Louise von Lacroix
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Louise von Lacroix has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Irene Fernandez-Cuesta
Universität Hamburg
3 shared publications Emilia Drescher
Institute for Nanostructure and Solid State Physics, Building 610 HARBOR, University Hamburg, Hamburg 22761, Germany
2 shared publications- Christoph Noack
ZBH – Center for Bioinformatics, University Hamburg, Hamburg 22761, Germany
1 shared publication - Franziska M. Esmek
Institute of Nanostructure and Solid State Physics, Universität Hamburg, HARBOR Bldg 610, Luruper Chaussee 149, 22761 Hamburg, Germany
1 shared publication Herbert Atrian-Garcia
University of Hamburg Building 610, HARBOR
1 shared publication- Lucjan Grzegorzewski
Institute of Nanostructure and Solid State Physics, Universität Hamburg, HARBOR Bldg 610, Luruper Chaussee 149, 22761 Hamburg, Germany
1 shared publication
Latest Publications
- Open Access
- 10 November 2026
- Published by American Chemical Society (ACS) in ACS Applied Engineering Materials
Defect-Free Imprinting of Enclosed Microstructures and Dense Pillar Arrays by Vacuum-Assisted Degassing in Ormocer Resists: Process Optimization and Demonstration for Microfluidic Devices
The direct imprinting of enclosed microstructures such as dense pillar arrays is limited by air entrapment within stamp cavities, which prevents complete filling and leads to defective structure formation. Here, we present a systematic investigation of vacuum-assisted imprinting as a strategy to overcome this limitation, using OrmoStamp working stamps to replicate arrays of micropillars with 20 μm diameter, 27 μm height, and 38 μm pitch into UV curable resists from the Ormocer family. By degassing the stamp-polymer assembly inside a desiccator under controlled vacuum prior to UV curing, air entrapment is effectively eliminated. Three degassing conditions are compareda strong pump, a weak pump, and passive degassing at ambient pressurealongside two curing protocols: ambient-cure and in situ vacuum-pressure. With passive degassing at ambient conditions, we obtain ∼85% of fully imprinted pillars in the array after 60 min. In contrast, with a strong pump, we achieve 100% pillar yield after just 10 min of degassing. The optimized process is demonstrated across three materialsOrmoStamp, Ormocomp, and the fluorine-free OrmoStamp FF. Qualitative evidence suggests that air removal proceeds primarily via bubble migration from the cavities. The practical impact of the optimization is demonstrated through two functional microfluidic applications: a deterministic lateral displacement device for micro-particle separation, and a chip with U-shaped hydrodynamic traps for particle capture, both of which require defect-free microstructures for functional operation.
- 10 November 2026
- Published by American Chemical Society (ACS) in ACS Applied Engineering Materials
Open AccessDefect-Free Imprinting of Enclosed Microstructures and Dense Pillar Arrays by Vacuum-Assisted Degassing in Ormocer Resists: Process Optimization and Demonstration for Microfluidic Devices
The direct imprinting of enclosed microstructures such as dense pillar arrays is limited by air entrapment within stamp cavities, which prevents complete filling and leads to defective structure formation. Here, we present a systematic investigation of vacuum-assisted imprinting as a strategy to overcome this limitation, using OrmoStamp working stamps to replicate arrays of micropillars with 20 μm diameter, 27 μm height, and 38 μm pitch into UV curable resists from the Ormocer family. By degassing the stamp-polymer assembly inside a desiccator under controlled vacuum prior to UV curing, air entrapment is effectively eliminated. Three degassing conditions are compareda strong pump, a weak pump, and passive degassing at ambient pressurealongside two curing protocols: ambient-cure and in situ vacuum-pressure. With passive degassing at ambient conditions, we obtain ∼85% of fully imprinted pillars in the array after 60 min. In contrast, with a strong pump, we achieve 100% pillar yield after just 10 min of degassing. The optimized process is demonstrated across three materialsOrmoStamp, Ormocomp, and the fluorine-free OrmoStamp FF. Qualitative evidence suggests that air removal proceeds primarily via bubble migration from the cavities. The practical impact of the optimization is demonstrated through two functional microfluidic applications: a deterministic lateral displacement device for micro-particle separation, and a chip with U-shaped hydrodynamic traps for particle capture, both of which require defect-free microstructures for functional operation.
- Open Access
- 10 November 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (22) , 5919-5931
Design-dependent shear and liquid media transport characteristics in microfluidic U-shaped cell traps
Cells trapped in microfluidic devices experience shear stress and transport of soluble factors. We provide a tunable framework based on trap design, trap dimensions, and flow rate. Created in BioRender. https://BioRender.com/vpp8bs7.
- 10 November 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (22) , 5919-5931
Open AccessDesign-dependent shear and liquid media transport characteristics in microfluidic U-shaped cell traps
Cells trapped in microfluidic devices experience shear stress and transport of soluble factors. We provide a tunable framework based on trap design, trap dimensions, and flow rate. Created in BioRender. https://BioRender.com/vpp8bs7.
- Open Access
- 12 June 2026
- Published by MDPI AG in Nanomaterials
- Vol. 16 (12) , 732
A Lab-on-a-Chip for the Extraction and Analysis of Single Molecules of DNA from Biological Media
DNA extraction is a critical prerequisite for reliable downstream analyses such as Polymerase Chain Reaction (PCR), sequencing, and genotyping. Conventional methods often require labor-intensive protocols, large sample volumes, or costly automation. Microfluidic approaches offer an alternative by reducing reagent consumption and enabling faster, more integrated workflows. Here, we present a passive lab-on-a-chip device that performs DNA extraction from complex biological media and enables subsequent on-chip single-molecule analysis. The chip integrates a magnetophoresis-based solid-phase extraction module with a fluorescence detection section capable of quantifying DNA molecules in microchannels and visualizing stretched molecules in nanochannels. The multi-level micro/nanofluidic architecture is fabricated in polymer using a single-step nanoimprinting process with a total manufacturing time of two minutes per chip, enabling scalable production. As a proof of concept, the device extracted DNA from samples spiked into buffer or plasma. On-chip transfer efficiency of DNA–bead complexes to the elution buffer reached 86%, and quantitative analysis of the recovered liquid showed an overall extraction efficiency of 40% (including DNA recovery off-chip), with intact 48 kbp DNA confirmed in both micro- and nanochannel measurements. This platform offers a promising foundation for point-of-care and point-of-interest applications, where integrated DNA extraction and analysis can reduce sample loss and support streamlined, automated workflows.
- 12 June 2026
- Published by MDPI AG in Nanomaterials
- Vol. 16 (12) , 732
Open AccessA Lab-on-a-Chip for the Extraction and Analysis of Single Molecules of DNA from Biological Media
DNA extraction is a critical prerequisite for reliable downstream analyses such as Polymerase Chain Reaction (PCR), sequencing, and genotyping. Conventional methods often require labor-intensive protocols, large sample volumes, or costly automation. Microfluidic approaches offer an alternative by reducing reagent consumption and enabling faster, more integrated workflows. Here, we present a passive lab-on-a-chip device that performs DNA extraction from complex biological media and enables subsequent on-chip single-molecule analysis. The chip integrates a magnetophoresis-based solid-phase extraction module with a fluorescence detection section capable of quantifying DNA molecules in microchannels and visualizing stretched molecules in nanochannels. The multi-level micro/nanofluidic architecture is fabricated in polymer using a single-step nanoimprinting process with a total manufacturing time of two minutes per chip, enabling scalable production. As a proof of concept, the device extracted DNA from samples spiked into buffer or plasma. On-chip transfer efficiency of DNA–bead complexes to the elution buffer reached 86%, and quantitative analysis of the recovered liquid showed an overall extraction efficiency of 40% (including DNA recovery off-chip), with intact 48 kbp DNA confirmed in both micro- and nanochannel measurements. This platform offers a promising foundation for point-of-care and point-of-interest applications, where integrated DNA extraction and analysis can reduce sample loss and support streamlined, automated workflows.