Franziska M. Esmek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Franziska M. Esmek has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Irene Fernandez-Cuesta
Universität Hamburg
2 shared publications Irene Fernandez‐Cuesta
University of Hamburg Hamburg Centre for Ultrafast Imaging Luruper Chaussee 149 22671 Hamburg Germany
1 shared publicationJeremy P Teuber
Universität Hamburg, Institute of Nanostructure and Solid State Physics, HARBOR Bldg 610, Luruper Chaussee 149, Hamburg D-22761, Germany
1 shared publication- Louise von Lacroix
Institute for Nanostructure and Solid State Physics, Building 610 HARBOR, University Hamburg, Hamburg 22761, Germany
1 shared publication - Lucjan Grzegorzewski
Institute of Nanostructure and Solid State Physics, Universität Hamburg, HARBOR Bldg 610, Luruper Chaussee 149, 22761 Hamburg, Germany
1 shared publication Nathalie P Pranzner
Universität Hamburg, Institute of Nanostructure and Solid State Physics, HARBOR Bldg 610, Luruper Chaussee 149, Hamburg D-22761, Germany
1 shared publication
Latest Publications
- Open Access
- 12 June 2026
- Published by MDPI AG in Nanomaterials
- Vol. 16 (12) , 732
A Lab-on-a-Chip for the Extraction and Analysis of Single Molecules of DNA from Biological Media
DNA extraction is a critical prerequisite for reliable downstream analyses such as Polymerase Chain Reaction (PCR), sequencing, and genotyping. Conventional methods often require labor-intensive protocols, large sample volumes, or costly automation. Microfluidic approaches offer an alternative by reducing reagent consumption and enabling faster, more integrated workflows. Here, we present a passive lab-on-a-chip device that performs DNA extraction from complex biological media and enables subsequent on-chip single-molecule analysis. The chip integrates a magnetophoresis-based solid-phase extraction module with a fluorescence detection section capable of quantifying DNA molecules in microchannels and visualizing stretched molecules in nanochannels. The multi-level micro/nanofluidic architecture is fabricated in polymer using a single-step nanoimprinting process with a total manufacturing time of two minutes per chip, enabling scalable production. As a proof of concept, the device extracted DNA from samples spiked into buffer or plasma. On-chip transfer efficiency of DNA–bead complexes to the elution buffer reached 86%, and quantitative analysis of the recovered liquid showed an overall extraction efficiency of 40% (including DNA recovery off-chip), with intact 48 kbp DNA confirmed in both micro- and nanochannel measurements. This platform offers a promising foundation for point-of-care and point-of-interest applications, where integrated DNA extraction and analysis can reduce sample loss and support streamlined, automated workflows.
- 12 June 2026
- Published by MDPI AG in Nanomaterials
- Vol. 16 (12) , 732
Open AccessA Lab-on-a-Chip for the Extraction and Analysis of Single Molecules of DNA from Biological Media
DNA extraction is a critical prerequisite for reliable downstream analyses such as Polymerase Chain Reaction (PCR), sequencing, and genotyping. Conventional methods often require labor-intensive protocols, large sample volumes, or costly automation. Microfluidic approaches offer an alternative by reducing reagent consumption and enabling faster, more integrated workflows. Here, we present a passive lab-on-a-chip device that performs DNA extraction from complex biological media and enables subsequent on-chip single-molecule analysis. The chip integrates a magnetophoresis-based solid-phase extraction module with a fluorescence detection section capable of quantifying DNA molecules in microchannels and visualizing stretched molecules in nanochannels. The multi-level micro/nanofluidic architecture is fabricated in polymer using a single-step nanoimprinting process with a total manufacturing time of two minutes per chip, enabling scalable production. As a proof of concept, the device extracted DNA from samples spiked into buffer or plasma. On-chip transfer efficiency of DNA–bead complexes to the elution buffer reached 86%, and quantitative analysis of the recovered liquid showed an overall extraction efficiency of 40% (including DNA recovery off-chip), with intact 48 kbp DNA confirmed in both micro- and nanochannel measurements. This platform offers a promising foundation for point-of-care and point-of-interest applications, where integrated DNA extraction and analysis can reduce sample loss and support streamlined, automated workflows.
- 16 March 2024
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 19 (5) , 840-844
Flow Behavior Characterization of DNA Molecules in Passive Nanofluidic Devices†
- 16 March 2024
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 19 (5) , 840-844
Flow Behavior Characterization of DNA Molecules in Passive Nanofluidic Devices†
- 1 July 2022
- Published by IOP Publishing in Nanotechnology
- Vol. 33 (38) , 385301
Pillar-structured 3D inlets fabricated by dose-modulated e-beam lithography and nanoimprinting for DNA analysis in passive, clogging-free, nanofluidic devices
We present the fabrication of three-dimensional inlets with gradually decreasing widths and depths and with nanopillars on the slope, all defined in just one lithography step. In addition, as an application, we show how these micro- and nanostructures can be used for micro- and nanofluidics and lab-on-a-chip devices to facilitate the flow and analyze single molecules of DNA. For the fabrication of 3D inlets in a single layer process, dose-modulated electron beam lithography was used, producing depths between 750 nm and 50 nm along a 30 μm long inlet, which is additionally structured with nanometer-scale pillars randomly distributed on top, as a result of incomplete exposure and underdevelopment of the resist. The fabrication conditions affect the slope of the inlet, the nanopillar density and coverage. The key parameters are the dose used for the electron beam exposure and the development conditions, like the developer’s dilution, stirring and development time. The 3D inlets with nanostructured pillars were integrated into fluidic devices, acting as a transition between micro and nanofluidic structures for pre-stretching and unfolding DNA molecules, avoiding the intrusion of folded molecules and clogging the analysis channel. After patterning these structures in silicon, they can be replicated in polymer by UV nanoimprinting. We show here how the inlets with pillars slow down the molecules before they enter the nanochannels, resulting in a 3-fold decrease in speed, which would translate to an improvement in the resolution for DNA optical mapping.
- 1 July 2022
- Published by IOP Publishing in Nanotechnology
- Vol. 33 (38) , 385301
Pillar-structured 3D inlets fabricated by dose-modulated e-beam lithography and nanoimprinting for DNA analysis in passive, clogging-free, nanofluidic devices
We present the fabrication of three-dimensional inlets with gradually decreasing widths and depths and with nanopillars on the slope, all defined in just one lithography step. In addition, as an application, we show how these micro- and nanostructures can be used for micro- and nanofluidics and lab-on-a-chip devices to facilitate the flow and analyze single molecules of DNA. For the fabrication of 3D inlets in a single layer process, dose-modulated electron beam lithography was used, producing depths between 750 nm and 50 nm along a 30 μm long inlet, which is additionally structured with nanometer-scale pillars randomly distributed on top, as a result of incomplete exposure and underdevelopment of the resist. The fabrication conditions affect the slope of the inlet, the nanopillar density and coverage. The key parameters are the dose used for the electron beam exposure and the development conditions, like the developer’s dilution, stirring and development time. The 3D inlets with nanostructured pillars were integrated into fluidic devices, acting as a transition between micro and nanofluidic structures for pre-stretching and unfolding DNA molecules, avoiding the intrusion of folded molecules and clogging the analysis channel. After patterning these structures in silicon, they can be replicated in polymer by UV nanoimprinting. We show here how the inlets with pillars slow down the molecules before they enter the nanochannels, resulting in a 3-fold decrease in speed, which would translate to an improvement in the resolution for DNA optical mapping.