LPLea Sophia Prott

Lea Sophia Prott

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lea Sophia Prott has a total of 47 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Conventional, Milled, and 3D ‐Printed Complete Dentures: A Systematic Review and Meta‐Analysis of Clinical and Patient‐Centered Outcomes

    by L. S. Prott, T. Poklepović Peričić, C. D'ALessandro, M. Rivera, L. Graham, P. C. Gierthmuehlen, R. D. Paravina, A. Carrasco‐Labra, M. B. Blatz

    Objective: To compare conventional, milled, and 3D‐printed complete dentures for clinical performance, patient‐reported outcomes, and cost and time effectiveness across all comparisons. Materials and Methods: MEDLINE, Embase, Scopus, Web of Science, and CENTRAL were searched from inception to May 20, 2026, with no language or duration restrictions. Eligible randomized controlled trials enrolled edentulous adults receiving conventional, milled, or 3D‐printed complete dentures (crossover and parallel‐group designs). Primary outcomes were oral health‐related quality of life, patient satisfaction, and complications. Secondary outcomes included denture retention, base adaptation, masticatory function, bite force, esthetics, biocompatibility/microbial count, patient preference, and cost and time. Data were pooled in random‐effects meta‐analyses. Certainty of evidence was assessed using GRADE. Results: Twenty‐five trials (27 publications) were included. No fabrication method demonstrated a clear advantage with respect to patient‐important outcomes. The only statistically significant pooled difference was a small retention advantage of 3D‐printed over milled dentures (mean difference −1.80 N, low certainty), with the remaining significant findings confined to single trials (very low certainty). 3D‐printed dentures were associated with more mechanical complications and aftercare needs, whereas milled dentures were associated with better patient‐rated esthetics and shorter processing time. Conclusions: Across all comparisons, no fabrication method showed a clear advantage for patient‐important outcomes, and the certainty of evidence was mostly very low. Clinical Significance: As no method has shown clinical superiority, the choice between conventional, milled, and 3D‐printed dentures can be guided by workflow, cost, material durability, and patient factors.

  • Top Cited Papers
    Open Access

    Fatigue performance and failure load of minimally-invasive occlusal veneers made of lithium disilicate and composition-gradient multilayered zirconia: An in vitro study

    by Lea S. Prott, Monique Harlaß, Alexander Marksteiner, Frank A. Spitznagel, Robert Langner, Yu Zhang, Markus B. Blatz, Petra C. Gierthmuehlen

    Purpose: To investigate the effect of ceramic material (lithium disilicate, LDS vs. composition-gradient multilayered zirconia [4Y-PSZ and 5-PSZ], Z) and ceramic layer thickness (0.5 mm, 1.0 mm, and 1.5 mm) on fatigue performance and failure load of occlusal veneers on molars.Methods: Seventy-two CAD-CAM-fabricated occlusal veneer restorations (IPS e.max CAD; IPS e.max ZirCAD Prime Esthetic, Ivoclar Vivadent) were divided into six groups (n=12, LDS-1.5, LDS-1.0, LDS-0.5; Z-1.5, Z-1.0, Z-0.5). Restorations were adhesively cemented (Variolink Esthetic DC, Ivoclar Vivadent) to dentin-analogue composite dies (Z100, 3M ESPE) and exposed to thermomechanical fatigue (1.2 million cycles, 49 N, 1.6 Hz, 5-55° C). Single-load-to-failure was tested with a universal testing machine. Data were analyzed using ANOVA with Tukey post-hoc tests and t-tests (P < 0.05).Results: The overall success rate across all materials and layer thicknesses was 91.7%. Half of the specimens of group Z-0.5 revealed cracks after chewing simulation. Occlusal veneers fabricated from LDS withstood significantly higher failure loads than gradient multilayered zirconia veneers in all tested thicknesses. The mean failure load values led to the following ranking: 3194 N (LDS-0.5)>2683 N (LDS-1.0)>2338 N (LDS-1.5)>1744 N (Z-1.5)>1310 N (Z-0.5)>1198 N (Z-1.0).Conclusions: Ultrathin LDS occlusal veneers outperformed thin and standard thick counterparts, as well as gradient multilayered zirconia veneers at all thickness levels. Ultrathin gradient multilayered zirconia occlusal veneers were prone to cracks during thermomechanical fatigue. Individual mechanical properties need to be considered when aligning the restoration within the multilayered zirconia blank.


  • Open Access

    Fatigue Performance and Failure Loads of Composition‐Gradient Multilayer Zirconia: Partial‐Coverage Restorations Versus Single Crowns at Different Thicknesses

    by F. A. Spitznagel, A. Marksteiner, L. S. Prott, Y. Zhang, M. B. Blatz, L. M. M. Alves, T. M. B. Campos, P. C. Gierthmuehlen

    Objective: This study investigated the influence of restoration type (partial‐coverage versus crown) and ceramic‐layer thickness on the fatigue behavior and failure load of monolithic composition‐gradient multilayer zirconia (4Y‐PSZ/5Y‐PSZ) molar restorations. Material and Methods: Seventy‐two CAD/CAM‐fabricated monolithic zirconia restorations (IPS e.max ZirCAD‐Prime‐Esthetic, Ivoclar‐Vivadent) were assigned to six groups ( n = 12), based on restoration type—partial‐coverage restoration (PCR) or crown (C)—and ceramic thickness (occlusal/buccal: 0.5/0.4, 1.0/0.6, or 1.5/0.8 mm). All restorations were adhesively bonded to standardized dentin‐analogue dies. Specimens underwent thermomechanical fatigue (1.2 million cycles, 49 N, 1.6 Hz, 5°C–55°C), followed by single load to failure testing. Data were analyzed using ANOVA, Tukey's post hoc test, and independent t‐tests (α = 0.05). Results: All specimens survived fatigue. Evident cracks were observed post‐fatigue; one each in PCR‐0.5 and C‐0.5 groups, resulting in an overall success rate of 97.22%. Mean failure loads (N) were: PCR‐0.5: 2047, PCR‐1.0: 2018, PCR‐1.5: 2777, C‐0.5: 695, C‐1.0: 1957, C‐1.5: 3503. Ultrathin (0.5 mm) PCRs demonstrated significantly higher failure loads than ultrathin crowns ( p < 0.001), whereas crowns at 1.5 mm thickness outperformed PCRs ( p = 0.005). No significant difference was observed at 1.0 mm thickness ( p = 0.634). Conclusion: At ultrathin thicknesses (0.5 mm), partial‐coverage designs showed superior failure loads over crowns. Both restoration types are mechanically viable at 1.0 mm and 1.5 mm thicknesses. Clinical Significance: Composition‐gradient multilayer‐zirconia demonstrates high fatigue resistance and is well‐suited for minimally invasive, non‐retentive PCR molar restorations. However, a minimum thickness of 1.0 mm should be maintained for single crowns.


  • Open Access

    Failure Prediction of Lithium Disilicate and Composition-Gradient Multilayered Zirconia Occlusal Veneers: A Fractographic and Theoretical Analysis

    by Lea S. Prott, Petra C. Gierthmuehlen, Markus B. Blatz, Yu Zhang

    This in vitro study aimed to evaluate the fatigue behavior of occlusal veneers (OVs) made of lithium disilicate and composition-gradient multilayered zirconia at different thicknesses, incorporating both experimental and theoretical analyses to predict long-term performance. Seventy-two OVs with ceramic layer thicknesses of 0.5 mm, 1.0 mm, and 1.5 mm were fabricated and adhesively bonded to dentin analog composite abutments. All specimens underwent thermomechanical fatigue testing, involving cyclic loading (49 N, 1.6 Hz, 1.2 million cycles) and thermocycling (5–55 °C), simulating five years of clinical function. Fracture patterns were analyzed using light microscopy and scanning electron microscopy. A fatigue lifetime model based on plate-on-foundation theory and slow crack growth was applied to estimate cycles to radial failure. No complete fractures or debonding occurred. However, 50% of 0.5 mm zirconia OVs developed flexural radial cracks from the intaglio surface, while all lithium disilicate and zirconia veneers ≥1.0 mm remained intact. Theoretical predictions closely matched the experimental outcomes, indicating that 0.5 mm zirconia performance aligned with the lower-bound fatigue estimates for 5Y-PSZ. Results suggest that lithium disilicate offers superior fatigue resistance at minimal thickness, while thin zirconia is prone to subsurface cracking. A minimum thickness of 0.7 mm is recommended for zirconia-based OVs.


  • Open Access

    Optimizing Hard and Soft‐Tissue Esthetics With Anterior Cantilever Zirconia Ceramic Resin‐Bonded Fixed Dental Prostheses

    by Markus B. Blatz, Tony Rotondo, Szabi Hant, Lea S. Prott

    Objective: The replacement of missing maxillary lateral incisors poses both functional and esthetic challenges, not only from a restorative but also from a periodontal aspect. This case report presents a step‐by‐step protocol for ideal hard and soft‐tissue esthetics with cantilever zirconia ceramic resin‐bonded fixed dental prostheses (RBFDPs). Clinical Considerations: A 20‐year‐old female patient presented with congenitally missing maxillary lateral incisors, seeking treatment to enhance the esthetics of her smile. Due to the age and ongoing skeletal development, implant placement was deferred. Treatment involved the extraction of a retained deciduous tooth, soft tissue augmentation with a subepithelial connective tissue graft, and the placement of zirconia ceramic single‐retainer RBFDPs. The pontic design and tissue contouring were carefully managed with a removable partial denture to achieve a natural emergence profile and long‐term stability. Conclusion: The combination of RBFDPs and soft tissue augmentation offers a highly esthetic and minimally invasive treatment alternative for replacing missing anterior teeth. Proper case selection, bonding technique, and soft tissue management are critical for long‐term success. Clinical Significance: This report highlights the clinical efficacy of zirconia RBFDPs as a conservative alternative to implants in young patients and demonstrates the importance of soft tissue management for optimal esthetic integration.


  • Open Access

    Transcutaneous Auricular Vagus Nerve Stimulation for the Treatment of Myoarthropathic Symptoms Associated With Temporomandibular Disorders—A Pilot Randomised Controlled Trial

    by Lea S. Prott, Vanessa Kaldenhoven, Alfons Hugger, Robert Langner, Petra C. Gierthmuehlen, Mortimer Gierthmuehlen

    Background: Transcutaneous auricular vagus nerve stimulation (taVNS) is a safe and feasible treatment for a variety of acute and chronic pain conditions. However, no evidence about taVNS effectiveness in patients with chronic pain associated with temporomandibular disorders (TMD) is available. Objective: To evaluate the feasibility of and compliance with taVNS in participants experiencing chronic TMD pain and potential effects on pain, psychological well‐being, muscle activity, and kinematics. Methods: Twenty adults with chronic TMD pain were randomised to receive taVNS ( n = 10) or sham ( n = 10). In the taVNS group, stimulation was performed on the left tragus for 4 h daily (25 Hz, pulse width 250 μs, 28 s on/32 s off). In the sham group, an inactive non‐functional sham electrode was used. Patient‐reported outcome measures (GCPS, PHQ‐9, GAD‐7, PHQ‐15, and OHIP‐G14), muscle activity, and kinematics were assessed at baseline, 4 weeks, and 8 weeks. Compliance was assessed using a smartphone app, which recorded daily stimulation time and intensity. Results: Recruitment and retention rates were high (100% and 90%, respectively), with 83% adherence to the intervention. Participants receiving taVNS showed a large effect on oral health‐related quality of life, and at least a small but potentially important effect on pain intensity, anxiety, depression, severity of somatic symptoms, muscle activity, and kinematics. However, none of these differences were statistically significant. No serious adverse events were identified. Conclusion: taVNS proved feasible in participants with chronic TMD pain, suggesting potential benefits for symptom management. Future studies with larger sample sizes and extended follow‐up durations are necessary to confirm efficacy and safety.


  • Open Access

    In vitro comparison between complete arch abutment-level implant impressions with photogrammetry, grammetry, and intraoral scanning

    by Lea S. Prott, Pablo J. Atria, Caroline V. Maluf, Markus B. Blatz, Julian Conejo


  • Open Access

    Survival of Partial Coverage Restorations on Posterior Teeth—A Scoping Review

    by L. S. Prott, P. Klein, F. A. Spitznagel, M. B. Blatz, S. Pieralli, P. C. Gierthmuehlen

    Objective: To investigate the nature and availability of evidence on the clinical performance of posterior partial coverage restorations (PCR) fabricated from different ceramic materials, outcome definitions, measurement methods, study drop‐outs and follow ups.Overview: A systematic literature search (inception‐February 2024) was performed through MEDLINE, Scopus, CENTRAL, ClinicalTrials.gov, and the International Clinical Trials Registry Platform to identify clinical studies with a focus on posterior PCRs (onlays, occlusal veneers and partial crowns) with a minimum follow‐up of 1 year. Thirteen of 31 included studies were randomized controlled trials (RCT) and 18 non‐randomized studies of intervention (NRS). Six RCTs compared two different ceramic materials and might be suitable for meta‐analysis. Differences in study design, definition of survival, evaluation methods, and statistical models for survival analysis were identified as reasons for expected heterogeneity among studies. The most common reasons for restoration failures were ceramic fractures and retention loss.Conclusion: The evidence informing the effect of PCRs varied in definitions of survival and failure, complication classifications, and workflow approaches. RCTs addressing clinical performance of PCRs comparing different ceramic materials are available for conducting systematic reviews and meta‐analyses.


  • Open Access

    Survival and Complications of Partial Coverage Restorations on Posterior Teeth—A Systematic Review and Meta‐Analysis

    by L. S. Prott, S. Pieralli, P. Klein, F. A. Spitznagel, F. Ibrahim, M.‐I. Metzendorf, A. Carrasco‐Labra, M. B. Blatz, P. C. Gierthmuehlen

    Objective: To determine the clinical performance of partial coverage restorations (PCR) (onlays, occlusal veneers, and partial crowns) composed of different ceramic and ceramic‐based materials to treat extended posterior defects.Materials and Methods: MEDLINE, Scopus, CENTRAL, ClinicalTrials.gov, and the International Clinical Trials Registry Platform were searched (inception‐February 2024) for randomized controlled trials (RCT) comparing posterior PCRs composed of different ceramic and ceramic‐based materials with a minimum follow‐up of 1 year.Results: Six RCTs were included. Resin matrix ceramic (RMC) and lithium disilicate (LDS) restorations had a 3‐year survival rate of 89.3% (95% CI 76.4–95.3) and 93.7% (95% CI 83.7–97.7), respectively, and leucite‐reinforced glass ceramic (LRGC) restorations a range between 96.1% (95% CI 90.1–98.9) compared with RMC and 98.3% (95% CI 90.8–100) compared with LDS. After 1–3 years of follow‐up, LDS slightly outperformed RMC on restoration failure and loss of retention (1.56 more failures and 1.78 more loss of retentions for RMC per 100 restoration‐years [low certainty evidence]). No statistically significant differences between ceramic and ceramic‐based materials were detected in short‐term follow‐up (1–3 years of follow‐up). The long‐term performance of posterior PCRs is uncertain.Conclusion: The survival of LDS restorations may slightly outperform RMC restorations after 3 years of follow‐up across outcomes, except for bulk fracture. RCTs providing medium to long‐term data are needed.Clinical Significance: Ceramic and ceramic‐based PCRs are a reliable treatment option to restore extended posterior defects.


  • Open Access

    How to Conduct and Publish Systematic Reviews and Meta‐Analyses in Dentistry

    by L. S. Prott, A. Carrasco‐Labra, P. C. Gierthmuehlen, M. B. Blatz

    Objective: To provide a guide for conducting systematic reviews and meta‐analyses in dentistry, with emphasis on translating research findings into clinical practice. Overview: Systematic reviews are essential tools for synthesizing research findings and translating evidence into clinical practice. These reviews help to identify the most effective treatment options and to determine areas requiring further research. A structured approach, including defining a concise research question, conducting comprehensive literature searches, and assessing the risk of bias, is critical for ensuring the review's trustworthiness. The GRADE approach facilitates the assessment of the certainty of evidence, which is crucial for formulating conclusions and making informed clinical decisions. Conclusion: Systematic reviews provide invaluable insights into clinical decision‐making by compiling, analyzing, and synthesizing multiple primary studies. Following a rigorous methodology ensures that systematic reviews are comprehensive, unbiased, and clinically relevant, ultimately contributing to better patient care and achieving better clinical outcomes. Clinical Significance: Methodologically sound systematic reviews and meta‐analyses provide clinicians with high‐quality, synthesized evidence, enabling informed clinical decisions and improved patient outcomes. They save time by consolidating research, informing treatment choices, and facilitating the translation of knowledge into clinical practice.