Xiaoxuan Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Xiaoxuan Xie has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Xiangyang Zhou
Beihang University
14 shared publications - Weiqian Wang
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
13 shared publications - Fengwen Zhao
National Institute of Extremely-Weak Magnetic Field Infrastructure, Hangzhou, China
9 shared publications - Chuanming Yin
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
3 shared publications - Jinguo Mu
Beihang University
3 shared publications - Jinji Sun
Beihang University
3 shared publications
Latest Publications
- 14 August 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (32) , 325106
Design of high-uniformity biplanar coils for NMRG based on improved sparrow search algorithm
A highly uniform magnetic field is critical to the performance of nuclear magnetic resonance gyroscope. However, the conventional target field method (TFM) for designing high-uniformity magnetic field coils (HUMFCs) relies on empirically chosen regularization parameters, leading to limited magnetic field uniformity. Although the sparrow search algorithm (SSA) shows advantages over classical algorithms such as particle swarm optimization, genetic algorithms, and gray wolf optimization in TFM-related optimization, it still suffers from slow convergence and low precision. To solve these problems, this paper proposes a novel HUMFC design method that combines TFM with an improved SSA (ISSA). The SSA is specifically enhanced for uniformity optimization via three strategies: optimized population initialization, improved individual update mechanism, and enhanced population diversity, thereby strengthening its global search ability and convergence performance. Finite element simulation shows that ISSA reduces the maximum magnetic field non-uniformity in the X and Z directions from 0.798% and 0.667% to 0.211% and 0.048%, respectively. Experiments on a 20:1 scaled prototype yield non-uniformity of 0.322% in the X -direction and 0.142% in the Z -direction, representing reductions of 72.5% and 80.5%, respectively, compared to the empirical method, which agree well with the simulations, validating the effectiveness of the proposed method.
- 14 August 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (32) , 325106
Design of high-uniformity biplanar coils for NMRG based on improved sparrow search algorithm
A highly uniform magnetic field is critical to the performance of nuclear magnetic resonance gyroscope. However, the conventional target field method (TFM) for designing high-uniformity magnetic field coils (HUMFCs) relies on empirically chosen regularization parameters, leading to limited magnetic field uniformity. Although the sparrow search algorithm (SSA) shows advantages over classical algorithms such as particle swarm optimization, genetic algorithms, and gray wolf optimization in TFM-related optimization, it still suffers from slow convergence and low precision. To solve these problems, this paper proposes a novel HUMFC design method that combines TFM with an improved SSA (ISSA). The SSA is specifically enhanced for uniformity optimization via three strategies: optimized population initialization, improved individual update mechanism, and enhanced population diversity, thereby strengthening its global search ability and convergence performance. Finite element simulation shows that ISSA reduces the maximum magnetic field non-uniformity in the X and Z directions from 0.798% and 0.667% to 0.211% and 0.048%, respectively. Experiments on a 20:1 scaled prototype yield non-uniformity of 0.322% in the X -direction and 0.142% in the Z -direction, representing reductions of 72.5% and 80.5%, respectively, compared to the empirical method, which agree well with the simulations, validating the effectiveness of the proposed method.
- 17 July 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (28) , 285110
A disturbance-aware temperature compensation method for sensitivity stability of atomic sensors under thermal disturbances
Atomic sensors used for high-sensitivity magnetic-field and inertial measurements are susceptible to thermal disturbances, which cause temperature fluctuations, optical-depth variations, and sensitivity degradation. This paper proposes a disturbance-aware temperature compensation method that integrates multi-point temperature measurements, a gray-box thermal network model, and long short-term memory network-based deep deterministic policy gradient control. By using this method, the disturbance rejection ability under time-varying thermal conditions is enhanced, helping improve sensitivity stability during disturbance recovery. To validate the effectiveness of the proposed method, experiments were conducted. Compared with the tested PID and Fuzzy PID methods, the peak temperature deviation and the peak-to-peak optical depth deviation of the proposed method are reduced by up to 44.7% and 63.0%, respectively, indicating that the influence of thermal disturbances on the measured sensor response is reduced under the tested conditions.
- 17 July 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (28) , 285110
A disturbance-aware temperature compensation method for sensitivity stability of atomic sensors under thermal disturbances
Atomic sensors used for high-sensitivity magnetic-field and inertial measurements are susceptible to thermal disturbances, which cause temperature fluctuations, optical-depth variations, and sensitivity degradation. This paper proposes a disturbance-aware temperature compensation method that integrates multi-point temperature measurements, a gray-box thermal network model, and long short-term memory network-based deep deterministic policy gradient control. By using this method, the disturbance rejection ability under time-varying thermal conditions is enhanced, helping improve sensitivity stability during disturbance recovery. To validate the effectiveness of the proposed method, experiments were conducted. Compared with the tested PID and Fuzzy PID methods, the peak temperature deviation and the peak-to-peak optical depth deviation of the proposed method are reduced by up to 44.7% and 63.0%, respectively, indicating that the influence of thermal disturbances on the measured sensor response is reduced under the tested conditions.
- 9 June 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (26)
Parametric modeling and neural-network-based prediction of cylindrical-spherical-cap magnetic shielding devices
This paper presents a rapid parametric modeling and prediction framework for cylindrical-spherical-cap magnetic shielding devices (MSDs), in which BPNN-predicted effective permeability is combined with shell-element simulation to enable efficient performance estimation and provide guidance for preliminary engineering design in precision measurement environments. The parameters of the Jiles-Atherton model are identified from measured hysteresis loops of permalloy, and the resulting anhysteretic magnetization curve is used to construct the material constitutive relation for finite element analysis. Based on shell-element simulations, the effects of structural parameters on the effective average permeability are investigated. A neural-network model is further developed to establish a rapid mapping between geometric parameters and effective permeability, thereby reducing the computational cost of direct full-thickness nonlinear simulations and enabling efficient parametric scanning. The proposed method is experimentally validated using both small-scale and large-scale MSDs. The results show that the cylindrical-spherical-cap structure provides better field uniformity than a conventional rectangular shielding configuration within the selected central measurement region, and that the proposed model can reproduce the internal magnetic-field distribution with reasonable accuracy. The proposed method provides a practical tool for rapid performance estimation and preliminary design optimization of MSDs over a wide range of scales.
- 9 June 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (26)
Parametric modeling and neural-network-based prediction of cylindrical-spherical-cap magnetic shielding devices
This paper presents a rapid parametric modeling and prediction framework for cylindrical-spherical-cap magnetic shielding devices (MSDs), in which BPNN-predicted effective permeability is combined with shell-element simulation to enable efficient performance estimation and provide guidance for preliminary engineering design in precision measurement environments. The parameters of the Jiles-Atherton model are identified from measured hysteresis loops of permalloy, and the resulting anhysteretic magnetization curve is used to construct the material constitutive relation for finite element analysis. Based on shell-element simulations, the effects of structural parameters on the effective average permeability are investigated. A neural-network model is further developed to establish a rapid mapping between geometric parameters and effective permeability, thereby reducing the computational cost of direct full-thickness nonlinear simulations and enabling efficient parametric scanning. The proposed method is experimentally validated using both small-scale and large-scale MSDs. The results show that the cylindrical-spherical-cap structure provides better field uniformity than a conventional rectangular shielding configuration within the selected central measurement region, and that the proposed model can reproduce the internal magnetic-field distribution with reasonable accuracy. The proposed method provides a practical tool for rapid performance estimation and preliminary design optimization of MSDs over a wide range of scales.
- 20 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
Design of Uniform Magnetic Field Coil for Miniaturized Atomic Sensors Considering the Thermal Effect
This article proposes a design method based on a multi-objective optimization strategy considering the thermal effect for uniform magnetic field coil (UMFC), which is used to provide working magnetic fields for miniaturized atomic sensors and compensate for stray magnetic fields generated by environment and interior components of sensor. With the volume reduction of atomic sensors, the uniformity and thermal effects of UMFC will decrease and increase, respectively, which is detrimental to the performance of the sensor. Therefore, to improve the magnetic field uniformity of UMFC and reduce heat generation, an optimized target field method combining nondominated sorting genetic algorithm III (NSGA-III) is proposed, in which the uniformity error function and thermal power function of the UMFC is taken as design objectives. The experimental results show that the uniformity and temperature of the coil designed by the proposed method are 0.0432% and 316.5 K, respectively, which are of high performance and meet the operation requirement the atomic sensor.
- 20 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
Design of Uniform Magnetic Field Coil for Miniaturized Atomic Sensors Considering the Thermal Effect
This article proposes a design method based on a multi-objective optimization strategy considering the thermal effect for uniform magnetic field coil (UMFC), which is used to provide working magnetic fields for miniaturized atomic sensors and compensate for stray magnetic fields generated by environment and interior components of sensor. With the volume reduction of atomic sensors, the uniformity and thermal effects of UMFC will decrease and increase, respectively, which is detrimental to the performance of the sensor. Therefore, to improve the magnetic field uniformity of UMFC and reduce heat generation, an optimized target field method combining nondominated sorting genetic algorithm III (NSGA-III) is proposed, in which the uniformity error function and thermal power function of the UMFC is taken as design objectives. The experimental results show that the uniformity and temperature of the coil designed by the proposed method are 0.0432% and 316.5 K, respectively, which are of high performance and meet the operation requirement the atomic sensor.
- 20 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Research on the Design of Nonuniform Field Coils With Ferromagnetic Coupling in Magnetically Shielded Cylinder for Magnetocardiogram
To reduce the influence of remanence and interference on magnetocardiogram (MCG) measurements, an approach to designing nonuniform field coils (NUFCs) considering ferromagnetic coupling effects is proposed. First, a magnetic field analytical model considering the coupling effects between the magnetically shielded cylinder (MSC) and coils is established based on the distribution of the magnetic vector potential combined with the image method (IM). Subsequently, using the target field method (TFM), the NUFCs are designed inversely according to the distribution of remanence and interference, by which the problem that existing uniform field coils (UFCs) are difficult to compensate for nonuniform magnetic fields is solved. Furthermore, to improve the performance of the NUFCs, the adaptive inertia weight particle swarm optimization (PSO) method is introduced for optimizing the regularization parameters. Finally, finite-element simulations and experiments are carried out to verify the proposed method. The results from the experiments demonstrate that the remanence within the measurement area is reduced from 60 to below 10 nT by designed NUFCs, while magnetic field interference is effectively suppressed from 37 to 11 pT. These results prove the effectiveness of the designed NUFCs in enhancing the magnetic field performance of MCG devices.
- 20 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Research on the Design of Nonuniform Field Coils With Ferromagnetic Coupling in Magnetically Shielded Cylinder for Magnetocardiogram
To reduce the influence of remanence and interference on magnetocardiogram (MCG) measurements, an approach to designing nonuniform field coils (NUFCs) considering ferromagnetic coupling effects is proposed. First, a magnetic field analytical model considering the coupling effects between the magnetically shielded cylinder (MSC) and coils is established based on the distribution of the magnetic vector potential combined with the image method (IM). Subsequently, using the target field method (TFM), the NUFCs are designed inversely according to the distribution of remanence and interference, by which the problem that existing uniform field coils (UFCs) are difficult to compensate for nonuniform magnetic fields is solved. Furthermore, to improve the performance of the NUFCs, the adaptive inertia weight particle swarm optimization (PSO) method is introduced for optimizing the regularization parameters. Finally, finite-element simulations and experiments are carried out to verify the proposed method. The results from the experiments demonstrate that the remanence within the measurement area is reduced from 60 to below 10 nT by designed NUFCs, while magnetic field interference is effectively suppressed from 37 to 11 pT. These results prove the effectiveness of the designed NUFCs in enhancing the magnetic field performance of MCG devices.
- 4 September 2024
- Published by IOP Publishing in Physica Scripta
- Vol. 99 (10) , 105510
Design of Bi-planar coil to suppress radial magnetic field in magnetically shielded cylinder for magnetocardiography
The high uniformity coils to suppress the static and dynamic magnetic fields along the cardiac magnetic signal are crucial for obtaining high-quality magnetocardiography (MCG) signals. In this paper, the target field method (TFM) combined with the bald eagle search (BES) algorithm is proposed in the design process of the bi-planar coil (BC) to suppress the radial magnetic field (consistent with cardiac magnetic signal) in the magnetically shielded cylinder (MSC). The simulation signifies that the maximum magnetic field deviation of the designed BC is reduced from 2.87% to 0.58% compared with the BC produced by traditional TFM, which illustrates that the proposed method can effectively suppress the radial static magnetic field of the MSC. In addition, automatic field nulling technology was introduced to suppress the dynamic magnetic disturbance. The experiment shows that the maximum magnetic field disturbance was reduced from 5.3 pT to 2.6 pT in the 4 × 4 measurement array. Finally, the cardiac magnetic signal measurement experiment in the MSC proves that the designed BC system is beneficial for high-quality MCG acquisition.
- 4 September 2024
- Published by IOP Publishing in Physica Scripta
- Vol. 99 (10) , 105510
Design of Bi-planar coil to suppress radial magnetic field in magnetically shielded cylinder for magnetocardiography
The high uniformity coils to suppress the static and dynamic magnetic fields along the cardiac magnetic signal are crucial for obtaining high-quality magnetocardiography (MCG) signals. In this paper, the target field method (TFM) combined with the bald eagle search (BES) algorithm is proposed in the design process of the bi-planar coil (BC) to suppress the radial magnetic field (consistent with cardiac magnetic signal) in the magnetically shielded cylinder (MSC). The simulation signifies that the maximum magnetic field deviation of the designed BC is reduced from 2.87% to 0.58% compared with the BC produced by traditional TFM, which illustrates that the proposed method can effectively suppress the radial static magnetic field of the MSC. In addition, automatic field nulling technology was introduced to suppress the dynamic magnetic disturbance. The experiment shows that the maximum magnetic field disturbance was reduced from 5.3 pT to 2.6 pT in the 4 × 4 measurement array. Finally, the cardiac magnetic signal measurement experiment in the MSC proves that the designed BC system is beneficial for high-quality MCG acquisition.
- 28 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Optimal Design for Electric Heating Coil in Atomic Sensors
This paper proposes a novel approach to optimize the heating coil of atomic sensors, which can reduce the impact of heating process on performance. The atomic sensors utilize vapor cells to measure physical quantities by monitoring the precession state of alkali metal atoms, which are influenced by the magnetic field. Achieving a sufficient signal strength requires a high temperature to achieve the desired alkali metal atom density. However, the commonly used electric heating method introduces magnetic interference from the heating current. Therefore, this paper proposes an optimal design scheme in three-dimensional space to mitigate the magnetic field generated by the heating coil in the atomic sensors. By designing vertical and planar structures, the influence of the magnetic field generated during the heating process on alkali metal atoms can be significantly decreased. Firstly, the number of layers in the vertical structure is designed, and a three-layer optimal solution is proposed. Secondly, the planar structure optimization is designed by using the sparrow search algorithm to generate a minimum spatial magnetic field by the heating coil with the same length. The simulation results show that the proposed design coil reduces the magnetic field from 803.44 pT/mA to 160.72 pT/mA at a distance of 2 mm from the coil, a significant improvement over the 2 N configuration. Experimental results confirm that the magnetic field generated by the three-layer vertical structure is smaller than that of other multilayer structure, and the magnetic field generated by the optimized coil is smaller than 2 N coil.
- 28 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Optimal Design for Electric Heating Coil in Atomic Sensors
This paper proposes a novel approach to optimize the heating coil of atomic sensors, which can reduce the impact of heating process on performance. The atomic sensors utilize vapor cells to measure physical quantities by monitoring the precession state of alkali metal atoms, which are influenced by the magnetic field. Achieving a sufficient signal strength requires a high temperature to achieve the desired alkali metal atom density. However, the commonly used electric heating method introduces magnetic interference from the heating current. Therefore, this paper proposes an optimal design scheme in three-dimensional space to mitigate the magnetic field generated by the heating coil in the atomic sensors. By designing vertical and planar structures, the influence of the magnetic field generated during the heating process on alkali metal atoms can be significantly decreased. Firstly, the number of layers in the vertical structure is designed, and a three-layer optimal solution is proposed. Secondly, the planar structure optimization is designed by using the sparrow search algorithm to generate a minimum spatial magnetic field by the heating coil with the same length. The simulation results show that the proposed design coil reduces the magnetic field from 803.44 pT/mA to 160.72 pT/mA at a distance of 2 mm from the coil, a significant improvement over the 2 N configuration. Experimental results confirm that the magnetic field generated by the three-layer vertical structure is smaller than that of other multilayer structure, and the magnetic field generated by the optimized coil is smaller than 2 N coil.