Mickael Eterpi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Mickael Eterpi has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Eric Schmitt
IMV Technologies, Saint Ouen sur Iton, France
1 shared publication- Gerald McDonnell
Gerald McDonnell, BSc, PhD, is a senior director in Microbiological Quality & Sterility Assurance at Johnson & Johnson in Raritan, NJ
1 shared publication Isabelle Couty
CNRS, IFCE, INRAE, Université de Tours, PRC, Nouzilly, France
1 shared publicationLucie Gavin-Plagne
IMV Technologies, Saint Ouen sur Iton, France
1 shared publicationMichele Magistrini
INRAE, PAO, Nouzilly, France
1 shared publicationOlivier Carion
IMV Technologies, Saint Ouen sur Iton, France
1 shared publication
Latest Publications
- 1 January 2022
- Published by Elsevier in Journal of Equine Veterinary Science
- Vol. 108, 103801
INRA96 Supplemented With Phospholipids Liposomes, A Promising Approach for Stallion Sperm Chilling
- 1 January 2022
- Published by Elsevier in Journal of Equine Veterinary Science
- Vol. 108, 103801
INRA96 Supplemented With Phospholipids Liposomes, A Promising Approach for Stallion Sperm Chilling
- 30 December 2010
- Published by Oxford University Press (OUP) in Letters in Applied Microbiology
- Vol. 52 (2) , 150-155
Decontamination efficacy against Mycoplasma
Mycoplasma is minute bacteria that can be found ubiquitously in the environment and also in human, animal and plant tissues. In addition to their public health importance as aetiological agents of infections and possible association with certain cancers, mycoplasma is a major contamination concern in biotechnology. These bacterial cells are very small, can form biofilms and survive for extended periods of time when dried onto surfaces. Despite these concerns, there is little information concerning their resistance to currently used disinfection methods. The objective of this study was to evaluate commonly used biocidal treatments against three representative mycoplasma species. Mycoplasma was dried onto stainless steel coupons and exposed to decontamination products. All strains survived drying and any significant viability loss because of the test method (including neutralization), as demonstrated by a ≤0·5 log(10) for each tested species. The quaternary ammonium compound (QAC) tested presented poor efficacy, whereas 70% ethanol was fully efficient with complete inactivation after 5-min exposure. Alkaline cleaner formulations presented increasing efficacy when tested at 0·2, 0·4 and 0·8% concentrations, with complete kill observed at 0·8% of two products tested. Decontamination with vaporized (gaseous) hydrogen peroxide (VHP) was very efficient at concentrations used for room and small enclosures decontamination (180-1200 ppm with various time exposures), as well as for device sterilization applications. Ethanol and alkaline detergent formulations were particularly efficient against mycoplasma, but a QAC formulation was not. VHP in room disinfection and device sterilization applications was effective against all mycoplasma species tested. Mycoplasma can provide resistance to environmental factors (such as drying) and disinfectants. Further studies are required to confirm the effectiveness of other disinfectants and the mechanisms of mycoplasma resistance.
- 30 December 2010
- Published by Oxford University Press (OUP) in Letters in Applied Microbiology
- Vol. 52 (2) , 150-155
Decontamination efficacy against Mycoplasma
Mycoplasma is minute bacteria that can be found ubiquitously in the environment and also in human, animal and plant tissues. In addition to their public health importance as aetiological agents of infections and possible association with certain cancers, mycoplasma is a major contamination concern in biotechnology. These bacterial cells are very small, can form biofilms and survive for extended periods of time when dried onto surfaces. Despite these concerns, there is little information concerning their resistance to currently used disinfection methods. The objective of this study was to evaluate commonly used biocidal treatments against three representative mycoplasma species. Mycoplasma was dried onto stainless steel coupons and exposed to decontamination products. All strains survived drying and any significant viability loss because of the test method (including neutralization), as demonstrated by a ≤0·5 log(10) for each tested species. The quaternary ammonium compound (QAC) tested presented poor efficacy, whereas 70% ethanol was fully efficient with complete inactivation after 5-min exposure. Alkaline cleaner formulations presented increasing efficacy when tested at 0·2, 0·4 and 0·8% concentrations, with complete kill observed at 0·8% of two products tested. Decontamination with vaporized (gaseous) hydrogen peroxide (VHP) was very efficient at concentrations used for room and small enclosures decontamination (180-1200 ppm with various time exposures), as well as for device sterilization applications. Ethanol and alkaline detergent formulations were particularly efficient against mycoplasma, but a QAC formulation was not. VHP in room disinfection and device sterilization applications was effective against all mycoplasma species tested. Mycoplasma can provide resistance to environmental factors (such as drying) and disinfectants. Further studies are required to confirm the effectiveness of other disinfectants and the mechanisms of mycoplasma resistance.