David Saez De Jauregui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
David Saez De Jauregui has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
A. Grau
Karlsruher Institut für Technologie
3 shared publications- Andreas Grau
Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
3 shared publications - Anke-Susanne Müller
Karlsruher Institut für Technologie
3 shared publications C. Garion
European Organization for Nuclear Research
3 shared publications- Roberto Kersevan
European Organization for Nuclear Research
3 shared publications - A. Abada
Institut National de Physique Nucléaire et de Physique des Particules
2 shared publications
Latest Publications
- Open Access
- 21 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7)
Erratum to: Future Circular Collider Feasibility Study Report
- 21 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7)
Open AccessErratum to: Future Circular Collider Feasibility Study Report
- Top Cited PapersOpen Access
- 24 December 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (12)
Future Circular Collider Feasibility Study Report
Volume 1 of the FCC Feasibility Report presents an overview of the physics case, experimental programme, and detector concepts for the Future Circular Collider (FCC). This volume outlines how FCC would address some of the most profound open questions in particle physics, from precision studies of the Higgs and EW bosons and of the top quark, to the exploration of physics beyond the Standard Model. The report reviews the experimental opportunities offered by the staged implementation of FCC, beginning with an electron-positron collider (FCC-ee), operating at several centre-of-mass energies, followed by a hadron collider (FCC-hh). Benchmark examples are given of the expected physics performance, in terms of precision and sensitivity to new phenomena, of each collider stage. Detector requirements and conceptual designs for FCC-ee experiments are discussed, as are the specific demands that the physics programme imposes on the accelerator in the domains of the calibration of the collision energy, and the interface region between the accelerator and the detector. The report also highlights advances in detector, software and computing technologies, as well as the theoretical tools/reconstruction techniques that will enable the precision measurements and discovery potential of the FCC experimental programme. The content and structure of this report are guided by the scope and priorities defined in the mandate of the FCC Feasibility Study. It is therefore not intended to serve as an exhaustive review of the full physics potential of FCC. Several topics, already covered in earlier reports such as the FCC CDR, are not reiterated here or are addressed only briefly, in alignment with the study’s focus. This volume reflects the outcome of a global collaborative effort involving hundreds of scientists and institutions, aided by a dedicated community-building coordination, and provides a targeted assessment of the scientific opportunities and experimental foundations of the FCC programme.
- 24 December 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (12)
Top Cited PapersOpen AccessFuture Circular Collider Feasibility Study Report
Volume 1 of the FCC Feasibility Report presents an overview of the physics case, experimental programme, and detector concepts for the Future Circular Collider (FCC). This volume outlines how FCC would address some of the most profound open questions in particle physics, from precision studies of the Higgs and EW bosons and of the top quark, to the exploration of physics beyond the Standard Model. The report reviews the experimental opportunities offered by the staged implementation of FCC, beginning with an electron-positron collider (FCC-ee), operating at several centre-of-mass energies, followed by a hadron collider (FCC-hh). Benchmark examples are given of the expected physics performance, in terms of precision and sensitivity to new phenomena, of each collider stage. Detector requirements and conceptual designs for FCC-ee experiments are discussed, as are the specific demands that the physics programme imposes on the accelerator in the domains of the calibration of the collision energy, and the interface region between the accelerator and the detector. The report also highlights advances in detector, software and computing technologies, as well as the theoretical tools/reconstruction techniques that will enable the precision measurements and discovery potential of the FCC experimental programme. The content and structure of this report are guided by the scope and priorities defined in the mandate of the FCC Feasibility Study. It is therefore not intended to serve as an exhaustive review of the full physics potential of FCC. Several topics, already covered in earlier reports such as the FCC CDR, are not reiterated here or are addressed only briefly, in alignment with the study’s focus. This volume reflects the outcome of a global collaborative effort involving hundreds of scientists and institutions, aided by a dedicated community-building coordination, and provides a targeted assessment of the scientific opportunities and experimental foundations of the FCC programme.
- 14 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-6
HTS Undulator Design Study and First Results: Two Promising Magnet Concepts
Undulators are X-ray sources that are widely utilised in advanced synchrotron radiation sources and free-electron laser facilities. Due to sustainability and energy efficiency, the development focuses on small-scale, high-field, and especially compact undulators with short period lengths ($\leq$ 10 mm) and narrow magnetic gaps ($\leq$ 4 mm). Therefore, high-temperature superconducting (HTS) tapes, which can provide a high critical current density and high critical magnetic fields at higher temperatures, are extensively used and investigated at the Karlsruhe Institute of Technology. A new concept of superconducting undulators (SCUs) was introduced and further developed by laser-scribing a meander pattern into the superconducting layer to achieve a quasi-sinusoidal current path through the HTS tape. Here we present the complete and final design of such a compact SCU, in particular our latest results regarding the design of the liner with its tapering in the warm region, as well as the cryogenic cooling concept.
- 14 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-6
HTS Undulator Design Study and First Results: Two Promising Magnet Concepts
Undulators are X-ray sources that are widely utilised in advanced synchrotron radiation sources and free-electron laser facilities. Due to sustainability and energy efficiency, the development focuses on small-scale, high-field, and especially compact undulators with short period lengths ($\leq$ 10 mm) and narrow magnetic gaps ($\leq$ 4 mm). Therefore, high-temperature superconducting (HTS) tapes, which can provide a high critical current density and high critical magnetic fields at higher temperatures, are extensively used and investigated at the Karlsruhe Institute of Technology. A new concept of superconducting undulators (SCUs) was introduced and further developed by laser-scribing a meander pattern into the superconducting layer to achieve a quasi-sinusoidal current path through the HTS tape. Here we present the complete and final design of such a compact SCU, in particular our latest results regarding the design of the liner with its tapering in the warm region, as well as the cryogenic cooling concept.
- 17 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-4
Measurement Setup and Magnetic Field Studies of a Compact Superconducting Undulator With Laser-Structured HTS Tapes
Undulators are X-ray sources which are widely used in synchrotron storage rings and free-electron laser (FEL) facilities. As the development of future light sources envisages smaller and more compact undulators, it is necessary to construct small-scale high-field undulators with short period lengths $\lambda \,< $ 10 mm and narrow magnetic gaps $d_\text{mag} < $ 4 mm. Therefore, high-temperature superconducting (HTS) tapes are a promising candidate, since they offer a high critical current density at higher temperatures. Instead of the commonly used wounded coils of low-temperature superconducting (LTS) wires, such as NbTi, to generate the alternating magnetic dipole field, a meandering pattern is structured on the surface of the HTS tape with ps laser pulses to provide a sinusoidal current path through the tape, see Fig. 1 . This technique leads to a precise structure and at the same time prevents damage to the superconducting layer due to overheating. A new concept has been developed and improved at KIT. The new concept involves two opposing stacks of 30 laser-structured HTS tapes. The ends of each tape are soldered and connected to the tape above, resulting in an accordion-like arrangement, see Figs. 2 and 3 . This paper presents the general design and the preparation of the stacks of the compact SCU, followed by the results of a Biot-Savart magnetic field simulation. The magnetic field measurement setup and a first current carrying test of the two coils are included.
- 17 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-4
Measurement Setup and Magnetic Field Studies of a Compact Superconducting Undulator With Laser-Structured HTS Tapes
Undulators are X-ray sources which are widely used in synchrotron storage rings and free-electron laser (FEL) facilities. As the development of future light sources envisages smaller and more compact undulators, it is necessary to construct small-scale high-field undulators with short period lengths $\lambda \,< $ 10 mm and narrow magnetic gaps $d_\text{mag} < $ 4 mm. Therefore, high-temperature superconducting (HTS) tapes are a promising candidate, since they offer a high critical current density at higher temperatures. Instead of the commonly used wounded coils of low-temperature superconducting (LTS) wires, such as NbTi, to generate the alternating magnetic dipole field, a meandering pattern is structured on the surface of the HTS tape with ps laser pulses to provide a sinusoidal current path through the tape, see Fig. 1 . This technique leads to a precise structure and at the same time prevents damage to the superconducting layer due to overheating. A new concept has been developed and improved at KIT. The new concept involves two opposing stacks of 30 laser-structured HTS tapes. The ends of each tape are soldered and connected to the tape above, resulting in an accordion-like arrangement, see Figs. 2 and 3 . This paper presents the general design and the preparation of the stacks of the compact SCU, followed by the results of a Biot-Savart magnetic field simulation. The magnetic field measurement setup and a first current carrying test of the two coils are included.
- Open Access
- 10 November 2021
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 24 (11) , 113201
Photostimulated desorption performance of the future circular hadron collider beam screen
Synchrotron radiation (SR) originated at superconducting bending magnets is known to be at the origin of several beam detrimental effects related to vacuum instabilities. One of the major challenges in the design of the vacuum beam pipes of high-energy hadron colliders is the SR coping strategy. In the case of the future circular hadron collider (FCC-hh), a Cu-coated beam screen (BS) operating in the range of 40–60 K has been designed with the aim of protecting the superconducting magnet cold bores from direct synchrotron irradiation. In order to experimentally study the FCC-hh BS vacuum and cryogenic performance, two sample prototypes were manufactured and installed in the beam screen test-bench experiment (BESTEX) at the Karlsruhe Research Accelerator (KARA) at the Karlsruhe Institute of Technology (KIT). The emitted SR has a critical energy of 6.2 keV, very similar to the 4.6 keV of FCC-hh. Irradiation at both room (RT) and cryogenic (77 K) temperatures showed a significant reduction of the molecular photostimulated desorption yields () of the FCC-hh beam screen compared to those of Cu samples. A first approximation of and its evolution with the photon dose accumulated on the FCC-hh BS prototype at 77 K allows to estimate that a machine conditioning period of months would be needed to reduce the photostimulated molecular density at the necessary levels to ensure a 100 h beam lifetime at nominal FCC-hh operation.- 10 November 2021
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 24 (11) , 113201
Open AccessPhotostimulated desorption performance of the future circular hadron collider beam screen
Synchrotron radiation (SR) originated at superconducting bending magnets is known to be at the origin of several beam detrimental effects related to vacuum instabilities. One of the major challenges in the design of the vacuum beam pipes of high-energy hadron colliders is the SR coping strategy. In the case of the future circular hadron collider (FCC-hh), a Cu-coated beam screen (BS) operating in the range of 40–60 K has been designed with the aim of protecting the superconducting magnet cold bores from direct synchrotron irradiation. In order to experimentally study the FCC-hh BS vacuum and cryogenic performance, two sample prototypes were manufactured and installed in the beam screen test-bench experiment (BESTEX) at the Karlsruhe Research Accelerator (KARA) at the Karlsruhe Institute of Technology (KIT). The emitted SR has a critical energy of 6.2 keV, very similar to the 4.6 keV of FCC-hh. Irradiation at both room (RT) and cryogenic (77 K) temperatures showed a significant reduction of the molecular photostimulated desorption yields () of the FCC-hh beam screen compared to those of Cu samples. A first approximation of and its evolution with the photon dose accumulated on the FCC-hh BS prototype at 77 K allows to estimate that a machine conditioning period of months would be needed to reduce the photostimulated molecular density at the necessary levels to ensure a 100 h beam lifetime at nominal FCC-hh operation. - Open Access
- p. 2933-2935
Progress of the Development of a Superconducting Undulator as a THz Source for FELs
- p. 2933-2935
Open AccessProgress of the Development of a Superconducting Undulator as a THz Source for FELs