwent posterior cortical bone trajectory (CBT) fusion with autologous bone grafting. Case 2, with a contained lesion adjacent to an otherwise stable implant, was treated with targeted percutaneous cement augmentation. Results: Longitudinal imaging and clinical follow-up showed symptomatic improvement and radiologic stabilization in both patients. In Case 1, the osteolytic cavity fully resolved within 18 postoperative months, whereas Case 2 achieved immediate mechanical reinforcement and sustained pain reduction following cement injection. Conclusion: Cystic osteolysis is a potential complication of viscoelastic lumbar TDRs. These cases demonstrated that posterior CBT fusion or percutaneous cement augmentation could provide effective symptomatic relief and radiologic stabilization, avoiding the need to remove the prosthesis.
- 30 January 2026
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 17, 57
Open AccessRevision strategies following ESP-L lumbar disc arthroplasty complicated by osteolysis and recurrent symptoms
Background: Viscoelastic lumbar total disc replacements (TDRs) can develop periprosthetic osteolysis likely attributable to wear debris and micromotion at the core–endplate interface. Early recognition and revision are essential to avoid prosthesis explantation. Here, we present two patients with cystic osteolysis following Elastic Spine Pad - Lumbar (ESP-L) viscoelastic lumbar disc arthroplasty. Methods: Two patients developed symptomatic cystic osteolysis within 5 years of ESP-L implantation documented utilizing multimodal imaging (i.e., radiographs and computed tomography). Revision surgery in two cases was based on cyst morphology and implant stability. Case 1 had a large posterior osteolytic cavity and underwent posterior cortical bone trajectory (CBT) fusion with autologous bone grafting. Case 2, with a contained lesion adjacent to an otherwise stable implant, was treated with targeted percutaneous cement augmentation. Results: Longitudinal imaging and clinical follow-up showed symptomatic improvement and radiologic stabilization in both patients. In Case 1, the osteolytic cavity fully resolved within 18 postoperative months, whereas Case 2 achieved immediate mechanical reinforcement and sustained pain reduction following cement injection. Conclusion: Cystic osteolysis is a potential complication of viscoelastic lumbar TDRs. These cases demonstrated that posterior CBT fusion or percutaneous cement augmentation could provide effective symptomatic relief and radiologic stabilization, avoiding the need to remove the prosthesis.
- Open Access
- 9 December 2025
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 144, 111804
The role of collagen pathologies and ligamentous laxity in lumbar disc herniation and its recurrence: a systematic review and meta-analysis
- 9 December 2025
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 144, 111804
Open AccessThe role of collagen pathologies and ligamentous laxity in lumbar disc herniation and its recurrence: a systematic review and meta-analysis
- Open Access
- 1 December 2025
- Published by AME Publishing Company in Journal of Spine Surgery
- Vol. 11 (4) , 1035-1043
BLEED-LESS: a scoping review on blood loss elimination in endoscopic decompression—lessons and literature on endoscopic spine surgery
Background: Endoscopic spine surgery has emerged as a significant advancement in minimally invasive spinal procedures, with advantages including reduced tissue trauma, faster recovery, and improved patient outcomes. A critical component of these surgeries is effective haemostasis, essential for maintaining visual clarity, ensuring surgical efficiency, and minimising perioperative complications. A scoping review was conducted to examine current clinical practices and research on haemostasis in endoscopic spine surgery, with the aim of synthesising existing knowledge into a practical framework to guide surgeons in managing intraoperative bleeding in endoscopic spine surgery. Methods: A comprehensive literature search was conducted across PubMed, Embase and Cochrane Library, guided by the Population-Concept-Context (PCC) framework. Studies were included if they reported on techniques to achieve haemostasis in endoscopic spine procedures. Data were extracted on study design, surgical technique, haemostatic tools or agents used, and bleeding-related outcomes. Results: The review identified various haemostatic methods including bipolar and radiofrequency cautery, tranexamic acid, gelatin-thrombin matrix sealants, bone wax, irrigation pressure modulation, and absorbable hemostatic agents. The review highlights that no single haemostatic method can be applied to all cases of endoscopic spine surgery. Instead, a multimodal approach is necessary to effectively achieve haemostasis. Based on this synthesis, we propose the FIBRE protocol, encompassing fluid management, initial exposure, bone bleeding control, red-out scenarios, and extra considerations, as a practical framework for managing haemostasis. Conclusions: The proposed FIBRE protocol is a framework for controlling bleeding, improving visualisation, and enhancing surgical outcomes. By integrating these practices, surgeons can refine their techniques and contribute to enhanced patient outcomes in minimally invasive spine surgery.
- 1 December 2025
- Published by AME Publishing Company in Journal of Spine Surgery
- Vol. 11 (4) , 1035-1043
Open AccessBLEED-LESS: a scoping review on blood loss elimination in endoscopic decompression—lessons and literature on endoscopic spine surgery
Background: Endoscopic spine surgery has emerged as a significant advancement in minimally invasive spinal procedures, with advantages including reduced tissue trauma, faster recovery, and improved patient outcomes. A critical component of these surgeries is effective haemostasis, essential for maintaining visual clarity, ensuring surgical efficiency, and minimising perioperative complications. A scoping review was conducted to examine current clinical practices and research on haemostasis in endoscopic spine surgery, with the aim of synthesising existing knowledge into a practical framework to guide surgeons in managing intraoperative bleeding in endoscopic spine surgery. Methods: A comprehensive literature search was conducted across PubMed, Embase and Cochrane Library, guided by the Population-Concept-Context (PCC) framework. Studies were included if they reported on techniques to achieve haemostasis in endoscopic spine procedures. Data were extracted on study design, surgical technique, haemostatic tools or agents used, and bleeding-related outcomes. Results: The review identified various haemostatic methods including bipolar and radiofrequency cautery, tranexamic acid, gelatin-thrombin matrix sealants, bone wax, irrigation pressure modulation, and absorbable hemostatic agents. The review highlights that no single haemostatic method can be applied to all cases of endoscopic spine surgery. Instead, a multimodal approach is necessary to effectively achieve haemostasis. Based on this synthesis, we propose the FIBRE protocol, encompassing fluid management, initial exposure, bone bleeding control, red-out scenarios, and extra considerations, as a practical framework for managing haemostasis. Conclusions: The proposed FIBRE protocol is a framework for controlling bleeding, improving visualisation, and enhancing surgical outcomes. By integrating these practices, surgeons can refine their techniques and contribute to enhanced patient outcomes in minimally invasive spine surgery.
- Open Access
- 25 August 2025
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 141, 111566
Translaminar contralateral endoscopic foraminotomy for foraminal stenosis and lumbar disc herniation at L5-S1
- 25 August 2025
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 141, 111566
Open AccessTranslaminar contralateral endoscopic foraminotomy for foraminal stenosis and lumbar disc herniation at L5-S1
- Open Access
- 21 August 2025
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 141, 111580
Biportal endoscopic spine surgery for removal of pedicle fixation hardware
- 21 August 2025
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 141, 111580
Open AccessBiportal endoscopic spine surgery for removal of pedicle fixation hardware
- Open Access
- 15 August 2025
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 140, 111551
Uniportal endoscopic facet joint cyst removal at L5-S1
- 15 August 2025
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 140, 111551
Open AccessUniportal endoscopic facet joint cyst removal at L5-S1
- Open Access
- 31 January 2025
- Published by International Journal of Spine Surgery in International Journal of Spine Surgery
- Vol. 19 (1) , 39-48
Patient Recovery Following Uniportal Endoscopic Vs Open Lumbar Spine Surgery: Objective Analysis of Postoperative Mobility and Gait Patterns Using Wearable Sensors
Background There has been a gradual shift from open spine surgery to minimally invasive techniques such as endoscopic spine surgery to reduce approach-related trauma, collateral damage, and complications. While recovery following surgery has been measured using subjective measures including patient-reported outcome measures, the introduction of smart wearable devices now provides both an objective and continuous method of patient assessment. This prospective study compares patient recovery after uniportal endoscopic and open lumbar spine surgery by analyzing mobility and gait metrics captured by a wearable sensor. Methods Participants included 24 patients who underwent a single-level uniportal endoscopic lumbar decompression or open posterior lumbar fusion. During the first 48 hours after surgery, patients wore a sensor that continuously monitored position, step count, and gait metrics. Results In the immediate postoperative period, endoscopic spine surgery patients experienced a quicker return to mobility, with less time lying down, higher step count, faster gait velocity, lower double support percentage, and reduced variability, compared with open spine surgery patients. Conclusion There are key differences in patient mobility and gait following uniportal endoscopic and open spine surgery. Endoscopic spine surgery patients had faster recovery, which can guide resource allocation toward the development of training programs and support the advancement of spine endoscopy to address a broader range of pathologies. This pilot study highlights the potential for wearable devices to be used in further studies to form spine surgery recovery trajectories, allowing targeted rehabilitation and prompt intervention for deviations in patient recovery. Clinical Relevance This study demonstrates the benefits of endoscopic spine surgery for improved postoperative recovery in terms of mobility and gait metrics. Additionally, it highlights the potential for wearable sensor technology to provide an objective and continuous method for assessing postoperative outcomes and for the development of individualized rehabilitation protocols. These findings support the broader adoption of endoscopic techniques and emphasize the value of incorporating wearable devices into postoperative monitoring to optimize patient care. Level of Evidence 3.
- 31 January 2025
- Published by International Journal of Spine Surgery in International Journal of Spine Surgery
- Vol. 19 (1) , 39-48
Open AccessPatient Recovery Following Uniportal Endoscopic Vs Open Lumbar Spine Surgery: Objective Analysis of Postoperative Mobility and Gait Patterns Using Wearable Sensors
Background There has been a gradual shift from open spine surgery to minimally invasive techniques such as endoscopic spine surgery to reduce approach-related trauma, collateral damage, and complications. While recovery following surgery has been measured using subjective measures including patient-reported outcome measures, the introduction of smart wearable devices now provides both an objective and continuous method of patient assessment. This prospective study compares patient recovery after uniportal endoscopic and open lumbar spine surgery by analyzing mobility and gait metrics captured by a wearable sensor. Methods Participants included 24 patients who underwent a single-level uniportal endoscopic lumbar decompression or open posterior lumbar fusion. During the first 48 hours after surgery, patients wore a sensor that continuously monitored position, step count, and gait metrics. Results In the immediate postoperative period, endoscopic spine surgery patients experienced a quicker return to mobility, with less time lying down, higher step count, faster gait velocity, lower double support percentage, and reduced variability, compared with open spine surgery patients. Conclusion There are key differences in patient mobility and gait following uniportal endoscopic and open spine surgery. Endoscopic spine surgery patients had faster recovery, which can guide resource allocation toward the development of training programs and support the advancement of spine endoscopy to address a broader range of pathologies. This pilot study highlights the potential for wearable devices to be used in further studies to form spine surgery recovery trajectories, allowing targeted rehabilitation and prompt intervention for deviations in patient recovery. Clinical Relevance This study demonstrates the benefits of endoscopic spine surgery for improved postoperative recovery in terms of mobility and gait metrics. Additionally, it highlights the potential for wearable sensor technology to provide an objective and continuous method for assessing postoperative outcomes and for the development of individualized rehabilitation protocols. These findings support the broader adoption of endoscopic techniques and emphasize the value of incorporating wearable devices into postoperative monitoring to optimize patient care. Level of Evidence 3.
- Open Access
- 1 August 2024
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2024 (8) , rjae540
Three-dimensional endoscopy in lumbar spine surgery as a novel approach for degenerative pathologies: a case report
Endoscopic spine surgery has evolved exponentially. However, the two-dimensional (2D) view results in lack of stereoscopic vision and depth perception, contributing to the steep learning curve. This case report recounts a world first trial of a three-dimensional (3D) endoscopic system that converts 2D to 3D images and explores its potential role in the surgical management of degenerative lumbar spine diseases. The 3D endoscopic system was used for two patient cases and both 2D and 3D images were displayed side by side and compared. Advantages of the 3D endoscopic system include increased perception of depth, rapid identification of bleeding points, and greater visualization of anatomical details. Field of view and exposure were identical in 2D and 3D views. Limitations include costs and need for additional equipment. Overall, 3D endoscopy improved depth perception, instrument manoeuvrability, and recognition of anatomical details. This case report can guide further research and training in endoscopic spine surgery.
- 1 August 2024
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2024 (8) , rjae540
Open AccessThree-dimensional endoscopy in lumbar spine surgery as a novel approach for degenerative pathologies: a case report
Endoscopic spine surgery has evolved exponentially. However, the two-dimensional (2D) view results in lack of stereoscopic vision and depth perception, contributing to the steep learning curve. This case report recounts a world first trial of a three-dimensional (3D) endoscopic system that converts 2D to 3D images and explores its potential role in the surgical management of degenerative lumbar spine diseases. The 3D endoscopic system was used for two patient cases and both 2D and 3D images were displayed side by side and compared. Advantages of the 3D endoscopic system include increased perception of depth, rapid identification of bleeding points, and greater visualization of anatomical details. Field of view and exposure were identical in 2D and 3D views. Limitations include costs and need for additional equipment. Overall, 3D endoscopy improved depth perception, instrument manoeuvrability, and recognition of anatomical details. This case report can guide further research and training in endoscopic spine surgery.