Zhen Mao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhen Mao has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
Florian Beuer
5 shared publications- Franziska Schmidt
Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Aßmannshauser Str. 4-6, 14197 Berlin, Germany
4 shared publications - Elisabeth Prause
Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität Zu Berlin, Berlin, Germany
3 shared publications - Florian Beuer
Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Aßmannshauser Str. 4-6, 14197 Berlin, Germany
3 shared publications Jamila Yassine
Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt, Universität zu Berlin, Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Aßmannshauser Str. 4-6, Berlin 14197, Germany
3 shared publications- Andreas Dominik Schwitalla
Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Dental Materials and Biomaterial Research, Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Aßmannshauser Str. 4-6, 14197, Berlin, Germany; Einstein Center Digital Future (ECDF), Robert-Koch-Forum, Wilhelmstr. 67, 10117 Berlin, Germany
2 shared publications
Latest Publications
- Open Access
- 6 November 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 177
Accuracy of robotic computer-assisted implant surgery in fully edentulous patients: a systematic review and meta-analysis
- 6 November 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 177
Open AccessAccuracy of robotic computer-assisted implant surgery in fully edentulous patients: a systematic review and meta-analysis
- Open Access
- 12 October 2026
- Published by Elsevier in The Journal of Prosthetic Dentistry
Enhancing color and comfort: A preliminary clinical study on the Dahl approach using 3D printed noninvasive restorations
- 12 October 2026
- Published by Elsevier in The Journal of Prosthetic Dentistry
Open AccessEnhancing color and comfort: A preliminary clinical study on the Dahl approach using 3D printed noninvasive restorations
- 8 September 2026
- Published by Wiley in Clinical Oral Implants Research
- Vol. 37 (11) , 1301-1312
Accuracy of Pterygoid Implant Placement With Augmented and Mixed Reality Navigation: An In Vitro Study
Objectives: To evaluate the accuracy of augmented reality (AR) and mixed reality (MR)‐assisted technologies for pterygoid implant trajectory guidance under anatomically challenging posterior maxillary conditions in the in vitro experimental model. Materials and Methods: Cone beam computed tomography datasets from eight patients were used to reconstruct three‐dimensional ( 3D ) models of the pterygoid‐maxillary complex. Virtual implant placement was performed in planning software, and the corresponding standard tessellation language ( STL ) files were exported as the preoperative reference. For each patient, four resin models were fabricated and randomly assigned within the patient to the four implant placement techniques (free hand [ FH ]; static guide [ SG ]; AR ; MR ), resulting in 32 models in total. A surgeon placed 36 implants in all models according to group designs. Following implant placement, each model was digitized, and STL datasets were generated. These were superimposed with the preoperative reference STL in 3D analysis software, allowing calculation of angular and linear deviation. One‐way repeated measures ANOVA was applied to compare deviations among groups, with significance set at p < 0.05. Results: The SG group demonstrated the highest accuracy (coronal deviation 0.86 ± 0.73 mm; apical deviation 1.26 ± 0.60 mm; angular deviation 3.77° ± 1.84°). In contrast, the FH, AR, and MR groups exhibited greater deviations in all parameters, with the MR group showing the largest errors—particularly in apical deviation (3.81 ± 1.47 mm) and angular deviation (12.37 ± 5.05). Conclusions: Within the limitations of the in vitro model, the AR and MR‐assisted technologies tested in this study demonstrated limited accuracy for pterygoid implant placement.
- 8 September 2026
- Published by Wiley in Clinical Oral Implants Research
- Vol. 37 (11) , 1301-1312
Accuracy of Pterygoid Implant Placement With Augmented and Mixed Reality Navigation: An In Vitro Study
Objectives: To evaluate the accuracy of augmented reality (AR) and mixed reality (MR)‐assisted technologies for pterygoid implant trajectory guidance under anatomically challenging posterior maxillary conditions in the in vitro experimental model. Materials and Methods: Cone beam computed tomography datasets from eight patients were used to reconstruct three‐dimensional ( 3D ) models of the pterygoid‐maxillary complex. Virtual implant placement was performed in planning software, and the corresponding standard tessellation language ( STL ) files were exported as the preoperative reference. For each patient, four resin models were fabricated and randomly assigned within the patient to the four implant placement techniques (free hand [ FH ]; static guide [ SG ]; AR ; MR ), resulting in 32 models in total. A surgeon placed 36 implants in all models according to group designs. Following implant placement, each model was digitized, and STL datasets were generated. These were superimposed with the preoperative reference STL in 3D analysis software, allowing calculation of angular and linear deviation. One‐way repeated measures ANOVA was applied to compare deviations among groups, with significance set at p < 0.05. Results: The SG group demonstrated the highest accuracy (coronal deviation 0.86 ± 0.73 mm; apical deviation 1.26 ± 0.60 mm; angular deviation 3.77° ± 1.84°). In contrast, the FH, AR, and MR groups exhibited greater deviations in all parameters, with the MR group showing the largest errors—particularly in apical deviation (3.81 ± 1.47 mm) and angular deviation (12.37 ± 5.05). Conclusions: Within the limitations of the in vitro model, the AR and MR‐assisted technologies tested in this study demonstrated limited accuracy for pterygoid implant placement.
- Open Access
- 19 August 2026
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 12 (1) , 40
Prospective clinical study to evaluate the survival of two-piece zirconia implants: a single-center study. 36-month results
Purpose: To evaluate the 36-month survival and clinical outcomes of two-piece zirconia implants restored with screw-retained glass-ceramic crowns on PEKK abutments. Methods: This prospective single-center clinical study evaluated implant survival as the primary outcome, with secondary outcomes including peri-implant soft tissue parameters, marginal bone level changes, and patient-reported outcome measures. Twenty-four patients received single CERALOG Hexalobe two-piece zirconia implants manufactured by ceramic injection molding (CIM) in healed sites. After 6-month submerged healing, implants were restored with provisional screw-retained crowns on PEKK abutments, followed by definitive lithium disilicate crowns (IPS e.max Press) on PEKK abutments secured with titanium abutment screws (25 Ncm). Clinical and radiographic examinations were performed at implant placement, re-entry, definitive loading, and at 12-, 24-, and 36-month follow-ups. Implant survival was analyzed using Kaplan–Meier estimates. Results: Of 23 evaluable implants, nine failed within the first 12 months: six due to failed osseointegration (two at re-entry, three during provisional restoration, one after definitive loading) and three due to implant fracture (one during provisional restoration, two after definitive loading). Kaplan-Meier survival rate was 60.9% (95% CI; 41–81%) at 12 months. No additional failures occurred between 12 and 36 months. Peri-implant soft tissue parameters of surviving implants showed favorable trends (PPD: 2.7 ± 0.7 mm at 12 months, 2.0 ± 0.5 mm at 24 months, 1.9 ± 0.8 mm at 36 months; BOP: 26%, 21%, and 18%, respectively; MGI: 0.38 ± 0.36 at 12 months, 0.40 ± 0.76 at 24 months, 0.21 ± 0.48 at 36 months). At the implant level, peri-implant mucositis was diagnosed in 7 of 13 implants (53.8%) at 36 months; no peri-implantitis was observed throughout the observation period. Mean DIB was 1.9 ± 0.6 mm at definitive loading, 1.6 ± 0.5 mm at 24 months, and 1.5 ± 0.9 mm at 36 months. One abutment screw loosening at 24 months was successfully managed. Patients with surviving implants reported high satisfaction scores (overall satisfaction: 5.0 ± 0.0 at 36 months). Conclusions: The 39.1% early failure rate within the first 12 months was followed by stable marginal bone levels through 36 months in implants that achieved successful osseointegration. However, peri-implant mucositis remained prevalent at 36 months, underlining the need for peri-implant maintenance. The early post-loading period represents the critical determinant of long-term implant survival in this system. Extended follow-up through 60 months is ongoing.
- 19 August 2026
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 12 (1) , 40
Open AccessProspective clinical study to evaluate the survival of two-piece zirconia implants: a single-center study. 36-month results
Purpose: To evaluate the 36-month survival and clinical outcomes of two-piece zirconia implants restored with screw-retained glass-ceramic crowns on PEKK abutments. Methods: This prospective single-center clinical study evaluated implant survival as the primary outcome, with secondary outcomes including peri-implant soft tissue parameters, marginal bone level changes, and patient-reported outcome measures. Twenty-four patients received single CERALOG Hexalobe two-piece zirconia implants manufactured by ceramic injection molding (CIM) in healed sites. After 6-month submerged healing, implants were restored with provisional screw-retained crowns on PEKK abutments, followed by definitive lithium disilicate crowns (IPS e.max Press) on PEKK abutments secured with titanium abutment screws (25 Ncm). Clinical and radiographic examinations were performed at implant placement, re-entry, definitive loading, and at 12-, 24-, and 36-month follow-ups. Implant survival was analyzed using Kaplan–Meier estimates. Results: Of 23 evaluable implants, nine failed within the first 12 months: six due to failed osseointegration (two at re-entry, three during provisional restoration, one after definitive loading) and three due to implant fracture (one during provisional restoration, two after definitive loading). Kaplan-Meier survival rate was 60.9% (95% CI; 41–81%) at 12 months. No additional failures occurred between 12 and 36 months. Peri-implant soft tissue parameters of surviving implants showed favorable trends (PPD: 2.7 ± 0.7 mm at 12 months, 2.0 ± 0.5 mm at 24 months, 1.9 ± 0.8 mm at 36 months; BOP: 26%, 21%, and 18%, respectively; MGI: 0.38 ± 0.36 at 12 months, 0.40 ± 0.76 at 24 months, 0.21 ± 0.48 at 36 months). At the implant level, peri-implant mucositis was diagnosed in 7 of 13 implants (53.8%) at 36 months; no peri-implantitis was observed throughout the observation period. Mean DIB was 1.9 ± 0.6 mm at definitive loading, 1.6 ± 0.5 mm at 24 months, and 1.5 ± 0.9 mm at 36 months. One abutment screw loosening at 24 months was successfully managed. Patients with surviving implants reported high satisfaction scores (overall satisfaction: 5.0 ± 0.0 at 36 months). Conclusions: The 39.1% early failure rate within the first 12 months was followed by stable marginal bone levels through 36 months in implants that achieved successful osseointegration. However, peri-implant mucositis remained prevalent at 36 months, underlining the need for peri-implant maintenance. The early post-loading period represents the critical determinant of long-term implant survival in this system. Extended follow-up through 60 months is ongoing.
- Open Access
- 2 August 2026
- Published by SAGE Publications in Journal of Dental Research
Printing Parameters and Surface Treatments on Color and Translucency Stability
Additive manufacturing (AM) has expanded in dentistry, yet the color and translucency stability of 3-dimensional-printed resin-based materials remain insufficiently understood. This study investigated the main and interaction effects of printing orientation, specimen thickness, and surface treatments on the color and translucency stability of a 3-dimensional printed resin–ceramic hybrid material. Ninety AM specimens were fabricated using a factorial design combining 3 printing orientations, 3 specimen thicknesses, and 2 surface treatments (3 × 3 × 2, n = 5 per condition) and compared with 30 subtractively manufactured control specimens (Vita Enamic). Aging was simulated by thermocycling (5000 cycles, 5–55 °C). Color coordinates were measured via the Commission Internationale de l’Éclairage L*a*b* color system, and color change and translucency change were calculated. Degree of conversion, water sorption, and surface roughness were also evaluated. Printing orientation and specimen thickness significantly affected color change and translucency change ( P < 0.05), with the 90° orientation showing lower changes than 0° and 45°. Surface treatment had a limited influence on color and translucency stability, although glazing resulted in higher water sorption as compared with polishing ( P < 0.05). No significant effects of printing orientation were observed for degree of conversion or surface roughness, whereas surface treatment significantly influenced surface roughness ( P < 0.05). Despite these variations, all groups remained within clinically acceptable thresholds for color and translucency changes. Overall, the findings suggest that AM resin–ceramic restorations have potential for use in definitive restorations. Optimizing printing orientation and material thickness may enhance the color and translucency stability of AM resin–ceramic restorations, supporting their clinical applicability.
- 2 August 2026
- Published by SAGE Publications in Journal of Dental Research
Open AccessPrinting Parameters and Surface Treatments on Color and Translucency Stability
Additive manufacturing (AM) has expanded in dentistry, yet the color and translucency stability of 3-dimensional-printed resin-based materials remain insufficiently understood. This study investigated the main and interaction effects of printing orientation, specimen thickness, and surface treatments on the color and translucency stability of a 3-dimensional printed resin–ceramic hybrid material. Ninety AM specimens were fabricated using a factorial design combining 3 printing orientations, 3 specimen thicknesses, and 2 surface treatments (3 × 3 × 2, n = 5 per condition) and compared with 30 subtractively manufactured control specimens (Vita Enamic). Aging was simulated by thermocycling (5000 cycles, 5–55 °C). Color coordinates were measured via the Commission Internationale de l’Éclairage L*a*b* color system, and color change and translucency change were calculated. Degree of conversion, water sorption, and surface roughness were also evaluated. Printing orientation and specimen thickness significantly affected color change and translucency change ( P < 0.05), with the 90° orientation showing lower changes than 0° and 45°. Surface treatment had a limited influence on color and translucency stability, although glazing resulted in higher water sorption as compared with polishing ( P < 0.05). No significant effects of printing orientation were observed for degree of conversion or surface roughness, whereas surface treatment significantly influenced surface roughness ( P < 0.05). Despite these variations, all groups remained within clinically acceptable thresholds for color and translucency changes. Overall, the findings suggest that AM resin–ceramic restorations have potential for use in definitive restorations. Optimizing printing orientation and material thickness may enhance the color and translucency stability of AM resin–ceramic restorations, supporting their clinical applicability.
- Open Access
- 16 April 2026
- Published by Elsevier in Dental Materials
- Vol. 42 (9) , 1560-1568
Mechanical and biological properties of two new commercial PEEK framework materials for fixed and removable dental prostheses compared to unfilled PEEK: An in vitro study
- 16 April 2026
- Published by Elsevier in Dental Materials
- Vol. 42 (9) , 1560-1568
Open AccessMechanical and biological properties of two new commercial PEEK framework materials for fixed and removable dental prostheses compared to unfilled PEEK: An in vitro study
- Open Access
- 16 September 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 163, 106111
Effect of post-processing procedures on the dimensional accuracy and internal gap of additively manufactured definitive implant-supported single crowns: An in vitro study
- 16 September 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 163, 106111
Open AccessEffect of post-processing procedures on the dimensional accuracy and internal gap of additively manufactured definitive implant-supported single crowns: An in vitro study
- Open Access
- 13 June 2024
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 28 (7) , 1-12
Effect of surface treatment strategies on bond strength of additively and subtractively manufactured hybrid materials for permanent crowns
Objectives: The purpose of this study is to evaluate the bond strength of different computer-aided design / computer-aided manufacturing (CAD/CAM) hybrid ceramic materials following different pretreatments. Methods: A total of 306 CAD/CAM hybrid material specimens were manufactured, n = 102 for each material (VarseoSmile Crownplus [VSCP] by 3D-printing; Vita Enamic [VE] and Grandio Blocs [GB] by milling). Each material was randomly divided into six groups regarding different pretreatment strategies: control, silane, sandblasting (50 μm aluminum oxide particles), sandblasting + silane, etching (9% hydrofluorics acid), etching + silane. Subsequently, surface roughness (Ra) values, surface free energy (SFE) were measured. Each specimen was bonded with a dual-cured adhesive composite. Half of the specimens were subjected to thermocycling (5000 cycles, 5–55 °C). The shear bond strength (SBS) test was performed. Data were analyzed by using a two-way analysis of variance, independent t-test, and Mann-Whitney-U-test (α = 0.05). Results: Material type (p = 0.001), pretreatment strategy (p < 0.001), and the interaction (p < 0.001) all had significant effects on Ra value. However, only etching on VSCP and VE surface increased SFE value significantly. Regarding SBS value, no significant difference was found among the three materials (p = 0.937), while the pretreatment strategy significantly influenced SBS (p < 0.05). Etching on VSCP specimens showed the lowest mean value among all groups, while sandblasting and silane result in higher SBS for all test materials. Conclusions: The bond strength of CAD/CAM hybrid ceramic materials for milling and 3D-printing was comparable. Sandblasting and silane coupling were suitable for both millable and printable materials, while hydrofluoric etching should not be recommended for CAD/CAM hybrid ceramic materials. Clinical relevance: Since comparable evidence between 3D-printable and millable CAD/CAM dental hybrid materials is scarce, the present study gives clear guidance for pretreatment planning on different materials.
- 13 June 2024
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 28 (7) , 1-12
Open AccessEffect of surface treatment strategies on bond strength of additively and subtractively manufactured hybrid materials for permanent crowns
Objectives: The purpose of this study is to evaluate the bond strength of different computer-aided design / computer-aided manufacturing (CAD/CAM) hybrid ceramic materials following different pretreatments. Methods: A total of 306 CAD/CAM hybrid material specimens were manufactured, n = 102 for each material (VarseoSmile Crownplus [VSCP] by 3D-printing; Vita Enamic [VE] and Grandio Blocs [GB] by milling). Each material was randomly divided into six groups regarding different pretreatment strategies: control, silane, sandblasting (50 μm aluminum oxide particles), sandblasting + silane, etching (9% hydrofluorics acid), etching + silane. Subsequently, surface roughness (Ra) values, surface free energy (SFE) were measured. Each specimen was bonded with a dual-cured adhesive composite. Half of the specimens were subjected to thermocycling (5000 cycles, 5–55 °C). The shear bond strength (SBS) test was performed. Data were analyzed by using a two-way analysis of variance, independent t-test, and Mann-Whitney-U-test (α = 0.05). Results: Material type (p = 0.001), pretreatment strategy (p < 0.001), and the interaction (p < 0.001) all had significant effects on Ra value. However, only etching on VSCP and VE surface increased SFE value significantly. Regarding SBS value, no significant difference was found among the three materials (p = 0.937), while the pretreatment strategy significantly influenced SBS (p < 0.05). Etching on VSCP specimens showed the lowest mean value among all groups, while sandblasting and silane result in higher SBS for all test materials. Conclusions: The bond strength of CAD/CAM hybrid ceramic materials for milling and 3D-printing was comparable. Sandblasting and silane coupling were suitable for both millable and printable materials, while hydrofluoric etching should not be recommended for CAD/CAM hybrid ceramic materials. Clinical relevance: Since comparable evidence between 3D-printable and millable CAD/CAM dental hybrid materials is scarce, the present study gives clear guidance for pretreatment planning on different materials.
- Open Access
- 31 May 2024
- Published by Elsevier in Dental Materials
- Vol. 40 (8) , 1123-1127
Influence of sandblasting and bonding on the shear bond strength between differently pigmented polyetheretherketone (PEEK) and veneering composite after artificial aging
- 31 May 2024
- Published by Elsevier in Dental Materials
- Vol. 40 (8) , 1123-1127
Open AccessInfluence of sandblasting and bonding on the shear bond strength between differently pigmented polyetheretherketone (PEEK) and veneering composite after artificial aging
- Open Access
- 10 May 2024
- Published by Elsevier in Journal of Dentistry
- Vol. 146, 105000
Occlusal changes on implant-supported single crowns with one year follow-up after loading: A systematic review and meta-analysis
- 10 May 2024
- Published by Elsevier in Journal of Dentistry
- Vol. 146, 105000
Open AccessOcclusal changes on implant-supported single crowns with one year follow-up after loading: A systematic review and meta-analysis