Edvard Liljedahl Sandberg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Edvard Liljedahl Sandberg has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Jarle Jortveit
Department of Cardiology, Sørlandet Hospital Arendal, Arendal, Norway
7 shared publications - Sigrun Halvorsen
Department of Cardiology, Oslo University Hospital Ullevaal , Oslo
6 shared publications - Bjørnar Grenne
Clinic of Cardiology, St. Olav's University Hospital, Trondheim, Norway; Department of Circulation and Medical Imaging, NTNU - Norwegian University of Science and Technology, Trondheim, Norway
4 shared publications - Dan Atar
Institute of Clinical Medicine, University of Oslo, Oslo, Norway
4 shared publications - Trygve Berge
Bærum Hospital, Vestre Viken Hospital Trust
4 shared publications - Jostein Grimsmo
Department of Cardiac Rehabilitation, Lovisenberg Rehabilitation, Cathinka Guldbergs Hospital , Jessheim
3 shared publications
Latest Publications
- Open Access
- 1 January 2025
- Published by S. Karger AG in Biomedicine Hub
- Vol. 10 (1) , 191-196
Atrial Fibrillation in 63-Year-Old Former Elite Endurance Athletes: A 38-Year Follow-Up Study
Introduction: There are many reports on atrial fibrillation/flutter (AF) in previous elite endurance athletes (ExA) and veteran athletes (VA), but no prospective studies on AF in elite endurance athletes (EA) have been published. Most studies are on males and increased risk in males has been found, but the explanation of this has been controversial. Methods: We present a study where 15 male and 15 female EA and matched groups of sports students and non-athletes were studied with clinical examination, a questionnaire, standard ECG, echocardiography, and 24-h ECG (Holter) monitoring in 1985. Twenty-nine EA were re-examined with the same examinations in 2000, and in 2023, a follow-up of 24 of them was done with a questionnaire and ambulatory ECG recording, aiming at the effect of risk factors, training parameters and sex on the occurrence of AF in ExA. The ambulatory ECG recording was done with smartphone (ECG 247) for 72 h or more. Results: The mean age was 62.6 years. All had ended their competition career before the age of 39. Three had known AF, all males, with the sex difference being significant. Another two males and one female had a history of tachycardia, and the sex difference in total tachycardias was also significant. None of the ExA had asymptomatic AF. A paternal history of AF was significantly more frequent in males with AF than in males without AF. There were no significant sex differences in training parameters. Conclusions: We think our study does not support doing ambulatory ECG recording of all ExA at age 65, but one should be aware of increased risk in males with a paternal history of AF. Both AF and symptomatic tachycardias were significantly increased in males. However, the low number of AF is a limitation of these conclusions and does not permit concluding on whether training during middle age confers a higher risk of AF than training at a younger age. No sex differences in training in ExA indicate that biological factors (like hormones) contribute considerably to the sex difference in the risk of AF in ExA. Despite the low number of AF cases, we believe our study provides new knowledge as it is prospective, free of baseline selection bias, includes detailed investigations both at baseline and at follow-up, and addresses a gap in prospective studies on AF in EA.
- 1 January 2025
- Published by S. Karger AG in Biomedicine Hub
- Vol. 10 (1) , 191-196
Open AccessAtrial Fibrillation in 63-Year-Old Former Elite Endurance Athletes: A 38-Year Follow-Up Study
Introduction: There are many reports on atrial fibrillation/flutter (AF) in previous elite endurance athletes (ExA) and veteran athletes (VA), but no prospective studies on AF in elite endurance athletes (EA) have been published. Most studies are on males and increased risk in males has been found, but the explanation of this has been controversial. Methods: We present a study where 15 male and 15 female EA and matched groups of sports students and non-athletes were studied with clinical examination, a questionnaire, standard ECG, echocardiography, and 24-h ECG (Holter) monitoring in 1985. Twenty-nine EA were re-examined with the same examinations in 2000, and in 2023, a follow-up of 24 of them was done with a questionnaire and ambulatory ECG recording, aiming at the effect of risk factors, training parameters and sex on the occurrence of AF in ExA. The ambulatory ECG recording was done with smartphone (ECG 247) for 72 h or more. Results: The mean age was 62.6 years. All had ended their competition career before the age of 39. Three had known AF, all males, with the sex difference being significant. Another two males and one female had a history of tachycardia, and the sex difference in total tachycardias was also significant. None of the ExA had asymptomatic AF. A paternal history of AF was significantly more frequent in males with AF than in males without AF. There were no significant sex differences in training parameters. Conclusions: We think our study does not support doing ambulatory ECG recording of all ExA at age 65, but one should be aware of increased risk in males with a paternal history of AF. Both AF and symptomatic tachycardias were significantly increased in males. However, the low number of AF is a limitation of these conclusions and does not permit concluding on whether training during middle age confers a higher risk of AF than training at a younger age. No sex differences in training in ExA indicate that biological factors (like hormones) contribute considerably to the sex difference in the risk of AF in ExA. Despite the low number of AF cases, we believe our study provides new knowledge as it is prospective, free of baseline selection bias, includes detailed investigations both at baseline and at follow-up, and addresses a gap in prospective studies on AF in EA.
- Open Access
- 9 September 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (10)
The NORwegian atrial fibrillation self-SCREENing (NORSCREEN) trial: rationale and design of a randomized controlled trial
Aims: Atrial fibrillation (AF) is a common arrhythmia, and many cases of AF may be undiagnosed. Whether screening for AF and subsequent treatment if AF is detected can improve long-term outcome remains an unsettled question. The primary aim of the NORwegian atrial fibrillation self-SCREENing (NORSCREEN) trial is to assess whether self-screening for AF with continuous electrocardiogram (ECG) for 3–7 days in individuals aged 65 years or older with at least one additional risk factor for stroke, and initiation of guideline-recommended therapy in patients with detected AF, will reduce the occurrence of stroke. Methods and results: This study is a nationwide open, siteless, randomized, controlled trial. Individuals ≥65 years of age are randomly identified from the National Population Register of Norway and are invited to take a digital inclusion/exclusion test. Individuals passing the inclusion/exclusion test are randomized to either the intervention group or the control group. A total of 35 000 participants will be enrolled. In the intervention group, self-screening is performed continuously over 3–7 days at home with a patch ECG device (ECG247) at inclusion and after 12–18 months. If AF is detected, guideline-recommended therapy will be initiated. Patients will be followed up for 5 years through national health registries. The primary outcome is time to a first stroke (ischaemic or haemorrhagic stroke). The first participant in the NORSCREEN trial was enrolled on 1 September 2023. Conclusion: The results from the NORSCREEN trial will provide new insights regarding the efficacy of digital siteless self-screening for AF with respect to stroke prevention in individuals at an increased risk of stroke. Trial registration: Clinical trials: NCT05914883.
- 9 September 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (10)
Open AccessThe NORwegian atrial fibrillation self-SCREENing (NORSCREEN) trial: rationale and design of a randomized controlled trial
Aims: Atrial fibrillation (AF) is a common arrhythmia, and many cases of AF may be undiagnosed. Whether screening for AF and subsequent treatment if AF is detected can improve long-term outcome remains an unsettled question. The primary aim of the NORwegian atrial fibrillation self-SCREENing (NORSCREEN) trial is to assess whether self-screening for AF with continuous electrocardiogram (ECG) for 3–7 days in individuals aged 65 years or older with at least one additional risk factor for stroke, and initiation of guideline-recommended therapy in patients with detected AF, will reduce the occurrence of stroke. Methods and results: This study is a nationwide open, siteless, randomized, controlled trial. Individuals ≥65 years of age are randomly identified from the National Population Register of Norway and are invited to take a digital inclusion/exclusion test. Individuals passing the inclusion/exclusion test are randomized to either the intervention group or the control group. A total of 35 000 participants will be enrolled. In the intervention group, self-screening is performed continuously over 3–7 days at home with a patch ECG device (ECG247) at inclusion and after 12–18 months. If AF is detected, guideline-recommended therapy will be initiated. Patients will be followed up for 5 years through national health registries. The primary outcome is time to a first stroke (ischaemic or haemorrhagic stroke). The first participant in the NORSCREEN trial was enrolled on 1 September 2023. Conclusion: The results from the NORSCREEN trial will provide new insights regarding the efficacy of digital siteless self-screening for AF with respect to stroke prevention in individuals at an increased risk of stroke. Trial registration: Clinical trials: NCT05914883.
- Open Access
- 9 April 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 5 (3) , 371-378
Digital recruitment and compliance to treatment recommendations in the Norwegian Atrial Fibrillation self-screening pilot study
Atrial fibrillation (AF) is prevalent, undiagnosed in approximately one-third of cases, and is associated with severe complications. Guidelines recommend screening individuals at increased risk of stroke. This report evaluated the digital recruitment procedure and compliance with the follow-up recommendations in participants with screen-detected AF in the Norwegian Atrial Fibrillation self-screening pilot study. Norwegians ≥65 years were invited through Facebooks posts, web pages, and newspapers to participate in the study. Targeted Facebook posts promoted over 11 days reached 84 208 users and 10 582 visitors to the study homepage. This accounted for 51% of the total homepage visitors (n = 20 704). A total of 2118 (10%) of the homepage visitors provided digital consent to participate after they met the inclusion criteria. The mean (standard deviation) age of the participants was 70 (4) years, and the majority [n = 1569 (74%)] were women. A total of 1849 (87%) participants completed the electrocardiogram self-screening test, identifying AF in 41 (2.2%) individuals. Of these, 39 (95%) participants consulted a general practitioner, and 34 (83%) participants initiated anticoagulation therapy. Digital recruitment and inclusion in digital AF screening with a high rate of initiation of anticoagulation therapy in AF positive screening cases are feasible. However, digital recruitment and inclusion may introduce selection bias with regard to age and gender. Larger studies are needed to determine the efficacy and cost-effectiveness of a fully digital AF screening. Clinical trials: NCT04700865
- 9 April 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 5 (3) , 371-378
Open AccessDigital recruitment and compliance to treatment recommendations in the Norwegian Atrial Fibrillation self-screening pilot study
Atrial fibrillation (AF) is prevalent, undiagnosed in approximately one-third of cases, and is associated with severe complications. Guidelines recommend screening individuals at increased risk of stroke. This report evaluated the digital recruitment procedure and compliance with the follow-up recommendations in participants with screen-detected AF in the Norwegian Atrial Fibrillation self-screening pilot study. Norwegians ≥65 years were invited through Facebooks posts, web pages, and newspapers to participate in the study. Targeted Facebook posts promoted over 11 days reached 84 208 users and 10 582 visitors to the study homepage. This accounted for 51% of the total homepage visitors (n = 20 704). A total of 2118 (10%) of the homepage visitors provided digital consent to participate after they met the inclusion criteria. The mean (standard deviation) age of the participants was 70 (4) years, and the majority [n = 1569 (74%)] were women. A total of 1849 (87%) participants completed the electrocardiogram self-screening test, identifying AF in 41 (2.2%) individuals. Of these, 39 (95%) participants consulted a general practitioner, and 34 (83%) participants initiated anticoagulation therapy. Digital recruitment and inclusion in digital AF screening with a high rate of initiation of anticoagulation therapy in AF positive screening cases are feasible. However, digital recruitment and inclusion may introduce selection bias with regard to age and gender. Larger studies are needed to determine the efficacy and cost-effectiveness of a fully digital AF screening. Clinical trials: NCT04700865
- Open Access
- 25 March 2024
- Published by Hindawi Limited in International Journal of Telemedicine and Applications
- Vol. 2024, 1-7
Screening for Atrial Fibrillation by Digital Health Technology in Older People in Homecare Settings: A Feasibility Trial
Aims. Users of homecare services are often excluded from clinical trials due to advanced age, multimorbidity, and frailty. Atrial fibrillation (AF) is a common and frequently undiagnosed arrhythmia in the elderly and is associated with severe mortality, morbidity, and healthcare costs. Timely identification prevents associated complications through evidence-based treatment. This study is aimed at assessing the feasibility of AF screening using new digital health technology in older people in a homecare setting. Methods. Users of homecare years old with at least one additional risk factor for stroke in two Norwegian municipalities were assessed for study participation by nurses. Participants performed a continuous prolonged ECG recording using a patch ECG device (ECG247 Smart Heart Sensor). Results. A total of 144 individuals were assessed for study participation, but only 18 (13%) were included. The main reasons for noninclusion were known AF and/or anticoagulation therapy (25%), severe cognitive impairment (26%), and lack of willingness to participate (36%). The mean age of participants performing the ECG test was 81 () years, and 9 (50%) were women. All ECG tests were interpretable; the mean ECG monitoring time was 104 hours (IQR 34-338 hours). AF was detected in one individual (6%). Conclusion. This feasibility study highlights the challenges of enrolling older people receiving homecare services in clinical trials. However, all included participants performed an interpretable and prolonged continuous ECG recording with a digital ECG patch device. This trial is registered with NCT04700865.- 25 March 2024
- Published by Hindawi Limited in International Journal of Telemedicine and Applications
- Vol. 2024, 1-7
Open AccessScreening for Atrial Fibrillation by Digital Health Technology in Older People in Homecare Settings: A Feasibility Trial
Aims. Users of homecare services are often excluded from clinical trials due to advanced age, multimorbidity, and frailty. Atrial fibrillation (AF) is a common and frequently undiagnosed arrhythmia in the elderly and is associated with severe mortality, morbidity, and healthcare costs. Timely identification prevents associated complications through evidence-based treatment. This study is aimed at assessing the feasibility of AF screening using new digital health technology in older people in a homecare setting. Methods. Users of homecare years old with at least one additional risk factor for stroke in two Norwegian municipalities were assessed for study participation by nurses. Participants performed a continuous prolonged ECG recording using a patch ECG device (ECG247 Smart Heart Sensor). Results. A total of 144 individuals were assessed for study participation, but only 18 (13%) were included. The main reasons for noninclusion were known AF and/or anticoagulation therapy (25%), severe cognitive impairment (26%), and lack of willingness to participate (36%). The mean age of participants performing the ECG test was 81 () years, and 9 (50%) were women. All ECG tests were interpretable; the mean ECG monitoring time was 104 hours (IQR 34-338 hours). AF was detected in one individual (6%). Conclusion. This feasibility study highlights the challenges of enrolling older people receiving homecare services in clinical trials. However, all included participants performed an interpretable and prolonged continuous ECG recording with a digital ECG patch device. This trial is registered with NCT04700865. - Open Access
- 22 February 2024
- Published by Hindawi Limited in International Journal of Telemedicine and Applications
- Vol. 2024, 1-7
High Diagnostic Accuracy of Long-Term Electrocardiogram Interpretation by General Practitioners
Aims. Traditional long-term ECG monitoring systems have primarily been used by cardiologist. New remote and wearable easy-to-use devices have led to increased use of ECG recordings also outside cardiology clinics. The aims of this study were to assess the feasibility and diagnostic accuracy of interpretation of the one-lead ECG recordings from a patch ECG device (ECG247 Smart Heart Sensor system) by general practitioners (GP). Methods. Norwegian GPs were invited to digitally assess 10 long-term ECG recordings with different arrhythmias performed by the ECG247 Smart Heart Sensor system. For all ECG examinations, the presence/absence of different arrhythmias was registered. Results. A total of 40 GPs accepted the invitation and assessed all the 10 long-term ECG recordings. All the tests were assessed as interpretable by all the GPs. Arrhythmias (atrial fibrillation/flutter, supraventricular tachycardia, and ventricular tachycardia) were correctly identified in most cases, with sensitivity of 98 (95 CI 95-99), specificity of 75 (95 CI 68-82), and diagnostic accuracy of 89 (85-92). Incorrect automatic system algorithm interpretations were rarely corrected by the GPs. Conclusion. GPs interpreted one-lead recordings by the ECG247 Smart Heart Sensor system with high diagnostic accuracy for common arrhythmias. However, in cases with rare arrhythmias, we recommend consulting a cardiologist to confirm the diagnosis before treatment is initiated. This trial is registered with NCT04700865.
- 22 February 2024
- Published by Hindawi Limited in International Journal of Telemedicine and Applications
- Vol. 2024, 1-7
Open AccessHigh Diagnostic Accuracy of Long-Term Electrocardiogram Interpretation by General Practitioners
Aims. Traditional long-term ECG monitoring systems have primarily been used by cardiologist. New remote and wearable easy-to-use devices have led to increased use of ECG recordings also outside cardiology clinics. The aims of this study were to assess the feasibility and diagnostic accuracy of interpretation of the one-lead ECG recordings from a patch ECG device (ECG247 Smart Heart Sensor system) by general practitioners (GP). Methods. Norwegian GPs were invited to digitally assess 10 long-term ECG recordings with different arrhythmias performed by the ECG247 Smart Heart Sensor system. For all ECG examinations, the presence/absence of different arrhythmias was registered. Results. A total of 40 GPs accepted the invitation and assessed all the 10 long-term ECG recordings. All the tests were assessed as interpretable by all the GPs. Arrhythmias (atrial fibrillation/flutter, supraventricular tachycardia, and ventricular tachycardia) were correctly identified in most cases, with sensitivity of 98 (95 CI 95-99), specificity of 75 (95 CI 68-82), and diagnostic accuracy of 89 (85-92). Incorrect automatic system algorithm interpretations were rarely corrected by the GPs. Conclusion. GPs interpreted one-lead recordings by the ECG247 Smart Heart Sensor system with high diagnostic accuracy for common arrhythmias. However, in cases with rare arrhythmias, we recommend consulting a cardiologist to confirm the diagnosis before treatment is initiated. This trial is registered with NCT04700865.
- Open Access
- 22 March 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (5)
Fully digital self-screening for atrial fibrillation with patch electrocardiogram
Aims: Atrial fibrillation (AF) is the most common arrhythmia worldwide. The AF is associated with severe mortality, morbidity, and healthcare costs, and guidelines recommend screening people at risk. However, screening methods and organization still need to be clarified. The current study aimed to assess the feasibility of a fully digital self-screening procedure and to assess the prevalence of undetected AF using a continuous patch electrocardiogram (ECG) monitoring system. Methods and results: Individuals ≥65 years old with at least one additional risk factor for stroke from the general population of Norway were invited to a fully digital continuous self-screening for AF using a patch ECG device (ECG247 Smart Heart Sensor). Participants self-reported clinical characteristics and usability online, and all participants received digital feedback of their results. A total of 2118 individuals with a mean CHA2DS2-VASc risk score of 2.6 (0.9) were enrolled in the study [74% women; mean age 70.1 years (4.2)]. Of these, 1849 (87.3%) participants completed the ECG self-screening test, while 215 (10.2%) did not try to start the test and 54 (2.5%) failed to start the test. The system usability score was 84.5. The mean ECG monitoring time was 153 h (87). Atrial fibrillation was detected in 41 (2.2%) individuals. Conclusion: This fully digitalized self-screening procedure for AF demonstrated excellent feasibility. The number needed to screen was 45 to detect one unrecognized case of AF in subjects at risk for stroke. Randomized studies with long-term follow-up are needed to assess whether self-screening for AF can reduce the incidence of AF-related complications. Clinical trials: NCT04700865
- 22 March 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (5)
Open AccessFully digital self-screening for atrial fibrillation with patch electrocardiogram
Aims: Atrial fibrillation (AF) is the most common arrhythmia worldwide. The AF is associated with severe mortality, morbidity, and healthcare costs, and guidelines recommend screening people at risk. However, screening methods and organization still need to be clarified. The current study aimed to assess the feasibility of a fully digital self-screening procedure and to assess the prevalence of undetected AF using a continuous patch electrocardiogram (ECG) monitoring system. Methods and results: Individuals ≥65 years old with at least one additional risk factor for stroke from the general population of Norway were invited to a fully digital continuous self-screening for AF using a patch ECG device (ECG247 Smart Heart Sensor). Participants self-reported clinical characteristics and usability online, and all participants received digital feedback of their results. A total of 2118 individuals with a mean CHA2DS2-VASc risk score of 2.6 (0.9) were enrolled in the study [74% women; mean age 70.1 years (4.2)]. Of these, 1849 (87.3%) participants completed the ECG self-screening test, while 215 (10.2%) did not try to start the test and 54 (2.5%) failed to start the test. The system usability score was 84.5. The mean ECG monitoring time was 153 h (87). Atrial fibrillation was detected in 41 (2.2%) individuals. Conclusion: This fully digitalized self-screening procedure for AF demonstrated excellent feasibility. The number needed to screen was 45 to detect one unrecognized case of AF in subjects at risk for stroke. Randomized studies with long-term follow-up are needed to assess whether self-screening for AF can reduce the incidence of AF-related complications. Clinical trials: NCT04700865
- Open Access
- 6 April 2022
- Published by BMJ in Open Heart
- Vol. 9 (1) , e001934
Time trends in adherence to guideline recommendations for anticoagulation therapy in patients with atrial fibrillation and myocardial infarction
Background Poor adherence to guideline recommendations for anticoagulation in patients with acute myocardial infarction (MI) and atrial fibrillation (AF) is previously reported. The aim of the present cohort study was to assess time trends in prescription of anticoagulation therapy in a nationwide registry-based cohort of patients with acute MI and AF. Methods All patients, registered in the Norwegian Myocardial Infarction Registry (NORMI) between 2013 and 2019 with ECG-verified AF at hospitalisation, were included in the cohort study. The primary outcome was the prescription rate of anticoagulation therapy at hospital discharge and follow-up through 2019. Results AF was observed in 8565 (10.9% of 78369) patients registered in the NORMI from 2013 through 2019. The congestive heart failure, hypertension, age ≥75 (doubled), diabetes, stroke (doubled), vascular disease, age 65–75, and sex (female) score was ≥2 in 7845 (92%) of the hospitalised patients with AF, and in 7174 (96%) of 7440 patients discharged alive. Only 3704 (47.2%) of these patients were treated with anticoagulation prior to the MI. The prescription rate of anticoagulation therapy at discharge was 55% in 2013, increasing to 78% in 2019 (annual per cent change 6.0 (95% CI 0.7 to 11.6)). Patients prescribed anticoagulation therapy had reduced risk of all types of stroke or death at follow-up compared with patients without prescription of anticoagulation therapy (multivariate-adjusted HR 0.8, 95% CI 0.7 to 0.8, pConclusions The prescription rate of anticoagulation therapy in patients with MI and AF increased during the study period, but many patients were still undertreated with respect to stroke prevention.
- 6 April 2022
- Published by BMJ in Open Heart
- Vol. 9 (1) , e001934
Open AccessTime trends in adherence to guideline recommendations for anticoagulation therapy in patients with atrial fibrillation and myocardial infarction
Background Poor adherence to guideline recommendations for anticoagulation in patients with acute myocardial infarction (MI) and atrial fibrillation (AF) is previously reported. The aim of the present cohort study was to assess time trends in prescription of anticoagulation therapy in a nationwide registry-based cohort of patients with acute MI and AF. Methods All patients, registered in the Norwegian Myocardial Infarction Registry (NORMI) between 2013 and 2019 with ECG-verified AF at hospitalisation, were included in the cohort study. The primary outcome was the prescription rate of anticoagulation therapy at hospital discharge and follow-up through 2019. Results AF was observed in 8565 (10.9% of 78369) patients registered in the NORMI from 2013 through 2019. The congestive heart failure, hypertension, age ≥75 (doubled), diabetes, stroke (doubled), vascular disease, age 65–75, and sex (female) score was ≥2 in 7845 (92%) of the hospitalised patients with AF, and in 7174 (96%) of 7440 patients discharged alive. Only 3704 (47.2%) of these patients were treated with anticoagulation prior to the MI. The prescription rate of anticoagulation therapy at discharge was 55% in 2013, increasing to 78% in 2019 (annual per cent change 6.0 (95% CI 0.7 to 11.6)). Patients prescribed anticoagulation therapy had reduced risk of all types of stroke or death at follow-up compared with patients without prescription of anticoagulation therapy (multivariate-adjusted HR 0.8, 95% CI 0.7 to 0.8, pConclusions The prescription rate of anticoagulation therapy in patients with MI and AF increased during the study period, but many patients were still undertreated with respect to stroke prevention.
- Open Access
- 2 November 2021
- Published by Hindawi Limited in Journal of Healthcare Engineering
- Vol. 2021, 1-8
Diagnostic Accuracy and Usability of the ECG247 Smart Heart Sensor Compared to Conventional Holter Technology
Background. Heart rhythm disorders, especially atrial fibrillation (AF), are increasing global health challenges. Conventional diagnostic tools for assessment of rhythm disorders suffer from limited availability, limited test duration time, and usability challenges. There is also a need for out-of-hospital investigation of arrhythmias. Therefore, the Norwegian ECG247 Smart Heart Sensor has been developed to simplify the assessment of heart rhythm disorders. The current study aimed to evaluate the diagnostic accuracy and usability of the ECG247 Smart Heart Sensor compared to conventional Holter monitors. Methods. Parallel tests with ECG247 Smart Heart Sensor and a Holter monitor were performed in 151 consecutive patients referred for out-of-hospital long-term ECG recording at Sorlandet Hospital Arendal, Norway. All ECG data were automatically analysed by both systems and evaluated by hospital physicians. Participants were asked to complete a questionnaire scoring usability parameters after the test. Results. A total of 150 patients (62% men, age 54 (±17) years) completed the study. The ECG quality from both monitors was considered satisfactory for rhythm analysis in all patients. AF was identified in 9 (6%) patients during the period with parallel tests. The diagnostic accuracy for automatic AF detection was 95% (95% CI 91–98) for the ECG247 Smart Heart Sensor and 81% (95% CI 74–87) for the Holter system. The proportion of false-positive AF was 4% in tests analysed by the ECG247 algorithm and 16% in tests analysed by the Holter algorithm. Other arrhythmias were absent/rare. The system usability score was significantly better for ECG247 Smart Heart Sensor compared to traditional Holter technology (score 87.4 vs. 67.5, ). Conclusions. The ECG247 Smart Heart Sensor showed at least comparable diagnostic accuracy for AF and improved usability compared to conventional Holter technology. ECG247 allows for prolonged monitoring and may improve detection of AF. This trial is registered with https://clinicaltrials.gov/ct2/show/NCT04700865.
- 2 November 2021
- Published by Hindawi Limited in Journal of Healthcare Engineering
- Vol. 2021, 1-8
Open AccessDiagnostic Accuracy and Usability of the ECG247 Smart Heart Sensor Compared to Conventional Holter Technology
Background. Heart rhythm disorders, especially atrial fibrillation (AF), are increasing global health challenges. Conventional diagnostic tools for assessment of rhythm disorders suffer from limited availability, limited test duration time, and usability challenges. There is also a need for out-of-hospital investigation of arrhythmias. Therefore, the Norwegian ECG247 Smart Heart Sensor has been developed to simplify the assessment of heart rhythm disorders. The current study aimed to evaluate the diagnostic accuracy and usability of the ECG247 Smart Heart Sensor compared to conventional Holter monitors. Methods. Parallel tests with ECG247 Smart Heart Sensor and a Holter monitor were performed in 151 consecutive patients referred for out-of-hospital long-term ECG recording at Sorlandet Hospital Arendal, Norway. All ECG data were automatically analysed by both systems and evaluated by hospital physicians. Participants were asked to complete a questionnaire scoring usability parameters after the test. Results. A total of 150 patients (62% men, age 54 (±17) years) completed the study. The ECG quality from both monitors was considered satisfactory for rhythm analysis in all patients. AF was identified in 9 (6%) patients during the period with parallel tests. The diagnostic accuracy for automatic AF detection was 95% (95% CI 91–98) for the ECG247 Smart Heart Sensor and 81% (95% CI 74–87) for the Holter system. The proportion of false-positive AF was 4% in tests analysed by the ECG247 algorithm and 16% in tests analysed by the Holter algorithm. Other arrhythmias were absent/rare. The system usability score was significantly better for ECG247 Smart Heart Sensor compared to traditional Holter technology (score 87.4 vs. 67.5, ). Conclusions. The ECG247 Smart Heart Sensor showed at least comparable diagnostic accuracy for AF and improved usability compared to conventional Holter technology. ECG247 allows for prolonged monitoring and may improve detection of AF. This trial is registered with https://clinicaltrials.gov/ct2/show/NCT04700865.