SSSanjeev Kumar Sharma

Sanjeev Kumar Sharma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sanjeev Kumar Sharma has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Calorimetric measurement of ion beam current density profiles in pulsed operations of the SST-1 neutral beam injector

    by Ayush Bhatt, S.K. Sharma, B. Sridhar, K. Qureshi, B. Choksi, S. Parmar, N. Contractor, P. Kumari, P.B. Hansapura, S. Karmakar, et al.

  • Open Access

    Calorimetric Measurement of Ion Beam Current Density Profiles in Pulsed Operations of a Neutral Beam Injector

    by Ayush Bhatt, Sanjeev Kumar Sharma, B Sridhar, K Qureshi, B Choksi, S Parmar, N Contractor, P Kumari, P. B. Hansapura, S Karmakar, et al.

    An actively cooled calorimeter comprising an array of copper blocks was developed and validated for two-dimensional power-density measurements of neutral beams in the SST-1 Neutral Beam Injector. The diagnostic comprises a 5 × 11 array of ETP copper blocks mounted on a composite thermal interface and an actively cooled base plate, enabling accurate calorimetry under high heat fluxes while maintaining safe operating temperatures. The thermal response was investigated using analytical modeling, three-dimensional finite-element analysis, and CFD-based thermal–hydraulic optimization, and subsequently calibrated against experimental cooling data to account for thermal contact resistance. The calorimeter was deployed in-vessel and tested under hydrogen beam operation at energies of 20–35 keV, currents of 20–25 A, and pulse durations of 0.25–1.0 s, corresponding to beam powers up to ∼ 500 kW. The diagnostic enabled reliable reconstruction of the two-dimensional beam power-density profile, quantitative estimation of beam power, and extraction of beam divergence through comparison with a bi-Gaussian model. The measured perveance–divergence characteristics exhibited the expected U-shaped dependence, allowing identification of the perveance-matched operating condition of the ion source. These results demonstrate that the developed calorimeter provides a robust and accurate diagnostic for short-pulse neutral-beam characterization and beamline optimization in high-power NBI syste

  • Experimental Studies on the Roles of Space Charge Neutralization in a Ring Cusp Ion Source

    by Bharat Singh Rawat, S. K. Sharma, V. Prahlad, B. Choksi, U. K. Baruah

    Experimental studies in a ring cusp ion source are performed for investigating the role of space charge neutralization by measuring ion beam profiles, fluxes of charge exchange ions, and distribution of ion beam neutralizing electrons. The measurements are carried out using the argon ion beam of current 30–60 mA and beam energy 1200 eV. A Faraday cup array (FCA) equipped with filtering electrodes is developed and utilized for measuring the ion beam profiles by filtering out the neutralizing electrons and slow-moving charge exchange ions from the ion beam. The radial flux of charge exchange ions is measured using a flat Faraday probe mounted at a location outside the ion beam. The flat Faraday probe is shielded from the energetic beam ions. The flux of charge exchange ions is studied to assess the effect of space charge neutralization inside the ion beam. The reduction in floating potential observed with improved space charge neutralization is found to correlate with a reduced radial flow of charge exchange ions. The FCA is also utilized to measure the distribution profile of neutralizing electrons in the ion beam by biasing its filtering electrodes and Faraday cups (FCs) at appropriate potentials. The radial profiles of neutralizing electrons are found Gaussian as similar to that of the beam ions. It is suggested that the neutralizing electrons are dispersed as similar to the fast ion distribution in order to accomplish an evenly distributed space charge neutralization.


  • Open Access

    Measurement system for ion beam profiles using fixed parallel wires and Faraday cup array

    by Bharat Singh Rawat, S. K Sharma, B. Choksi, V. Prahlad, U. K. Baruah

    The radial profiles of ion current density are measured using a combination of two techniques—fixed parallel wires and a Faraday cup array—in a ring cusp ion source. These measurements are carried out for Ar+ ion beam current in the range of 20–90 mA and energy in the range of 850–1650 eV. Current density profiles near the extraction plane of the ion source are obtained by Abel inversion of the profiles of current measured using the parallel wires. In addition, the Faraday cup array provides radial profiles of ion current density at two different locations along the beam axis. A numerical model is developed and utilized for estimating the beam divergence and focal length from the profiles of ion current density measured using the two techniques. A fixed parallel wire array is established as an effective method for monitoring the ion beam profiles close to the ion source's extraction plane when the ion beam is utilized for other applications. The performance of the two measurement techniques is compared by estimating the ion beam current from the measurement of ion current density with the beam current measured from the power supply.


  • Characterization of a Multicusp Ion Source With Two-Grid Extraction System for Studying Extraction and Transport of Ion Beam

    by Bharat Singh Rawat, S. K. Sharma, B. Choksi, P. Bharathi, B. Sridhar, L. N. Gupta, D. Thakkar, S. L. Parmar, V. Prahlad, U. K. Baruah

    A low-energy multipole line cusp ion source with two-grid extraction system has been developed and characterized for studying the role of the charge exchange processes on ion beam extraction, transport, and neutralization. The ion source is operated for extraction of Ar⁺ ion beam of current 50-240 mA at energies 850-1650 eV. The characterization of the ion beam is carried out at various axial positions along a 200-815-mm beam path with a background pressure of 4-20 x 10⁻⁵ Torr. An 11-channel Faraday cup array is used to measure the radial profiles of ion current density and angular beam divergence at these positions. The beam divergences are found to be in the range of 6°-15° for beam perveance of 0.50-3.75 x 10⁻⁹ AV $^{-3/2}$ . The attenuation of ion beam current along the beam path is observed due to the charge exchange neutralization of the energetic ions in the presence of high background pressure. Since ion current density along the beam path can be reduced by both the charge exchange processes and beam divergence, the accounting of beam particles, i.e., energetic ions and neutrals, at larger distances is difficult by the measurements of ion current density using the Faraday cup alone. The flux of energetic particles (energetic ions and fast neutrals) is therefore obtained by a thrust measurements on a beam target fixed at a distance of 800 mm from the ion source. The neutralization of the ion beam obtained by the emission of electrons from a hot filament neutralizer is also investigated in the presence of the charge exchange processes. Space-charge neutralization is provided initially by the secondary electrons emitted from the vessel walls or by the charge exchange processes even without the neutralizer operating at the desired temperature. However, the current neutralization is achieved only by the electrons emitted from the hot filament neutralizer operating in a space-charge-limited mode.


  • Open Access

    Design of a Prototype Positive Ion Source with Slit Aperture Type Extraction System

    by Sanjeev K Sharma, Prahlad Vattilli, Bhargav Choksi, Bharathi Punyapu, Rambabu Sidibomma, Sridhar Bonagiri, Deepak Aggrawal, Ujjwal K Baruah


  • Characteristics of the positive ion source at reduced gas feed

    by S. K. Sharma, P. Bharathi, V. Prahlad, P. J. Patel, B. Choksi, M. R. Jana, L. K. Bansal, K. Qureshi, C. B. Sumod, V. Vadher, et al.

    The neutral beam injector of steady state superconducting tokamak (SST1-NBI) at IPR is designed for injecting upto 1.7 MW of neutral beam (Hº, 30–55 keV) power to the tokamak plasma for heating and current drive. Operations of the positive ion source (PINI or Plug-In-Neutral-Injector) of SST1-NBI were carried out on the NBI test stand. The PINI was operated at reduced gas feed rate of 2–3 Torr l/s, without using the high speed cryo pumps. Experiments were conducted to achieve a stable beam extraction by optimizing operational parameters namely, the arc current (120–300 A), acceleration voltage (16–40 kV), and a suitable control sequence. The beam divergence, power density profiles, and species fractions (H+:H2+:H3+) were measured by using the diagnostics such as thermal calorimetry, infrared thermography, and Doppler shift spectroscopy. The maximum extracted beam current was about 18 A. A further increase of beam current was found to be limited by the amount of gas feed rate to the ion source.