Yiming Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yiming Zhang has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Congcong Zhou
Zhejiang University
3 shared publications - Xuesong Ye
Zhejiang University
3 shared publications - Yuan-Ting Zhang
Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, SAR, China
3 shared publications - Hong Jiang
School of Public Health, National Health Commission Key Laboratory of Health Technology Assessment, Fudan University, Shanghai, China
2 shared publications - Hong Zhou
College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou 310027, China
2 shared publications - Ting Xiang
Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, SAR, China
2 shared publications
Latest Publications
- Open Access
- 12 August 2026
- Published by Association for Computing Machinery (ACM) in ACM Computing Surveys
Reinforcement Learning for Multimodal Foundation Models: A Survey
Recent advances at the intersection of reinforcement learning (RL) and Multimodal Foundation Models have enabled agents that not only perceive complex visual scenes but also reason, generate, and act within them. This survey offers a critical and up-to-date synthesis of the field. We first formalize visual RL problems and trace the evolution of policy-optimization strategies from RLHF to verifiable reward paradigms, and from Proximal Policy Optimization to Group Relative Policy Optimization. We then organize more than 200 representative works into four thematic pillars: multi-modal large language models, visual generation, unified model frameworks, and vision-language-action models. For each pillar we examine algorithmic design, reward engineering, benchmark progress, and we distill trends such as curriculum-driven training, preference-aligned diffusion, and unified reward modeling. Finally, we review evaluation protocols spanning policy-level, trajectory-level preference, and training diagnostic stability, and we identify open challenges that include sample efficiency, generalization, and safe deployment. Our goal is to provide researchers and practitioners with a coherent map of the rapidly expanding landscape of visual RL and to highlight promising directions for future inquiry. Resources are available at: https://github.com/weijiawu/Awesome-RL-for-Multimodal-Foundation-Models.
- 12 August 2026
- Published by Association for Computing Machinery (ACM) in ACM Computing Surveys
Open AccessReinforcement Learning for Multimodal Foundation Models: A Survey
Recent advances at the intersection of reinforcement learning (RL) and Multimodal Foundation Models have enabled agents that not only perceive complex visual scenes but also reason, generate, and act within them. This survey offers a critical and up-to-date synthesis of the field. We first formalize visual RL problems and trace the evolution of policy-optimization strategies from RLHF to verifiable reward paradigms, and from Proximal Policy Optimization to Group Relative Policy Optimization. We then organize more than 200 representative works into four thematic pillars: multi-modal large language models, visual generation, unified model frameworks, and vision-language-action models. For each pillar we examine algorithmic design, reward engineering, benchmark progress, and we distill trends such as curriculum-driven training, preference-aligned diffusion, and unified reward modeling. Finally, we review evaluation protocols spanning policy-level, trajectory-level preference, and training diagnostic stability, and we identify open challenges that include sample efficiency, generalization, and safe deployment. Our goal is to provide researchers and practitioners with a coherent map of the rapidly expanding landscape of visual RL and to highlight promising directions for future inquiry. Resources are available at: https://github.com/weijiawu/Awesome-RL-for-Multimodal-Foundation-Models.
- Open Access
- 15 June 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (2) , 1-28
PPG-Sport: A Dataset for Reliable Heart Rate Monitoring from Wrist PPG Under Dynamic Sports Conditions
Photoplethysmography (PPG) has become a cornerstone of physiological sensing in wearable devices, enabling non-invasive monitoring of heart rate and related biomarkers. However, its reliability deteriorates sharply under dynamic, high-intensity, or non-periodic motions such as those in sports, where existing datasets fail to capture realistic wrist dynamics. To address this gap, we introduce PPG-Sport, the first large-scale dataset designed for heart rate monitoring from wrist-worn PPG under real sports conditions. The PPG-Sport dataset includes synchronized PPG, inertial measurement unit (IMU), and electrocardiography (ECG) recordings from both wrists of 30 participants across six representative activities: stationary, walking, running, badminton, table tennis, and basketball, amounting to 48 hours of multimodal data. PPG-Sport uniquely captures three critical properties absent in prior datasets: (1) non-periodicity, reflecting irregular and broadband motion patterns; (2) high intensity, with frequent, large-magnitude accelerations; and (3) bilateral asymmetry, caused by distinct functional roles of the dominant and non-dominant hands during sports. We further establish a deep-learning-based benchmark that combines both temporal and spectral representations of PPG and IMU signals to evaluate heart rate estimation performance. Experimental results show that models trained only on conventional periodic activities fail drastically in sports scenarios. Although incorporating sports data mitigates the degradation, significant errors remain. These findings highlight PPG-Sport as an essential and challenging benchmark for developing motion-robust physiological sensing algorithms during sports activities. Dataset and benchmark code are available at: https://github.com/LaserHu/PPG-Sport.
- 15 June 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (2) , 1-28
Open AccessPPG-Sport: A Dataset for Reliable Heart Rate Monitoring from Wrist PPG Under Dynamic Sports Conditions
Photoplethysmography (PPG) has become a cornerstone of physiological sensing in wearable devices, enabling non-invasive monitoring of heart rate and related biomarkers. However, its reliability deteriorates sharply under dynamic, high-intensity, or non-periodic motions such as those in sports, where existing datasets fail to capture realistic wrist dynamics. To address this gap, we introduce PPG-Sport, the first large-scale dataset designed for heart rate monitoring from wrist-worn PPG under real sports conditions. The PPG-Sport dataset includes synchronized PPG, inertial measurement unit (IMU), and electrocardiography (ECG) recordings from both wrists of 30 participants across six representative activities: stationary, walking, running, badminton, table tennis, and basketball, amounting to 48 hours of multimodal data. PPG-Sport uniquely captures three critical properties absent in prior datasets: (1) non-periodicity, reflecting irregular and broadband motion patterns; (2) high intensity, with frequent, large-magnitude accelerations; and (3) bilateral asymmetry, caused by distinct functional roles of the dominant and non-dominant hands during sports. We further establish a deep-learning-based benchmark that combines both temporal and spectral representations of PPG and IMU signals to evaluate heart rate estimation performance. Experimental results show that models trained only on conventional periodic activities fail drastically in sports scenarios. Although incorporating sports data mitigates the degradation, significant errors remain. These findings highlight PPG-Sport as an essential and challenging benchmark for developing motion-robust physiological sensing algorithms during sports activities. Dataset and benchmark code are available at: https://github.com/LaserHu/PPG-Sport.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 30 (1) , 303-314
Multi-Wavelength Photoplethysmographic Assessment of Fingertip Vasculature for Auto-Calibrated Cuffless Blood Pressure Monitoring
Long-term cuffless monitoring of blood pressure (BP) is of immense value in the diagnosis and prevention of cardiovascular diseases (CVD). While there are critical needs for wearable cuffless BP monitoring devices in personalized CVD care and hypertension management, current technologies face challenges in long-term accuracy which limits significantly its clinical applicability. To maintain the accuracy of cuffless blood pressure forecasting, frequent calibration is a vital necessity. However, conventional BP calibration approaches are inherently inconvenient and time-consuming. In this work, we address the challenge by developing a novel auto-calibration system enabling long-term BP estimation. The innovation of this approach combines depth-resolved vascular characteristics extracted from multi-wavelength photoplethysmographic (MWPPG) measurements at fingertip, with an adaptive cross-modal knowledge distillation algorithm for continuous refinement of blood pressure estimation. We have evaluated the system on the CAS-BP database of over a thousand subjects using various calibration strategies. The results have shown that frequent calibration can effectively enhance the accuracy of long-term blood pressure estimation. Compared to traditional manual calibration, the proposed auto-calibration method can perform frequent calibration of the model without requiring the true BP values. Furthermore, under the condition of daily auto-calibration, the system attains an optimal Mean Absolute Error (MAE) of 3.77 mmHg and 2.62 mmHg for systolic BP (SBP) and diastolic BP (DBP) respectively, significantly outperforming the performance achieved through traditional calibration methods. This work provides a novel conceptual framework to guide the calibration of cuffless wearable devices for BP monitoring.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 30 (1) , 303-314
Open AccessMulti-Wavelength Photoplethysmographic Assessment of Fingertip Vasculature for Auto-Calibrated Cuffless Blood Pressure Monitoring
Long-term cuffless monitoring of blood pressure (BP) is of immense value in the diagnosis and prevention of cardiovascular diseases (CVD). While there are critical needs for wearable cuffless BP monitoring devices in personalized CVD care and hypertension management, current technologies face challenges in long-term accuracy which limits significantly its clinical applicability. To maintain the accuracy of cuffless blood pressure forecasting, frequent calibration is a vital necessity. However, conventional BP calibration approaches are inherently inconvenient and time-consuming. In this work, we address the challenge by developing a novel auto-calibration system enabling long-term BP estimation. The innovation of this approach combines depth-resolved vascular characteristics extracted from multi-wavelength photoplethysmographic (MWPPG) measurements at fingertip, with an adaptive cross-modal knowledge distillation algorithm for continuous refinement of blood pressure estimation. We have evaluated the system on the CAS-BP database of over a thousand subjects using various calibration strategies. The results have shown that frequent calibration can effectively enhance the accuracy of long-term blood pressure estimation. Compared to traditional manual calibration, the proposed auto-calibration method can perform frequent calibration of the model without requiring the true BP values. Furthermore, under the condition of daily auto-calibration, the system attains an optimal Mean Absolute Error (MAE) of 3.77 mmHg and 2.62 mmHg for systolic BP (SBP) and diastolic BP (DBP) respectively, significantly outperforming the performance achieved through traditional calibration methods. This work provides a novel conceptual framework to guide the calibration of cuffless wearable devices for BP monitoring.
- 6 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (8) , 5438-5451
Dynamic Beat-to-Beat Measurements of Blood Pressure Using Multimodal Physiological Signals and a Hybrid CNN-LSTM Model
Wearable cuffless blood pressure (BP) technology is emerging as a critical tool for monitoring hypertension, the leading risk factor of most cardiovascular diseases. However, current cuffless BP methods are not accurate enough for clinical use, because they mainly use single or dual modalities/features as inputs for estimation. To address this challenge, we propose multimodal McBP-Net, built with hybrid CNN-LSTM architecture combing two-layer convolution operations with four-layer LSTMs to capture both local signal features and temporal dependencies for continuous dynamic beat-to-beat BP estimation. The McBP-Net includes photoplethysmographic, electrocardiographic, impedanceplethysmographic (IPG), and skin temperature (ST) signals as inputs. Validated on 23 subjects undergoing cold pressor test to induce large BP variability, the McBP-Net achieves the mean absolute errors of 4.19 and 2.98 mmHg for systolic BP (SBP) and diastolic BP (DBP), respectively, which fall within the accuracy range required by the Grade A of IEEE standard. The integration of four multimodal signals improves performance by 16.20%, 37.37%, and 49.52% over three-, dual-, and single-modality approaches, respectively, with significant contributions from IPG and ST signals. Notably, ST shows a strong nonlinear relationship with BP with high mutual information of 0.9056 for SBP. Furthermore, McBP-Net achieves a reasonable balance between accuracy and computational efficiency, offering inference speed of 36.7% faster and reducing computational demands by 78% compared to transformer-based models tested. Importantly, it maintains robust performance, with only a 0.21 mmHg degradation in dynamic SBP estimation when trained on rest-stage data. McBP-Net demonstrates promising potential in medical-grade wearable cuffless dynamic BP measurements.
- 6 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (8) , 5438-5451
Dynamic Beat-to-Beat Measurements of Blood Pressure Using Multimodal Physiological Signals and a Hybrid CNN-LSTM Model
Wearable cuffless blood pressure (BP) technology is emerging as a critical tool for monitoring hypertension, the leading risk factor of most cardiovascular diseases. However, current cuffless BP methods are not accurate enough for clinical use, because they mainly use single or dual modalities/features as inputs for estimation. To address this challenge, we propose multimodal McBP-Net, built with hybrid CNN-LSTM architecture combing two-layer convolution operations with four-layer LSTMs to capture both local signal features and temporal dependencies for continuous dynamic beat-to-beat BP estimation. The McBP-Net includes photoplethysmographic, electrocardiographic, impedanceplethysmographic (IPG), and skin temperature (ST) signals as inputs. Validated on 23 subjects undergoing cold pressor test to induce large BP variability, the McBP-Net achieves the mean absolute errors of 4.19 and 2.98 mmHg for systolic BP (SBP) and diastolic BP (DBP), respectively, which fall within the accuracy range required by the Grade A of IEEE standard. The integration of four multimodal signals improves performance by 16.20%, 37.37%, and 49.52% over three-, dual-, and single-modality approaches, respectively, with significant contributions from IPG and ST signals. Notably, ST shows a strong nonlinear relationship with BP with high mutual information of 0.9056 for SBP. Furthermore, McBP-Net achieves a reasonable balance between accuracy and computational efficiency, offering inference speed of 36.7% faster and reducing computational demands by 78% compared to transformer-based models tested. Importantly, it maintains robust performance, with only a 0.21 mmHg degradation in dynamic SBP estimation when trained on rest-stage data. McBP-Net demonstrates promising potential in medical-grade wearable cuffless dynamic BP measurements.
- 28 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (6) , 4109-4120
Personalized Continuous Blood Pressure Tracking Through Single Channel PPG in Wearable Scenarios
The real-time tracking of human physiopathology states can significantly enhance the quality of personalized healthcare services. Photoplethysmography (PPG) detection is a rapid, portable and non-invasive method for measuring blood flow volume, widely used for monitoring blood pressure (BP) and cardiovascular status. However, continuous BP monitoring technologies based on PPG face numerous challenges in real-world wearable scenarios, such as poor signal quality, complex model computation, and the need for frequent calibration. This work proposed a personalized continuous BP tracking pipeline that performed automatic PPG signal quality grading to reduce the difficulty of model fitting, introduced a lightweight BP model (SCI-GTCN) to alleviate computational complexity, and employed an adaptive calibration strategy to achieve long-term BP monitoring performance under different scenarios. The proposed pipeline was validated using data from 134 subjects in various monitoring scenarios (daytime, nighttime, and abnormal states), assessing the model's performance during rapid BP changes, circadian rhythm fluctuations, and long-term monitoring. The ME±SD was 0.99±7.91/0.36±5.43 mmHg. Overall, the results of our method are within the accuracy requirements of the Association for the Advancement of Medical Instrumentation (AAMI) standards, though the subject distribution differs. The method demonstrated good robustness and applicability, making it convenient for deployment on wearable devices and promising in the healthcare field.
- 28 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (6) , 4109-4120
Personalized Continuous Blood Pressure Tracking Through Single Channel PPG in Wearable Scenarios
The real-time tracking of human physiopathology states can significantly enhance the quality of personalized healthcare services. Photoplethysmography (PPG) detection is a rapid, portable and non-invasive method for measuring blood flow volume, widely used for monitoring blood pressure (BP) and cardiovascular status. However, continuous BP monitoring technologies based on PPG face numerous challenges in real-world wearable scenarios, such as poor signal quality, complex model computation, and the need for frequent calibration. This work proposed a personalized continuous BP tracking pipeline that performed automatic PPG signal quality grading to reduce the difficulty of model fitting, introduced a lightweight BP model (SCI-GTCN) to alleviate computational complexity, and employed an adaptive calibration strategy to achieve long-term BP monitoring performance under different scenarios. The proposed pipeline was validated using data from 134 subjects in various monitoring scenarios (daytime, nighttime, and abnormal states), assessing the model's performance during rapid BP changes, circadian rhythm fluctuations, and long-term monitoring. The ME±SD was 0.99±7.91/0.36±5.43 mmHg. Overall, the results of our method are within the accuracy requirements of the Association for the Advancement of Medical Instrumentation (AAMI) standards, though the subject distribution differs. The method demonstrated good robustness and applicability, making it convenient for deployment on wearable devices and promising in the healthcare field.
- 13 December 2023
- Published by Elsevier in Pattern Recognition
- Vol. 149
DSText V2: A comprehensive video text spotting dataset for dense and small text
- 13 December 2023
- Published by Elsevier in Pattern Recognition
- Vol. 149
DSText V2: A comprehensive video text spotting dataset for dense and small text
- 14 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 26 (12) , 5907-5917
A Refined Blood Pressure Estimation Model Based on Single Channel Photoplethysmography
This study proposed a refined BP prediction strategy that using single-channel photoplethysmography (PPG) signals to stratify populations by cardiovascular status before BP estimation. Combining demographic characteristics (age, gender) and pulse wave morphological features, the random forest was applied to screen two kinds of typical cardiovascular diseases (CVDs), with an accuracy of 92.2%. A deep learning model (BiLSTM-At) was proposed to estimate the long-term BP trend for different CVD groups. Transfer learning technique was used for personalized modeling to reduce computational complexity while improving performance. The method was validated on 255 patients with different CVDs. The mean absolute errors (MAEs) of systolic blood pressure (SBP) and diastolic blood pressure (DBP) estimation were 2.815 mmHg and 1.876 mmHg for normal subjects, 3.024 mmHg and 1.334 mmHg for AF subjects, and 4.444 mmHg and 2.549 mmHg for CA subjects. The results met the American Association for the Advancement of Medical Instrumentations (AAMI) and British Hypertension Society (BHS) Class A criteria. This indicated that our strategy has good performance and can realize long-term monitoring of BP through a small batch samples, with the potential to implement real-time monitoring in healthy devices.
- 14 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 26 (12) , 5907-5917
A Refined Blood Pressure Estimation Model Based on Single Channel Photoplethysmography
This study proposed a refined BP prediction strategy that using single-channel photoplethysmography (PPG) signals to stratify populations by cardiovascular status before BP estimation. Combining demographic characteristics (age, gender) and pulse wave morphological features, the random forest was applied to screen two kinds of typical cardiovascular diseases (CVDs), with an accuracy of 92.2%. A deep learning model (BiLSTM-At) was proposed to estimate the long-term BP trend for different CVD groups. Transfer learning technique was used for personalized modeling to reduce computational complexity while improving performance. The method was validated on 255 patients with different CVDs. The mean absolute errors (MAEs) of systolic blood pressure (SBP) and diastolic blood pressure (DBP) estimation were 2.815 mmHg and 1.876 mmHg for normal subjects, 3.024 mmHg and 1.334 mmHg for AF subjects, and 4.444 mmHg and 2.549 mmHg for CA subjects. The results met the American Association for the Advancement of Medical Instrumentations (AAMI) and British Hypertension Society (BHS) Class A criteria. This indicated that our strategy has good performance and can realize long-term monitoring of BP through a small batch samples, with the potential to implement real-time monitoring in healthy devices.
- 27 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (13) , 14360-14368
Study of a Ring-Type Surgical Pleth Index Monitoring System Based on Flexible PPG Sensor
Rings have attracted more and more attention in the study of wearable health monitoring. This study focused on a ring type Surgical Pleth Index (SPI) monitoring system based on photoplethysmography (PPG) signal acquired from finger root, where the unique sensor array structure was simulated and verified by Monte Carlo approach. The circuit board was fabricated in the form of rigid flexible PCB that can be bended according to different curve surface. The PPG signal acquired from the proposed system and SPI (GE Carestation 620 A2) data ware monitored from 24 patients simultaneously during surgical procedures. Subsequently, 55,547 heart beats with complete photoelectric tracing pulse waves from finger root were employed to extract different dynamic PPG features, where the index of analgesic depth or pain intensity is quantified. We utilized a machine learning strategy based on regularized linear regression to construct a specialized SPI model. The arithmetic mean and standard deviation of SPI_FR was 38.19± 21.54, compared with 36.54± 24.87 accordingly. A total 94.75% of the SPI value from finger root (SPI_FR) fell within the 95% confidence interval, and it also showed that the ring-type SPI monitoring system had good consistency and accuracy in comparison with the SPI data from GE. Generally, this study provides a ring-type healthcare system and makes an extensive use of sensors to gain understandings on patients' status during surgical procedures, which has the potential application in future surgery.
- 27 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (13) , 14360-14368
Study of a Ring-Type Surgical Pleth Index Monitoring System Based on Flexible PPG Sensor
Rings have attracted more and more attention in the study of wearable health monitoring. This study focused on a ring type Surgical Pleth Index (SPI) monitoring system based on photoplethysmography (PPG) signal acquired from finger root, where the unique sensor array structure was simulated and verified by Monte Carlo approach. The circuit board was fabricated in the form of rigid flexible PCB that can be bended according to different curve surface. The PPG signal acquired from the proposed system and SPI (GE Carestation 620 A2) data ware monitored from 24 patients simultaneously during surgical procedures. Subsequently, 55,547 heart beats with complete photoelectric tracing pulse waves from finger root were employed to extract different dynamic PPG features, where the index of analgesic depth or pain intensity is quantified. We utilized a machine learning strategy based on regularized linear regression to construct a specialized SPI model. The arithmetic mean and standard deviation of SPI_FR was 38.19± 21.54, compared with 36.54± 24.87 accordingly. A total 94.75% of the SPI value from finger root (SPI_FR) fell within the 95% confidence interval, and it also showed that the ring-type SPI monitoring system had good consistency and accuracy in comparison with the SPI data from GE. Generally, this study provides a ring-type healthcare system and makes an extensive use of sensors to gain understandings on patients' status during surgical procedures, which has the potential application in future surgery.
- Open Access
- 15 December 2016
- Published by Springer Nature in BMC Oral Health
- Vol. 16 (1) , 1-7
Salivary and serum inflammatory mediators among pre-conception women with periodontal disease
There have been inconsistent conclusions regarding the levels of inflammatory mediators in saliva and serum among people with or without periodontal disease. Although pre-conception has been put forward as the optimal time for the periodontal treatment in order to improving pregnancy outcomes, few studies have been conducted to examine inflammatory mediators in saliva and serum among pre-conception women. Pre-conception women were recruited between January 2012 and December 2014. Women were provided with an oral health examination to detect periodontal disease. Salivary and serum samples were collected at the same of examination. Inflammatory mediators includinginterleukin-1 beta (IL-1β), IL-6, tumor necrosis factor alpha (TNF-α) and beta-glucuronidase (β–glucuronidase) were tested and analyzed among women with overall periodontal disease (n = 442) or moderate/severe periodontal disease (n = 247). Results were compared to that in women with a healthy periodontium (n = 91). Significantly increased concentrations of inflammatory mediators of IL-1β, IL-6, TNF-α and β-glucuronidase in saliva and IL-1β, β-glucuronidase and TNF-α in serum were found among pre-conception women with moderate/severe periodontal disease, compared with women without periodontal disease. Significantly increased levels were also found in all the above saliva inflammatory mediators and in serum IL-1β and TNF-α among women with overall periodontal disease. The levels of all inflammatory mediators in saliva and almost all inflammatory mediators except IL-6 in serum significantly increased with severity of periodontal disease. Periodontal disease is highly associated with the elevated levels of inflammatory mediators in saliva and some mediators in serum among pre-conception women.
- 15 December 2016
- Published by Springer Nature in BMC Oral Health
- Vol. 16 (1) , 1-7
Open AccessSalivary and serum inflammatory mediators among pre-conception women with periodontal disease
There have been inconsistent conclusions regarding the levels of inflammatory mediators in saliva and serum among people with or without periodontal disease. Although pre-conception has been put forward as the optimal time for the periodontal treatment in order to improving pregnancy outcomes, few studies have been conducted to examine inflammatory mediators in saliva and serum among pre-conception women. Pre-conception women were recruited between January 2012 and December 2014. Women were provided with an oral health examination to detect periodontal disease. Salivary and serum samples were collected at the same of examination. Inflammatory mediators includinginterleukin-1 beta (IL-1β), IL-6, tumor necrosis factor alpha (TNF-α) and beta-glucuronidase (β–glucuronidase) were tested and analyzed among women with overall periodontal disease (n = 442) or moderate/severe periodontal disease (n = 247). Results were compared to that in women with a healthy periodontium (n = 91). Significantly increased concentrations of inflammatory mediators of IL-1β, IL-6, TNF-α and β-glucuronidase in saliva and IL-1β, β-glucuronidase and TNF-α in serum were found among pre-conception women with moderate/severe periodontal disease, compared with women without periodontal disease. Significantly increased levels were also found in all the above saliva inflammatory mediators and in serum IL-1β and TNF-α among women with overall periodontal disease. The levels of all inflammatory mediators in saliva and almost all inflammatory mediators except IL-6 in serum significantly increased with severity of periodontal disease. Periodontal disease is highly associated with the elevated levels of inflammatory mediators in saliva and some mediators in serum among pre-conception women.
- Open Access
- 9 December 2013
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 13 (1) , 228
A randomized controlled trial of pre-conception treatment for periodontal disease to improve periodontal status during pregnancy and birth outcomes
Evidence has suggested that periodontal disease is associated with an increased risk of various adverse pregnancy and birth outcomes. However, several large clinical randomized controlled trials failed to demonstrate periodontal therapy during pregnancy reduced the incidence of adverse pregnancy and birth outcomes. It has been suggested that the pre-conception period may be an optimal period for periodontal disease treatment rather than during pregnancy. To date, no randomized controlled trial (RCT) has examined if treating periodontal disease before pregnancy reduces adverse birth outcomes. This study aims to examine if the pre-conception treatment of periodontal disease will lead to improved periodontal status during late pregnancy and subsequent birth outcomes. A sample of 470 (235 in each arm of the study) pre-conception women who plan to conceive within one year and with periodontal disease will be recruited for the study. All participants will be randomly allocated to the intervention or control group. The intervention group will receive free therapy including dental scaling and root planning (the standard therapy), supragingival prophylaxis, and oral hygiene education. The control group will only receive supragingival prophylaxis and oral hygiene education. Women will be followed throughout their pregnancy and then to childbirth. The main outcomes include periodontal disease status in late pregnancy and birth outcomes measured such as mean birth weight (grams), and mean gestational age (weeks). Periodontal disease will be diagnosed through a dental examination by measuring probing depth, clinical attachment loss and percentage of bleeding on probing (BOP) between gestational age of 32 and 36 weeks. Local and systemic inflammatory mediators are also included as main outcomes. This will be the first RCT to test whether treating periodontal disease among pre-conception women reduces periodontal disease during pregnancy and prevents adverse birth outcomes. If the effect of pre-pregnancy periodontal treatment is confirmed, this intervention could be recommended for application in low- or middle-income countries to improve both oral health and maternal and child health. This trial is registered with Chinese Clinical Trial Registry (ChiCTR): ChiCTR-TRC-12001913 .
- 9 December 2013
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 13 (1) , 228
Open AccessA randomized controlled trial of pre-conception treatment for periodontal disease to improve periodontal status during pregnancy and birth outcomes
Evidence has suggested that periodontal disease is associated with an increased risk of various adverse pregnancy and birth outcomes. However, several large clinical randomized controlled trials failed to demonstrate periodontal therapy during pregnancy reduced the incidence of adverse pregnancy and birth outcomes. It has been suggested that the pre-conception period may be an optimal period for periodontal disease treatment rather than during pregnancy. To date, no randomized controlled trial (RCT) has examined if treating periodontal disease before pregnancy reduces adverse birth outcomes. This study aims to examine if the pre-conception treatment of periodontal disease will lead to improved periodontal status during late pregnancy and subsequent birth outcomes. A sample of 470 (235 in each arm of the study) pre-conception women who plan to conceive within one year and with periodontal disease will be recruited for the study. All participants will be randomly allocated to the intervention or control group. The intervention group will receive free therapy including dental scaling and root planning (the standard therapy), supragingival prophylaxis, and oral hygiene education. The control group will only receive supragingival prophylaxis and oral hygiene education. Women will be followed throughout their pregnancy and then to childbirth. The main outcomes include periodontal disease status in late pregnancy and birth outcomes measured such as mean birth weight (grams), and mean gestational age (weeks). Periodontal disease will be diagnosed through a dental examination by measuring probing depth, clinical attachment loss and percentage of bleeding on probing (BOP) between gestational age of 32 and 36 weeks. Local and systemic inflammatory mediators are also included as main outcomes. This will be the first RCT to test whether treating periodontal disease among pre-conception women reduces periodontal disease during pregnancy and prevents adverse birth outcomes. If the effect of pre-pregnancy periodontal treatment is confirmed, this intervention could be recommended for application in low- or middle-income countries to improve both oral health and maternal and child health. This trial is registered with Chinese Clinical Trial Registry (ChiCTR): ChiCTR-TRC-12001913 .