Hassan M. Ahmed
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hassan M. Ahmed has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Nancy M. Salem
Biomedical Engineering Department, Helwan University, Helwan, Egypt
3 shared publications- Nancy M. Salem
Biomedical Engineering Department, Helwan University, Cairo, Egypt
3 shared publications Walid Al-Atabany
Biomedical Engineering Department, Helwan University, Helwan, Egypt
3 shared publications- Walid Al-Atabany
Nile University
2 shared publications - Ahmed Farag Seddik
Biomedical Engineering Department, Helwan University, Cairo, Egypt
1 shared publication - Ayman M. El-Tager
Electronic Engineering Department, Military Technical College, Cairo, Egypt
1 shared publication
Latest Publications
- Open Access
- 5 June 2023
- Published by Springer Nature in BMC Ophthalmology
- Vol. 23 (1) , 1-9
Human cornea thermo-viscoelastic behavior modelling using standard linear solid model
Background: Corneal biomechanics is of great interest to researchers recently. Clinical findings relate them to corneal diseases and to outcomes of refractive surgery. To have a solid understanding of corneal diseases’ progression, it is important to understand corneal biomechanics. Also, they are essential for better explaining outcomes of refractive surgeries and their undesired consequences. There is a difficulty for studying corneal biomechanics in-vivo and multiple limitations arise for ex-vivo studies. Hence mathematical modelling is considered as a proper solution to overcome such obstacles. Mathematical modelling of cornea in-vivo allows studying corneal viscoelasticity with taking into consideration all boundary conditions existing in real in-vivo situation. Methods: Three mathematical models are used to simulate corneal viscoelasticity and thermal behavior in two different loading situations: constant and transient loading. Two models of the three are used for viscoelasticity simulation which are Kelvin-Voigt and standard linear solid models. Also, temperature rise due to the ultrasound pressure push is calculated using bioheat transfer model for both the axial direction and as a 2D spatial map using the third model (standard linear solid model). Results: Viscoelasticity simulation results show that standard linear solid model is efficient for describing the viscoelastic behavior of human cornea in both loading conditions. Results show also that the deformation amplitude obtained from standard linear solid model is more reasonable for corneal soft-tissue deformation with respect to corresponding clinical findings than that obtained from Kelvin-Voigt model. Thermal behavior results estimated corneal temperature rise to be roughly 0.2 °C, which conforms with FDA regulations for soft tissue safety. Conclusion: Standard Linear Solid (SLS) model is better describing the human corneal behavior in response to constant and transient load more efficiently. Temperature rise (TR) for the corneal tissue of about 0.2 °C is conforming with FDA regulations and even less than the FDA regulations for soft tissue safety.
- 5 June 2023
- Published by Springer Nature in BMC Ophthalmology
- Vol. 23 (1) , 1-9
Open AccessHuman cornea thermo-viscoelastic behavior modelling using standard linear solid model
Background: Corneal biomechanics is of great interest to researchers recently. Clinical findings relate them to corneal diseases and to outcomes of refractive surgery. To have a solid understanding of corneal diseases’ progression, it is important to understand corneal biomechanics. Also, they are essential for better explaining outcomes of refractive surgeries and their undesired consequences. There is a difficulty for studying corneal biomechanics in-vivo and multiple limitations arise for ex-vivo studies. Hence mathematical modelling is considered as a proper solution to overcome such obstacles. Mathematical modelling of cornea in-vivo allows studying corneal viscoelasticity with taking into consideration all boundary conditions existing in real in-vivo situation. Methods: Three mathematical models are used to simulate corneal viscoelasticity and thermal behavior in two different loading situations: constant and transient loading. Two models of the three are used for viscoelasticity simulation which are Kelvin-Voigt and standard linear solid models. Also, temperature rise due to the ultrasound pressure push is calculated using bioheat transfer model for both the axial direction and as a 2D spatial map using the third model (standard linear solid model). Results: Viscoelasticity simulation results show that standard linear solid model is efficient for describing the viscoelastic behavior of human cornea in both loading conditions. Results show also that the deformation amplitude obtained from standard linear solid model is more reasonable for corneal soft-tissue deformation with respect to corresponding clinical findings than that obtained from Kelvin-Voigt model. Thermal behavior results estimated corneal temperature rise to be roughly 0.2 °C, which conforms with FDA regulations for soft tissue safety. Conclusion: Standard Linear Solid (SLS) model is better describing the human corneal behavior in response to constant and transient load more efficiently. Temperature rise (TR) for the corneal tissue of about 0.2 °C is conforming with FDA regulations and even less than the FDA regulations for soft tissue safety.
- Open Access
- 1 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 116107-116119
Long Gaps Missing IoT Sensors Time Series Data Imputation: A Bayesian Gaussian Approach
Missing sensor data is a common problem associated with the Internet of Things (IoT) ecosystems, which affect the accuracy of the associated services such as adequate medical intervention for older adults living at home. This problem is caused by many factors, power down is one of them, communication failure and sensor failure are another two reasons. Multiple missing data imputation methods have been developed to solve this issue. However, irregular temporal missing data locations is challenging to handle, due to lack of knowledge of their occurrence probability and their random temporal location. In this paper, we propose a Bayesian Gaussian Process based imputation technique that accounts for temporal forcing to fill in the missing sensor data. Our approach; Bayesian Gaussian Process (BGaP); can impute missing data efficiently at any missing rate and for any temporal location using prior knowledge gathered on past observations. We illustrated how our approach performs using real data collected from sensors deployed in the residence of 10 older adults over a two-year period. Using our novel approach, we were able to impute all the missing data which allowed us to observe long-term behavior changes that we would not have been able to observe otherwise.
- 1 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 116107-116119
Open AccessLong Gaps Missing IoT Sensors Time Series Data Imputation: A Bayesian Gaussian Approach
Missing sensor data is a common problem associated with the Internet of Things (IoT) ecosystems, which affect the accuracy of the associated services such as adequate medical intervention for older adults living at home. This problem is caused by many factors, power down is one of them, communication failure and sensor failure are another two reasons. Multiple missing data imputation methods have been developed to solve this issue. However, irregular temporal missing data locations is challenging to handle, due to lack of knowledge of their occurrence probability and their random temporal location. In this paper, we propose a Bayesian Gaussian Process based imputation technique that accounts for temporal forcing to fill in the missing sensor data. Our approach; Bayesian Gaussian Process (BGaP); can impute missing data efficiently at any missing rate and for any temporal location using prior knowledge gathered on past observations. We illustrated how our approach performs using real data collected from sensors deployed in the residence of 10 older adults over a two-year period. Using our novel approach, we were able to impute all the missing data which allowed us to observe long-term behavior changes that we would not have been able to observe otherwise.
- Open Access
- 3 October 2022
- Published by Springer Nature in Research Square
Mathematical Modelling for Cornea Viscoelastic and Thermal Behavior
Corneal biomechanics is of great interest to researchers recently. Clinical findings relate them to corneal diseases and to outcomes of refractive surgery. To have a solid understanding of corneal diseases’ progression, it is important to understand corneal biomechanics. Also, they are essential for better explaining outcomes of refractive surgeries and their undesired consequences. There is a difficulty for studying corneal biomechanics in-vivo and multiple limitations arise for ex-vivo studies. Hence mathematical modelling is considered as a proper solution to overcome such obstacles. Mathematical modelling of cornea in-vivo allows studying corneal viscoelasticity with taking into consideration all boundary conditions existing in real in-vivo situation. In this paper, three mathematical models are used to simulate corneal viscoelasticity and thermal behavior in two different loading situations: constant and transient loading. Two models of the three are used for viscoelasticity simulation which are Kelvin-Voigt and standard linear solid models. Viscoelasticity simulation results show that standard linear solid model is efficient for describing the viscoelastic behavior of human cornea in both loading conditions. Results show also that the deformation amplitude obtained from standard linear solid model is more reasonable for corneal soft-tissue deformation with respect to corresponding clinical findings than that obtained from Kelvin-Voigt model. Also, temperature rise due to the ultrasound pressure push is calculated using bioheat transfer model for both the axial direction and as a 2D spatial map using the third model. Thermal behavior results estimated corneal temperature rise to be about 0.2°C, which conforms with FDA regulations for soft tissue safety.
- 3 October 2022
- Published by Springer Nature in Research Square
Open AccessMathematical Modelling for Cornea Viscoelastic and Thermal Behavior
Corneal biomechanics is of great interest to researchers recently. Clinical findings relate them to corneal diseases and to outcomes of refractive surgery. To have a solid understanding of corneal diseases’ progression, it is important to understand corneal biomechanics. Also, they are essential for better explaining outcomes of refractive surgeries and their undesired consequences. There is a difficulty for studying corneal biomechanics in-vivo and multiple limitations arise for ex-vivo studies. Hence mathematical modelling is considered as a proper solution to overcome such obstacles. Mathematical modelling of cornea in-vivo allows studying corneal viscoelasticity with taking into consideration all boundary conditions existing in real in-vivo situation. In this paper, three mathematical models are used to simulate corneal viscoelasticity and thermal behavior in two different loading situations: constant and transient loading. Two models of the three are used for viscoelasticity simulation which are Kelvin-Voigt and standard linear solid models. Viscoelasticity simulation results show that standard linear solid model is efficient for describing the viscoelastic behavior of human cornea in both loading conditions. Results show also that the deformation amplitude obtained from standard linear solid model is more reasonable for corneal soft-tissue deformation with respect to corresponding clinical findings than that obtained from Kelvin-Voigt model. Also, temperature rise due to the ultrasound pressure push is calculated using bioheat transfer model for both the axial direction and as a 2D spatial map using the third model. Thermal behavior results estimated corneal temperature rise to be about 0.2°C, which conforms with FDA regulations for soft tissue safety.
- Open Access
- 14 September 2022
- Published by Springer Nature in Research Square
Finite Element Modelling of Corneal Biomechanics Assessment Using Ultrasonic Elastography
Corneal diseases affect corneal tissue shape and its biomechanics leading to a degradation ofthe overall vision quality. Refractive surgeries restore corneal refractive power. However, its outcomes arehighly dependent on corneal biomechanics pre-surgery while changing corneal biomechanics post-surgery.Cornea behavior is obtained by estimation of corneal biomechanics pre- and post-refractive surgeries eitherex- or in-vivo. Demand for non-invasive in-vivo measurement is highly recommended as it preserves bothcorneal shape and structure on contrary to invasive ex-vivo methods. Until now no clinically reported in-vivodevice offering corneal biomechanics spatial distribution exists. In this research, ultrasonic noninvasive invivomeasurement for estimating corneal biomechanics using FEM simulation is proposed. Eleven differentelastic moduli FEMs are used to cover the range of elasticity of human cornea in normal and pathogenicstatus. Two ultrasonic tissue deformation measurement methods are used in this study. Namely, the radialShear Wave Speed (rSWS) and Focal Peak Axial Deformation (FPAD). rSWS utilizes two B-mode framerates; 10kHz and 100KHz typically. FPAD uses 100KHz for tissue deformation data collection. Twomathematical formulae for prediction of non-involved data points are power formula and logarithmic formulaare used. Simulation results shown that rSWS is efficient for high frame rate transducer. Accuracy of99.8%±2.4% is achieved with 100KHz while for 10KHz the accuracy is 95.5%±29%. Results shown also,that accuracy at 100KHz is nearly stable on contrary to highly fluctuating accuracy at 10KHz. FPAD shownthat logarithmic formula is optimum with Mean Square Error (MSE) of 0.006, compared to MSE of 0.09 forpower formula. FPAD has an advantage over rSWS to be implemented with low frame rate transducers whilerSWS has the advantage of quantitative measurement. Maximum temperature rise of 0.9 C is achieved dueto the ARFI where this value is under the FDA regulation.
- 14 September 2022
- Published by Springer Nature in Research Square
Open AccessFinite Element Modelling of Corneal Biomechanics Assessment Using Ultrasonic Elastography
Corneal diseases affect corneal tissue shape and its biomechanics leading to a degradation ofthe overall vision quality. Refractive surgeries restore corneal refractive power. However, its outcomes arehighly dependent on corneal biomechanics pre-surgery while changing corneal biomechanics post-surgery.Cornea behavior is obtained by estimation of corneal biomechanics pre- and post-refractive surgeries eitherex- or in-vivo. Demand for non-invasive in-vivo measurement is highly recommended as it preserves bothcorneal shape and structure on contrary to invasive ex-vivo methods. Until now no clinically reported in-vivodevice offering corneal biomechanics spatial distribution exists. In this research, ultrasonic noninvasive invivomeasurement for estimating corneal biomechanics using FEM simulation is proposed. Eleven differentelastic moduli FEMs are used to cover the range of elasticity of human cornea in normal and pathogenicstatus. Two ultrasonic tissue deformation measurement methods are used in this study. Namely, the radialShear Wave Speed (rSWS) and Focal Peak Axial Deformation (FPAD). rSWS utilizes two B-mode framerates; 10kHz and 100KHz typically. FPAD uses 100KHz for tissue deformation data collection. Twomathematical formulae for prediction of non-involved data points are power formula and logarithmic formulaare used. Simulation results shown that rSWS is efficient for high frame rate transducer. Accuracy of99.8%±2.4% is achieved with 100KHz while for 10KHz the accuracy is 95.5%±29%. Results shown also,that accuracy at 100KHz is nearly stable on contrary to highly fluctuating accuracy at 10KHz. FPAD shownthat logarithmic formula is optimum with Mean Square Error (MSE) of 0.006, compared to MSE of 0.09 forpower formula. FPAD has an advantage over rSWS to be implemented with low frame rate transducers whilerSWS has the advantage of quantitative measurement. Maximum temperature rise of 0.9 C is achieved dueto the ARFI where this value is under the FDA regulation.
- 1 October 2021
- Published by Wolters Kluwer Health in Journal of Clinical Engineering
- Vol. 46 (4) , 177-188
Impact of Post–Refractive Surgeries on Corneal Biomechanics—A Review
A stable shape for the human cornea prevents complications of post–refractive surgeries. Variation in corneal lamellae and collagen fibers is induced by recent laser refractive surgical procedures utilizing laser ablation and disruption techniques. Noninvasive prediction of corneal biomechanics and structural strength is not quite accurate pre– and post–refractive surgery despite the great advance in assessment methods. This is due to the alteration happening to the corneal structure post–refractive surgery. Many different methods have been developed to measure corneal and subcorneal biomechanics. In this article, an overview of the impact of post–refractive surgeries on corneal biomechanics is presented. The corneal anatomy and physiology are reviewed. Refractive disorders, their corresponding surgeries, and their relation to corneal biomechanics are discussed as well. Ultrasonic estimation of corneal biomechanics and their limitations are stated in this overview.
- 1 October 2021
- Published by Wolters Kluwer Health in Journal of Clinical Engineering
- Vol. 46 (4) , 177-188
Impact of Post–Refractive Surgeries on Corneal Biomechanics—A Review
A stable shape for the human cornea prevents complications of post–refractive surgeries. Variation in corneal lamellae and collagen fibers is induced by recent laser refractive surgical procedures utilizing laser ablation and disruption techniques. Noninvasive prediction of corneal biomechanics and structural strength is not quite accurate pre– and post–refractive surgery despite the great advance in assessment methods. This is due to the alteration happening to the corneal structure post–refractive surgery. Many different methods have been developed to measure corneal and subcorneal biomechanics. In this article, an overview of the impact of post–refractive surgeries on corneal biomechanics is presented. The corneal anatomy and physiology are reviewed. Refractive disorders, their corresponding surgeries, and their relation to corneal biomechanics are discussed as well. Ultrasonic estimation of corneal biomechanics and their limitations are stated in this overview.
- Open Access
- 26 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 106014-106028
Corneal Biomechanics Assessment Using High Frequency Ultrasound B-Mode Imaging
Assessment of corneal biomechanics for pre- and post-refractive surgery is of great clinical importance. Corneal biomechanics affect vision quality of human eye. Many factors affect corneal biomechanics such as, age, corneal diseases and corneal refractive surgery. There is a need for non-invasive in-vivo measurement of corneal biomechanics due to corneal shape preserving as opposed to ex-vivo measurements that destructs corneal tissue. In this study, a new approach for assessing corneal biomechanics in-vivo non-invasively using ultrasound estimation method with 100 KHz frame rate is proposed. Three models in conjunction with each other are used to study the biomechanics behavior of corneal tissue pre- and post-refractive surgery. These three models are cornea FEM, cornea scatterrer model and ultrasound transducer model respectively. Nine different elastic moduli corneal models are constructed to achieve this goal; 140KPa, 300KPa, 600KPa and 800KPa as post-refractive surgery models and 1MPa, 1.5MPa, 2MPa, 2.5MPa and 3MPa as pre-refractive surgery models respectively. Time-To-Peak (TTP) deformation, deformation amplitude (DA), deformation amplitude ratio at 2 mm (DA ratio 2 mm) and shear wave speed (SWS) are estimated for each of the nine involved corneal models in this study. Results show that, TTP is decreasing (6.9 msec. at 140KPa to 5.3 msec. at 3MPa) while increasing the elastic modulus of corneal tissue. Also, DA is decreasing (2 mm at 140KPa to 0.5 mm at 3MPa), while increasing the elastic modulus as well. However, DA ratio shows decrease while increasing of elastic modulus to reflect the difficulty of corneal tissue to deform uniformly at higher elastic moduli. Estimated SWS shows an average accuracy of 98% of the theoretical SWS.
- 26 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 106014-106028
Open AccessCorneal Biomechanics Assessment Using High Frequency Ultrasound B-Mode Imaging
Assessment of corneal biomechanics for pre- and post-refractive surgery is of great clinical importance. Corneal biomechanics affect vision quality of human eye. Many factors affect corneal biomechanics such as, age, corneal diseases and corneal refractive surgery. There is a need for non-invasive in-vivo measurement of corneal biomechanics due to corneal shape preserving as opposed to ex-vivo measurements that destructs corneal tissue. In this study, a new approach for assessing corneal biomechanics in-vivo non-invasively using ultrasound estimation method with 100 KHz frame rate is proposed. Three models in conjunction with each other are used to study the biomechanics behavior of corneal tissue pre- and post-refractive surgery. These three models are cornea FEM, cornea scatterrer model and ultrasound transducer model respectively. Nine different elastic moduli corneal models are constructed to achieve this goal; 140KPa, 300KPa, 600KPa and 800KPa as post-refractive surgery models and 1MPa, 1.5MPa, 2MPa, 2.5MPa and 3MPa as pre-refractive surgery models respectively. Time-To-Peak (TTP) deformation, deformation amplitude (DA), deformation amplitude ratio at 2 mm (DA ratio 2 mm) and shear wave speed (SWS) are estimated for each of the nine involved corneal models in this study. Results show that, TTP is decreasing (6.9 msec. at 140KPa to 5.3 msec. at 3MPa) while increasing the elastic modulus of corneal tissue. Also, DA is decreasing (2 mm at 140KPa to 0.5 mm at 3MPa), while increasing the elastic modulus as well. However, DA ratio shows decrease while increasing of elastic modulus to reflect the difficulty of corneal tissue to deform uniformly at higher elastic moduli. Estimated SWS shows an average accuracy of 98% of the theoretical SWS.
- 1 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 35-40
Investigating Relationship Between Lateral Time-To-Peak (TTP) Displacement Curves and Stiffness of Viscoelastic Agar-Gelatin Phantoms
Shear wave speed is a metric for the tissue elastic properties and its pathologic changes. This is due to the implicit relationship between the speed of the propagating shear wave within tissue and both its elastic properties and pathologic changes. Wave propagation is a result of a force applied transiently to the tissue model. In this paper, the relationship between lateral TTP displacement curves and stiffness of different Young's moduli phantoms is investigated. Five different elastic moduli Finite Element Models (FEMs) are used; 5.2KPa, 9.8KPa, 23.9KPa, 44.2KPa and 67.3KPa. Agar-gelatin model is used as a general model for mimicking soft tissue. Displacements are tracked with respect to the simulation time to create the displacement magnitude profile for the central node for each phantom. Results have shown that the second highest peak happens after 0.05 seconds in case of low elastic moduli FEMs. This time stamp can be used as a yardstick to differentiate between low and high elastic moduli without considering estimating the shear wave speed for many lateral nodes.
- 1 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 35-40
Investigating Relationship Between Lateral Time-To-Peak (TTP) Displacement Curves and Stiffness of Viscoelastic Agar-Gelatin Phantoms
Shear wave speed is a metric for the tissue elastic properties and its pathologic changes. This is due to the implicit relationship between the speed of the propagating shear wave within tissue and both its elastic properties and pathologic changes. Wave propagation is a result of a force applied transiently to the tissue model. In this paper, the relationship between lateral TTP displacement curves and stiffness of different Young's moduli phantoms is investigated. Five different elastic moduli Finite Element Models (FEMs) are used; 5.2KPa, 9.8KPa, 23.9KPa, 44.2KPa and 67.3KPa. Agar-gelatin model is used as a general model for mimicking soft tissue. Displacements are tracked with respect to the simulation time to create the displacement magnitude profile for the central node for each phantom. Results have shown that the second highest peak happens after 0.05 seconds in case of low elastic moduli FEMs. This time stamp can be used as a yardstick to differentiate between low and high elastic moduli without considering estimating the shear wave speed for many lateral nodes.
- 1 December 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Design of a transceiver RF front-end for 2.45 GHz RFID readers
In this paper, a system level design of a 2.45 GHz RFID reader transceiver front-end for the entire 2400-2483.5MHz RFID band supporting ISO 18000-4 standard is presented. Based on the physical layer parameters of the mentioned standard, and given required antenna gain, the transceiver architecture is chosen, designed and optimized for optimum sensitivity, linearity and noise figure using link budget simulation. A direct conversion architecture is adopted for the receiver for a high level of integration and low power consumption, while a double conversion architecture - based on a GMSK modulator - is used for the transmit chain. To validate the proposed system level design, practical building blocks from different RF/Microwave vendors are used to implement the transceiver. Link budget and envelope simulations are used to quantify the operation of the designed RFID reader. For a read range of 20m, and using a transmitted power of 27dBm, at a data rate of 384Kbit/s, the reader has a P1dB of 5dBm, sensitivity of -95dBm, while achieving a noise figure of 4dB.
- 1 December 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Design of a transceiver RF front-end for 2.45 GHz RFID readers
In this paper, a system level design of a 2.45 GHz RFID reader transceiver front-end for the entire 2400-2483.5MHz RFID band supporting ISO 18000-4 standard is presented. Based on the physical layer parameters of the mentioned standard, and given required antenna gain, the transceiver architecture is chosen, designed and optimized for optimum sensitivity, linearity and noise figure using link budget simulation. A direct conversion architecture is adopted for the receiver for a high level of integration and low power consumption, while a double conversion architecture - based on a GMSK modulator - is used for the transmit chain. To validate the proposed system level design, practical building blocks from different RF/Microwave vendors are used to implement the transceiver. Link budget and envelope simulations are used to quantify the operation of the designed RFID reader. For a read range of 20m, and using a transmitted power of 27dBm, at a data rate of 384Kbit/s, the reader has a P1dB of 5dBm, sensitivity of -95dBm, while achieving a noise figure of 4dB.