Kunihiko Nabeshima
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kunihiko Nabeshima has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Naohiro Nakamura
Research and Development Institute, Takenaka Corporation, 1-5-1, Ohtsuka, Inzai, Chiba 270-1395, Japan
2 shared publications - Akira Ota
Engineer at Nuclear Facilities Division Taisei Corporation Shinjuku‐ku Japan
1 shared publication Erdinc Turkcan
Delft University of Technology , Mekelweg 15, 2629 , JB Delft , THE NETHERLANDS
1 shared publicationKatsuo Suzuki
Japan Atomic Energy Research Institute , Tokai-mura , Naka-gun , Ibaraki-ken , 319-1106
1 shared publication- Takuya Suzuki
R&D Institute, Takenaka Corporation Inzai City Japan
1 shared publication Takuya Uesaka
Civil Engineering and Construction Department Takahama Power Station Kansai Electric Power Co. INC. Takahama Oi Fukui Japan
1 shared publication
Latest Publications
- Open Access
- 20 June 2023
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 52 (12) , 3746-3764
Performance of inherent damping models in inelastic seismic analysis for tall building subject to simultaneous horizontal and vertical seismic motion
In recent seismic analyses, it is considered that the structural damping ratio should be treated as independent of frequency, for safety side estimation. Therefore, frequency‐insensitive damping is required for realistic seismic simulations. This paper investigates the performance of various sparse matrix damping models (extended Raleigh, capped viscous and uniform damping) in the inelastic seismic analysis of a 35‐story moment‐frame steel building. These sparse matrix damping models were compared with Rayleigh, tangent Rayleigh, and Wilson‐Penzien (modal) damping models to provide insight into damping models suitable for large‐scale inelastic response history analysis (RHA). First, the necessity of frequency‐insensitive damping in large‐scale analysis is illustrated via numerical simulations. Then, the vibration characteristics with simultaneous inputs of horizontal and vertical ground motion are analyzed using the abovementioned damping schemes, and their results are compared. The comparisons are analyzed by focusing on horizontal displacement/acceleration, story drift angle, beam‐end ductility factor, the amplitude due to beam vibration, and the associated vertical acceleration. Finally, the computation speeds are compared. As a result, it is shown that although these sparse matrix damping models are practically useful, they are not yet sufficient and present challenges.
- 20 June 2023
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 52 (12) , 3746-3764
Open AccessPerformance of inherent damping models in inelastic seismic analysis for tall building subject to simultaneous horizontal and vertical seismic motion
In recent seismic analyses, it is considered that the structural damping ratio should be treated as independent of frequency, for safety side estimation. Therefore, frequency‐insensitive damping is required for realistic seismic simulations. This paper investigates the performance of various sparse matrix damping models (extended Raleigh, capped viscous and uniform damping) in the inelastic seismic analysis of a 35‐story moment‐frame steel building. These sparse matrix damping models were compared with Rayleigh, tangent Rayleigh, and Wilson‐Penzien (modal) damping models to provide insight into damping models suitable for large‐scale inelastic response history analysis (RHA). First, the necessity of frequency‐insensitive damping in large‐scale analysis is illustrated via numerical simulations. Then, the vibration characteristics with simultaneous inputs of horizontal and vertical ground motion are analyzed using the abovementioned damping schemes, and their results are compared. The comparisons are analyzed by focusing on horizontal displacement/acceleration, story drift angle, beam‐end ductility factor, the amplitude due to beam vibration, and the associated vertical acceleration. Finally, the computation speeds are compared. As a result, it is shown that although these sparse matrix damping models are practically useful, they are not yet sufficient and present challenges.
- Open Access
- 25 May 2023
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 52 (12) , 3533-3550
Damage detection based on stiffness identification in time domain for poly‐linear hysteresis using sparse modeling
The physical parameter identification of the dynamic mechanical model, such as stiffness identification, provides some valuable information for detecting post‐earthquake damage to building structures. During an earthquake, tracking changes in stiffness on the skeleton curve can be effective. It would also be helpful as an approximate evaluation if the method could be applied to structures with arbitrary poly‐linear hysteresis characteristics. However, previous research has not identified any poly‐linear hysteresis characteristics in a unified formulation. This paper proposes a new stiffness identification method in the time domain for building structures with any poly‐linear hysteresis characteristics using sparse modeling. The validity of the proposed method was investigated through numerical simulations and a full‐scale shaking table test.
- 25 May 2023
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 52 (12) , 3533-3550
Open AccessDamage detection based on stiffness identification in time domain for poly‐linear hysteresis using sparse modeling
The physical parameter identification of the dynamic mechanical model, such as stiffness identification, provides some valuable information for detecting post‐earthquake damage to building structures. During an earthquake, tracking changes in stiffness on the skeleton curve can be effective. It would also be helpful as an approximate evaluation if the method could be applied to structures with arbitrary poly‐linear hysteresis characteristics. However, previous research has not identified any poly‐linear hysteresis characteristics in a unified formulation. This paper proposes a new stiffness identification method in the time domain for building structures with any poly‐linear hysteresis characteristics using sparse modeling. The validity of the proposed method was investigated through numerical simulations and a full‐scale shaking table test.
- Open Access
- 1 November 2021
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 51 (1) , 153-168
Physical parameters identification for full‐scale ten‐story reinforced concrete building with degrading tri‐linear model by modal iterative error correction method
- 1 November 2021
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 51 (1) , 153-168
Open AccessPhysical parameters identification for full‐scale ten‐story reinforced concrete building with degrading tri‐linear model by modal iterative error correction method
- 1 January 1998
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 35 (2) , 93-100
Real-time Nuclear Power Plant Monitoring with Neural Network.
This paper addresses how to utilize artificial neural networks (ANNs) for detecting anomalies of nuclear power plants in operation. The basic principle of this methodology is to detect the anomaly with deviation between process signals measured from the actual plant and the corresponding output signals from the plant model, which is developed using three-layered auto-associative ANN; the auto-associativity has the advantage of detecting unknown plant conditions. A new learning technique adopted here compensates for the drawback of the conventional back-propagation algorithm, and is presented to make plant dynamic models on the ANN. The test results showed that this plant monitoring system is successful in detecting the symptoms of small anomalies in real-time over the wide power range including start-up, shut-down and steady state operations.
- 1 January 1998
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 35 (2) , 93-100
Real-time Nuclear Power Plant Monitoring with Neural Network.
This paper addresses how to utilize artificial neural networks (ANNs) for detecting anomalies of nuclear power plants in operation. The basic principle of this methodology is to detect the anomaly with deviation between process signals measured from the actual plant and the corresponding output signals from the plant model, which is developed using three-layered auto-associative ANN; the auto-associativity has the advantage of detecting unknown plant conditions. A new learning technique adopted here compensates for the drawback of the conventional back-propagation algorithm, and is presented to make plant dynamic models on the ANN. The test results showed that this plant monitoring system is successful in detecting the symptoms of small anomalies in real-time over the wide power range including start-up, shut-down and steady state operations.