Yanliang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yanliang Li has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Jianming Peng
College of Construction Engineering, Jilin University, Changchun 130026, China
2 shared publications - Chao Guo
No. 240 Research Institute of Nuclear, CNNC, Shenyang 110141, China
1 shared publication - Chaoyang Huang
College of Construction Engineering, Jilin University, Changchun 130026, China
1 shared publication - Dong Ge
Jilin University College of Construction Engineering Changchun 130026 , China
1 shared publication - Jiming Li
College of Construction Engineering, Jilin University, Changchun 130026, China
1 shared publication - Kun Bo
State Key Laboratory of Deep Earth Exploration and Imaging, College of Construction Engineering, Jilin University, Changchun 130026, China
1 shared publication
Latest Publications
- 17 January 2023
- Published by Wiley in Journal of Applied Mechanics
- Vol. 90 (5) , 1-24
Mechanical Response of Stress Wave Attenuator With Layered Structure Under Impact Load: Experimental and Numerical Studies
The fluidic down-the-hole (DTH) hammer drilling is generally regarded as one of the best means for hot dry rock (HDR) drilling. The fluid oscillator, as the core part of the fluidic DTH hammer, is prone to fracture when subjected to impact loads due to its brittle characteristics. Therefore, a steel-layered structure with different contact areas is developed as a stress wave attenuator to protect the fluid oscillator for the DTH hammer under high-temperature drilling conditions. In this paper, the stress wave attenuation performance with different steel-layered structures is analyzed based on the split Hopkinson pressure bar (SHPB) technique. The effects of contact area ratio, the orientation of contact surfaces, and number of layers on the stress wave attenuation are investigated by numerical simulations and laboratory tests. It is found that the attenuation ratios in stress amplitude and impact energy gradually increased with the increase of the contact area ratio. Besides, the orientation of contact surfaces has a significant influence on the attenuation effect. For the layered structure with a two-layer object part, the maximum attenuation ratios of stress amplitude and impact energy are 62.4% and 79.6%, respectively, when the included angle between the two convex structures is increased to 90 deg. Additionally, the attenuation ratio of the layered structure can be improved by increasing the number of layers. The results demonstrate that the stress wave attenuator with layered structures has great potential for brittle materials protection against impact loads.
- 17 January 2023
- Published by Wiley in Journal of Applied Mechanics
- Vol. 90 (5) , 1-24
Mechanical Response of Stress Wave Attenuator With Layered Structure Under Impact Load: Experimental and Numerical Studies
The fluidic down-the-hole (DTH) hammer drilling is generally regarded as one of the best means for hot dry rock (HDR) drilling. The fluid oscillator, as the core part of the fluidic DTH hammer, is prone to fracture when subjected to impact loads due to its brittle characteristics. Therefore, a steel-layered structure with different contact areas is developed as a stress wave attenuator to protect the fluid oscillator for the DTH hammer under high-temperature drilling conditions. In this paper, the stress wave attenuation performance with different steel-layered structures is analyzed based on the split Hopkinson pressure bar (SHPB) technique. The effects of contact area ratio, the orientation of contact surfaces, and number of layers on the stress wave attenuation are investigated by numerical simulations and laboratory tests. It is found that the attenuation ratios in stress amplitude and impact energy gradually increased with the increase of the contact area ratio. Besides, the orientation of contact surfaces has a significant influence on the attenuation effect. For the layered structure with a two-layer object part, the maximum attenuation ratios of stress amplitude and impact energy are 62.4% and 79.6%, respectively, when the included angle between the two convex structures is increased to 90 deg. Additionally, the attenuation ratio of the layered structure can be improved by increasing the number of layers. The results demonstrate that the stress wave attenuator with layered structures has great potential for brittle materials protection against impact loads.
- Open Access
Experimental Study on the Insulation Layer Thickness of a Novel Ice Coring Device in Loose Sandstone-Type Uranium Deposits
The target strata of sandstone-type uranium deposits are usually located in the fragile and loose strata, which makes it difficult to obtain core samples; consequently, a novel ice coring device for loose sandstone-type uranium deposits is proposed to solve this problem. Experiments proved that the artificial sample can replace the natural sample, and the coring method has high reliability. Ensuring the allegro formation of an ice valve with a given cold source is critical for this coring system, and reducing the loss of cold energy with help of insulation layer is one of the methods to speed up the formation of ice valve. Since the diameter of the drill tool is limited by its working scenario, the thickness of insulation layer is limited to ensure the size of core. Therefore, this paper conducted laboratory experiments of the insulation layer with different thicknesses to study the effect of the insulation layer on the formation of the sand–ice valve. Results show that the insulation layer can reduce the loss of cold energy during the freezing process and significantly affect the formation time of the sand–ice valve. When the thickness of the aerogel insulation layer is 2 mm, the freezing time is 44% shorter than that without insulation layer. According to the tests, the novel ice coring device is expected to solve the coring problem in loose sandstone-type uranium deposits.
Open AccessExperimental Study on the Insulation Layer Thickness of a Novel Ice Coring Device in Loose Sandstone-Type Uranium Deposits
The target strata of sandstone-type uranium deposits are usually located in the fragile and loose strata, which makes it difficult to obtain core samples; consequently, a novel ice coring device for loose sandstone-type uranium deposits is proposed to solve this problem. Experiments proved that the artificial sample can replace the natural sample, and the coring method has high reliability. Ensuring the allegro formation of an ice valve with a given cold source is critical for this coring system, and reducing the loss of cold energy with help of insulation layer is one of the methods to speed up the formation of ice valve. Since the diameter of the drill tool is limited by its working scenario, the thickness of insulation layer is limited to ensure the size of core. Therefore, this paper conducted laboratory experiments of the insulation layer with different thicknesses to study the effect of the insulation layer on the formation of the sand–ice valve. Results show that the insulation layer can reduce the loss of cold energy during the freezing process and significantly affect the formation time of the sand–ice valve. When the thickness of the aerogel insulation layer is 2 mm, the freezing time is 44% shorter than that without insulation layer. According to the tests, the novel ice coring device is expected to solve the coring problem in loose sandstone-type uranium deposits.