JNJustin E. Ngaile

Justin E. Ngaile

*This is an algorithmically generated author record based on publicly available information.

Justin E. Ngaile has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Radiation dose to breast during digital mammography in Tanzania

    by Elisha Edmund, Mary Kamuzora, Wilbroad Muhogora, Patrick Ngoya, Alex Muhulo, Assad Amirali, Atumaini Makoba, Wilson Ngoye, Justin Ngaile, Salma Majatta, et al.

    The aim of this study was to evaluate the mean glandular dose (MGD), to assess the potential for optimization, and to propose diagnostic reference levels (DRLs). MGD was estimated from air kerma measurements and patient information collected during mammography examinations. The 75th percentile values were determined as the third quartile of the median MGD values for all hospitals, and DRLs set as 75th percentile of MGD values. The estimated median values of MGD ranged from 1.5 to 3.9 mGy for craniocaudal projection for median range of 15–59 mm compressed breast thickness (CBT). For a CBT range of 15–63 mm, the median MGD value was 1.5–5.1 mGy for medio-lateral oblique projection. Comparison with other studies showed that the MGD values obtained in this study were relatively high. The magnitude and wide variation of the exposure parameters suggest existing potential for optimization. The training of radiology staff was identified as a top priority.


  • ESTIMATION OF PATIENT RADIATION DOSES FROM MULTI-DETECTOR COMPUTED TOMOGRAPHY ANGIOGRAPHY PROCEDURES IN TANZANIA

    by J E Ngaile, P K Msaki, S A Suleiman, F M Chuma, W E Muhogora, A M Jusabani

    The aim of the present study was to estimate the volume CT dose index (CTDIvol), dose length product (DLP) and effective dose (ED) to patients from five multi-detector computed tomography angiography (MDCTA) procedures: brain, carotid, coronary, entire aorta and lower limb from four medical institutions in Tanzania; to compare these doses to those reported in the literature, and to compare the data obtained with ICRP 103 and Monte Carlo software. The radiation doses for 217 patients were estimated using patient demographics, patient-related exposure parameters, the geometry of examination and CT-Expo V 2.4 Monte Carlo-based software. The median values of the CTDIvol, DLP and ED for MDCTA procedures of the brain and carotids were 36.8 mGy, 1481.0 mGy∙cm and 5.2 mSv, and 15.9 mGy, 1224.0 mGy∙cm and 7.8 mSv, respectively; while for the coronary, entire aortic, and lower limbs were 49.4 mGy, 1493.0 mGy∙cm and 30.6 mSv; 16.2 mGy, 2287.0 mGy∙cm and 41.1 mSv; and 6.4 mGy, 1406.0 mGy∙cm and 10.5 mSv, respectively. The ratio of the maximum to minimum ED values to individual patients across the four medical centers were 41.4, 11.1, 4.6, 9.5 and 37.4, respectively, for the brain, carotid, coronary, entire aortic and lower limb CT angiography procedures. The mean values of CTDIvol, DLP and ED in the present study were typically higher than the values reported from Kenya, Korea and Saudi Arabia. The 75th percentile values of the DLP were above the preliminary diagnostic references levels proposed by Kenya, Switzerland and Korea. The observed wide range of examination scanning protocols and patient doses for similar MDCTA procedures within and across hospitals; and the observed relatively high patient doses compared to those reported in the literature, call for the need to standardize scanning protocols and optimise patient dose from MDCTA procedures.