Andrés Plaza-Espín
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andrés Plaza-Espín has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Antonio Fons-Font
Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain
1 shared publication - Carla Fons-Badal
Department of Oral Medicine, Faculty of Medicine and Dentistry, University of Valencia, C/Gascó Oliag, 1, 46010 Valencia, Spain
1 shared publication - Francisco Javier Puertas
Sleep Unit, La Ribera University Hospital - FISABIO, Valencia, Spain
1 shared publication - Marina García-Selva
Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain
1 shared publication - Rocío Marco-Pitarch
Sleep Unit, Department of Stomatology, Faculty of Medicine and Dentistry University of Valencia Valencia Spain
1 shared publication - Rubén Agustín-Panadero
Department of Stomatology, Faculty of Medicine and Dentistry, Universitat de València, 46010 Valencia, Spain
1 shared publication
Latest Publications
- Open Access
- 11 November 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (22) , 5255
Correlation between Polysomnographic Parameters and Tridimensional Changes in the Upper Airway of Obstructive Sleep Apnea Patients Treated with Mandibular Advancement Devices
Background. The effectiveness of mandibular advancement devices has been solidly demonstrated in the past. They are considered a valid alternative treatment to continuous positive airway pressure for patients with obstructive sleep apnea. Nevertheless, the relationship between polysomnographic parameters and the increase in the volume of the upper airway in patients with obstructive sleep apnea syndrome has not been clearly established so far. This study aimed to determine the impact of these oral appliances upon the volume of the airway after the device titration phase and correlate it with the degree of mandibular advancement and the improvement of polysomnographic parameters. Methods. All patients were diagnosed by polysomnography and were treated with a customized, titratable mandibular advancement device. Three-dimensional volumetric measurements were performed using cone beam computed tomography. Results. The present study included 45 patients diagnosed with obstructive sleep apnea hypopnea syndrome (mild in 23 patients, moderate in 11 and severe in 11). Forty-four percent of the patients presented with an apnea hypopnea index 3, this represents a percentage increase of 20.9%, which was significantly correlated with an apnea hypopnea index and a minimum oxygen saturation improvement. Conclusions. The mandibular advancement device used was found to be effective in improving polysomnographic parameters. Moreover, the oral appliance was able to significantly increase the tridimensional dimensions of the upper airway. Moreover, this finding was correlated with a reduction in the apnea hypopnea index (p = 0.007) and an increase on minimum oxygen saturation (p = 0.033).
- 11 November 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (22) , 5255
Open AccessCorrelation between Polysomnographic Parameters and Tridimensional Changes in the Upper Airway of Obstructive Sleep Apnea Patients Treated with Mandibular Advancement Devices
Background. The effectiveness of mandibular advancement devices has been solidly demonstrated in the past. They are considered a valid alternative treatment to continuous positive airway pressure for patients with obstructive sleep apnea. Nevertheless, the relationship between polysomnographic parameters and the increase in the volume of the upper airway in patients with obstructive sleep apnea syndrome has not been clearly established so far. This study aimed to determine the impact of these oral appliances upon the volume of the airway after the device titration phase and correlate it with the degree of mandibular advancement and the improvement of polysomnographic parameters. Methods. All patients were diagnosed by polysomnography and were treated with a customized, titratable mandibular advancement device. Three-dimensional volumetric measurements were performed using cone beam computed tomography. Results. The present study included 45 patients diagnosed with obstructive sleep apnea hypopnea syndrome (mild in 23 patients, moderate in 11 and severe in 11). Forty-four percent of the patients presented with an apnea hypopnea index 3, this represents a percentage increase of 20.9%, which was significantly correlated with an apnea hypopnea index and a minimum oxygen saturation improvement. Conclusions. The mandibular advancement device used was found to be effective in improving polysomnographic parameters. Moreover, the oral appliance was able to significantly increase the tridimensional dimensions of the upper airway. Moreover, this finding was correlated with a reduction in the apnea hypopnea index (p = 0.007) and an increase on minimum oxygen saturation (p = 0.033).