Justin E. Ngaile
Research Subjects
Justin E. Ngaile has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
A M Jusabani
Department of Radiology, The Agha Khan Hospital, P O Box 2289 Dar es Salaam, Tanzania
1 shared publicationAlex Muhulo
Tanzania Atomic Energy Commission , Block J, Njiro, 23114 Arusha , Tanzania
1 shared publication- Ally I. Ally1 shared publication
- Aloyce Isaya Amasi
Nelson Mandela African Institution of Science and Technology (NM-AIST), School for Materials, Energy, Water, Environmental Science and Engineering, Arusha P.O. Box 447, Tanzania
1 shared publication Assad Amirali
Aga Khan Medical Centre , Baraka Obama Drive, 11101 Dar es Salaam , Tanzania
1 shared publicationAtumaini Makoba
Tanzania Atomic Energy Commission , Block J, Njiro, 23114 Arusha , Tanzania
1 shared publication
Latest Publications
- Open Access
- 13 August 2026
- Published by Elsevier in Journal of Radiation Research and Applied Sciences
- Vol. 19 (3)
Evaluation of occupational radiation exposure during pre- and post-treatment procedures in high-dose-rate intracavitary brachytherapy: A comparative study at two Tanzanian cancer centres
- 13 August 2026
- Published by Elsevier in Journal of Radiation Research and Applied Sciences
- Vol. 19 (3)
Open AccessEvaluation of occupational radiation exposure during pre- and post-treatment procedures in high-dose-rate intracavitary brachytherapy: A comparative study at two Tanzanian cancer centres
- 9 January 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (4) , 409-416
Radiation dose to breast during digital mammography in Tanzania
The aim of this study was to evaluate the mean glandular dose (MGD), to assess the potential for optimization, and to propose diagnostic reference levels (DRLs). MGD was estimated from air kerma measurements and patient information collected during mammography examinations. The 75th percentile values were determined as the third quartile of the median MGD values for all hospitals, and DRLs set as 75th percentile of MGD values. The estimated median values of MGD ranged from 1.5 to 3.9 mGy for craniocaudal projection for median range of 15–59 mm compressed breast thickness (CBT). For a CBT range of 15–63 mm, the median MGD value was 1.5–5.1 mGy for medio-lateral oblique projection. Comparison with other studies showed that the MGD values obtained in this study were relatively high. The magnitude and wide variation of the exposure parameters suggest existing potential for optimization. The training of radiology staff was identified as a top priority.
- 9 January 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (4) , 409-416
Radiation dose to breast during digital mammography in Tanzania
The aim of this study was to evaluate the mean glandular dose (MGD), to assess the potential for optimization, and to propose diagnostic reference levels (DRLs). MGD was estimated from air kerma measurements and patient information collected during mammography examinations. The 75th percentile values were determined as the third quartile of the median MGD values for all hospitals, and DRLs set as 75th percentile of MGD values. The estimated median values of MGD ranged from 1.5 to 3.9 mGy for craniocaudal projection for median range of 15–59 mm compressed breast thickness (CBT). For a CBT range of 15–63 mm, the median MGD value was 1.5–5.1 mGy for medio-lateral oblique projection. Comparison with other studies showed that the MGD values obtained in this study were relatively high. The magnitude and wide variation of the exposure parameters suggest existing potential for optimization. The training of radiology staff was identified as a top priority.
- 3 November 2021
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 197 (2) , 63-77
ESTIMATION OF PATIENT RADIATION DOSES FROM MULTI-DETECTOR COMPUTED TOMOGRAPHY ANGIOGRAPHY PROCEDURES IN TANZANIA
The aim of the present study was to estimate the volume CT dose index (CTDIvol), dose length product (DLP) and effective dose (ED) to patients from five multi-detector computed tomography angiography (MDCTA) procedures: brain, carotid, coronary, entire aorta and lower limb from four medical institutions in Tanzania; to compare these doses to those reported in the literature, and to compare the data obtained with ICRP 103 and Monte Carlo software. The radiation doses for 217 patients were estimated using patient demographics, patient-related exposure parameters, the geometry of examination and CT-Expo V 2.4 Monte Carlo-based software. The median values of the CTDIvol, DLP and ED for MDCTA procedures of the brain and carotids were 36.8 mGy, 1481.0 mGy∙cm and 5.2 mSv, and 15.9 mGy, 1224.0 mGy∙cm and 7.8 mSv, respectively; while for the coronary, entire aortic, and lower limbs were 49.4 mGy, 1493.0 mGy∙cm and 30.6 mSv; 16.2 mGy, 2287.0 mGy∙cm and 41.1 mSv; and 6.4 mGy, 1406.0 mGy∙cm and 10.5 mSv, respectively. The ratio of the maximum to minimum ED values to individual patients across the four medical centers were 41.4, 11.1, 4.6, 9.5 and 37.4, respectively, for the brain, carotid, coronary, entire aortic and lower limb CT angiography procedures. The mean values of CTDIvol, DLP and ED in the present study were typically higher than the values reported from Kenya, Korea and Saudi Arabia. The 75th percentile values of the DLP were above the preliminary diagnostic references levels proposed by Kenya, Switzerland and Korea. The observed wide range of examination scanning protocols and patient doses for similar MDCTA procedures within and across hospitals; and the observed relatively high patient doses compared to those reported in the literature, call for the need to standardize scanning protocols and optimise patient dose from MDCTA procedures.
- 3 November 2021
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 197 (2) , 63-77
ESTIMATION OF PATIENT RADIATION DOSES FROM MULTI-DETECTOR COMPUTED TOMOGRAPHY ANGIOGRAPHY PROCEDURES IN TANZANIA
The aim of the present study was to estimate the volume CT dose index (CTDIvol), dose length product (DLP) and effective dose (ED) to patients from five multi-detector computed tomography angiography (MDCTA) procedures: brain, carotid, coronary, entire aorta and lower limb from four medical institutions in Tanzania; to compare these doses to those reported in the literature, and to compare the data obtained with ICRP 103 and Monte Carlo software. The radiation doses for 217 patients were estimated using patient demographics, patient-related exposure parameters, the geometry of examination and CT-Expo V 2.4 Monte Carlo-based software. The median values of the CTDIvol, DLP and ED for MDCTA procedures of the brain and carotids were 36.8 mGy, 1481.0 mGy∙cm and 5.2 mSv, and 15.9 mGy, 1224.0 mGy∙cm and 7.8 mSv, respectively; while for the coronary, entire aortic, and lower limbs were 49.4 mGy, 1493.0 mGy∙cm and 30.6 mSv; 16.2 mGy, 2287.0 mGy∙cm and 41.1 mSv; and 6.4 mGy, 1406.0 mGy∙cm and 10.5 mSv, respectively. The ratio of the maximum to minimum ED values to individual patients across the four medical centers were 41.4, 11.1, 4.6, 9.5 and 37.4, respectively, for the brain, carotid, coronary, entire aortic and lower limb CT angiography procedures. The mean values of CTDIvol, DLP and ED in the present study were typically higher than the values reported from Kenya, Korea and Saudi Arabia. The 75th percentile values of the DLP were above the preliminary diagnostic references levels proposed by Kenya, Switzerland and Korea. The observed wide range of examination scanning protocols and patient doses for similar MDCTA procedures within and across hospitals; and the observed relatively high patient doses compared to those reported in the literature, call for the need to standardize scanning protocols and optimise patient dose from MDCTA procedures.